General Cable Unicon® XLPE 1000MCM XLPE Low-Voltage Power 600 V UL Type RHH/RHW-2/USE-2 Single Conductor Copper

General Cable Unicon® XLPE 1000MCM XLPE Low-Voltage Power 600 V UL Type RHH/RHW-2/USE-2 Single Conductor Copper

Select gauge from drop-down menu for prices:

General Cable Unicon® XLPE 1000MCM XLPE Low-Voltage Power 600 V UL Type RHH/RHW-2/USE-2 Single Conductor Copper
Unicon XLPE 1000MCM XLPE Low-Voltage Power 600 V UL Type RHH/RHW-2/USE-2 Single Conductor Copper

Conductor: 14 AWG thru 1000 kcmil stranded annealed bare copper compressed class B stranding per ASTM B8

Insulation: Flame-retardant Cross-linked Polyethylene (XLPE), black 

Options: 
• 2 kV version 
• Tinned copper conductor 
• Class C stranding 
• Various colors available 
• Unicon® FREP® — flame-retardant Ethylene Propylene Rubber (EPR) insulation 
• Other constructions available upon request

Applications: 
• Ideally suited for use in a broad range of commercial, industrial and utility applications where reliability is a major concern, where maximum performance will be demanded and where space is limited 
• In free air, raceways or direct burial in accordance with NEC 

Features: 
• Rated at 90?C wet or dry 
• Smaller cable O.D. 
• Excellent electrical, thermal and physical properties 
• Excellent resistance to moisture 
• Excellent resistance to crush, compression cuts and heat deformation 
• Excellent flame resistance 
• Excellent low temperture cold bend characteristics 
• Meets cold bend test at -25?C 

Compliances: 
Industry Compliances: 
• National Electrical Code (NEC) 
• ICEA S-95-658/NEMA WC70 
• “FOR CT USE” on 1/0 AWG and larger in accordance with NEC 
• UL 44 Type RHH/RHW-2, UL File # E90494 
• UL 854 Type USE-2, UL File # E90499 

Flame Test Compliances: 
• UL 1581 VW-1
• For 1/0 AWG and larger: IEEE 383, IEEE 1202/CSA FT4, ICEA T-29-520 

Other Compliances: 
• EPA 40 CFR, Part 261 for leachable lead content per TCLP 
• OSHA Acceptable 

Packaging: Material cut to length and shipped on non-returnable wood reels

technical specification:
cond.size(awg/kcmil) 1000
cond.strand 61/.1280
nominal cond.diameter(inches) 1.13
nominal cond.diameter(mm) 28.70
minimum avg.insulation thickness(inches) 0.110
minimum avg.insulationthickness(mm) 2.79
nominal cableo.d.(inches)
1.37
nominal cableo.d.(mm) 34.80
copper weight(lbs/1000 ft)
3086
copper weight(kg/km) 4593
net weight(lbs/1000 ft) 3405
net weight(kg/km) 5068
ampacity (1)(60°c) 445
ampacity (1)(75°c) 545
ampacity (1) (90°c) 615
catalog number 16602.217500*