Belden Cable 22 and 18 AWG Audio Control and Instrumentation Multi Conductor UnShielded Non Plenum Cable

Belden Cable 22 and 18 AWG Audio Control and Instrumentation Multi Conductor UnShielded Non Plenum Cable

Select gauge from drop-down menu for prices:

Belden Cable 22 and 18 AWG Audio Control and Instrumentation Multi Conductor UnShielded Non Plenum Cable

Regular price $4.22 $2.81 Sale /per Foot

Belden Cable 22 and 18 AWG Audio Control and Instrumentation Multi Conductor UnShielded Non Plenum Cable

Description:
• 22 and 18 AWG stranded (7x30 and 19x30) tinned copper conductorsm conductors cabled, PVC insulation, PVC jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride (22 and 18 AWG)
• Wall Thickness (mm): 0.2794 (22 AWG) and 0.4826 (18 AWG)

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.8128

Applications: Applications for multi-conductor cables include computers, communications, instrumentation, sound, control, audio, and data transmission. Each of these cables is designed to protect signal integrity under critical conditions by reducing hum, noise, and crosstalk.

Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2576)
• Bulk Cable Weight: 39 lbs/1000 ft.
• Max. Recommended Pulling Tension: 78 lbs.
• Min. Bend Radius/Minor Axis: 2.500 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2576 (150 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Capacitance Conductor to Conductor (pF/ft): 30
• Nom. Capacitance Cond. to Other Cond. & Ground (pF/ft): 54
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 15.5 (22 AWG)
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 6.8 (18 AWG)
• Max. Operating Voltage - UL: 150 V RMS (UL AWM Style 2576)
• Max. Operating Voltage - UL: 300 V RMS (CMG)
• Max. Recommended Current: 2.5 Amps/Conductor @ 25°C (22 AWG)
• Max. Recommended Current: 5.6 Amps/Conductor @ 25°C (18 AWG)

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

awg # conductors stranding no.of
conductors
conductor
material
outer shield -
material
overall cable-
nominal
dia. (mm)
belden cable
part
number
22 and 18 4 and 2 7x30 and 19x30 6 tinned copper unshielded 5.9944 8446