Belden 9966 Cable 22 AWG 2 Conductors Communication and Instrumentation Overall Braid Shield Stranded 19x34 TC PVC Jacket Cable

Belden 9966 Cable 22 AWG 2 Conductors Communication and Instrumentation Overall Braid Shield Stranded 19x34 TC PVC Jacket Cable

Select gauge from drop-down menu for prices:

Belden 9966 Cable 22 AWG 2 Conductors Communication and Instrumentation Overall Braid Shield Stranded 19x34 TC PVC Jacket Cable

Regular price $5.22 $3.48 Sale /per Foot

Belden 9966 Cable 22 AWG 2 Conductors Communication and Instrumentation Overall Braid Shield Stranded 19x34 TC PVC Jacket Cable

Description:
• 22 AWG stranded (19x34) tinned copper conductors, nylon skin over insulation, PVC insulation, tinned copper braid shield (90% coverage), PVC jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride & Nylon
• Wall Thickness (mm): 0.254 and 0.0762
• Insulation Resistance: 500 megohms/1000 ft. @ 500 VDC

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 0.508

Mechanical Charactertistics (Overall):
• Operating Temperature Range: -20°C To +105°C
• UL Temperature Rating: 105°C
• Bulk Cable Weight: 28.276 Kg/Km
• Max. Recommended Pulling Tension: 84.516 N
• Min. Bend Radius/Minor Axis: 44.450 mm

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 10/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Military Specification: MIL-W-16878E/17 (insulated conductor)
• Other Specification: NEMA HP3

Electrical Characteristics (Overall):
• Nom. Inductance (μH/m): 0.423249
• Nom. Capacitance Conductor to Conductor (pF/m): 170.612
• Nom. Capacitance Cond. to Other Conductor & Shield (pF/m): 285.447
• Nom. Conductor DC Resistance @ 20°C (Ohm/km): 47.9026
• Nominal Outer Shield DC Resistance @ 20°C (Ohm/km): 20.3422
• Max. Operating Voltage - Non-UL: 600 V RMS
• Max. Recommended Current: 2.8 Amps/Conductor @ 25°C

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 22
# conductors 2
stranding 19x34
no. of conductors 2
conductor material tinned copper
outer shield - type braid
outer shield - material tinned copper
overall cable- nominal dia. (mm) 4.420
belden cable part number 9966

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question