Belden 8458 Cable 22 AWG 15 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable

Belden 8458 Cable 22 AWG 15 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable

Select gauge from drop-down menu for prices:

Belden 8458 Cable 22 AWG 15 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable

Regular price $7.95 $5.30 Sale /per Foot

Belden 8458 Cable 22 AWG 15 Conductors Audio Control and Instrumentation Multi Conductor Stranded 7x30 TC UnShielded Non Plenum Cable

Description:
• 22 AWG stranded (7x30) tinned copper conductors, conductors cabled, PVC insulation, PVC Jacket.

Insulation:
• Material: PVC - Polyvinyl Chloride
• Wall Thickness (mm): 0.279

Outer Jacket:
• Material: PVC - Polyvinyl Chloride
• Nom. Wall Thickness (mm): 1.016

Mechanical Charactertistics (Overall):
• Operating Tempeature Range: -20°C To +80°C
• UL Temperature Rating: 80°C (UL AWM Style 2576)
• Bulk Cable Weight: 64 lbs/1000 ft.
• Max. Recommended Pulling Tension: 135 lbs.
• Min. Bend Radius/Minor Axis: 3.250 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMG
• CEC/C(UL) Specification: CMG
• AWM Specification: UL Style 2576 (150 V 80°C)
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 04/01/2005
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes

Electrical Characteristics (Overall):
• Nom. Inductance (μH/ft): 0.17
• Nom. Capacitance Conductor to Conductor (pF/ft): 34
• Nom. Conductor DC Resistance @ 20°C (Ohm/1000 ft): 15.6
• Max. Operating Voltage - UL: 300 V RMS (CMG)
• Max. Operating Voltage - UL: 150 V RMS (UL AWM Style 2576)
• Max. Recommended Current: 2.1 Amps/Conductor @ 25°C

Flame Test:
• UL Flame Test: UL1685 FT4 Loading
• CSA Flame Test: FT4

Plenum/Non-Plenum:
• Plenum (Y/N): No

technical specification:
awg 22
# conductors 15
stranding 7x30
no. of conductors 15
conductor material tinned copper
dia. (mm) -
outer shield - material unshielded
overall cable- nominal dia. (mm) 8.001
belden cable part number 8458

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question