Belden 7852A Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable

Belden 7852A Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable

Select gauge from drop-down menu for prices:

Belden 7852A Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable

Regular price $2,458.23 $1,638.82 Sale /per Foot

Belden 7852A Cable 23 AWG 4 Pairs Category 6 Bonded-Pair Enhanced Multi Conductor Solid Bare Copper Flamarrest Jacket Cable

Description:
• CAT6+ (600MHz), 4-Bonded-Pairs, U/UTP-Unshielded, Plenum-CMP, Premise Horizontal Cable, 23 AWG Solid Bare Copper Conductors,FEP Insulation, Patented E-Spline, Ripcord, Flamarrest® Jacket.

Insulation:
• Material: FEP - Fluorinated Ethylene Propylene

Outer Jacket:
• Tramde Name: Flamarrest (R)
• Material: LS-PVC - Low Smoke Polyvinyl Chloride
• Nom. Diameter (in.): 0.255
• Outer Jacket Ripcord: Yes

Usage (Overall):
Applications:
• Premise Horizontal Cable, Gigabit Ethernet, POE, POE+,100BaseTX, 100BaseVG ANYLAN, 155ATM, 622ATM, NTSC/PAL Component or Composite Video, AES/EBU Digital Audio, AES51, RS-422, Noisy Environments.

Mechanical Characteristics (Overall):
• Storage Temperature Range: -20°C To +75°C
• Installation Temperature Range: +5°C To +50°C
• Operating Temperature Range: 0°C To +75°C
• Bulk Cable Weight: 37 lbs/1000 ft.
• Max. Recommended Pulling Tension: 45 lbs.
• Min. Bend Radius/Minor Axis: 0.500 in.
• Min. Bend/Installation: 2.250 in.

Applicable Specifications and Agency Compliance (Overall):
Applicable Standards and Environmental Programs:
• NEC/(UL) Specification: CMP
• NEC Articles: 800
• CEC/C(UL) Specification: CMP
• EU Directive 2011/65/EU (ROHS II): Yes
• EU CE Mark: Yes
• EU Directive 2000/53/EC (ELV): Yes
• EU Directive 2002/95/EC (RoHS): Yes
• EU RoHS Compliance Date (mm/dd/yyyy): 07/01/2006
• EU Directive 2002/96/EC (WEEE): Yes
• EU Directive 2003/11/EC (BFR): Yes
• CA Prop 65 (CJ for Wire and Cable): Yes
• MII Order #39 (China RoHS): Yes
• Telecommunications Standards: Category 6 - TIA 568.C.2

Electrical Characteristics (Overall):
• Nom. Mutual Capacitance (pF/ft): 15.5
• Maximum Capacitance Unbalance (pF/100m): 90
• Nominal Velocity of Propagation: VP (%): 67
• Maximum Delay (ns/100 m): 538 @ 100MHz
• Max. Delay Skew (ns/100 m): 38
• Maximum Conductor DC Resistance @ 20°C (Ohm/100 m): 8.2
• Max. Operating Voltage - UL: 300 V RMS
• Maximum DCR Unbalanced @ 20°C (%): 3

Flame Test:
• UL Flame Test: NFPA 262 Plenum Flame Test (UL910)(FT6)
• C/(UL) Flame Test: FT6
• CSA Flame Test: FT6

Plenum/Non-Plenum:
• Plenum(Y/N): Yes
• Non-Plenum Number: 7851A

technical specification:
awg 23
# pairs 4
stranding solid
no. of conductors 8
conductor material bare copper
outer shield - type -
outer shield - material unshielded
overall cable - nominal diameter (in.) 0.218 x 0.290
belden cable part number 7852A

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question