{"product_id":"belden-24501-16-awg-1-triad-600v-acic-armored-aluminum-cable","title":"Belden 24501 16 AWG 1 Triad 600V ACIC Armored Aluminum Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e: \u003cbr\u003e • 16 AWG triads stranded (7x24) tinned copper conductors, individual Beldfoil plus a polyester isolation tape, PVC insulation, PVC inner jacket, overall Beldfoil shield (100% coverage), interlocked armor, PVC outer jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeparator\u003c\/strong\u003e: \u003cbr\u003e• Separator Material: Polyester\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: \u003cbr\u003e• Material: PVC - Polyvinyl Chloride \u003cbr\u003e• Wall Thickness (mm): 0.762\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket\u003c\/strong\u003e: \u003cbr\u003e• Material: PVC - Polyvinyl Chloride \u003cbr\u003e• Nom. Dia. (mm): 9.144\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Shield Drain Wire AWG\u003c\/strong\u003e: \u003cbr\u003e• AWG: 18 \u003cbr\u003e• Stranding: 7x26 \u003cbr\u003e• Material: TC - Tinned Copper\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket\u003c\/strong\u003e: \u003cbr\u003e• Material: PVC - Polyvinyl Chloride \u003cbr\u003e• Nom. Dia. (mm): 16.764 \u003cbr\u003e• Outer Jacket Ripcord: Yes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor\u003c\/strong\u003e: \u003cbr\u003e• Armor Type: Interlocked \u003cbr\u003e• Armor Material: Aluminum\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Charactertistics (Overall)\u003c\/strong\u003e: \u003cbr\u003e• Installation Temperature Range: -25°C To +105°C \u003cbr\u003e• Wet Temperature Range: -40°C To +75°C \u003cbr\u003e• Dry Temperature Range: -40°C To +105°C \u003cbr\u003e• Bulk Cable Weight: 195 lbs\/1000 ft. \u003cbr\u003e• Max. Recommended Pulling Tension: 130 lbs. \u003cbr\u003e• Min. Bend Radius\/Minor Axis: 7.900 in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplicable Specifications and Agency Compliance (Overall)\u003c\/strong\u003e: \u003cbr\u003e\u003cstrong\u003eApplicable Standards and Environmental Programs\u003c\/strong\u003e: \u003cbr\u003e• CSA Specification: C22.2#239, Type ACIC, C22.2#174, HLBCD, C22.2#0.3, Clause 4.31 Low Acid Test \u003cbr\u003e• EU Directive 2011\/65\/EU (ROHS II): Yes \u003cbr\u003e• EU Directive 2000\/53\/EC (ELV): Yes \u003cbr\u003e• EU Directive 2002\/95\/EC (RoHS): Yes \u003cbr\u003e• EU RoHS Compliance Date (mm\/dd\/yyyy): 01\/01\/2006 \u003cbr\u003e• EU Directive 2002\/96\/EC (WEEE): Yes \u003cbr\u003e• EU Directive 2003\/11\/EC (BFR): Yes \u003cbr\u003e• CA Prop 65 (CJ for Wire and Cable): Yes \u003cbr\u003e• MII Order #39 (China RoHS): Yes \u003cbr\u003e• Other Specification: Low Acid Test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics (Overall)\u003c\/strong\u003e: \u003cbr\u003e• Nom. Conductor DC Resistance @ 20°C (Ohm\/1000 ft): 3.8 \u003cbr\u003e• Max. Operating Voltage - Other: 600 (CEC ACIC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test\u003c\/strong\u003e: \u003cbr\u003e• CSA Flame Test: FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlenum\/Non-Plenum\u003c\/strong\u003e: \u003cbr\u003e• Plenum (Y\/N): No\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# triads\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003estranding\u003c\/td\u003e\n\u003ctd\u003e7x24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of conductors\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor material\u003c\/td\u003e\n\u003ctd\u003etinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - type\u003c\/td\u003e\n\u003ctd\u003etape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter shield - material\u003c\/td\u003e\n\u003ctd\u003ealuminum foil-polyester tape\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eoverall cable- nominal dia. (mm)\u003c\/td\u003e\n\u003ctd\u003e16.764\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebelden cable part number - aluminum\u003c\/td\u003e\n\u003ctd\u003e24501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Belden Cable","offers":[{"title":"Default Title","offer_id":7162404339775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/600V_20ACIC_20Armored_20Triad_20Cable-lg_9cdb7fcc-c8e4-431d-b711-6d94c315b8b0.jpg?v=1571727964","url":"https:\/\/www.nassauelectrical.com\/products\/belden-24501-16-awg-1-triad-600v-acic-armored-aluminum-cable","provider":"NassauElectrical","version":"1.0","type":"link"}