{"product_id":"armored-power-15kv-type-mc-hl-csa-1-0-gauge-type-hl-epr-shielded-3-c-cable-tray-use-sunlight-resistant-direct-burial-abs-cwcmc-ccw","title":"General Cable Armored Power 15kV Type MC-HL CSA 1\/0 Gauge Type HL EPR Shielded 3\/C Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW®","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e:\u003cbr\u003e • Bare annealed copper per ASTM B3\u003cbr\u003e • Compact stranding per ASTM B496\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS)\u003c\/strong\u003e: Extruded thermoset semi-conductor stress control layer over the conductor per ICEA S-93-639 and UL 1072\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: 175 mils Ethylene Propylene Rubber (EPR) insulation per ICEA S-93-639 and UL 1072\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Insulation Shield (EIS)\u003c\/strong\u003e: Thermoset semi-conducting polymeric layer, free stripping from the insulation per ICEA S-93-639 and UL 1072\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield\u003c\/strong\u003e: 5 mil annealed bare copper tape with 25% overlap\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhase Identification\u003c\/strong\u003e: Color-coded polymeric identification tape laid under the shield - black, red and blue\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor\u003c\/strong\u003e:\u003cbr\u003e • Class B stranded bare annealed copper grounding conductor\u003cbr\u003e • Sized in accordance with UL 1072 and NEC Article 250\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Assembly\u003c\/strong\u003e:\u003cbr\u003e • Insulated and grounding conductors are cabled together with nonhygroscopic fillers when required\u003cbr\u003e • Binder tape is applied over the cabled core\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCCW Armor\u003c\/strong\u003e:\u003cbr\u003e • Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1072 and UL 1569\u003cbr\u003e • CCW armor conductivity meets the grounding requirements of the NEC\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e:\u003cbr\u003e • Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride(PVC), red\u003cbr\u003e • Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e:\u003cbr\u003e • CCW armored medium-voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods\u003cbr\u003e • For use on feeders and branch circuits in industrial power distribution systems per NEC Articles 328 and 330\u003cbr\u003e • For use in Class I, II and III, Divisions 1 and 2; and Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505\u003cbr\u003e • Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feet apart\u003cbr\u003e • Installed in both exposed and concealed work, wet or dry locations, directly buried or embedded in concrete\u003cbr\u003e • Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e:\u003cbr\u003e • CCW armor provides an impervious barrier to moisture, gas and liquids and meets the grounding requirements of UL 1072 and the NEC\u003cbr\u003e • Triple Extrusion: The strand shield, EPR insulation and insulation shield are all extruded in one operation\u003cbr\u003e • General Cable’s EPR insulation system has outstanding corona resistance and high dielectric strength, and it provides electrical stability under stress\u003cbr\u003e • Cable meets cold impact at -40°C\u003cbr\u003e • 105°C continuous operating temperature, wet or dry\u003cbr\u003e • 140°C emergency rating\u003cbr\u003e • 250°C short circuit rating\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eDesign Adherence\u003c\/strong\u003e:\u003cbr\u003e • ICEA S-93-639\/WC74, 5-46 kV Shielded Power Cable\u003cbr\u003e • AEIC CS8 Specification for Shielded Power Cable, 5-46 kV\u003cbr\u003e • UL 1072 Medium-Voltage Power Cables\u003cbr\u003e • UL 1569 Metal Clad Cables\u003cbr\u003e • UL 2225 Cables and Cable Fittings for Use in Hazardous Locations\u003cbr\u003e • UL 1309 Marine Shipboard Cable\u003cbr\u003e • CSA 68.10\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests\u003c\/strong\u003e:\u003cbr\u003e • ICEA T-29-520 (210,000 BTU\/hr)\u003cbr\u003e • IEEE 383 (70,000 BTU\/hr)\u003cbr\u003e • CSA FT4\u003cbr\u003e • IEEE 1202 (70,000 BTU\/hr)\u003cbr\u003e • UL 1072\u003cbr\u003e • IEC 60332-3 Category A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances\u003c\/strong\u003e:\u003cbr\u003e • UL Type MV-105 or MC-HL, SUN RES, CT USE, DIR BUR, -40°C, FT4, UL File # E90501\u003cbr\u003e • UL Listed Marine Shipboard, UL File # E85994\u003cbr\u003e • CSA Type HL, SR, FT4, -40°C, CSA File # 27161\u003cbr\u003e • American Bureau of Shipping (ABS) Listed for CWCMC\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size awg (kcmil)\u003c\/td\u003e\n\u003ctd\u003e1\/0 (19\/w)(53.5 mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e4.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal o.d. over insulation(inches)\u003c\/td\u003e\n\u003ctd\u003e0.72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal o.d. over insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e18.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebare ground (awg)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal core o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal core o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e45.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal armor o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e2.10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal armor o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e53.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e2.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e56.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapproximate net weight(lbs\/1000ft)\u003c\/td\u003e\n\u003ctd\u003e2,760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapproximate net weight(kg\/1000m)\u003c\/td\u003e\n\u003ctd\u003e4,107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(in air¹)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(direct burial²)\u003c\/td\u003e\n\u003ctd\u003e255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e9825.11003104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161619546175,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_23425c8f-57e6-4aba-b461-6ea5095f9ba4.jpg?v=1571727832","url":"https:\/\/www.nassauelectrical.com\/products\/armored-power-15kv-type-mc-hl-csa-1-0-gauge-type-hl-epr-shielded-3-c-cable-tray-use-sunlight-resistant-direct-burial-abs-cwcmc-ccw","provider":"NassauElectrical","version":"1.0","type":"link"}