{"product_id":"armored-power-1000mcm-5kv-shielded-3-c-vfd-ul-type-mc-hl-csa-type-hl-epr-cable-tray-use-sunlight-resistant-direct-burial-ul-marine-shipboard-cable-abs-cwcmc-arctic-grade-ccw","title":"General Cable Armored Power 1000MCM 5kV Shielded 3\/C VFD UL Type MC-HL CSA Type HL EPR Cable Tray Use Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC Arctic-Grade CCW®","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Bare annealed copper per ASTM B3 \u003cbr\u003e • Compact stranding per ASTM B496\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS):\u003c\/strong\u003e Extruded thermoset semi-conductor stress control layer over the conductor per ICEA S-93-639 and UL 1072\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e 115 mils Ethylene Propylene Rubber (EPR) insulation per ICEA S-93-639 and UL 1072\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Insulation Shield (EIS):\u003c\/strong\u003e Thermoset semi-conducting polymeric layer, free stripping from the insulation per ICEA S-93-639 and UL 1072\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e 5 mil annealed bare copper tape with 25% overlap\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePhase Identification:\u003c\/strong\u003e Color-coded polymeric identification tape laid under the shield – black, red and blue\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductors: \u003c\/strong\u003e\u003cbr\u003e • Three (2) split Class B stranded bare annealed copper grounding conductors \u003cbr\u003e • Sized in accordance with UL 1072 and NEC Article 250\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Assembly: \u003c\/strong\u003e\u003cbr\u003e • Insulated and grounding conductors are cabled together with non-hydroscopic fillers when required \u003cbr\u003e • Binder tape is applied over the cabled core\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCCW Armor: \u003c\/strong\u003e\u003cbr\u003e • Impervious, continuously welded and corrugated aluminum alloy sheath per UL Standards 1569 and 2225 \u003cbr\u003e • CCW armor conductivity meets the grounding requirements of NEC Article 250\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003e\u003cbr\u003e • Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride (PVC), black \u003cbr\u003e • Low temperature performance meets ASTM D746 brittleness temperature at or below -60°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e • Variable Frequency Drives: 3-conductor CCW armored cables with three (3) symmetrical grounding wires are the preferred wiring method for    use with AC motors controlled by pulse-width modulated inverters in VFD applications \u003cbr\u003e • CCW armored medium-voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring         methods \u003cbr\u003e • For use on feeders and branch circuits for power distribution systems per NEC Articles 328 and 330 \u003cbr\u003e • For use in Class I, II and III, Divisions 1 and 2; and Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505 \u003cbr\u003e • Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feet apart \u003cbr\u003e • Installed in both exposed and concealed work, wet or dry locations, directly buried or embedded in concrete \u003cbr\u003e • Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e • CCW armor provides an impervious barrier to moisture, gas and liquids and meets grounding requirements of UL 1072 and the NEC  \u003cbr\u003e • Triple Extrusion: The strand shield, EPR insulation and insulation shield are all extruded in one operation \u003cbr\u003e • General Cable’s EPR insulation system has outstanding corona resistance and high dielectric strength, and it provides electrical stability under     stress \u003cbr\u003e • Meets cold bend at -55°C \u003cbr\u003e • 105°C continuous operating temperature, wet or dry \u003cbr\u003e • 140°C emergency rating \u003cbr\u003e • 250°C short circuit rating\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesign Adherence: \u003c\/strong\u003e\u003cbr\u003e • ICEA S-93-639\/WC74, 5-46 kV Shielded Power Cables \u003cbr\u003e • AEIC CS8 Specification for Shielded Power Cable, 5 – 46 kV \u003cbr\u003e • UL 1072 Medium-Voltage Power Cables \u003cbr\u003e • UL 1569 Metal Clad Cables \u003cbr\u003e • UL 2225 Cables and Cable Fittings for Use in Hazardous Locations \u003cbr\u003e • UL 1309 Marine Shipboard Cable \u003cbr\u003e • CSA C68.10\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests: \u003c\/strong\u003e\u003cbr\u003e • ICEA T-29-520 (210,000 BTU\/hr) \u003cbr\u003e • IEEE 383 (70,000 BTU\/hr) \u003cbr\u003e • CSA FT4 \u003cbr\u003e • IEEE 1202 (70,000 BTU\/hr) \u003cbr\u003e • UL 1581 (70,000 BTU\/hr) \u003cbr\u003e • IEC 60332-3 Cat. A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e • UL Type MV-105 or UL Type MC-HL, SUN RES, CT USE, DIR BUR, -40°C, FT4, UL File # E90501 \u003cbr\u003e • UL Listed Marine Shipboard, UL File # E85994 \u003cbr\u003e • CSA Type HL, SR, FT4, -40°C, CSA File # 27161 \u003cbr\u003e • American Bureau of Shipping (ABS) Listed for CWCMC\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size. awg(kcmil)\u003c\/td\u003e\n\u003ctd\u003e\n\u003cdiv\u003e1000 (61\/W)(507 mm²)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003einsulation thickness(mils)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal o.d. over insulation(inches)\u003c\/td\u003e\n\u003ctd\u003e1.34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal o.d. over insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e34.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ebare ground(awg)\u003c\/td\u003e\n\u003ctd\u003e3 x #4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003enominal core o.d.(inches)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3.43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal core o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e87.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal armor o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e3.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal armor o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e95.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket thickness(mils)\u003c\/td\u003e\n\u003ctd\u003e85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ejacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e3.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003enominal overall o.d.(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e100.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapproximate net weight(lbs\/1000ft)\u003c\/td\u003e\n\u003ctd\u003e13,051\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eapproximate net weight(kg\/1000m)\u003c\/td\u003e\n\u003ctd\u003e19,422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 kv³ ampacity(in air¹)\u003c\/td\u003e\n\u003ctd\u003e790\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5 kv³ ampacity(direct burial²)\u003c\/td\u003e\n\u003ctd\u003e785\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e9805.10003304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161618432063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_a0034770-6313-460b-9aeb-fc63b20f5545.jpg?v=1571727831","url":"https:\/\/www.nassauelectrical.com\/products\/armored-power-1000mcm-5kv-shielded-3-c-vfd-ul-type-mc-hl-csa-type-hl-epr-cable-tray-use-sunlight-resistant-direct-burial-ul-marine-shipboard-cable-abs-cwcmc-arctic-grade-ccw","provider":"NassauElectrical","version":"1.0","type":"link"}