{"product_id":"armored-instrumentation-xlpe-16-gauge-32-triads-individual-and-overall-shield-ul-type-itc-hl-pltc-300v-sunlight-resistant-direct-burial-ul-marine-shipboard-cable-abs-cwcmc-ccw","title":"Armored Instrumentation XLPE 16 Gauge 32 Triads Individual and Overall Shield UL Type ITC-HL PLTC 300V Sunlight-Resistant Direct Burial UL Marine Shipboard Cable ABS CWCMC CCW","description":"\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e\n• Bare annealed copper per ASTM B3 \u003cbr\u003e\n• Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n• Cross-Linked Polyethylene (XLPE),\nrated 90°C per UL Standards 13 and\n2250 \u003cbr\u003e\n• Color-coded per ICEA Method 1:\npairs – black and white; triads – black,\nwhite and red. Each conductor in    each\npair or triad is printed alphanumerically\nfor easy identification\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShielded Pairs\/Triads: \u003c\/strong\u003e\u003cbr\u003e\n• Isolated and individually twisted pairs\nor triads with a Flexfoil® aluminum\/\npolyester tape shield providing   100%\ncoverage \u003cbr\u003e\n• Stranded tinned copper drain wire, two\nsizes smaller than insulated conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Assembly: \u003c\/strong\u003e\u003cbr\u003e\n• Individually shielded pairs or triads\nand communication wire are cabled\ntogether with a left-hand lay \u003cbr\u003e\n• Communication wire: 20 AWG solid\nbare copper, Cross-Linked Polyethylene\n(XLPE), rated 90°C, orange\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e \u003cbr\u003e\n• Flexfoil® aluminum\/polyester tape shield\nproviding 100% coverage \u003cbr\u003e\n• Stranded tinned copper drain wire,\nsame size as insulated conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket: \u003c\/strong\u003e\u003cbr\u003e\n• Flame-retardant Polyvinyl Chloride\n(PVC) per UL Standards 13 and 2250,\nblack \u003cbr\u003e\n• Low temperature performance meets\nASTM D746 brittleness temperature at\nor below -40°C \u003cbr\u003e\n• Nylon rip cord to facilitate jacket\nremoval\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCCW Armor: \u003c\/strong\u003e\u003cbr\u003e\n• Impervious, continuously welded and\ncorrugated aluminum alloy sheath per\nUL 1569 \u003cbr\u003e\n• CCW armor conductivity meets the\ngrounding requirements of NEC\nArticle 250\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket: \u003c\/strong\u003e\u003cbr\u003e\n• Flame-retardant, moisture- and\nsunlight-resistant Polyvinyl Chloride\n(PVC) per UL Standards 13 and 2250,  black \u003cbr\u003e\n• Low temperature performance meets\nASTM D746 brittleness temperature at\nor below -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications: \u003c\/strong\u003e\u003cbr\u003e\n• CCW armored Instrumentation cables\nwith individually shielded pairs or\ntriads and an overall shield provide\nsuperior protection and reliability\nagainst    physical damage for use in\ninstrumentation and process control\napplications requiring ITC-HL or\nPLTC wiring methods where shielding\nagainst both external  EMI and EMI\nbetween groups is required \u003cbr\u003e\n• For use as Power Limited Tray Cable\non circuits rated 150 V or less and\n5 amps or less in Class 2 or Class 3\ncircuits in accordance with NEC Article\n725 \u003cbr\u003e\n• For use as Instrumentation Tray Cable\non circuits rated 150 V or less and\n5 amps or less in accordance with\nNEC Article 727 \u003cbr\u003e\n• Recognized for use in Class I and III,\nDivisions 1 and 2; Class II, Division 2;\nor Class I, Zones 1 and 2 hazardous\nlocations per NEC Articles 501, 502,\n503    and 505  \u003cbr\u003e\n• Installed indoors or outdoors, in wet or\ndry locations, in a raceway, as aerial\ncable on a messenger, in cable trays,\nor for direct burial \u003cbr\u003e\n• Recognized for use on fixed or\nfloating offshore petroleum facilities\nas recommended by the American\nPetroleum Institute\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures: \u003c\/strong\u003e\u003cbr\u003e\n• CCW armor provides superior\nmechanical protection and an\nimpervious barrier to moisture,\ngas and liquids\n• CCW armor provides EMI shielding    performance \u003cbr\u003e\n• Meets cold impact at -40°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesign Adherence:\u003c\/strong\u003e \u003cbr\u003e\n• UL 13 Power-Limited Circuit Cables \u003cbr\u003e\n• UL 2250 Instrumentation Tray Cable \u003cbr\u003e\n• UL 1569 Metal Clad Cables \u003cbr\u003e\n• UL 1309\/CSA C22.2 No. 245 Marine\nShipboard Cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Tests: \u003c\/strong\u003e\u003cbr\u003e\n• ICEA T-29-520 (210,000 BTU\/hr) \u003cbr\u003e\n• IEEE 383 (70,000 BTU\/hr) \u003cbr\u003e\n• CSA FT4 \u003cbr\u003e\n• IEEE 1202 (70,000 BTU\/hr) \u003cbr\u003e\n• UL 1581 (70,000 BTU\/hr) \u003cbr\u003e\n• IEC 60332-3 Cat. A\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\n• UL Type PLTC, SUN RES, DIR BUR,\n-40°C, UL File # E36118 \u003cbr\u003e\n• UL Type ITC-HL, UL File # E177408 \u003cbr\u003e\n• UL Listed Marine Shipboard, UL File #\nE85994 \u003cbr\u003e\n• American Bureau of Shipping (ABS)\nListed for CWCMC \u003cbr\u003e\n• RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cdiv\u003econd. size (awg)\u003c\/div\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e16\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eno. of pairs\u003c\/td\u003e\n            \u003ctd\u003e36\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n            \u003ctd\u003e30\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003einsulation thickness (mm)\u003c\/td\u003e\n            \u003ctd\u003e0.76\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ecommunication wiresizeawg\u003c\/td\u003e\n            \u003ctd\u003e20\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ecommunication wireins. thickness(mils)\u003c\/td\u003e\n            \u003ctd\u003e15\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ecommunication wireins. thickness(mm)\u003c\/td\u003e\n            \u003ctd\u003e0.38\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003einner jacket thickness (mils)\u003c\/td\u003e\n            \u003ctd\u003e140\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003einner jacket thickness (mm)\u003c\/td\u003e\n            \u003ctd\u003e3.56\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003enominal core o.d. (inches)\u003c\/td\u003e\n            \u003ctd\u003e2.08\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cdiv\u003enominal core o.d. (mm)\u003c\/div\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e52.8\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003enominal armor o.d. (inches)\u003c\/td\u003e\n            \u003ctd\u003e2.45\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003enominal armor o.d.(mm)\u003c\/td\u003e\n            \u003ctd\u003e62.2\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ejacket thickness (mils)\u003c\/td\u003e\n            \u003ctd\u003e60\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ejacket thickness (mm)\u003c\/td\u003e\n            \u003ctd\u003e1.52\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003enominal overall o.d. (inches)\u003c\/td\u003e\n            \u003ctd\u003e2.28\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003enominal overall o.d. (mm)\u003c\/td\u003e\n            \u003ctd\u003e65.5\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ecrosssectional area¹sq. in.\u003c\/td\u003e\n            \u003ctd\u003e5.30\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003e\n            \u003cdiv\u003eapproximate net weight (lbs\/1000 ft)\u003c\/div\u003e\n            \u003c\/td\u003e\n            \u003ctd\u003e3,140\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eapproximate net weight (kg\/1000 m)\u003c\/td\u003e\n            \u003ctd\u003e4,673\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ecatalog number\u003c\/td\u003e\n            \u003ctd\u003e9150.16361202\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7161617449023,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"url":"https:\/\/www.nassauelectrical.com\/products\/armored-instrumentation-xlpe-16-gauge-32-triads-individual-and-overall-shield-ul-type-itc-hl-pltc-300v-sunlight-resistant-direct-burial-ul-marine-shipboard-cable-abs-cwcmc-ccw","provider":"NassauElectrical","version":"1.0","type":"link"}