General Cable PowrServ® Triplex 250MCM Yeshiva/AR/EYS Al Conductor Composite XLPE/HDXLPE Insulation UL Type USE-2 AR Underground Distribution Cable 600V

General Cable PowrServ® Triplex 250MCM Yeshiva/AR/EYS Al Conductor Composite XLPE/HDXLPE Insulation UL Type USE-2 AR Underground Distribution Cable 600V

Select gauge from drop-down menu for prices:

General Cable PowrServ® Triplex 250MCM Yeshiva/AR/EYS Al Conductor Composite XLPE/HDXLPE Insulation UL Type USE-2 AR Underground Distribution Cable 600V
PowrServ Triplex 250MCM Yeshiva/AR/EYS Al Conductor Composite XLPE/HDXLPE Insulation UL Type USE-2 AR Underground Distribution Cable 600V

Complete Cable: Triplex PowrServ® abuse-resistant (AR) cables consist of two phase conductors and one neutral conductor, all of which are insulated with extruded lead-free composite Cross-linked Polyethylene (XLPE) and High-Density Crosslinked Polyethylene (HDXLPE). The cables are twisted together to form a triplex assembly. These XLPE insulated cables are manufactured and tested in accordance with ANSI/ICEA S-81- 570 and UL 854, listed as a Type USE-2 cable.

Conductors: Class B or SIW compressed 1350-H19 aluminum.

Composite Insulation:The extruded lead-free cross-linked polyethylene insulation meets the requirements of ANSI/ICEA S-81-570. The extruded lead-free high-density cross-linked polyethylene meets the requirements of ASTM D1248, Type III. The two phase conductors are black, and the neutral conductor is black, identified by three extruded yellow stripes.

Phase Identification: Phase identification is provided by means of white print legend markings and sequential footage markings on one phase conductor, white print legend markings on the other phase conductor, and white print legend markings and three extruded yellow stripes on the neutral conductor.

Features and Benefits: The dual extruded composite insulation system provides a very high degree of protection against insulation damage from unclean backfill material and from cuts and abrasions that can occur during installation. For NEC-complying applications, the maximum conductor operating temperature is 90°C in wet or dry locations. This cable is also suitable for non-code-complying installations with a maximum conductor temperature of 90°C in wet or dry locations.

Applications: PowrServ AR XLPE/HDXLPE underground distribution cable is intended for use in underground systems operated at 600 volts or less.

Options:
• Aluminum 1350-H16 or H26 (¾ Hard) conductor
• Copper conductors
• Sizes 250 through 500 kcmil available with thin wall (0.040"/0.040”) insulation
• Composite PE/HDPE insulation, 75°C rating
• Other phase identification methods
• CDC® Combined Duct & Cable factory-installed in extruded HDPE duct
• MasterPak® reel-less packaging

technical specification:
phase conductor(size awg or kcmil) 250
phase conductor(no. of wires(1)) 37
phase conductor(xlpe thkn.in) 0.045
phase conductor(hdxlpe thkn.in) 0.045
neutral conductor(size awg or kcmil) 250
neutral conductor(no. of wires) 37
neutral conductor(xlpe thkn.in) 0.045
neutral conductor(hdxlpe thkn.in) 0.050
eff. o.d. in 1.61
approx. weight lb/1000ft(al) 705
approx. weight lb/1000ft(total) 959
ampacity (2)(direct buried) 380
ampacity (2)(in al total duct) 270
pkg. 1000 feet reel (3) NR 50.32
code word Yeshiva/AR/EYS