General Cable PowrServ® Duplex Al Conductor 2 AWG XLPE Insulation UL Type USE-2 XL Underground Distribution Cable 600V

General Cable PowrServ® Duplex Al Conductor 2 AWG XLPE Insulation UL Type USE-2 XL Underground Distribution Cable 600V

PowrServ Duplex Al Conductor 2 AWG XLPE Insulation UL Type USE-2 XL Underground Distribution Cable 600V

Complete Cable: Duplex 600 V PowrServ® XL cables consist of one phase conductor and one neutral conductor that are insulated with extruded lead-free Cross-linked Polyethylene (XLPE). The cables are twisted together to form a duplex assembly. These XLPE insulated cables are manufactured and tested in accordance with ANSI/ICEA S-105-692 and UL 854, listed as a Type USE-2 cable.

Conductors: Class B or SIW compressed 1350-H19 aluminum.

Insulation: The insulation is extruded lead-free Crosslinked Polyethylene (XLPE). The phase conductor is black, and the neutral conductor is black, identified by three extruded yellow stripes.

Phase Identification: Phase identification is provided by means of white print legend markings and sequential footage markings on the phase conductor and white print legend markings and three extruded yellow stripes on the neutral conductor.

Features and Benefits: 600 V PowrServ XL underground distribution cables are suitable for direct burial or installations in ducts and are resistant to abrasion, impact and sunlight. For NECcomplying applications, the maximum conductor operating temperature is 90°C in wet or dry locations. This cable is also suitable for noncode- complying installations with a maximum conductor temperature of 90°C in wet or dry locations.

Applications: PowrServ XL underground distribution cable is intended for use in underground systems operated at 600 volts or less.

Options:
• Aluminum 1350-H16 or H26 (¾ Hard) conductor
• Copper conductors
• Series 8000 aluminum alloy conductor thin wall (0.080”) insulation
• High-molecular-weight Polyethylene (PE) insulation, 75°C rating
• Type RHH/RHW-2 per UL 44
• Other phase identification methods
• CDC® Combined Duct & Cable factory-installed in extruded HDPE duct
• MasterPak® reel-less packaging

technical specification:
phase conductor(size awg or kcmil) 2
phase conductor(no. of wires(1)) 7
phase conductor(ins.thkn.inches) 0.060
neutral conductor(size awg or kcmil) 2
neutral conductor(no. of wires) 7
neutral conductor(ins. thkn.inches) 0.060
eff. o.d. inches 0.81
approx. weight lb/1000ft(al) 125
approx. weight lb/1000ft(total) 185
ampacity (2)(direct buried) 185
ampacity (2)(induct) 120
packaging 1000ft reel (3) NR 27.18
code word Everett/XP/EYS

QUESTIONS & ANSWERS