General Cable PowrServ® 2/0 AWG Hunter/XP/EYS Triplex Al Conductor XLPE Insulation UL Type USE-2 XL Underground Distribution Cable 600V

General Cable PowrServ® 2/0 AWG Hunter/XP/EYS Triplex Al Conductor XLPE Insulation UL Type USE-2 XL Underground Distribution Cable 600V

Select gauge from drop-down menu for prices:

General Cable PowrServ® 2/0 AWG Hunter/XP/EYS Triplex Al Conductor XLPE Insulation UL Type USE-2 XL Underground Distribution Cable 600V

Complete Cable: Triplex 600 V PowrServ® XL cables consist of two phase conductors and one neutral conductor, all of which are insulated with extruded lead-free Cross-linked Polyethylene (XLPE). The cables are twisted together to form a triplex assembly. These XLPE insulated cables are manufactured and tested in accordance with ANSI/ICEA S-105-692 and UL 854, listed as a Type USE-2 cable.

Conductors: Class B or SIW compressed 1350-H19 aluminum.

Insulation: The insulation is extruded lead-free Crosslinked Polyethylene (XLPE). The two phase conductors are black, and the neutral conductor is black, identified by three extruded yellow stripes.

Phase Identification: Phase identification is provided by means of white print legend markings and sequential footage markings on one phase conductor, white print legend markings on the other phase conductor, and white print legend markings and three extruded yellow stripes on the neutral conductor.

Features and Benefits: 600 V PowrServ XL underground distribution cables are suitable for direct burial or installations in ducts and are resistant to abrasion, impact and sunlight. For NEC-complying applications, the maximum conductor operating temperature is 90°C in wet or dry locations. This cable is also suitable for non-code-complying installations with a maximum conductor temperature of 90°C in wet or dry locations.

Applications: PowrServ XL underground distribution cable is intended for use in underground systems operated at 600 volts or less.

Options:
• Aluminum 1350-H16 or H26 (¾ Hard) conductor
• Copper conductors
• Series 8000 aluminum alloy conductor
• Sizes 250 through 500 kcmil available with thin wall (0.080") insulation
• High-molecular-weight Polyethylene (PE) insulation, 75°C rating
• Type RHH/RHW-2 per UL 44
• Other phase identification methods
• CDC® Combined Duct & Cable factory-installed in extruded HDPE duct
• MasterPak® reel-less packaging

technical specification:
phase conductor(size awg) 2/0
phase conductor(no. of wires(1)) 19
phase conductor(ins. thkn. inches) 0.080
neutral conductor(size awg or kcmil) 2/0
neutral conductor(no. of wires) 19
neutral conductor(ins. thkn. inches) 0.080
eff. o.d. inches 1.20
approx. weight lb/1000ft(al) 375
approx. weight lb/1000ft(total) 530
ampacity(2)(direct buried) 270
ampacity (2)(in duct) 185
packaging 1000ft reel(3) NR 40.24
code word Hunter/XP/EYS

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question