• Duplex Aluminum Service Drop Cable

    Product Details

    A good power transmission cable is one the conducts electric current without much difficulty. The Duplex Aluminum Service Dropping cable is a good example of a quality power transmission cable that am going to share with you on this post.

    This cable has four electrodes where by two of its electrodes come in a concentric-lay strand, one is an insulated phase electrode, while the remaining electrode is bare and left as a neutral conductor. The phase electrode can be coated with either the standard polyethylene insulation or the Cross-linked polyethylene jacket. This cable is made of aluminum metal compressed at 1350-H19.

    Features
    • The aluminum 1350-H19 used in making this cable boosts the conductivity of the cable as well as adding
        strength to its mechanical efficiency.
    • The Phase electrode of this cable has a standard polyethylene insulator that protects it from excessive
        moisture, dryness and stronger sunlight radiation. This unique insulation also prevents the cable from abrasion
        and cuttings, thus help in ensuring a long life of quality service.
    • This cable has a voltage rating of 600 volts, which makes it suitable for power transmission of higher voltages
        of up to 600 volts.

    The cable transmits power safely in temperatures under 900C. The maximum temperature for transmission largely depends on the insulation material used for coating the cable. When the standard polyethylene insulator jacket is used in coating, the cable can only handle high temperatures of up to 75 900C, whereas the use of cross-linked Polyethylene jacket can withstand temperatures of up to 900C.

    Applications
    The Duplex Aluminum Service cable is used as an overhead power distribution cable majorly from the service drop infrastructure to the owner’s premises.It’s also commonly used in street lighting and outdoor security lightning.

    Generally, this is a good cable that I would fully recommend for underground cabling. For a quote, or more information on this cables, and other cables, feel free to contact us and we’ll be glad to help you out.

    Code Word Phase Conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
    Size (AWG or kcmil) Stranding Insul. Thick. (mils) Size (AWG) Strand- ing Insul. Thick. (mils) Rated Strength (lbs.) XLP POLY XLP POLY
    6201 ALLOY NEUTRAL-MESSENGER
    Chihuahua 6 1 45 6 30.58 7 1110 65 65 85 70
    Vizsla 6 7 45 6 30.58 7 1110 68 68 85 70
    Harrier 4 1 45 4 48.69 7 1760 99 99 115 90
    Whippet 4 7 45 4 48.69 7 1760 103 103 115 90
    Schnauzer 2 7 45 2 77.47 7 2800 157 157 150 120
    Heeler 1/0 9 60 1/0 123.3 7 4460 250 250 205 160
    * Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.++ Designated sizes are: ACSR 6/1 diameter equivalent and AAC with equivalent resistivity per ASTM B-399 for 6201.

     

    Code Word Phase Conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
    Size (AWG or kcmil) Stranding Insul. Thick. (mils) Size (AWG) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
    AAC NEURAL-MESSENGER
    Pekingese 6 1 45 6 7 563 61 61 85 70
    Collie 6 7 45 6 7 563 64 64 85 70
    DachShund 4 1 45 4 7 881 92 92 115 90
    Spaniel 4 7 45 4 7 881 96 96 115 90
    Doberman 2 7 45 2 7 1350 147 147 150 120
    Bull 1/0 9 60 1/0 7 1990 234 234 205 160
    * Code Words For XLP Insulated Products Are Formed By Adding "/XLP" to the Conventional Code Words Above (e.g.-Chihuahua/XLP).+ Conductor Temperature of 90°C For XLP, 75°C For Poly; Ambient Temperature of 40°C; Emissivity 0.9; 2 ft./sec. Wind In Sun.

     

    Code Word Phase Conductor Bare Neutral Messenger Weight Per 1000 ft. (lbs.) Allowable Ampacity+
    Size (AWG or kcmil) Stranding Insul. Thick. (mils) Size (AWG) Strand- ing Rated Strength (lbs.) XLP POLY XLP POLY
    ACSR NEUTRAL-MESSENGER
    Setter 6 1 45 6 6/1 1190 72 72 85 70
    Shepherd 6 7 45 6 6/1 1190 75 75 85 70
    Eskimo 4 1 45 4 6/1 1860 110 110 115 90
    Terrier 4 7 45 4 6/1 1860 115 115 150 120
    Chow 2 7 45 2 6/1 2850 176 176 150 120
    Bull 1/0 9 60 1/0 6/1 4380 280 280 205 160
    * Code words for XLP insulated products are formed by adding "/XLP" to the conventional code words above (e.g.-Chihuahua/XLP).+ Conductor temperature of 90°C for XLP, 75°C for Poly; ambient temperature of 40°C; emissivity 0.9; 2 ft./sec. wind in sun.

    Quick Quote Form 