750MCM XHHW Aluminum Wire

750 MCM XHHW Aluminum Wire

Regular price $6.00 $2.94 Sale /per Foot

Applications: XHHW-2 Aluminum Conductoris principally utilized as a force dispersion link. The conveyor is most usually utilized inside an electrical raceway, for example, channel. Course is a tube or trough that channels the wiring, shielding it from obstruction that may happen from climate or different impediments. As per NEC details area 517.160, this conductor is affirmed for use in a disconnected force framework like those utilized as a part of social insurance offices. Disconnection power frameworks are favored in social insurance and restorative structures in light of the fact that the framework does not should be reset if a stage to-issue circumstance happens. This link can be introduced in an extensive variety of atmospheres as its cross-connected polyethylene coat permits it to work proficiently in unreasonably dry or wet conditions and in high warmth up to 90°C.

Search Terms: 1/0 XHHW-2 Aluminum Conductor, XHHW, XHHW Cable, XHHW-2, XHHW-2 Cable, XHHW Aluminum, XHHW-2 Aluminum, XHHW Aluminum Cable, XHHW-2 Aluminum Cable, Conduit Cable, Raceway Cable, Trough Cable, Outdoor Cable, Indoor Cable, Polyethylene Cable, Insulated Cable, Cross-linked Polyethylene Insulated Cable,Crosslinked Polyethylene, cross-linked polyethylene, Crosslinked polyethylene insulated cable, crosslinked polyethylene insulation, cross-linked polyethylene jacketed cable, insulated aluminum cable, conduit cable, cable for conduit, single conductor cable, Multi-conductor cable, high-heat resistant cable, high heat resistant cable, heat resistant cable, heat-resistant cable

Colors: Offered in black, white, red, orange, gray, yellow, green, blue. Striped pattern available in all colors. Standard is black.

Regulations:
UL Standard 44 - This Standard determines the prerequisites for single-transmitter and different conduit thermoset-protected wires and links appraised 600 V, 1000 V, 2000 V, and 5000 V, for use as per the principles of the Canadian Electrical Code CE Code Part I, CSA C22.1, in Canada, Standard for Electrical Installations, NOM-001-SEDE, in Mexico, and the National Electrical Code (NEC), NFPA-70, in the United States of America.

Federal Specification A-A-59544 – Federal specification evaluating general necessities for cable and wire, electrical (force, altered establishment).Link and wire, electrical (force, settled establishment) secured by this CID that are planned for business/modern applications. 

ICEA S-95-658 (NEMA WC 70) – An article evaluating the efficiency and safety of nonshielded 0 - 2 kV Cables

Insulation: Crosslinked polyethylene. High heat-resistant, water-resistant.

Conductors: Alumaflex® aluminum alloy conductors.

Technical Specifications:
Phase Conductor Insulation Thickness: 80 mls
Size AWG: 750
Stranding: 58
Diameter Complete Cable (O.D.) (Mils): 1071
Weight Per 1000ft Total (Lbs.): 833
Allowable Ampacity 60C (Amps): 320
Allowable Ampacity 75C (Amps): 385
Allowable Ampacity 90C (Amps): 435

QUESTIONS & ANSWERS

Have a Question?

Be the first to ask a question about this.

Ask a Question