{"product_id":"500-14-6-teck90-copper-conductor-aluminum-interlocked-armor-with-ground-600v","title":"500' 14\/6 TECK90 Copper Conductor Aluminum Interlocked Armor With Ground 600V","description":"\u003ch2\u003e\n\u003cspan data-sheets-userformat='{\"2\":769,\"3\":{\"1\":0},\"11\":3,\"12\":0}' data-sheets-value='{\"1\":2,\"2\":\"14\/6 TECK90 Copper Conductor Aluminum Interlocked Armor With Ground 600V\"}'\u003e14\/6 TECK90 Copper Conductor Aluminum Interlocked Armor With Ground 600V\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity \u003c\/b\u003e\u003cspan data-mce-fragment=\"1\"\u003efor\u003c\/span\u003e\u003cb\u003e \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/6 TECK90 Canadian Copper Building Wire 600V: \u003cstrong\u003e20 Amps\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eTeck90 is an armored interlocked electrical cable designed for many industrial applications. It is often used in petrochemical, pulp, and paper industries. It can be used as both open and concealed wiring. The wire is suitable for direct earth burial. Teck90 is used in ventilated, non-ventilated, and ladder-type cable trays. The electrical wire is fit for service entrance above and below the ground. With HL glands, it is suitable for use in various hazardous locations. The cable is rated at 90°C wet or dry. The voltage rating is 600 volts. Teck90 can serve as a cheaper alternative to installations in conduit.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/6 Teck90 Canadian Copper Construction Wire, 14\/6 Teck90, 14\/6 Teck90 Cable, 14\/6 Teck90 Wire, 14\/6 Teck90 Interlocked Armoured Cable, 14\/6 TECK90 Armored Control Cable, 14\/6 Teck90 Direct Earth Burial Wire.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA C22.2#131 \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA C22.2 #174 \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA C22.2 #138\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA C22.2 #2256\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Test FT4\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eHL\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eAG14\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eRoHS compliant\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eSUN RES\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003eCSA AG14\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductors:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe conductors are made of class B stranded bare copper. The cable also has a binder tape and aluminum interlocking armor (AIA).\u003c\/span\u003e\u003ci\u003e\u003cspan style=\"font-weight: 400;\"\u003eInsulation:\u003c\/span\u003e\u003c\/i\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eThe wire has stranded cross-linked polyethylene (XLPE) Type RW90 insulation.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eBlack Polyvinyl Chloride (PVC) outer and inner jackets are resistant to low acid gas, sunlight, and moisture. The jackets are free of lead.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSize AWG: \u003c\/strong\u003e14\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNumber of Conductors: \u003c\/strong\u003e6 \u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWeight: \u003c\/strong\u003e306 lbs per 1000 ft\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGround Size: \u003c\/strong\u003e14\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eOverall Diameter: \u003c\/strong\u003e0.793 inches\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInsulation: \u003c\/strong\u003eXLPE Type RW90\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eFeatures:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTwo or more copper conductors with XLPE (RW90) insulation, uncoated copper ground conductor, binder tape, black inner PVC jacket,, aluminum interlocking armour (AIA), and an overall Black PVC Sunlight resistant Jacket.\u003cbr\u003eTECK Cables utilize low acid gas, low flame spread PVC jacket compounds to ensure maximum safety to personnel and equipment in the event of fire. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eRated 600V\u003c\/li\u003e\n\u003cli\u003eMeets Spec's. CSA C22.2 No. 131; CSA C22.2 No. 239\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv\u003e \u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003eMinimum installation temperature is at -40°C (with proper handling procedures).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003eMaximum conductor temperature is at 90°C.\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged, flexible TECK90 Cables, originally developed for use in Canadian mines,are suitable for a wide range of Industrial and Commercial applications, including service entrance installations,above and below ground and ALL hazardous locations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTECK Cables are used in wet and dry locations, open wiring, also ventilated, nonventilated and ladder-type cable troughs, in ventilated flexible cableways, and for direct burial.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 94.3752px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003eSouthwire :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003e562248\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eNexans :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003e422246\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19.5938px;\"\u003e\u003cstrong\u003e\u003cspan\u003eHouston Wire \u0026amp; Cable :\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19.5938px;\"\u003eHW330 01406\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cspan\u003e [\/short]\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAPPLICATIONS:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003einclude pulp and paper, chemical, petroleum and other primary and secondary manufacturing industries, apartment buildings and commercial complexes where cables are subject to the risk of mechanical damage and chemical attack.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":42598423593023,"sku":"NES3956X500","price":1580.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/32_62c320c2-fd5e-4810-b438-b3fecb6673e5.png?v=1763620762","url":"https:\/\/www.nassauelectrical.com\/products\/500-14-6-teck90-copper-conductor-aluminum-interlocked-armor-with-ground-600v","provider":"NassauElectrical","version":"1.0","type":"link"}