{"product_id":"500-14-2-unshielded-vntc-tray-cable-w-ground-tc-thhn-insulation-pvc-jacket-600v","title":"500' 14\/2 Unshielded VNTC Tray Cable W\/ Ground TC THHN Insulation PVC Jacket 600V","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003ch2\u003e14\/2 Unshielded VNTC Tray Cable W\/ Ground TC THHN Insulation PVC Jacket 600V\u003c\/h2\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eTray Control Cable THHN\/PVC 600V is an electrical cable suitable for all cable trays indoors and outdoors. THHN\/PVC tray cables perform identically well in moist and dry locations. The cable is rated at 90°C for dry and 75°C for wet applications. THHN\/PVC tray cable is equally great for free air, raceways, being directly buried in the ground. The electrical cord is rated 600 V. It has crush and impact requirements of Type MC cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eCable Tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eCable Tray Types, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eElectrical Cable Tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ewire cable tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ecable tray wire, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eTHHN cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ePVC tray cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eraceway cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ethermoplastic tray cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ewire tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emulti-conductor THHN cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ecable tray types, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ePVC cable tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003econtrol cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eelectrical cable tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ecable tray systems, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ecable tray price, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003econtrol cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eelectrical tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eraceway cable tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eflexible cable tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eindustrial cable tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eunderground cable,\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e tray control cable with the ground, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003edirect burial cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eÂ tray cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2Â \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ecable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2Â \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003etray cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e14\/2 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eTC cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL 66 NEC Type TFNÂ \u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL 1277 Type TC-ER for 3+ conductors, UL File E57179\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL 1581\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• ICEA S-95-658\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL 1277 Flame Test\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• IEEE 383 Flame Test\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• IEEE 1202 Flame Test\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA FT4 Flame Test\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• EPA 40 CFR P 261 per TCLP\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• OSHA\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• RoHS\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eConductor:Â \u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFully annealed and stranded bare copper conductor with Class B stranding according to the ASTM B3 and ASTM B8. The conductor is sturdy, conductive, and highly flexible. The cable has an additional ground conductor.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eInsulation:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003ePolyvinyl Chloride insulation with transparent polyamide. The insulation is flame-retardant and resistant to chemicals, water, and ozone. It also provides mechanical support and protects the cable from mechanical breaking.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cb\u003e\u003ci\u003eJacket:\u003c\/i\u003e\u003c\/b\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eÂ Polyvinyl Chloride jacket is lead-free, flame-retardant, and sunlight resistant.Â \u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecification:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003e• Gauge: 14\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• No. Conductors: 2\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Stranding: 7\/0.0242\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Insulation Wall: 0.38\/0.010Â Â Â \u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• Jacket Wall: 0.045\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• O.D. Inches: 0.319\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003e• New Weight lb\/1000FT: 72 lbsÂ Â \u003c\/strong\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cmeta charset=\"utf-8\"\u003e\u003cspan\u003e[\/short]\u003c\/span\u003e\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":43082718380095,"sku":"NES0925X500","price":405.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/2cwith1g_37cd1584-9e9c-480b-9333-4b46ea4ae8cd.png?v=1775721252","url":"https:\/\/www.nassauelectrical.com\/products\/500-14-2-unshielded-vntc-tray-cable-w-ground-tc-thhn-insulation-pvc-jacket-600v","provider":"NassauElectrical","version":"1.0","type":"link"}