{"product_id":"2730460000-120v-surge-protector-with-alerts-40-c-to-85-c-operation","title":"2730460000 - 120V Surge Protector with Alerts, -40°C to +85°C Operation","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eEnsure your electronic devices are protected with this low-voltage surge voltage arrester, specifically crafted for single-phase surge defense Equipped with a remote alert contact, this unit offers advanced notification capabilities It meets essential standards with RoHS compliance and is certified under number E354261 by cULus This arrester operates effectively in a wide temperature range from -40 °C to +85 °C and can handle humidity levels between 5% and 95%.\u003cbr\u003e\u003cbr\u003e It boasts a maximum operating voltage of 120V and a robust short-circuit current rating of 200 kA, guaranteeing reliable surge protection in various environments.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e•Compliant with RoHS without exemptions.\u003c\/p\u003e\n\u003cp\u003e•Remote alert contact available.\u003c\/p\u003e\n\u003cp\u003e•Green and red optical function display indicators for operational status.\u003c\/p\u003e\n\u003cp\u003e•Designed for protection in power distribution segments.\u003c\/p\u003e\n\u003cp\u003e•Installation housing fits standard mounting rails.\u003c\/p\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable width=\"100%\" style=\"height: 10px; width: 90.1204%;\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Depth\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e68 mm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Height\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e111 mm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Width\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Rated Voltage U\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e120 V\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e MCOV (L-PE)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e150 V\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e SCCR\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e200 kA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e I n\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e20 kA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Connection type\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003ePUSH IN\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Protection degree\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eIP20 in installed state\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Number of poles\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Surge voltage category\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Operating altitude\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e≤ 4000 m\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Energy coordination\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eType II, Type III\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Discharge current I max (8\/20µs) wire-PE\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e50 kA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Response time\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e≤ 25 ns\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Wire connection method\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eScrew connection\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/document_ce486e15-6baa-46ce-9d15-6c9875c669de.pdf?v=1759904303\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e[\/pdf]\u003c\/embed\u003e\u003c\/p\u003e","brand":"AIM ELECTRONICS","offers":[{"title":"Default Title","offer_id":42445252362303,"sku":"2730460000","price":83.68,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/download_e580852d-ac42-40e4-b546-396c2d454d8d.jpg?v=1759904325","url":"https:\/\/www.nassauelectrical.com\/products\/2730460000-120v-surge-protector-with-alerts-40-c-to-85-c-operation","provider":"NassauElectrical","version":"1.0","type":"link"}