{"product_id":"2636950000-low-voltage-surge-arrester-for-single-phase-systems-240v","title":"2636950000 - Low Voltage Surge Arrester for Single-Phase Systems, 240V","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIntroducing a surge voltage arrester tailored for low voltage, single-phase applications, delivering crucial surge protection for your systems This unit meets ROHS standards and boasts a UL file number of E3542610000 It operates effectively between -40 °C and +85 °C and can withstand humidity levels ranging from 5% to 95% With a rated operational voltage of 240 V and a maximum continuous voltage capability of 300 V, this arrester is ideal for count-in installations.\u003cbr\u003e\u003cbr\u003e An optical display conveniently shows its operational status, making monitoring simple and effective.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e•Designed for single-phase TN environments.\u003c\/p\u003e\n\u003cp\u003e•Compliant with environmental regulations.\u003c\/p\u003e\n\u003cp\u003e•Optical function display shows operational status.\u003c\/p\u003e\n\u003cp\u003e•Compact installation housing.\u003c\/p\u003e\n\u003cp\u003e•IP20 protection degree during operation.\u003c\/p\u003e\n\u003cp\u003e•Rated for ambient temperatures.\u003c\/p\u003e\n\u003cp\u003e•No fuse necessary for certain current ratings.\u003c\/p\u003e\n\u003cp\u003e•Surge protection in power distribution systems.\u003c\/p\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable width=\"100%\" style=\"height: 10px; width: 90.1204%;\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Depth\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e91 mm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Height\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e90 mm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Width\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e18 mm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Rated Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e240 V\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Max. Continuous Voltage\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Ambient Temperature (Operational, Max)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Discharge Current I max (8\/20µs)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e65 kA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Response time \/ fallback time\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e≤ 25 ns\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Number of Poles\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Connection method\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eScrew connection\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Clamping range (min)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e1.5 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Clamping range (max)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e35 mm²\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/document_261ebc6c-f4a8-4c65-b66e-538f4b6e4053.pdf?v=1759571102\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e[\/pdf]\u003c\/embed\u003e\u003c\/p\u003e","brand":"AIM ELECTRONICS","offers":[{"title":"Default Title","offer_id":42436774527039,"sku":"2636950000","price":139.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/download_670f5774-a9c8-4734-95ab-06463bda0e76.jpg?v=1759571125","url":"https:\/\/www.nassauelectrical.com\/products\/2636950000-low-voltage-surge-arrester-for-single-phase-systems-240v","provider":"NassauElectrical","version":"1.0","type":"link"}