    Conductor:
    • Bare annealed copper per ASTM B3
    • Compact stranding per ASTM B496

    Extruded Strand Shield (ESS): Extruded thermoset semi-conductor stress control layer over the conductor per ICEA S-93-639 and UL 1072

    Insulation: 420 mils Ethylene Propylene Rubber(EPR) insulation per ICEA S-93-639 and UL 1072

    Extruded Insulation Shield (EIS): Thermoset semi-conducting polymeric layer, free stripping from the insulation per ICEA S-93-639 and UL 1072

    Shield: 5 mil annealed bare copper tape with 25% overlap

    Phase Identification: Color-coded polymeric identification tape laid under the shield - black, red and blue

    Grounding Conductor:
    • Class B stranded bare annealed copper grounding conductor
    • Sized in accordance with UL 1072 and NEC Article 250

    Cable Assembly:
    • Insulated and grounding conductors are cabled together with nonhygroscopic fillers when required
    • Binder tape is applied over the cabled core

    CCW Armor:
    • Impervious, continuously welded and corrugated aluminum alloy sheath per UL 1072 and UL 1569
    • CCW armor conductivity meets the grounding requirements of the NEC

    Jacket:
    • Flame-retardant, moisture- and sunlight-resistant Polyvinyl Chloride(PVC) per UL 1072, orange
    • Low temperature performance meets ASTM D746 brittleness temperature at or below -40°C

    Applications:
    • CCW armored medium-voltage power cables offer an economical, rugged and reliable alternative to labor-intensive cable in conduit wiring methods
    • For use on feeders and branch circuits in industrial power distribution systems per NEC Articles 328 and 330
    • For use in Class I, II and III, Divisions 1 and 2; and Class I, Zones 1 and 2 hazardous locations per NEC Articles 501, 502, 503 and 505
    • Installed on metal racks, troughs, in raceways, in cable trays or secured to supports spaced not more than six feet apart
    • Installed in both exposed and concealed work, wet or dry locations, directly buried or embedded in concrete
    • Recognized for use on fixed or floating offshore petroleum facilities as recommended by the American Petroleum Institute

    Features:
    • CCW armor provides an impervious barrier to moisture, gas and liquids and meets the grounding requirements of UL 1072 and the NEC
    • Triple Extrusion: The strand shield, EPR insulation and insulation shield are all extruded in one operation
    • General Cable’s EPR insulation system has outstanding corona resistance and high dielectric strength, and it provides electrical stability under stress
    • Cable meets cold impact at -40°C
    • 105°C continuous operating temperature, wet or dry
    • 140°C emergency rating
    • 250°C short circuit rating

    Specifications:
    Design Adherence:
    • ICEA S-93-639/WC74, 5-46 kV Shielded Power Cable
    • AEIC CS8 Specification for Shielded Power Cable, 5-46 kV
    • UL 1072 Medium-Voltage Power Cables
    • UL 1569 Metal Clad Cables
    • UL 2225 Cables and Cable Fittings for Use in Hazardous Locations
    • UL 1309 Marine Shipboard Cable
    • CSA 68.10

    Flame Tests:
    • ICEA T-29-520 (210,000 BTU/hr)
    • IEEE 383 (70,000 BTU/hr)
    • CSA FT4
    • IEEE 1202 (70,000 BTU/hr)
    • UL 1072
    • IEC 60332-3 Category A

    Compliances:
    • UL Type MV-105 or MC-HL, SUN RES, CT USE, DIR BUR, -40°C, FT4, UL File # E90501
    • UL Listed Marine Shipboard, UL File # E85994
    • CSA Type HL, SR, FT4, -40°C, CSA File # 27161
    • American Bureau of Shipping (ABS) Listed for CWCMC

    cond.
    size
    no.
    of
    cond.
    insulation
    thickness
    nominal o.d.
    over
    insulation
    bare
    grd
    nominal
    core o.d.
    nominal
    armor o.d.
    jacket
    thickness
    nominal
    overall o.d.
    approximate
    net weight
    ampacity general cable
    part number
    awg (kcmil) mils mm inches mm awg inches mm inches mm mils mm inches mm lbs/
    1000ft
    kg/
    1000m
    in air¹ direct
    burial²
    3/c with ground mc-hl or mv-105, 420 mils epr, 35 kv 133%  insulation level
    1/0 (19/w)
    (53.5 mm²)
    3 420 10.7 1.24 31.5 4 2.91 73.9 3.41 86.6 85 2.16 3.59 91.2 5,300 7,887 240 255 9875.11003104
    2/0 (19/w)
    (67.4 mm²
    3 420 10.7 1.27 32.3 4 3.02 76.7 3.63 92.2 85 2.16 3.81 96.8 6,000 8,929 275 290 9875.21003104
    4/0 (19/w)
    (107 mm²)
    3 420 10.7 1.38 35.1 3 3.23 82.0 3.80 96.5 85 2.16 3.98 101.1 7,100 10,566 360 345 9875.41003103
    250 (37/w)
    (127 mm²)
    3 420 10.7 1.43 36.3 3 3.40 86.4 3.98 101.1 85 2.16 4.16 105.7 8,100 12,054 400 410 9875.25003103
    350 (37/w)
    (177 mm²)
    3 420 10.7 1.52 38.6 2 3.51 89.2 4.10 104.1 85 2.16 4.29 109.0 9,000 13,393 490 495 9875.35003102
    500 (37/w)
    (253 mm²)
    3 420 10.7 1.64 41.7 1 3.81 96.8 4.45 113.0 85 2.16 4.63 117.6 11,100 16,519 600 590 9875.50003101

    Quick Quote Form 

    * Indicates required field

    Receive A Response In 5 Minutes Or Less During Regular Business Hours

    Captcha Image

    This product has no related products.

    NOW VIEWING

    Type MC-HL CSA Type HL EPR Armored Power 35kV Shielded 3/C UL Cable Tray Use Sunlight-Resistant Direct Burial ABS CWCMC CCW

    Request a Quote

Request a Quote

Receive A Response In 5 Minutes Or Less During Business Hours

Sign up for our newsletter

Register with Nassau today.

Subscribe to Newsletter