Conductor: 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand 

Extruded Strand Shield (ESS): Extruded thermoset semi-conducting stresscontrol layer over conductor 

Insulation: Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers 

Extruded Insulation Shield (EIS): Thermoset semi-conducting polymeric layer free stripping from insulation 

Metallic Shield: 5 mil annealed copper tape with an overlap of 25% 

Grounding Conductor: 1 bare grounding conductor may be in contact with metallic shielding tape 

Overall Jacket: Lead-free, moisture- and sunlight-resistant Low-Smoke, Zero-Halogen Polyolefin (LSZH)  

Options: STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610 

Applications: 
• Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical 
• In wet or dry locations when installed in accordance with NEC 
• In aerial, direct burial, conduit, open tray and underground duct installations 

Features: 
• Rated at 105?C 
• Excellent heat and moisture resistance 
• Outstanding corona resistance 
• Flexibility for easy handling 
• Low friction for easy pulling 
• High dielectric strength 
• Low moisture absorption 
• Electrical stability under stress 
• Low dielectric loss 
• Chemical-resistant 
• Meets cold bend test at -35?C 
• 105°C rating for continuous operation 
• 140°C rating for emergency overload conditions 
• 250°C rating for short circuit conditions 

Compliances: 
• National Electrical Code (NEC) 
• UL 1072 
• ICEA S-93-639/NEMA WC74 
• ICEA S-97-682 
• ICEA T-33-655 
• AEIC CS8 
• UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501 
• UL 1685 (70,000 BTU/hr) 
• OSHA Acceptable 
• RoHS Compliant 

Optional Flame Tests: 
• IEEE 1202 (70,000 BTU/hr)/CSA FT4 

Packaging: 
• Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit
• Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing

technical specifications:
cond.size(awg/kcmil) 1/0
nominal conductor diameter(inches) 0.34
insulation diameter inches(min.) 0.780
insulation diameter inches(max.) 0.865
ground wire(awg) 4
nominal jacket thickness(inches) 0.110
nominal jacket thickness(mm) 2.79
nominal cable(diameter ininches) 2.20
nominal cable(diameter inmm) 55.88
nominal cable(weight in lbs/1000 ft) 2811
nominal cable(weight inkg/km) 4183
copper weight(lbs/1000 ft) 1343
copper weight(kg/km) 1998
ampacity(conduit in air (1) in90?c) 195
ampacity(conduit in air (1) in105?c) 215
ampacity(underground duct (2) in 90?c) 195
ampacity(underground duct (2) in105?c) 210
ampacity(tray (3) in 90?c) 215
ampacity(tray (3) in105?c) 240
catalog number 15793.445105*