{"product_id":"1130670000-vssc6-surge-protection-device-for-hazardous-locations","title":"1130670000 - VSSC6 Surge Protection Device for Hazardous Locations","description":"\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003c\/p\u003e\u003cp\u003eIntroducing the VSSC6 RTD EX, a reliable solution for surge protection tailored for instrumentation, measurement, and control systems This device can withstand a maximum surge voltage of 18 kV and meets RoHS compliance while adhering to stringent ATEX and IECEx standards, making it suitable for both gas and dust hazardous environments Its attractive light blue hue not only looks great but also allows for straightforward screw connections.\u003cbr\u003e\u003cbr\u003e With an operating temperature range of -40 °C to +70 °C and humidity tolerance from 5% to 96%, this compact unit is built for versatility Designed for easy installation on a DIN rail, it’s the perfect choice for ensuring safety and performance in critical applications.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eFeatures and Benefits:\u003c\/strong\u003e\u003c\/p\u003e\u003cul\u003e\n\u003cp\u003e•One piece, 6.2 mm wide DIN rail module.\u003c\/p\u003e\n\u003cp\u003e•Optical identification based on protected switching type and voltage level.\u003c\/p\u003e\n\u003cp\u003e•Can be labelled or marked.\u003c\/p\u003e\n\u003cp\u003e•Surge protection for PT100 signal circuits.\u003c\/p\u003e\n\u003cp\u003e•Instrumentation and control systems.\u003c\/p\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\u003ctable width=\"100%\" style=\"height: 10px; width: 90.1204%;\"\u003e\n\u003ctbody\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Depth\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e81 mm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Height\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e88.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Width\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e12.4 mm\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Net weight\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e56.8 g\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Storage temperature\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e-40 °C...80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Operating temperature\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e-40 °C...70 °C\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Input power, max. P_I\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e0.75 W\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Input voltage, max. U_i\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e5 V\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Rated current I_N\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Protection degree\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Surge voltage category\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003eIII\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Discharge current I_max (8\/20µs) wire-PE\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Max. continuous voltage, Uc (DC)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e5 V\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Temperature class T4\/135°C\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e300 mA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003ctbody\u003e\u003ctr style=\"height: 39.2px;\"\u003e\n\u003ctd style=\"height: 39.2px; width: 40.4219%;\"\u003e Lightning test current I_imp (10\/350 µs)\u003c\/td\u003e\n\u003ctd style=\"width: 59.2209%; height: 39.2px;\"\u003e0.5 kA\u003c\/td\u003e\n\u003c\/tr\u003e\u003c\/tbody\u003e\n\u003c\/table\u003e\u003cp\u003e \u003c\/p\u003e\u003cp\u003e[pdf]\u003cembed src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/document_59b5145d-d90c-485f-957b-6cfd486d773e.pdf?v=1755870434\" width=\"\" height=\"\" type=\"application\/pdf\"\u003e[\/pdf]\u003c\/embed\u003e\u003c\/p\u003e","brand":"AIM ELECTRONICS","offers":[{"title":"Default Title","offer_id":41975009476671,"sku":"1130670000","price":81.24,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/download_078278ef-3b8a-43b2-b57a-da27c8b8a9ec.jpg?v=1755870468","url":"https:\/\/www.nassauelectrical.com\/products\/1130670000-vssc6-surge-protection-device-for-hazardous-locations","provider":"NassauElectrical","version":"1.0","type":"link"}