{"product_id":"10-3-unshielded-vntc-tray-cable-w-ground-tc-er-thhn-insulation-pvc-jacket-600v","title":"10\/3 Unshielded VNTC Tray Cable W\/ Ground TC-ER THHN Insulation PVC Jacket 600V","description":"\u003cp\u003e[short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e10\/3 Unshielded VNTC Tray Cable W\/ Ground TC-ER THHN Insulation PVC Jacket 600V\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity for \u003c\/b\u003e10 AWG 3C Unshielded VNTC Tray Cable W\/ Ground TC-ER THHN Insulation PVC Jacket 600V\u003cspan style=\"font-weight: 400;\"\u003e: 40 Amps\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eTray Control Cable THHN\/PVC 600V is an electrical cable suitable for all cable trays indoors and outdoors. THHN\/PVC tray cables perform identically well in moist and dry locations. The cable is rated at 90°C for dry and 75°C for wet applications. THHN\/PVC tray cable is equally great for free air, raceways, exposed run and being directly buried in the ground. The electrical cord is rated 600 V. It has crush and impact requirements of Type MC cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAlso Known As:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eCable Tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eCable Tray Types, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eElectrical Cable Tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ewire cable tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ecable tray wire, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eTHHN cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ePVC tray cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eraceway cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ethermoplastic tray cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ewire tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003emulti-conductor THHN cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ecable tray types, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ePVC cable tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003econtrol cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eelectrical cable tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ecable tray systems, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003ecable tray price, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003econtrol cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eelectrical tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eraceway cable tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eflexible cable tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eindustrial cable tray, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eunderground cable,\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e tray control cable with the ground, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003edirect burial cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eexposed run tray cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eER cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eER tray cable, \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e10\/3 \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003eTC-ER cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e • \u003c\/strong\u003eUL Listed as TC-ER (Exposed Run) per UL Standard 1277 and used in accordance with NEC for 3 or more conductors.\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eApproved for Class 1 or 2, Division 2 industrial hazardous locations per NEC\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eRated 90°C wet or dry to meet UL 83 for THHN\/THWN-2\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eMeets cold bend test at -25°C\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eICEA S-95-658, ICEA S-73-532\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eUL 62, UL 66, UL 83, UL1277\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eUL1685 and IEEE 383 70,000 BTU Vertical Flame Test\u003cstrong\u003e\u003cbr\u003e• \u003c\/strong\u003eUL Listed to IEEE1202 and CSA FT4 70,000 BTU Flame Test\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003ci\u003eÂ \u003c\/i\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Fully annealed bare copper Class B compressed strand per ASTM B-3 and ASTM B-8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Flame retardant PVC\/NYLON that is heat and moisture resistant per UL 62. Insulation meets requirements of Type THHN\/THWN-2 as specified by UL 83.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGround:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAssembly:\u003cbr\u003e\u003c\/strong\u003e\u003cbr\u003e• Conductors are cabled together with or without fillers as required to form a round, compact cable core with a binder tape.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e• Flame and sunlight resistant black PVC rated 90°C wet or dry per UL 1277. Ripcord provided for jackets with thickness of 60 mils or less.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003e• Black insulation with ICEA Method 4 printed numbers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e• Gauge:\u003c\/strong\u003eÂ 10 AWG\u003cbr\u003e\u003cstrong\u003e• No. Conductors:\u003c\/strong\u003eÂ 3\u003cbr\u003e\u003cstrong\u003e• Ground Gauge:\u003c\/strong\u003e 10\u003cbr\u003e\u003cstrong\u003e• Insulation Thickness:\u003c\/strong\u003e 0.026 Inches\u003cbr\u003e\u003cstrong\u003e• Jacket Thickness:\u003c\/strong\u003e 0.060 Inches\u003cbr\u003e\u003cstrong\u003e• Overall Diameter :\u003c\/strong\u003e 0.450 Inches\u003cbr\u003e\u003cstrong\u003e• New Weight lb\/1000FT:\u003c\/strong\u003e 197 Lbs\u003c\/p\u003e\n\u003ctable style=\"width: 365.266px;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"width: 347.266px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eManufacturer Equivalents\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 182px;\"\u003e\u003cstrong\u003eOmni Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 165.266px;\"\u003eA31003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":43082718117951,"sku":"NES13696X","price":2.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/files\/example_97c3ac4d-600d-4f22-8893-5234431ee7eb.png?v=1775721235","url":"https:\/\/www.nassauelectrical.com\/products\/10-3-unshielded-vntc-tray-cable-w-ground-tc-er-thhn-insulation-pvc-jacket-600v","provider":"NassauElectrical","version":"1.0","type":"link"}