{"title":"Type P Armored \u0026 Sheathed 2KV Power Cable","description":"","products":[{"product_id":"18-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"18 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e18 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 18 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 30 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 17 Amps at 110ºC, 16\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 20 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e18 AWG 1C Type P Power Cable, 18 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 18 AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.324 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.143 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 9.763\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 7.210\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 30, 110Â°C = 17, 100Â°C = 16, 95Â°C = 20\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 17 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26301801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42698802102335,"sku":"NESP201X36","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"16-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"16 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e16 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 16 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 35 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 25 Amps at 110ºC, 23\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 23 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e16 AWG 1C Type P Power Cable, 16 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 16 AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.334 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.153 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 6.121\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 4.520\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 35, 110Â°C = 25, 100Â°C = 23, 95Â°C = 23\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 18 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26301601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798792212543,"sku":"NESP201X379","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"14-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"14 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e14 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 14 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 41 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 40 Amps at 110ºC, 37\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 32 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e14 AWG 1C Type P Power Cable, 14 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 14AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.349 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.168 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 3.859\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 2.850\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 41, 110Â°C = 40, 100Â°C = 37, 95Â°C = 32\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 25 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 42px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26301401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798792474687,"sku":"NESP201X378","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"12-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"12 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e12 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 12 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 64 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 48 Amps at 110ºC, 45\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 38 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e12 AWG 1C Type P Power Cable, 12 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 12AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.368 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.187 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 2.424\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 1.790\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 64, 110Â°C = 48, 100Â°C = 45, 95Â°C = 38\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 32 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26301201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798793261119,"sku":"NESP201X3790","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"10-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"10 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e10 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 10 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 85 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 62 Amps at 110ºC, 58\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 51 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e10 AWG 1C Type P Power Cable, 10 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 10AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.388 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.207 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 1.530\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 1.130\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 85, 110Â°C = 62, 100Â°C = 58, 95Â°C = 51\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 51 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26301001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798793424959,"sku":"NESP201X3791","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"8-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"8 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e8 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 8 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 112 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 77 Amps at 110ºC, 72\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 68 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e8 AWG 1C Type P Power Cable, 8 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 8 AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.436 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.255 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.940\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.694\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 112, 110Â°C = 77, 100Â°C = 72, 95Â°C = 68\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 71 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26300801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798797455423,"sku":"NESP201X3792","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"6-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"6 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e6 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 6 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 148 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 103 Amps at 110ºC, 96\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 91 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e6 AWG 1C Type P Power Cable, 6 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 6 AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.476 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.295 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.590\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.436\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 148, 110Â°C = 103, 100Â°C = 96, 95Â°C = 91\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 108 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26300601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798815838271,"sku":"NESP201X3793","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"4-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"4 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e4 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 4 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 196 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 137 Amps at 110ºC, 128\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 121 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e4 AWG 1C Type P Power Cable, 4 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 4 AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.558 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.377 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.399\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.286\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 196, 110Â°C = 137, 100Â°C = 128, 95Â°C = 121\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 173 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 31px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 10px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 10px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 10px;\"\u003eHW26300401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798821933119,"sku":"NESP201X3794","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"2-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"2 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e2 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 2 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 259 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 181 Amps at 110ºC, 169\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 162 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e2 AWG 1C Type P Power Cable, 2 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 2 AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.624 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.443 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.244\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.175\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 259, 110Â°C = 181, 100Â°C = 169, 95Â°C = 162\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 242 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26300201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798849622079,"sku":"NESP201X3798","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"1-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"1 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e1 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 298 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 208 Amps at 110ºC, 194\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 187 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1 AWG 1C Type P Power Cable, 1 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 1 AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.665 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.484 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.195\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.140\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 298, 110Â°C = 208, 100Â°C = 194, 95Â°C = 187\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 335 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003e\u003cspan\u003eHW26300101\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798851326015,"sku":"NESP201X3799","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"1-0-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"1\/0 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e1\/0 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1\/0 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 344 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 243 Amps at 110ºC, 227\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 217 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1\/0 AWG 1C Type P Power Cable, 1\/0 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 1\/0 AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.729 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.548 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.156\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.111\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 344, 110Â°C = 243, 100Â°C = 227, 95Â°C = 217\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 422 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26310101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798857846847,"sku":"NESP201X3781","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"2-0-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"2\/0 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e2\/0 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 2\/0 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 396 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 281 Amps at 110ºC, 262\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 250 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e2\/0 AWG 1C Type P Power Cable, 2\/0 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 2\/0 AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.796 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.615 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.125\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.089\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 396, 110Â°C = 281, 100Â°C = 262, 95Â°C = 250\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 494 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26320101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eP‐1C2\/0‐2KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798858633279,"sku":"NESP201X3782","price":10.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"3-0-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"3\/0 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e3\/0 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 3\/0 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 457 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 321 Amps at 110ºC, 300\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 289 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e3\/0 AWG 1C Type P Power Cable, 3\/0 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 3\/0 AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 0.886 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.663 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.100\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.070\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 457, 110Â°C = 321, 100Â°C = 300, 95Â°C = 289\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 629 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26330101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eP‐1C3\/0‐2KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798860992575,"sku":"NESP201X3783","price":10.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"4-0-awg-1c-type-p-armored-sheathed-2kv-power-cable","title":"4\/0 AWG 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e4\/0 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 4\/0 AWG 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 528 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 376 Amps at 110ºC, 351\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 335 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e4\/0 AWG 1C Type P Power Cable, 4\/0 AWG 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 4\/0 AWG\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 1.038 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.810 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.080\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.056\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 528, 110Â°C = 376, 100Â°C = 351, 95Â°C = 335\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 822 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26340101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eP‐1C4\/0‐2KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798861418559,"sku":"NESP201X3784","price":10.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"262-mcm-1c-type-p-armored-sheathed-2kv-power-cable","title":"262 MCM 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e262 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 262 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 599 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 436 Amps at 110ºC, 407\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 382 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e262 MCM 1C Type P Power Cable, 262 MCM 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 262 MCM\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 1.111 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.888 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.067\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.046\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 599, 110Â°C = 436, 100Â°C = 407, 95Â°C = 382\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 947 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26326201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eP‐1C262‐2KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798863286335,"sku":"NESP201X3785","price":10.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"313-mcm-1c-type-p-armored-sheathed-2kv-power-cable","title":"313 MCM 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e313 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 262 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 604 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 487 Amps at 110ºC, 455\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 427 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e313 MCM 1C Type P Power Cable, 313 MCM 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 313 MCM\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 1.177 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 0.954 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.056\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.038\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 604, 110Â°C = 487, 100Â°C = 455, 95Â°C = 427\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 1115 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26331301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eP‐1C313‐2KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798865940543,"sku":"NESP201X3786","price":10.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"373-mcm-1c-type-p-armored-sheathed-2kv-power-cable","title":"373 MCM 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e373 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 373 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 674 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 553 Amps at 110ºC, 516\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 476 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e373 MCM 1C Type P Power Cable, 373 MCM 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 373 MCM\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 1.241 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 1.018 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.047\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.032\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 674, 110Â°C = 553, 100Â°C = 516, 95Â°C = 476\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 1421 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26337301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eP‐1C373‐2KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798867841087,"sku":"NESP201X3788","price":10.03,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"444-mcm-1c-type-p-armored-sheathed-2kv-power-cable","title":"444 MCM 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e444 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 444 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 750 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 630 Amps at 110ºC, 588\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 531 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e444 MCM 1C Type P Power Cable, 444 MCM 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 444 MCM\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 1.094 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 1.317 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.041\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.027\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 750, 110Â°C = 630, 100Â°C = 588, 95Â°C = 531\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 1579 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26344401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eP‐1C444‐2KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798868463679,"sku":"NESP201X3583","price":29.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"535-mcm-1c-type-p-armored-sheathed-2kv-power-cable","title":"535 MCM 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e535 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 535 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 839 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 709 Amps at 110ºC, 630\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 597 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e535 MCM 1C Type P Power Cable, 535 MCM 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 535 MCM\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 1.435 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 1.212 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.035\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.022\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 839, 110Â°C = 709, 100Â°C = 630, 95Â°C = 597\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 1978 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26353501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eP‐1C535‐2KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798870233151,"sku":"NESP201X3598","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"646-mcm-1c-type-p-armored-sheathed-2kv-power-cable","title":"646 MCM 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e646 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 646 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 937 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 783 Amps at 110ºC, 731\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 671 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e646 MCM 1C Type P Power Cable, 646 MCM 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 646 MCM\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 1.523 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 1.300 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.030\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.019\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 937, 110Â°C = 783, 100Â°C = 731, 95Â°C = 671\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 2348 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd colspan=\"2\" style=\"width: 381px; height: 21px;\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26364601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eP‐1C646‐2KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798872363071,"sku":"NESP201X359","price":50.77,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"777-mcm-1c-type-p-armored-sheathed-2kv-power-cable","title":"777 MCM 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e777 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 777 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 1048 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 881 Amps at 110ºC, 822\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 753 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e777 MCM 1C Type P Power Cable, 777 MCM 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 777 MCM\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 1.618 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 1.395 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.026\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.015\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 1048, 110Â°C = 881, 100Â°C = 822, 95Â°C = 753\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 2798 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26377701\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eP‐1C777‐2KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798879211583,"sku":"NESP201X3566","price":55.69,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"},{"product_id":"1111-mcm-1c-type-p-armored-sheathed-2kv-power-cable","title":"1111 MCM 1C Type P Armored \u0026 Sheathed 2KV Power Cable","description":"\u003ch2\u003e1111 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable\u003c\/h2\u003e\n\u003cp\u003e\u003cb\u003eAllowable Ampacity For 1111 MCM 1C Type P Armored \u0026amp; Sheathed 2KV Power Cable \u003c\/b\u003e\u003cspan style=\"font-weight: 400;\"\u003e: 1303 Amps at free air \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e110ºC, 1098 Amps at 110ºC, 1025\u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e Amps at \u003c\/span\u003e\u003cspan style=\"font-weight: 400;\"\u003e100ºC, 937 Amps at 95ºC\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eApplications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eType P Drilling Rig Marine Power Cable is an electrical cable designed for power applications in offshore and onshore drilling and petroleum facilities. Type P cables demonstrate excellent capacity in demanding conditions, including extreme cold, heat, vibration, drilling, corrosion, and mechanical stress. The electrical cables are flame-retardant and resistant to moisture.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eAlso Known As:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003e1111 MCM 1C Type P Power Cable, 1111 MCM 1C Type P Polyrad Oil Gas XLPO Power Cable.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eStandards:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Dual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Highest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Severe cold durability: exceeds CSA cold bend\/cold impact (-40\/-35°C)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Flame retardant: IEC 60332-3 Category A and IEEE 1202\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• NVE 95\/1696\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Transport Canada\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• DET Norske Veritas (DNV)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• Llloyde's Register Of Shipping (LRS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• American Bureau Of Shipping (ABS)\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• UL Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• United States Coast Guard\u003c\/span\u003e\u003c\/li\u003e\n\u003cli style=\"font-weight: 400;\"\u003e\u003cspan style=\"font-weight: 400;\"\u003e• CSA Listed As Marine Shipboard Cable\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cb\u003eConstruction:\u003c\/b\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eConductor:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11. High strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial cables. Basket weave wire armor per IEEE 1580 and UL 1309\/CSA C22.2 No. 245. Bronze standard. Tinned copper available by request.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch4\u003e\u003cstrong\u003e\u003ci\u003eInsulation\/Jacket:\u003c\/i\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e\u003cspan style=\"font-weight: 400;\"\u003eFlame Retardant Cross-linked Polyolefin meets the requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA C22.2 No. 245. 2000V\/IEC 1000V.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cb\u003eSpecifications:\u003c\/b\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cb\u003e• Size: 1111 MCM\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Number of Conductors: 1\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Unarmored Diameter: 1.954 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Under Diameter Armored : 1.668 inches \u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eVoltage Drop at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Volts\/Amp\/k ft.): 0.018\u003c\/b\u003e\n\u003c\/li\u003e\n\u003cli\u003e• \u003cb\u003eAC Resistance at 110\u003c\/b\u003e\u003cb\u003eÂ°\u003c\/b\u003e\u003cb\u003eC (Ohms\/k ft.): 0.011\u003c\/b\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Current AMPS: Free Air 110Â°C = 1303, 110Â°C = 1098, 100Â°C = 1025, 95Â°C = 937\u003c\/b\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cb\u003e• Net Weight (Lbs\/1000ft): 3982 lbs\u003c\/b\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable style=\"width: 391px; height: 59px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 21px;\"\u003e\n\u003ctd style=\"width: 381px; height: 21px;\" colspan=\"2\"\u003e\n\u003cp style=\"text-align: center;\"\u003e\u003cstrong\u003eCompatible with Manufacturer\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19px;\"\u003e\n\u003ctd style=\"width: 185.469px; height: 19px;\"\u003e\u003cstrong\u003eHouston Wire \u0026amp; Cable :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px; height: 19px;\"\u003eHW26311111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 185.469px;\"\u003e\u003cstrong\u003eICC Cable Corp :\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 189.531px;\"\u003eP‐1C1111‐2KV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e[\/short]\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e2KV Armored \u0026amp; Sheathed 110°C Gexol® Insulation Made in the USA\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003eDesigned and constructed for the demanding environments of offshore drilling and petroleum facilities located throughout the world.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003eSoft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eInsulation\/Jacket:\u003c\/strong\u003e\u003cbr\u003eFlame Retardant Cross-linked Polyolefin, meeting the requirements for IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110. 2000V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eNVE 95\/1696, FAL\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eTransport Canada\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDet Norske Veritas (DNV)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLloyd's Register of Shipping (LRS)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eAmerican Bureau of Shipping\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUL listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnited States Coast Guard\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eCSA listed as Marine Shipboard \u003ca href=\"#\"\u003eCable\u003c\/a\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eUnarmored 3\/0 and smaller has a jacket per UL 1309 \u0026amp; IEEE 1580. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHigh strand count conductors make this product extremely flexible, easier to install and more resistant to vibration than Type MC, IEC spec or commercial \u003ca href=\"#\"\u003ecable\u003c\/a\u003es.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eLower dielectric constant and higher insulation resistance reduces electrical losses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eExcellent resistance to moisture produces stable electrical properties throughout the life of the \u003ca href=\"#\"\u003ecable\u003c\/a\u003e.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eIn fire conditions, non chlorinated flame retardant system produces less toxic and less corrosive gasses.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eDual certified IEEE 1580 Type P and UL 1309\/CSA C22.2 No. 245 Type X110.\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eHighest ampacity ratings: ABS 100°C, DNV 95°C, LRS 95°C, Transport Canada 95°C\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eSevere cold durability: exceeds CSA cold bend\/cold impact (-40\/-35° C)\u003cbr\u003e\u003cspan\u003e• \u003c\/span\u003eFlame retardant: 60332-3 Category A and IEEE 1202\u003c\/p\u003e\n\u003cp\u003e*\u003ca href=\"#\"\u003eCable\u003c\/a\u003e diameters shown as nominal are subject to a ±5% manufacturing tolerance.\u003c\/p\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":42798880030783,"sku":"NESP201X3568","price":37.1,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW260-01801-lg_ca8adf79-4fa1-4bd6-83dd-ee2fe85bdd74.jpg?v=1571727130"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/type-p-armored-sheathed-2kv-power-cable-1.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}