{"title":"Superior Essex Cable EPR\/CN\/LLDPE MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable","description":"","products":[{"product_id":"superior-essex-cable-2-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-15kv-cable-e9jpt-2a6f01ca00","title":"Superior Essex Cable 2\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-2A6F01CA00","description":"Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-2A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE  Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-2A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.401 (10.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.89 (22.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e7 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.20 (30.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e625 (930)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPT-2A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164662087743,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg.jpg?v=1571728504"},{"product_id":"superior-essex-cable-2-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-25kv-cable-e9kpt-2a6f01ca00","title":"Superior Essex Cable 2\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-2A6F01CA00","description":"Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-2A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-2A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.401 (10.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.97 (24.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e7 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.28 (32.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e688 (1,024)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPT-2A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164662218815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_fa56dc85-bbd1-4c38-9b8d-cffa96933c7a.jpg?v=1571728504"},{"product_id":"superior-essex-cable-2-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-35kv-cable-e9mpt-2a6f01ca00","title":"Superior Essex Cable 2\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-2A6F01CA00","description":"Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-2A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-2A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.401 (10.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.15 (29.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e7 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.47 (37.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e863 (1,284)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPT-2A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164662349887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_2bd776fe-cad1-450e-909a-02cb590bf765.jpg?v=1571728504"},{"product_id":"superior-essex-cable-2-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-15kv-cable-e9jpt-2a3f01ca00","title":"Superior Essex Cable 2\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-2A3F01CA00","description":"Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-2A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-2A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.401 (10.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.89 (22.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e7 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.20 (30.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e624 (929)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPT-2A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164662382655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_efc2b6f7-907b-4450-b551-bf585da30789.jpg?v=1571728504"},{"product_id":"superior-essex-cable-2-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-25kv-cable-e9kpt-2a3f01ca00","title":"Superior Essex Cable 2\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-2A3F01CA00","description":"Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-2A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-2A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.401 (10.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.97 (24.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e7 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.28 (32.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e687 (1,022)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPT-2A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164662513727,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_ee57a059-2bd1-440f-8d04-fcf9a489af7d.jpg?v=1571728504"},{"product_id":"superior-essex-cable-2-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-35kv-cable-e9mpt-2a3f01ca00","title":"Superior Essex Cable 2\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-2A3F01CA00","description":"Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-2A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 2\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-2A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.401 (10.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.15 (29.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e7 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.47 (37.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e861 (1,281)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPT-2A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164662579263,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_d40097db-8ccf-4449-ae19-fd2f82eeb1c8.jpg?v=1571728504"},{"product_id":"superior-essex-cable-2-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-15kv-cable-e9jpm-2a6f01ca00","title":"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPM-2A6F01CA00","description":"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPM-2A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPM-2A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.401 (10.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.89 (22.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e20 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.21 (30.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e792 (1,178)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPM-2A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164671787071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_baa34b9c-da70-4aaf-b47d-e8333006432a.jpg?v=1571728506"},{"product_id":"superior-essex-cable-2-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-25kv-cable-e9kpm-2a6f01ca00","title":"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPM-2A6F01CA00","description":"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPM-2A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPM-2A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.451 (11.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.97 (24.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e20 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.29 (32.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e852 (1,267)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPM-2A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164671918143,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_2baef1e6-72c1-4a20-9994-cb8262da8346.jpg?v=1571728506"},{"product_id":"superior-essex-cable-2-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-35kv-cable-e9mpm-2a6f01ca00","title":"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPM-2A6F01CA00","description":"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPM-2A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPM-2A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.451 (11.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.15 (29.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e20 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.48 (37.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,026 (1,527)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPM-2A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164671983679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_7b9c70ae-7036-4bc3-8341-29205c6dace3.jpg?v=1571728506"},{"product_id":"superior-essex-cable-2-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-15kv-cable-e9jpm-2a3f01ca00","title":"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPM-2A3F01CA00","description":"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPM-2A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPM-2A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.401 (10.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.89 (22.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e20 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.21 (30.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e790 (1,176)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPM-2A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164672147519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_ad5e3266-be2f-458a-ac96-113e4b556193.jpg?v=1571728506"},{"product_id":"superior-essex-cable-2-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-25kv-cable-e9kpm-2a3f01ca00","title":"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPM-2A3F01CA00","description":"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPM-2A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90  Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPM-2A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.401 (10.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.97 (24.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e20 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.29 (32.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e850 (1,265)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPM-2A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164672245823,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_ab4601d6-39a5-4e5a-822c-1fd1cd48df1e.jpg?v=1571728506"},{"product_id":"superior-essex-cable-2-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-35kv-cable-e9mpm-2a3f01ca00","title":"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPM-2A3F01CA00","description":"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPM-2A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 2\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPM-2A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.401 (10.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.15 (29.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e20 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.48 (37.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,024 (1,524)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPM-2A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164672475199,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_6871d23f-a4d1-44c0-8daa-ed4970a4c336.jpg?v=1571728506"},{"product_id":"superior-essex-cable-250-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-15kv-cable-e9jpt-a16f01ca00","title":"Superior Essex Cable 250 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-A16F01CA00","description":"Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-A16F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE  Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-A16F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.552 (14.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.06 (26.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e13 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.38 (35.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e919 (1,367)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPT-A16F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164923772991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_d2e0549f-638f-4a0e-9d34-238aafdbec34.jpg?v=1571728580"},{"product_id":"superior-essex-cable-250-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-25kv-cable-e9kpt-a16f01ca00","title":"Superior Essex Cable 250 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-A16F01CA00","description":"Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-A16F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-A16F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.552 (14.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.14 (29.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e13 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.46 (37.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e992 (1,476)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPT-A16F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164924493887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_a6b4c42d-d184-4a28-ac39-5ba0e9c6bcb4.jpg?v=1571728580"},{"product_id":"superior-essex-cable-250-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-35kv-cable-e9mpt-a16f01ca00","title":"Superior Essex Cable 250 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-A16F01CA00","description":"Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-A16F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 250 MCM ? RCable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.educed Neutral EPR\/CN\/LLDPE \"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-A16F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.552 (14.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.31 (33.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e13 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.70 (43.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,227 (1,825)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPT-A16F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164924624959,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_4c8857b6-40bd-442d-b59b-8030f754478a.jpg?v=1571728580"},{"product_id":"superior-essex-cable-250-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-15kv-cable-e9jpt-a13f01ca00","title":"Superior Essex Cable 250 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-A13F01CA00","description":"Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-A13F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-A13F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.552 (14.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.06 (26.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e13 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.38 (35.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e917 (1,365)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPT-A13F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164924657727,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_8a4c2e87-ec82-4357-9660-51baf3dfb788.jpg?v=1571728580"},{"product_id":"superior-essex-cable-250-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-25kv-cable-e9kpt-a13f01ca00","title":"Superior Essex Cable 250 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-A13F01CA00","description":"Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-A13F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE  Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-A13F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.552 (14.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.14 (29.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e13 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.46 (37.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e990 (1,473)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPT-A13F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164924756031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_e1ae5e61-d372-4edd-839a-cc6d797c2689.jpg?v=1571728580"},{"product_id":"superior-essex-cable-250-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-35kv-cable-e9mpt-a13f01ca00","title":"Superior Essex Cable 250 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-A13F01CA00","description":"Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-A13F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 250 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-A13F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.552 (14.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.31 (33.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e13 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.70 (43.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,224 (1,822)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPT-A13F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164924788799,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_c77dfe3b-7535-45f2-8ae4-f8ec49541712.jpg?v=1571728580"},{"product_id":"superior-essex-cable-3-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-15kv-cable-e9jpt-3a6f01ca00","title":"Superior Essex Cable 3\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-3A6F01CA00","description":"Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-3A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-3A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.451 (11.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.94 (23.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e9 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.25 (31.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e708 (1,054)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPT-3A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164962799679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_7d88bdb5-3df7-4d79-a073-e7ddb1b4b0a9.jpg?v=1571728587"},{"product_id":"superior-essex-cable-3-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-25kv-cable-e9kpt-3a6f01ca00","title":"Superior Essex Cable 3\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-3A6F01CA00","description":"Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-3A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-3A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.451 (11.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.02 (25.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e9 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.35 (34.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e795 (1,182)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPT-3A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164962832447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_8e8a1c82-29cc-40ad-a8c7-009196b29144.jpg?v=1571728587"},{"product_id":"superior-essex-cable-3-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-35kv-cable-e9mpt-3a6f01ca00","title":"Superior Essex Cable 3\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-3A6F01CA00","description":"Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-3A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-3A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.451 (11.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.20 (30.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e9 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.52 (38.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e954 (1,419)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPT-3A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164962865215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_c6f78ef0-aca4-4849-b5f4-dad55ebe915f.jpg?v=1571728587"},{"product_id":"superior-essex-cable-3-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-15kv-cable-e9jpt-3a3f01ca00","title":"Superior Essex Cable 3\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-3A3F01CA00","description":"Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-3A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-3A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.451 (11.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.94 (23.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e9 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.25 (31.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e707 (1,052)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPT-3A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164962963519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_d91d4467-95f3-4573-90dc-1241b3bc3ae3.jpg?v=1571728587"},{"product_id":"superior-essex-cable-3-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-25kv-cable-e9kpt-3a3f01ca00","title":"Superior Essex Cable 3\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-3A3F01CA00","description":"Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-3A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDP Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-3A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.451 (11.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.02 (25.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e9 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.35 (34.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e793 (1,180)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPT-3A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164963127359,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_78b030ec-5aec-4772-82f5-a19af98ab38a.jpg?v=1571728587"},{"product_id":"superior-essex-cable-3-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-35kv-cable-e9mpt-3a3f01ca00","title":"Superior Essex Cable 3\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-3A3F01CA00","description":"Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-3A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 3\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-3A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.451 (11.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.20 (30.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e9 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.52 (38.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e952 (1,417)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPT-3A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164963258431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_76dcef5f-dec3-42a6-b9b6-2e84880d660c.jpg?v=1571728587"},{"product_id":"superior-essex-cable-3-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-15kv-cable-e9jpm-3a6f01ca00","title":"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPM-3A6F01CA00","description":"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPM-3A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE  Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPM-3A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.451 (11.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.94 (23.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e25 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.26 (32.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e909 (1,352)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPM-3A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164973121599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_80527d74-1151-445a-b4cb-4ef261bb9d33.jpg?v=1571728588"},{"product_id":"superior-essex-cable-3-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-25kv-cable-e9kpm-3a6f01ca00","title":"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPM-3A6F01CA00","description":"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPM-3A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPM-3A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.507 (12.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.02 (25.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e25 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.35 (34.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e982 (1,461)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPM-3A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164973154367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_d329d960-2396-4e31-886f-4a99d3ae6ce1.jpg?v=1571728588"},{"product_id":"superior-essex-cable-3-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-35kv-cable-e9mpm-3a6f01ca00","title":"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPM-3A6F01CA00","description":"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPM-3A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE  Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPM-3A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.507 (12.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.20 (30.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e25 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.53 (38.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,150 (1,711)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPMm-3A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164973252671,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_cb988691-6557-418d-a10e-2c704c93d8cc.jpg?v=1571728588"},{"product_id":"superior-essex-cable-3-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-15kv-cable-e9jpm-3a3f01ca00","title":"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPM-3A3F01CA00","description":"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPM-3A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPM-3A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.451 (11.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.94 (23.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e25 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.26 (32.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e907 (1,349)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPM-3A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164973350975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_74a6eb01-b6de-4c53-87ed-e6e696c97410.jpg?v=1571728588"},{"product_id":"superior-essex-cable-3-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-25kv-cable-e9kpm-3a3f01ca00","title":"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPM-3A3F01CA00","description":"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPM-3A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPM-3A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.451 (11.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.02 (25.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e25 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.35 (34.2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e980 (1,458)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPM-3A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164973416511,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_770d288d-c5b9-4a58-98dd-8631257dbdf2.jpg?v=1571728588"},{"product_id":"superior-essex-cable-3-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-35kv-cable-e9mpm-3a3f01ca00","title":"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPM-3A3F01CA00","description":"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPM-3A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 3\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPM-3A3F01CA00  Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.451 (11.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.20 (30.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e25 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.53 (38.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,148 (1,708)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPM-3A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164973514815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_89074981-eaf6-4457-aa58-a658a285dfb1.jpg?v=1571728588"},{"product_id":"superior-essex-cable-350-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-15kv-cable-e9jpt-a36f01ca00","title":"Superior Essex Cable 350 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-A36F01CA00","description":"Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-A36F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-A36F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.654 (16.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.16 (29.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e18 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.48 (37.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,132 (1,685)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPT-A36F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164978757695,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_46d7824d-bbff-4635-8243-de4037d451c8.jpg?v=1571728589"},{"product_id":"superior-essex-cable-350-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-25kv-cable-e9kpt-a36f01ca00","title":"Superior Essex Cable 350 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-A36F01CA00","description":"Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-A36F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-A36F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.654 (16.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.24 (31.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e18 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.56 (39.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,211 (1,801)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPT-A36F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164978790463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_7a800feb-fc7e-450d-91f7-12288e7353ab.jpg?v=1571728589"},{"product_id":"superior-essex-cable-350-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-35kv-cable-e9mpt-a36f01ca00","title":"Superior Essex Cable 350 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-A36F01CA00","description":"Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-A36F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-A36F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.654 (16.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.41 (35.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e18 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.80 (45.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,460 (2,172)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPT-A36F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164982460479,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_08e91572-898e-4285-8410-1679ea9317cd.jpg?v=1571728589"},{"product_id":"superior-essex-cable-350-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-15kv-cable-e9jpt-a33f01ca00","title":"Superior Essex Cable 350 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-A33F01CA00","description":"Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-A33F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-A33F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.654 (16.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.16 (29.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e18 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.48 (37.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,130 (1,682)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPT-A33F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164982493247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_d52c0f09-0cb9-49b0-a105-384b570335c9.jpg?v=1571728589"},{"product_id":"superior-essex-cable-350-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-25kv-cable-e9kpt-a33f01ca00","title":"Superior Essex Cable 350 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-A33F01CA00","description":"Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-A33F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-A33F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.654 (16.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.24 (31.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e18 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.56 (39.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,208 (1,798)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPT-A33F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164982526015,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_3b360984-c766-4be4-b160-dc8064895f7e.jpg?v=1571728589"},{"product_id":"superior-essex-cable-350-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-35kv-cable-e9mpt-a33f01ca00","title":"Superior Essex Cable 350 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-A33F01CA00","description":"Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-A33F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 350 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-A33F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.654 (16.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.41 (35.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e18 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.80 (45.7)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,457 (2,168)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPT-A33F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7164982624319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_1e5118ec-9b0d-4f19-a3ed-6aac7eb4c657.jpg?v=1571728589"},{"product_id":"superior-essex-cable-4-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-15kv-cable-e9jpt-4a6f01ca00","title":"Superior Essex Cable 4\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-4A6F01CA00","description":"Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-4A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type  Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-4A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.507 (12.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.00 (25.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e11 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.31 (33.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e805 (1,197)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPT-4A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165009199167,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_0f4f5177-9b57-4fb0-8e1f-cf6d44cdca21.jpg?v=1571728593"},{"product_id":"superior-essex-cable-4-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-25kv-cable-e9kpt-4a6f01ca00","title":"Superior Essex Cable 4\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-4A6F01CA00","description":"Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-4A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPT-4A6F01CA00  Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.507 (12.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.08 (27.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e11 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.41 (35.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e894 (1,330)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPT4A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165009461311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_cdc81167-4e12-4fdc-b9f8-703bf62fc436.jpg?v=1571728593"},{"product_id":"superior-essex-cable-4-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-35kv-cable-e9mpt-4a6f01ca00","title":"Superior Essex Cable 4\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-4A6F01CA00","description":"Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-4A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPT-4A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.507 (12.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.26 (32.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e11 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.58 (40.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,060 (1,577)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPT-4A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165009526847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_671a1da3-caf3-4fa9-9b2c-4b3af1633721.jpg?v=1571728593"},{"product_id":"superior-essex-cable-4-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-15kv-cable-e9jpt-4a3f01ca00","title":"Superior Essex Cable 4\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-4A3F01CA00","description":"Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-4A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPT-4A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.507 (12.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.00 (25.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e11 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.31 (33.3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e803 (1,195)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPT-4A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165009592383,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_c0bbcaa3-dc52-4776-9c15-d824f62c862e.jpg?v=1571728593"},{"product_id":"superior-essex-cable-4-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-25kv-cable-e9kpt-4a3f01ca00","title":"Superior Essex Cable 4\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-4A3F01CA00","description":"Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-4A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPT-4A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.507 (12.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.08 (27.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e11 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.41 (35.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e892 (1,327)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPT-4A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165009723455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_ad24a87c-8f99-41b7-82a1-e8ceb2a86a31.jpg?v=1571728593"},{"product_id":"superior-essex-cable-4-0-awg-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-35kv-cable-e9mpt-4a3f01ca00","title":"Superior Essex Cable 4\/0 AWG ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-4A3F01CA00","description":"Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-4A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPT-4A3F01CA00  Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.507 (12.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.26 (32.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e11 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.58 (40.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1058 (1,574)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPT-4A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165009788991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_c1a5479e-3801-4ddb-af96-f7dcf1056914.jpg?v=1571728593"},{"product_id":"superior-essex-cable-4-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-15kv-cable-e9jpm-4a6f01ca00","title":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPM-4A6F01CA00","description":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPM-4A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE  Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPM-4A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.507 (12.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.00 (25.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e32 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.35 (34.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,097 (1,632)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPM-4A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165021290559,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_89597d29-a62f-4f0d-aa56-e533979507d3.jpg?v=1571728594"},{"product_id":"superior-essex-cable-4-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-25kv-cable-e9jpm-4a3f01ca00","title":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9JPM-4A3F01CA00","description":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9JPM-4A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9JPM-4A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.512 (13.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.00 (25.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e32 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.050 (1.27)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.35 (34.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,095 (1,629)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPM-4A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165021356095,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_84aa57a0-ea35-4c5f-ab6b-b36aa8d2fde2.jpg?v=1571728594"},{"product_id":"superior-essex-cable-4-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-25kv-cable-e9kpm-4a6f01ca00","title":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPM-4A6F01CA00","description":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPM-4A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 25kV Cable E9KPM-4A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.552 (14.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.08 (27.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e32 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.45 (36.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,186 (1,765)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPM-4A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165021454399,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_7ec44407-8fcc-4e07-872f-a7db07b803af.jpg?v=1571728594"},{"product_id":"superior-essex-cable-4-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-35kv-cable-e9mpm-4a6f01ca00","title":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPM-4A6F01CA00","description":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPM-4A6F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 35kV Cable E9MPM-4A6F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.552 (14.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.26 (32.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e32 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.66 (42.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,388 (2,065)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPM-4A6F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165021585471,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_91b937f2-c7ae-4eed-9f10-5a328c3d7ca8.jpg?v=1571728594"},{"product_id":"superior-essex-cable-4-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-15kv-cable-e9jpm-4a3f01ca00","title":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPM-4A3F01CA00","description":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPM-4A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 15kV Cable E9JPM-4A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.507 (12.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.00 (25.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e32 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.35 (34.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,095 (1,629)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPM-4A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165021651007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_b7449354-ad77-42c4-ab58-4a9c8fcddf28.jpg?v=1571728594"},{"product_id":"superior-essex-cable-4-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-25kv-cable-e9kpm-4a3f01ca00","title":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPM-4A3F01CA00","description":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPM-4A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 25kV Cable E9KPM-4A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.507 (12.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.08 (27.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e32 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.45 (36.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,184 (1,761)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9KPM-4A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165021782079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_fbdbd40e-0aa8-4318-8591-fbe8fab2443d.jpg?v=1571728594"},{"product_id":"superior-essex-cable-4-0-awg-full-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-unfilled-35kv-cable-e9mpm-4a3f01ca00","title":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPM-4A3F01CA00","description":"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPM-4A3F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 4\/0 AWG Full Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Unfilled 35kV Cable E9MPM-4A3F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.507 (12.9)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.26 (32.0)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econcentric neutral no. x awg\u003c\/td\u003e\n\u003ctd\u003e32 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.66 (42.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,385 (2,060)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9MPM-4A3F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165022175295,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_39adb10b-ef3e-4178-adf7-adf4e810ce66.jpg?v=1571728594"},{"product_id":"superior-essex-cable-500-mcm-reduced-neutral-epr-cn-lldpe-mv-90-type-primary-ud-aluminum-conductors-filled-15kv-cable-e9jpt-a66f01ca00","title":"Superior Essex Cable 500 MCM ⅓ Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-A66F01CA00","description":"Superior Essex Cable 500 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-A66F01CA00\u003cmeta name=\"Keywords\" content=\"Superior Essex Cable 500 MCM ? Reduced Neutral EPR\/CN\/LLDPE Cable,Superior Essex Cable,Superior Essex Cable EPR\/CN\/LLDPE Cable, EPR\/CN\/LLDPE MV-90 Cable, EPR\/CN\/LLDPE MV-90 Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Price,MV-90 Type Primary UD 15kV-35kV Aluminum Conductors Cable Quote.\"\u003e\u003cmeta name=\"Description\" content=\"Browse our selection of Superior Essex Cable 500 MCM ? Reduced Neutral EPR\/CN\/LLDPE MV-90 Type Primary UD Aluminum Conductors Filled 15kV Cable E9JPT-A66F01CA00 Click for a free quote.\"\u003e\n\u003cp\u003eThe Superior Essex Medium Voltage Primary Underground Distribution (UD) cables consist of an Aluminum (filled or unfilled) conductor, covered with ethylene propylene rubber (EPR), a concentric neutral of helically applied copper wires, and a linear low-density polyethylene (LLDPE) jacket with 3 extruded red stripes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Excellent resistance to treeing\u003cbr\u003e • Jacket is sunlight-resistant\u003cbr\u003e • Designed to operate continuously at a conductor temperature not exceeding\u003cbr\u003e •105°C for normal operations\u003cbr\u003e • 140°C for emergency overload\u003cbr\u003e • 250°C for short circuit\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eConductor Count: \u003c\/strong\u003e1 conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003eAluminum 1350 compressed lay stranded Class B (filled or unfilled)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGauge Sizes: \u003c\/strong\u003e\u003cbr\u003e • Filled: Available in 2 AWG through 1000 kcmil\u003cbr\u003e • Unfilled: Available in 2 AWG through 1,250 kcmil\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor Strand Shield: \u003c\/strong\u003eExtruded thermoset Super-Smooth semi-conducting polymer over the conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003eEthylene Propylene Rubber (EPR)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Shield: \u003c\/strong\u003eExtruded thermoset semi-conducting polymer over the insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNeutral: \u003c\/strong\u003eHelically applied, annealed, solid bare copper wires\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLinear Low-Density Polyethylene (LLDPE)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket Marking: \u003c\/strong\u003e00000 FT SUPERIOR ESSEX XXAWG (KCMIL) AL or CU 1\/C XXKV XXX% INSUL LEVEL XXXMILS EPR AA X #BB LLDPE JKT TYPE MV-90 (UL) MADE IN USA MMDDYYYY (LIGHTNING BOLT)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging: \u003c\/strong\u003eNon-returnable wood reels in a variety of lengths and dimensions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance Compliances: \u003c\/strong\u003e\u003cbr\u003e •ASTM B-3\u003cbr\u003e • ASTM B-230\u003cbr\u003e • ASTM B-231\u003cbr\u003e • ICEA S-94-649\u003cbr\u003e • ICEA T-31-610 (water block compliance)\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL 1072 (MV-90)\u003cbr\u003e • RUS U1\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suitable for underground primary power applications\u003cbr\u003e • For wet or dry locations\u003cbr\u003e • For direct burial or in duct\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor size awg\/kcmil\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.781 (19.8)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal insulation diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.29 (32.6)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econcentric neutral no. x awg\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e25 x 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e0.055 (1.40)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal overall diameter¹ in (mm)\u003c\/td\u003e\n\u003ctd\u003e1.71 (43.4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal net weight¹ lbs\/kft (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1,537 (2,287)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (underground duct²)\u003c\/td\u003e\n\u003ctd\u003e385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity (direct buried²)\u003c\/td\u003e\n\u003ctd\u003e455\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esuperior essex cable part number\u003c\/td\u003e\n\u003ctd\u003eE9JPT-A66F01CA00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Superior Essex","offers":[{"title":"Default Title","offer_id":7165050290239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Power_20MV-90_20Type_20Primary-380-Lg_dee5e8bc-3b73-4774-9b51-74adefee9392.jpg?v=1571728597"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/superior-essex-cable-epr-cn-lldpe-mv-90-type-primary-ud-15kv-35kv-aluminum-conductors-cable.oembed?page=3","provider":"NassauElectrical","version":"1.0","type":"link"}