{"title":"Prysmian Cable 15kV - 35kV Single Conductor Airguard CSA Medium Voltage Commercial, Industrial Cables","description":"","products":[{"product_id":"prysmian-cable-250-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 250 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 250 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 250 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 250 MCM AL Cable, 250 MCM AL Price, 250 MCM AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e250 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e13.26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e25.60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e27.03\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e37.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1524\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e448\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e385\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e319 + j219\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e2006 + j74\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186382159935,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg.jpg?v=1571729017"},{"product_id":"prysmian-cable-250-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 250 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 250 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 250 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 250 MCM AL Cable, 250 MCM AL Price, 250 MCM AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e250 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e13.26\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e30.84\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e32.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e43.00\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1936\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e516\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e380\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e321 + j229\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1714 + j88\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186382225471,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_6ad95d03-1f73-415d-9e51-09b5c1378adb.jpg?v=1571729017"},{"product_id":"prysmian-cable-250-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-qxz632a","title":"Prysmian Cable 250 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXZ632A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 250 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXZ632A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 250 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXZ632A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 250 MCM CU Cable, 250 MCM CU Price, 250 MCM CU Quote, QXZ632A \"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e250 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e13.26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e25.60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e27.03\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e37.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2301\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e448\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e495\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e199 + j219\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1887 + j74\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXZ632A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186382880831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_d6b4d732-4a56-4960-9f72-09fea8f51a7f.jpg?v=1571729018"},{"product_id":"prysmian-cable-250-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-qxm244a","title":"Prysmian Cable 250 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM244A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 250 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM244A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 250 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM244A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 250 MCM CU Cable, 250 MCM CU Price, 250 MCM CU Quote, QXM244A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e250 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e13.26\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e30.84\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e32.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e43.00\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2713\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e516\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e490\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e201 + j229\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1596 + j88\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM244A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186382946367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_a109feda-d6aa-4599-bcdd-0de61b8c0c63.jpg?v=1571729018"},{"product_id":"prysmian-cable-250-mcm-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industrial-cables-qxm304a","title":"Prysmian Cable 250 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXM304A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 250 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXM304A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 250 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXM304A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 250 MCM CU Cable, 250 MCM CU Price, 250 MCM CU Quote, QXM304A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e250 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e13.26\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e35.66\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e37.08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e49.30\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3267\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e592\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e490\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e203 + j239\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1404 + j98\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM304A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186382979135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_c33f308a-f02a-4a5f-b0dd-4b026485fdd3.jpg?v=1571729018"},{"product_id":"prysmian-cable-3-0-awg-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industrial-cables-qxm302a","title":"Prysmian Cable 3\/0 AWG CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXM302A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 3\/0 AWG CU Single Conductor Airguard CSA 35kV133% Medium Voltage Commercial, Industrial Cables QXM302A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 3\/0 AWG CU Single Conductor Airguard CSA 35kV133% Medium Voltage Commercial, Industrial Cables QXM302A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 3\/0 AWG CU Cable, 3\/0 AWG CU Price, 3\/0 AWG CU Quote, QXM302A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e3\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e10.74\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e32.94\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e34.74\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e46.58\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2710\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e559\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e380\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e293 + j252\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1538 + j109\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM302A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186404933695,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_911d801f-98bc-44da-a31e-6c63da62f02c.jpg?v=1571729024"},{"product_id":"prysmian-cable-350-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 350 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 350 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 350 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 350 MCM AL Cable, 350 MCM AL Price, 350 MCM AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e350 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e15.80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e28.65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e30.07\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e39.85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1767\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e479\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e480\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e233 + j211\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1756 + j69\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186417582143,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_78c543f3-dabe-43ce-916e-c877d38d8a4c.jpg?v=1571729048"},{"product_id":"prysmian-cable-350-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 350 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 350 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 350 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 350 MCM AL Cable, 350 MCM AL Price, 350 MCM AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e350 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e15.80\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e33.38\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e34.85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e47.07\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2360\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e565\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e475\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e235 + j233\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1535 + j80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186417745983,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_e403d012-0ed9-4d4d-a024-a6092002aa8e.jpg?v=1571729048"},{"product_id":"prysmian-cable-350-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-qxj244a","title":"Prysmian Cable 350 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXJ244A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 350 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXJ244A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 350 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXJ244A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 350 MCM CU Cable, 350 MCM CU Price, 350 MCM CU Quote, QXJ244A \"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e350 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e15.80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e28.65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e30.07\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e39.85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2862\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e479\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e610\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e147 + j211\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1672 + j69\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXJ244A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186418663487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_b3d5fe7e-a679-4ab5-aecf-c82d9111c704.jpg?v=1571729048"},{"product_id":"prysmian-cable-350-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-qxm245a","title":"Prysmian Cable 350 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM245A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 350 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM245A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 350 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM245A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 350 MCM CU Cable, 350 MCM CU Price, 350 MCM CU Quote, QXM245A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e350 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e15.80\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B) \u003c\/td\u003e\n                    \u003ctd\u003e33.38\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e34.85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e47.07\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3456\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e565\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e565\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e150 + j223\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1451 + j80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM245A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186418696255,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_8c637ea0-7027-42a3-a85c-cfd932d4cd87.jpg?v=1571729048"},{"product_id":"prysmian-cable-350-mcm-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industrial-cables-qxv711a","title":"Prysmian Cable 350 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXV711A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 350 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXV711A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 350 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXV711A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 350 MCM CU Cable, 350 MCM CU Price, 350 MCM CU Quote, QXV711A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e350 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e15.80\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e38.20\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e39.62\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e51.84\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3892\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e623\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e605\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e151 + j229\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1280 + j90\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXV711A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186418729023,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_b575f583-ca38-41be-ab1e-79bfe03f8139.jpg?v=1571729048"},{"product_id":"prysmian-cable-4-0-awg-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 4\/0 AWG AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 4\/0 AWG AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 4\/0 AWG AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 4\/0 AWG AL Cable, 4\/0 AWG AL Price, 4\/0 AWG AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e4\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e12.17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e24.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e25.78\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e35.81\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1381\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e430\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e350\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e374 + j224\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e2143 + j78\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186437341247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_0bad447f-4285-4c9d-9e3e-12608b09d3de.jpg?v=1571729056"},{"product_id":"prysmian-cable-4-0-awg-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 4\/0 AWG AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 4\/0 AWG AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 4\/0 AWG AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 4\/0 AWG AL Cable, 4\/0 AWG AL Price, 4\/0 AWG AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e4\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e12.17\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e29.54\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e31.01\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e41.05\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1751\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e493\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e345\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e376 + j234\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1828 + j92\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186437472319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_444cb822-3f5e-43bb-8fc8-75a1ee08dbfc.jpg?v=1571729056"},{"product_id":"prysmian-cable-4-0-awg-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-qxm223a","title":"Prysmian Cable 4\/0 AWG CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXM223A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 4\/0 AWG CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXM223A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 4\/0 AWG CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXM223A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 4\/0 AWG CU Cable, 4\/0 AWG CU Price, 4\/0 AWG CU Quote, QXM223A \"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e4\/0 awg cu\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e12.17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e24.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e25.78\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e35.81\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2040\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e430\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e445\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e232 + j224\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e2003 + j78\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM223A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186438717503,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_76756942-2e5b-413e-95b4-b4792dbb3bef.jpg?v=1571729056"},{"product_id":"prysmian-cable-4-0-awg-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-qxm243a","title":"Prysmian Cable 4\/0 AWG CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM243A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 4\/0 AWG CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM243A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 4\/0 AWG CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM243A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 4\/0 AWG CU Cable, 4\/0 AWG CU Price, 4\/0 AWG CU Quote, QXM243A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e4\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e12.17\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e29.54\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e31.01\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e41.05\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2411\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e493\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e445\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e234 + j234\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1687 + j92\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM243A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186438783039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_1a2cecc8-3f50-47c7-8f10-2acfcd7a9202.jpg?v=1571729056"},{"product_id":"prysmian-cable-4-0-awg-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industrial-cables-qxm303a","title":"Prysmian Cable 4\/0 AWG CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXM303A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 4\/0 AWG CU Single Conductor Airguard CSA 35kV133% Medium Voltage Commercial, Industrial Cables QXM303A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 4\/0 AWG CU Single Conductor Airguard CSA 35kV133% Medium Voltage Commercial, Industrial Cables QXM303A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 4\/0 AWG CU Cable, 4\/0 AWG CU Price, 4\/0 AWG CU Quote, QXM303A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e4\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e12.17\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e34.37\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e35.79\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e48.01\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3002\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e577\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e445\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e237 + j244\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1479 + j103\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM303A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186438815807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_1ca6c000-7d77-47e7-8ff5-ab37e05e7f65.jpg?v=1571729056"},{"product_id":"prysmian-cable-500-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 500 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 500 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 500 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 500 MCM AL Cable, 500 MCM AL Price, 500 MCM AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e500 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e18.85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e31.19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e32.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e43.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2143\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e520\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e600\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e169 + j204\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1579 + j62\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186475909183,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_3bd0fb9d-60a7-4801-83bd-e9e45822b3e5.jpg?v=1571729074"},{"product_id":"prysmian-cable-500-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 500 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 500 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 500 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 500 MCM AL Cable, 500 MCM AL Price, 500 MCM AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e500 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e18.85\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e36.42\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e37.85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e50.06\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2747\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e601\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e590\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e171 + j214\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1372 + j73\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186476073023,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_299728fd-3cb3-4707-a104-7de887bf27a9.jpg?v=1571729074"},{"product_id":"prysmian-cable-500-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-qxz311a","title":"Prysmian Cable 500 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXZ311A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 500 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXZ311A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 500 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXZ311A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 500 MCM CU Cable, 500 MCM CU Price, 500 MCM CU Quote, QXZ311A \"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e500 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e18.85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e31.19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e32.61\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e43.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3704\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e520\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e765\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e109 + j204\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1521 + j62\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXZ311A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186476564543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_c46d3578-1fdc-4522-a418-c22e98c994c0.jpg?v=1571729074"},{"product_id":"prysmian-cable-500-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-qxm246a","title":"Prysmian Cable 500 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM246A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 500 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM246A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 500 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM246A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 500 MCM CU Cable, 500 MCM CU Price, 500 MCM CU Quote, QXM246A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e500 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e18.85\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e36.42\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e37.85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e50.06\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e4308\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e601\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e755\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e112 + j214\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1314 + j73\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM246A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186476728383,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_e30ce217-4479-4ac2-8ea3-910242615616.jpg?v=1571729075"},{"product_id":"prysmian-cable-500-mcm-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industrial-cables-qxv231a","title":"Prysmian Cable 500 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXV231A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 500 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXV231A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 500 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXV231A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 500 MCM CU Cable, 500 MCM CU Price, 500 MCM CU Quote, QXV231A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e500 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e18.85\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e41.25\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e42.67\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e54.89\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e4767\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e659\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e755\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e113 + j220\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1166 + j82\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXV231A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186476761151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_7313aa23-5d55-47f0-9f08-332459f4b629.jpg?v=1571729075"},{"product_id":"prysmian-cable-750-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 750 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 750 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 750 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 750 MCM AL Cable, 750 MCM AL Price, 750 MCM AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e750 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e23.29\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e35.84\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e37.26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e49.48\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2868\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e594\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e780\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e120 + j197\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1359 + j56\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186488197183,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_6c2506d1-f1b7-4332-b747-22837e840b0e.jpg?v=1571729080"},{"product_id":"prysmian-cable-750-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 750 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 750 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 750 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 750 MCM AL Cable, 750 MCM AL Price, 750 MCM AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e750 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e23.29\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e41.07\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e42.49\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e54.71\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3369\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e657\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e765\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e122 + j204\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1196 + j65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186488328255,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_6c9f51e4-029c-40b8-bb0f-69e1706a85f0.jpg?v=1571729080"},{"product_id":"prysmian-cable-750-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-qxj524a","title":"Prysmian Cable 750 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXJ524A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 750 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXJ524A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 750 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXJ524A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 750 MCM CU Cable, 750 MCM CU Price, 750 MCM CU Quote, QXJ524A \"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e750 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e23.29\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e35.84\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e37.26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e49.48\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e5258\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e594\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e990\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e81 + j197\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1322 + j56\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXJ524A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186488754239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_a8fb75bc-04b5-4aee-a70e-3dae24fe3845.jpg?v=1571729080"},{"product_id":"prysmian-cable-750-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-qxm247a","title":"Prysmian Cable 750 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM247A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 750 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM247A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 750 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM247A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 750 MCM CU Cable, 750 MCM CU Price, 750 MCM CU Quote, QXM247A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e750 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e23.29\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e41.07\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e42.49\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e54.71\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e5759\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e657\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e970\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e83 + j204\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1159 + j65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM247A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186488787007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_bee774f6-7c6d-4c22-86b2-8808c380abd7.jpg?v=1571729080"},{"product_id":"prysmian-cable-750-mcm-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industrial-cables-qxv616a","title":"Prysmian Cable 750 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXV616A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 750 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXV616A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 750 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXV616A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 750 MCM CU Cable, 750 MCM CU Price, 750 MCM CU Quote, QXV616A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e750 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e23.29\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e45.90\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e47.32\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e59.54\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e6258\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e715\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e970\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e84 + j209\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1037 + j73\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXV616A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7186488819775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_9a3d204f-1311-4dff-9536-04065913e405.jpg?v=1571729080"},{"product_id":"prysmian-cable-1-0-awg-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 1\/0 AWG AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 AWG AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 AWG AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 1\/0 AWG AL Cable, 1\/0 AWG AL Price, 1\/0 AWG AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e8.66\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e20.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e22.17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e32.21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1073\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e387\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e225\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e737 + j242\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e2783 + j93\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187774111807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_a37168de-cbae-483e-a380-69bff4624012.jpg?v=1571729318"},{"product_id":"prysmian-cable-1-0-awg-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 1\/0 AWG AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 AWG AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 AWG AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 1\/0 AWG AL Cable, 1\/0 AWG AL Price, 1\/0 AWG AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A) \u003c\/td\u003e\n                    \u003ctd\u003e8.66\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e25.98\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e27.41\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e37.44\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1415\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e450\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e225\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e739 + j253\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e2372 + j109\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187774242879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_b43dad50-c17e-492e-80be-83087cfed7a5.jpg?v=1571729318"},{"product_id":"prysmian-cable-1-0-awg-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-qxm221a","title":"Prysmian Cable 1\/0 AWG CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXM221A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 AWG CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXM221A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 AWG CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXM221A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 1\/0 AWG CU Cable, 1\/0 AWG CU Price, 1\/0 AWG CU Quote, QXM221A \"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 awg cu\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e8.66\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e20.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e22.17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e32.21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1403\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e387\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e290\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e450 + j242\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e2497 + j93\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM221A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187775127615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_cc4bc15a-eb88-49e4-b779-917d745b2f7c.jpg?v=1571729318"},{"product_id":"prysmian-cable-1-0-awg-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-qxm241a","title":"Prysmian Cable 1\/0 AWG CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM241A","description":"\n    \n        \u003ctitle\u003e Prysmian Cable 1\/0 AWG CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM241A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 AWG CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM241A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 1\/0 AWG CU Cable, 1\/0 AWG CU Price, 1\/0 AWG CU Quote, QXM241A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm)\u003c\/td\u003e\n                    \u003ctd\u003e8.66\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm)\u003c\/td\u003e\n                    \u003ctd\u003e25.98\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm)\u003c\/td\u003e\n                    \u003ctd\u003e27.41\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm)\u003c\/td\u003e\n                    \u003ctd\u003e37.44\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1746\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e450\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e290\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e452 + j253\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e2085 + j109\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM241A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187775193151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_a138b167-190c-4e37-9650-05ca12d1f3f6.jpg?v=1571729318"},{"product_id":"prysmian-cable-1-0-awg-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industrial-cables-qxm300a","title":"Prysmian Cable 1\/0 AWG CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXM300A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1\/0 AWG CU Single Conductor Airguard CSA 35kV133% Medium Voltage Commercial, Industrial Cables QXM300A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1\/0 AWG CU Single Conductor Airguard CSA 35kV133% Medium Voltage Commercial, Industrial Cables QXM300A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 1\/0 AWG CU Cable, 1\/0 AWG CU Price, 1\/0 AWG CU Quote, QXM300A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e1\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e8.66\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e30.86\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e32.28\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e43.84\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2243\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e527\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e290\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e454 + j264\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1820 + j121\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM300A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187775258687,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_3a04fd64-0ccf-4d72-a095-a207320de01f.jpg?v=1571729318"},{"product_id":"prysmian-cable-1000-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 1000 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1000 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1000 MCM AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 1000 MCM AL Cable, 1000 MCM AL Price, 1000 MCM AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e1000 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e27.20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e39.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e41.17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e53.39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3418\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e641\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e940\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e96 + j191\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1220 + j51\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187824771135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_c5d50779-8406-4d84-a278-7f9b8e37b89b.jpg?v=1571729340"},{"product_id":"prysmian-cable-1000-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 1000 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1000 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1000 MCM AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 1000 MCM AL Cable, 1000 MCM AL Price, 1000 MCM AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e1000 MCM AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e27.20\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e44.98\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e46.41\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e58.62\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3955\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e704\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e920\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e98 + j197\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1084 + j60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187824836671,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_f9033db0-41ae-4a00-a971-27db44c8dadf.jpg?v=1571729340"},{"product_id":"prysmian-cable-1000-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-qxz047a","title":"Prysmian Cable 1000 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXZ047A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1000 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXZ047A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1000 MCM CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXZ047A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 1000 MCM CU Cable, 1000 MCM CU Price, 1000 MCM CU Quote, QXZ047A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e1000 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e27.20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e39.75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e41.17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e53.39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e6551\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e641\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e1185\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e67 + j191\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1193 + j51\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXZ047A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187825360959,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_3f0374e1-f70d-4683-97ff-a9103347ca9c.jpg?v=1571729340"},{"product_id":"prysmian-cable-1000-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-qxm248a","title":"Prysmian Cable 1000 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM248A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1000 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM248A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1000 MCM CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM248A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 1000 MCM CU Cable, 1000 MCM CU Price, 1000 MCM CU Quote, QXM248A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e1000 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e27.20\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e44.98\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e46.41\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e58.62\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e7088\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e704\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e1160\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e67 + j190\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1057 + j60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM248A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187825426495,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_b3e3c5bc-9ee7-4c76-afee-82ff88c4f2db.jpg?v=1571729340"},{"product_id":"prysmian-cable-1000-mcm-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industrial-cables-qxm305a","title":"Prysmian Cable 1000 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXM305A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 1000 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXM305A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 1000 MCM CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXM305A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 1000 MCM CU Cable, 1000 MCM CU Price, 1000 MCM CU Quote, QXM305A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e1000 MCM CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e27.20\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e49.81\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e51.23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e63.45\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e7621\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e762\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e1160\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e71 + j202\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e953 + j67\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM305A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187825524799,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_ea34f1cf-8248-4fe6-8703-bb4e4491d090.jpg?v=1571729340"},{"product_id":"prysmian-cable-2-0-awg-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 2\/0 AWG AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2\/0 AWG AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2\/0 AWG AL Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 2\/0 AWG AL Cable, 2\/0 AWG AL Price, 2\/0 AWG AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e2\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e9.55\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e21.69\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e23.16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e33.20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1161\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e399\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e260\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e586 + j236\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e2538 + j88\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187887587391,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_4802fc9f-c19c-4e64-a3d3-c733acd86b35.jpg?v=1571729362"},{"product_id":"prysmian-cable-2-0-awg-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-code-dne","title":"Prysmian Cable 2\/0 AWG AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2\/0 AWG AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2\/0 AWG AL Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables CODE DNE. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 2\/0 AWG AL Cable, 2\/0 AWG AL Price, 2\/0 AWG AL Quote, CODE DNE\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e2\/0 AWG AL\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e9.55\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e26.92\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e28.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e38.43\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1506\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e462\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e260\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e588 + j247\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e2160 + j104\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eCODE DNE\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187887718463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_54678f81-7f8a-4b6d-8e13-29ca3567ea60.jpg?v=1571729362"},{"product_id":"prysmian-cable-2-0-awg-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industrial-cables-qxm222a","title":"Prysmian Cable 2\/0 AWG CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXM222A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2\/0 AWG CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXM222A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2\/0 AWG CU Single Conductor Airguard CSA 15kV 133% Medium Voltage Commercial, Industrial Cables QXM222A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 2\/0 AWG CU Cable, 2\/0 AWG CU Price, 2\/0 AWG CU Quote, QXM222A \"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e2\/0 awg cu\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e220\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e9.55\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e21.69\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e23.16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e33.20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1579\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e399\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e335\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e360 + j236\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e2313 + j88\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM222A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187888668735,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_35a04598-180e-49a0-a1e6-f046391e4c18.jpg?v=1571729363"},{"product_id":"prysmian-cable-2-0-awg-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industrial-cables-qxm242a","title":"Prysmian Cable 2\/0 AWG CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM242A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2\/0 AWG CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM242A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2\/0 AWG CU Single Conductor Airguard CSA 25kV 133% Medium Voltage Commercial, Industrial Cables QXM242A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 2\/0 AWG CU Cable, 2\/0 AWG CU Price, 2\/0 AWG CU Quote, QXM242A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e2\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e9.55\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e26.92\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e28.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e38.43\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1924\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e462\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e330\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e362 + j247\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1935 + j104\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM242A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187888734271,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_c25dcfac-ee9a-4a8c-9a5c-f87c9660370d.jpg?v=1571729363"},{"product_id":"prysmian-cable-2-0-awg-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industrial-cables-qxm301a","title":"Prysmian Cable 2\/0 AWG CU Single Conductor Airguard CSA 35kV 133% Medium Voltage Commercial, Industrial Cables QXM301A","description":"\n    \n        \u003ctitle\u003ePrysmian Cable 2\/0 AWG CU Single Conductor Airguard CSA 35kV133% Medium Voltage Commercial, Industrial Cables QXM301A\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian Cable 2\/0 AWG CU Single Conductor Airguard CSA 35kV133% Medium Voltage Commercial, Industrial Cables QXM301A. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable, Single Conductor Cable, Airguard CSA Cable, Medium Voltage Commercial Cable, Industrial Cable, Prysmian Cable Price, Single Conductor Cable Price, Airguard CSA Cable Price, Medium Voltage Commercial Cable Price, Industrial Cable Price, Prysmian Cable Quote, Single Conductor Cable Quote, Airguard CSA Cable Quote, Medium Voltage Commercial Cable Quote, Industrial Cable Quote, 2\/0 AWG CU Cable, 2\/0 AWG CU Price, 2\/0 AWG CU Quote, QXM301A\"\u003e\n    \n    \n        \u003cp\u003eSingle conductor cable with stranded copper conductor, extruded insulation system consisting of a thermosetting semiconducting conductor shield, high dielectric strength EPROTENAX® EPR insulation, thermosetting semiconducting insulation shield, helically applied bare copper tape shield, separator tape, foamed polymeric Air Bag™ layer for superior mechanical protection, a Drylam® layer consisting of a longitudinally applied aluminum tape and an extruded oil and hydrocarbon resistant polymer, and overall non-leaded sun resistant PVC jacket.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications: \u003c\/strong\u003e\u003cbr\u003e\n        • CSA -CSA C68.10\u003cbr\u003e\n        • CSA - C22.2 No.0.3\u003cbr\u003e\n        • CSA - C22.2 No. 230\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRatings:\u003c\/strong\u003e\u003cbr\u003e\n        • Cold Impact\/Bend Test (-40°C) 105°C\u003cbr\u003e\n        • Sunlight Resistant FT4\u003cbr\u003e\n        • TC (1\/0 AWG and Larger)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Class B Compact concentric strand aluminum alloy 1350 or soft drawn annealed copper per ASTM.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductor Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield which is free stripping from the conductor and bonded to the insulation.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Natural high dielectric strength EPROTENAX® EPR-based insulation, combined with other materials and agents that enhance the electrical and mechanical characteristics assuring extended cable life.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Shield:\u003c\/strong\u003e Extruded thermosetting semiconducting shield with controlled adhesion to the insulation providing the required balance between electrical integrity and ease of stripping.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e Helically applied non-magnetic copper tape(s) over the insulation shield followed by a separator tape.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMechanical Protection:\u003c\/strong\u003e High strength and high crush resistant Air Bag™ Layer extruded over the core.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eChemical Protection:\u003c\/strong\u003e A layer of Drylam® which consists of an aluminum tape   a chemical resistant extruded polymer layer is applied.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Sunlight resistant polyvinyl chloride (PVC), non-leaded jacket.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size\u003c\/td\u003e\n                    \u003ctd\u003e2\/0 AWG CU\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness (mils)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter (mm) (A)\u003c\/td\u003e\n                    \u003ctd\u003e9.55\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation diameter (mm) (B)\u003c\/td\u003e\n                    \u003ctd\u003e31.75\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation shield diameter (mm) (C)\u003c\/td\u003e\n                    \u003ctd\u003e33.17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eoverall jacket diameter (mm) (D)\u003c\/td\u003e\n                    \u003ctd\u003e45.39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight (lkg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2475\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eminimum bending radius (mm)\u003c\/td\u003e\n                    \u003ctd\u003e545\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity in air and cable tray‡105°c\u003c\/td\u003e\n                    \u003ctd\u003e330\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m) pos\/neg seq\u003c\/td\u003e\n                    \u003ctd\u003e364 + j259\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance in air and cable tray (μω\/m)zero seq\u003c\/td\u003e\n                    \u003ctd\u003e1697 + j115\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian cable part number\u003c\/td\u003e\n                    \u003ctd\u003eQXM301A\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7187888767039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_20CSA_20Cable-lg_9b8f225e-8a40-4bd4-a4a6-c0cb5236a736.jpg?v=1571729363"},{"product_id":"prysmian-cable-15kv-35kv-single-conductor-airguard-csa-medium-voltage-commercial-industrial-cables","title":"Prysmian Cable 15kV - 35kV Single Conductor Airguard CSA Medium Voltage Commercial, Industrial Cables","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eThis cable has a single conductor. Cables with one conductor are also referred to as a single-phase conductor, deployed in single-phased. 15-35kv Prysmian is made of compacted Class B concentrically stranded aluminum 1350 and annealed drawn copper. The single conductor is shielded with an extruded thermosetting semi-conductor, which forms a free strip from the conductor and it bonds to the insulation. This cable is insulated with an EPR that has a high dielectric strength and is also shielded with an extruded thermosetting semi-conducting layer offering a balanced electrical integrity and the ease of stripping. \u003c\/p\u003e\n\u003cp\u003eInsulation is covered with a metallic shielding, which is made of a non-magnetic copper tape helically applied over the insulation shield and wrapped with a separating tape. The assembly is coated with a strong Air Bag and compacted with a layer of Drylam made of aluminum tape acting as a chemical protector. It is jacketed with Polyvinyl Chloride (PVC); a free-lead compound.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards and Approvals\u003c\/strong\u003e \u003cbr\u003eThis type of prysmian cable is quality power cable that conforms to the following specification standards:\u003c\/p\u003e\n\u003cp style=\"margin-left: 40px;\"\u003e1.CSA - CSA C68.10 \u003cbr\u003e 2.CSA - C22.2 number 0.3 \u003cbr\u003e 3.CSA – C22.2 number 230\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e \u003cbr\u003eThe 15-35kV Prysmian cable is a single conductor made of aluminum 1350 or soft drawn copper conductor. Aluminum and soft drawn copper made cables are known to be flexible and lightweight. Lightweight power cables will relieve you from using excessive effort in lifting the cable especially during installation. Flexibility is a very important cable aspect that should be considered since they require less time to install as they can be folded easily into smaller portions as compared to stiff and rigid cables, which would even break when subjected to continuous bending.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShielding\u003c\/strong\u003e \u003cbr\u003eThis cable has a triple shielding extrusions; conductor shield, insulation shield and the metallic shield. Shielding helps in controlling the amount of stress acting on the cable thus improving its electrical conductivity. It offers an additional mechanical protection to the cable. Thermosetting semi-conducting shields do not permit transmission of electrical power hence maintaining high dielectric strength.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e \u003cbr\u003eInsulation of this cable ensures that the safety of the user is not at risk and that of the cable as well. Ethylene Propylene Rubber (EPR) is a semi-conducting compound that will protect the user from unnecessary power shocks. The conductor is insulated with an EPR to protect it from mechanical and chemical damages that may attack the cable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacketing\u003c\/strong\u003e \u003cbr\u003ePolyvinyl Chloride (PVC) jacketing provides an additional mechanical and chemical protection to the cable. It has an Air Bag that is strong enough to withstand crushing and abrasion, and with Drylam layer that is made of aluminum tape keeping the cable from chemical damages. This PVC is lead-free and thus environmental friendly as it releases less smoke in case of fire outbreak.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e \u003cbr\u003ePrysmian 15kV-35kV Single cable is a dual serving cable that can perform in both wet and dry locations. It has a working temperature rating of -40 degrees Celsius as the cold bend up to 105 degrees Celsius. This cable is used in commercial and industrial applications of 15kV-35kV power voltage.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003econductor size\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003einsulation thickness (mils)\u003c\/td\u003e\n\u003ctd\u003econductor diameter (mm)\u003c\/td\u003e\n\u003ctd\u003einsulation diameter (mm)\u003c\/td\u003e\n\u003ctd\u003einsulation shield \u003cbr\u003e diameter (mm)\u003c\/td\u003e\n\u003ctd\u003eoverall \u003cbr\u003e jacket diameter (mm)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003ecable weight (lkg\/km)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eminimum bending \u003cbr\u003e radius (mm)\u003c\/td\u003e\n\u003ctd\u003eampacity in air and \u003cbr\u003e cable \u003cbr\u003e tray\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eimpedance in airand cable tray (μω\/m)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eprysmian \u003cbr\u003e cable part  number\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003e(a)\u003c\/td\u003e\n\u003ctd\u003e(b)\u003c\/td\u003e\n\u003ctd\u003e(c)\u003c\/td\u003e\n\u003ctd\u003e(d)\u003c\/td\u003e\n\u003ctd\u003e‡105°c\u003c\/td\u003e\n\u003ctd\u003epos\/neg seq\u003c\/td\u003e\n\u003ctd\u003ezero seq\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"12\"\u003e15kv 133% copper single conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1-0-awg-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e1\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e8.66\u003c\/td\u003e\n\u003ctd\u003e20.75\u003c\/td\u003e\n\u003ctd\u003e22.17\u003c\/td\u003e\n\u003ctd\u003e32.21\u003c\/td\u003e\n\u003ctd\u003e1403\u003c\/td\u003e\n\u003ctd\u003e387\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003e450 + j242\u003c\/td\u003e\n\u003ctd\u003e2497 + j93\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1-0-awg-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eQXM221A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-2-0-awg-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e2\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e9.55\u003c\/td\u003e\n\u003ctd\u003e21.69\u003c\/td\u003e\n\u003ctd\u003e23.16\u003c\/td\u003e\n\u003ctd\u003e33.20\u003c\/td\u003e\n\u003ctd\u003e1579\u003c\/td\u003e\n\u003ctd\u003e399\u003c\/td\u003e\n\u003ctd\u003e335\u003c\/td\u003e\n\u003ctd\u003e360 + j236\u003c\/td\u003e\n\u003ctd\u003e2313 + j88\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-2-0-awg-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eQXM222A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-4-0-awg-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e4\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e12.17\u003c\/td\u003e\n\u003ctd\u003e24.31\u003c\/td\u003e\n\u003ctd\u003e25.78\u003c\/td\u003e\n\u003ctd\u003e35.81\u003c\/td\u003e\n\u003ctd\u003e2040\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003ctd\u003e232 + j224\u003c\/td\u003e\n\u003ctd\u003e2003 + j78\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-4-0-awg-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eQXM223A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-250-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e250 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e13.26\u003c\/td\u003e\n\u003ctd\u003e25.60\u003c\/td\u003e\n\u003ctd\u003e27.03\u003c\/td\u003e\n\u003ctd\u003e37.31\u003c\/td\u003e\n\u003ctd\u003e2301\u003c\/td\u003e\n\u003ctd\u003e448\u003c\/td\u003e\n\u003ctd\u003e495\u003c\/td\u003e\n\u003ctd\u003e199 + j219\u003c\/td\u003e\n\u003ctd\u003e1887 + j74\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-250-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eQXZ632A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-350-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e350 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e15.80\u003c\/td\u003e\n\u003ctd\u003e28.65\u003c\/td\u003e\n\u003ctd\u003e30.07\u003c\/td\u003e\n\u003ctd\u003e39.85\u003c\/td\u003e\n\u003ctd\u003e2862\u003c\/td\u003e\n\u003ctd\u003e479\u003c\/td\u003e\n\u003ctd\u003e610\u003c\/td\u003e\n\u003ctd\u003e147 + j211\u003c\/td\u003e\n\u003ctd\u003e1672 + j69\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-350-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eQXJ244A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-500-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e500 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e18.85\u003c\/td\u003e\n\u003ctd\u003e31.19\u003c\/td\u003e\n\u003ctd\u003e32.61\u003c\/td\u003e\n\u003ctd\u003e43.31\u003c\/td\u003e\n\u003ctd\u003e3704\u003c\/td\u003e\n\u003ctd\u003e520\u003c\/td\u003e\n\u003ctd\u003e765\u003c\/td\u003e\n\u003ctd\u003e109 + j204\u003c\/td\u003e\n\u003ctd\u003e1521 + j62\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-500-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eQXZ311A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-750-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e750 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e23.29\u003c\/td\u003e\n\u003ctd\u003e35.84\u003c\/td\u003e\n\u003ctd\u003e37.26\u003c\/td\u003e\n\u003ctd\u003e49.48\u003c\/td\u003e\n\u003ctd\u003e5258\u003c\/td\u003e\n\u003ctd\u003e594\u003c\/td\u003e\n\u003ctd\u003e990\u003c\/td\u003e\n\u003ctd\u003e81 + j197\u003c\/td\u003e\n\u003ctd\u003e1322 + j56\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-750-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eQXJ524A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1000-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industri\"\u003e1000 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e27.20\u003c\/td\u003e\n\u003ctd\u003e39.75\u003c\/td\u003e\n\u003ctd\u003e41.17\u003c\/td\u003e\n\u003ctd\u003e53.39\u003c\/td\u003e\n\u003ctd\u003e6551\u003c\/td\u003e\n\u003ctd\u003e641\u003c\/td\u003e\n\u003ctd\u003e1185\u003c\/td\u003e\n\u003ctd\u003e67 + j191\u003c\/td\u003e\n\u003ctd\u003e1193 + j51\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1000-mcm-cu-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industri\"\u003eQXZ047A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"12\"\u003e15kv 133% aluminum single conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1-0-awg-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e1\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e8.66\u003c\/td\u003e\n\u003ctd\u003e20.75\u003c\/td\u003e\n\u003ctd\u003e22.17\u003c\/td\u003e\n\u003ctd\u003e32.21\u003c\/td\u003e\n\u003ctd\u003e1073\u003c\/td\u003e\n\u003ctd\u003e387\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003ctd\u003e737 + j242\u003c\/td\u003e\n\u003ctd\u003e2783 + j93\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1-0-awg-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-2-0-awg-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e2\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e9.55\u003c\/td\u003e\n\u003ctd\u003e21.69\u003c\/td\u003e\n\u003ctd\u003e23.16\u003c\/td\u003e\n\u003ctd\u003e33.20\u003c\/td\u003e\n\u003ctd\u003e1161\u003c\/td\u003e\n\u003ctd\u003e399\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003ctd\u003e586 + j236\u003c\/td\u003e\n\u003ctd\u003e2538 + j88\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-2-0-awg-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-4-0-awg-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e4\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e12.17\u003c\/td\u003e\n\u003ctd\u003e24.31\u003c\/td\u003e\n\u003ctd\u003e25.78\u003c\/td\u003e\n\u003ctd\u003e35.81\u003c\/td\u003e\n\u003ctd\u003e1381\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003ctd\u003e374 + j224\u003c\/td\u003e\n\u003ctd\u003e2143 + j78\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-4-0-awg-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-250-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e250 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e13.26\u003c\/td\u003e\n\u003ctd\u003e25.60\u003c\/td\u003e\n\u003ctd\u003e27.03\u003c\/td\u003e\n\u003ctd\u003e37.31\u003c\/td\u003e\n\u003ctd\u003e1524\u003c\/td\u003e\n\u003ctd\u003e448\u003c\/td\u003e\n\u003ctd\u003e385\u003c\/td\u003e\n\u003ctd\u003e319 + j219\u003c\/td\u003e\n\u003ctd\u003e2006 + j74\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-250-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-350-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e350 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e15.80\u003c\/td\u003e\n\u003ctd\u003e28.65\u003c\/td\u003e\n\u003ctd\u003e30.07\u003c\/td\u003e\n\u003ctd\u003e39.85\u003c\/td\u003e\n\u003ctd\u003e1767\u003c\/td\u003e\n\u003ctd\u003e479\u003c\/td\u003e\n\u003ctd\u003e480\u003c\/td\u003e\n\u003ctd\u003e233 + j211\u003c\/td\u003e\n\u003ctd\u003e1756 + j69\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-350-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-500-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e500 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e18.85\u003c\/td\u003e\n\u003ctd\u003e31.19\u003c\/td\u003e\n\u003ctd\u003e32.61\u003c\/td\u003e\n\u003ctd\u003e43.31\u003c\/td\u003e\n\u003ctd\u003e2143\u003c\/td\u003e\n\u003ctd\u003e520\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e169 + j204\u003c\/td\u003e\n\u003ctd\u003e1579 + j62\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-500-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-750-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003e750 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e23.29\u003c\/td\u003e\n\u003ctd\u003e35.84\u003c\/td\u003e\n\u003ctd\u003e37.26\u003c\/td\u003e\n\u003ctd\u003e49.48\u003c\/td\u003e\n\u003ctd\u003e2868\u003c\/td\u003e\n\u003ctd\u003e594\u003c\/td\u003e\n\u003ctd\u003e780\u003c\/td\u003e\n\u003ctd\u003e120 + j197\u003c\/td\u003e\n\u003ctd\u003e1359 + j56\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-750-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1000-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industri\"\u003e1000 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e27.20\u003c\/td\u003e\n\u003ctd\u003e39.75\u003c\/td\u003e\n\u003ctd\u003e41.17\u003c\/td\u003e\n\u003ctd\u003e53.39\u003c\/td\u003e\n\u003ctd\u003e3418\u003c\/td\u003e\n\u003ctd\u003e641\u003c\/td\u003e\n\u003ctd\u003e940\u003c\/td\u003e\n\u003ctd\u003e96 + j191\u003c\/td\u003e\n\u003ctd\u003e1220 + j51\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1000-mcm-al-single-conductor-airguard-csa-15kv-133-medium-voltage-commercial-industri\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"12\"\u003e25kv 133% copper single conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1-0-awg-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e1\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e8.66\u003c\/td\u003e\n\u003ctd\u003e25.98\u003c\/td\u003e\n\u003ctd\u003e27.41\u003c\/td\u003e\n\u003ctd\u003e37.44\u003c\/td\u003e\n\u003ctd\u003e1746\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003e452 + j253\u003c\/td\u003e\n\u003ctd\u003e2085 + j109\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1-0-awg-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eQXM241A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-2-0-awg-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e2\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e9.55\u003c\/td\u003e\n\u003ctd\u003e26.92\u003c\/td\u003e\n\u003ctd\u003e28.40\u003c\/td\u003e\n\u003ctd\u003e37.44\u003c\/td\u003e\n\u003ctd\u003e1924\u003c\/td\u003e\n\u003ctd\u003e462\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003ctd\u003e362 + j247\u003c\/td\u003e\n\u003ctd\u003e1935 + j104\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-2-0-awg-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eQXM242A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-4-0-awg-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e4\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e12.17\u003c\/td\u003e\n\u003ctd\u003e29.54\u003c\/td\u003e\n\u003ctd\u003e31.01\u003c\/td\u003e\n\u003ctd\u003e41.05\u003c\/td\u003e\n\u003ctd\u003e2411\u003c\/td\u003e\n\u003ctd\u003e493\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003ctd\u003e234 + j234\u003c\/td\u003e\n\u003ctd\u003e1687 + j92\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-4-0-awg-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eQXM243A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-250-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e250 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e13.26\u003c\/td\u003e\n\u003ctd\u003e30.84\u003c\/td\u003e\n\u003ctd\u003e32.31\u003c\/td\u003e\n\u003ctd\u003e43.00\u003c\/td\u003e\n\u003ctd\u003e2713\u003c\/td\u003e\n\u003ctd\u003e516\u003c\/td\u003e\n\u003ctd\u003e490\u003c\/td\u003e\n\u003ctd\u003e201 + j229\u003c\/td\u003e\n\u003ctd\u003e1596 + j88\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-250-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eQXM244A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-350-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e350 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e15.80\u003c\/td\u003e\n\u003ctd\u003e33.38\u003c\/td\u003e\n\u003ctd\u003e34.85\u003c\/td\u003e\n\u003ctd\u003e47.07\u003c\/td\u003e\n\u003ctd\u003e3456\u003c\/td\u003e\n\u003ctd\u003e565\u003c\/td\u003e\n\u003ctd\u003e605\u003c\/td\u003e\n\u003ctd\u003e150 + j223\u003c\/td\u003e\n\u003ctd\u003e1451 + j80\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-350-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eQXM245A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-500-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e500 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e18.85\u003c\/td\u003e\n\u003ctd\u003e36.42\u003c\/td\u003e\n\u003ctd\u003e37.85\u003c\/td\u003e\n\u003ctd\u003e50.06\u003c\/td\u003e\n\u003ctd\u003e4308\u003c\/td\u003e\n\u003ctd\u003e601\u003c\/td\u003e\n\u003ctd\u003e755\u003c\/td\u003e\n\u003ctd\u003e112 + j214\u003c\/td\u003e\n\u003ctd\u003e1314 + j73\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-500-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eQXM246A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-750-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e750 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e23.29\u003c\/td\u003e\n\u003ctd\u003e41.07\u003c\/td\u003e\n\u003ctd\u003e42.49\u003c\/td\u003e\n\u003ctd\u003e54.71\u003c\/td\u003e\n\u003ctd\u003e5759\u003c\/td\u003e\n\u003ctd\u003e657\u003c\/td\u003e\n\u003ctd\u003e970\u003c\/td\u003e\n\u003ctd\u003e83 + j204\u003c\/td\u003e\n\u003ctd\u003e1159 + j65\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-750-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eQXM247A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1000-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industri\"\u003e1000 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e27.20\u003c\/td\u003e\n\u003ctd\u003e44.98\u003c\/td\u003e\n\u003ctd\u003e46.41\u003c\/td\u003e\n\u003ctd\u003e58.62\u003c\/td\u003e\n\u003ctd\u003e7088\u003c\/td\u003e\n\u003ctd\u003e704\u003c\/td\u003e\n\u003ctd\u003e1160\u003c\/td\u003e\n\u003ctd\u003e67 + j190\u003c\/td\u003e\n\u003ctd\u003e1057 + j60\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1000-mcm-cu-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industri\"\u003eQXM248A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"12\"\u003e25kv 133% aluminum single conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1-0-awg-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e1\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e8.66\u003c\/td\u003e\n\u003ctd\u003e25.98\u003c\/td\u003e\n\u003ctd\u003e27.41\u003c\/td\u003e\n\u003ctd\u003e37.44\u003c\/td\u003e\n\u003ctd\u003e1415\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003ctd\u003e739 + j253\u003c\/td\u003e\n\u003ctd\u003e2372 + j109\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1-0-awg-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-2-0-awg-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e2\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e9.55\u003c\/td\u003e\n\u003ctd\u003e26.92\u003c\/td\u003e\n\u003ctd\u003e28.40\u003c\/td\u003e\n\u003ctd\u003e38.43\u003c\/td\u003e\n\u003ctd\u003e1506\u003c\/td\u003e\n\u003ctd\u003e462\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003ctd\u003e588 + j247\u003c\/td\u003e\n\u003ctd\u003e2160 + j104\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-2-0-awg-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-4-0-awg-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e4\/0 awg al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e12.17\u003c\/td\u003e\n\u003ctd\u003e29.54\u003c\/td\u003e\n\u003ctd\u003e31.01\u003c\/td\u003e\n\u003ctd\u003e41.05\u003c\/td\u003e\n\u003ctd\u003e1751\u003c\/td\u003e\n\u003ctd\u003e493\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003ctd\u003e376 + j234\u003c\/td\u003e\n\u003ctd\u003e1828 + j92\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-4-0-awg-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-250-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e250 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e13.26\u003c\/td\u003e\n\u003ctd\u003e30.84\u003c\/td\u003e\n\u003ctd\u003e32.31\u003c\/td\u003e\n\u003ctd\u003e43.00\u003c\/td\u003e\n\u003ctd\u003e1936\u003c\/td\u003e\n\u003ctd\u003e516\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003ctd\u003e321 + j229\u003c\/td\u003e\n\u003ctd\u003e1714 + j88\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-250-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-350-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e350 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e15.80\u003c\/td\u003e\n\u003ctd\u003e33.38\u003c\/td\u003e\n\u003ctd\u003e34.85\u003c\/td\u003e\n\u003ctd\u003e47.07\u003c\/td\u003e\n\u003ctd\u003e2360\u003c\/td\u003e\n\u003ctd\u003e565\u003c\/td\u003e\n\u003ctd\u003e475\u003c\/td\u003e\n\u003ctd\u003e235 + j233\u003c\/td\u003e\n\u003ctd\u003e1535 + j80\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-350-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-500-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e500 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e18.85\u003c\/td\u003e\n\u003ctd\u003e36.42\u003c\/td\u003e\n\u003ctd\u003e37.85\u003c\/td\u003e\n\u003ctd\u003e50.06\u003c\/td\u003e\n\u003ctd\u003e2747\u003c\/td\u003e\n\u003ctd\u003e601\u003c\/td\u003e\n\u003ctd\u003e590\u003c\/td\u003e\n\u003ctd\u003e171 + j214\u003c\/td\u003e\n\u003ctd\u003e1372 + j73\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-500-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-750-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003e750 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e23.29\u003c\/td\u003e\n\u003ctd\u003e41.07\u003c\/td\u003e\n\u003ctd\u003e42.49\u003c\/td\u003e\n\u003ctd\u003e54.71\u003c\/td\u003e\n\u003ctd\u003e3369\u003c\/td\u003e\n\u003ctd\u003e657\u003c\/td\u003e\n\u003ctd\u003e765\u003c\/td\u003e\n\u003ctd\u003e122 + j204\u003c\/td\u003e\n\u003ctd\u003e1196 + j65\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-750-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industria\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1000-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industri\"\u003e1000 mcm al\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003ctd\u003e27.20\u003c\/td\u003e\n\u003ctd\u003e44.98\u003c\/td\u003e\n\u003ctd\u003e46.41\u003c\/td\u003e\n\u003ctd\u003e58.62\u003c\/td\u003e\n\u003ctd\u003e3955\u003c\/td\u003e\n\u003ctd\u003e704\u003c\/td\u003e\n\u003ctd\u003e920\u003c\/td\u003e\n\u003ctd\u003e98 + j197\u003c\/td\u003e\n\u003ctd\u003e1084 + j60\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1000-mcm-al-single-conductor-airguard-csa-25kv-133-medium-voltage-commercial-industri\"\u003eCODE DNE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"12\"\u003e35kv 133% copper single conductor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1-0-awg-cu-single-conductor-airguard-csa-35kv133-medium-voltage-commercial-industrial\"\u003e1\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e8.66\u003c\/td\u003e\n\u003ctd\u003e30.86\u003c\/td\u003e\n\u003ctd\u003e32.28\u003c\/td\u003e\n\u003ctd\u003e43.84\u003c\/td\u003e\n\u003ctd\u003e2243\u003c\/td\u003e\n\u003ctd\u003e527\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003ctd\u003e454 + j264\u003c\/td\u003e\n\u003ctd\u003e1820 + j121\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1-0-awg-cu-single-conductor-airguard-csa-35kv133-medium-voltage-commercial-industrial\"\u003eQXM300A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-2-0-awg-cu-single-conductor-airguard-csa-35kv133-medium-voltage-commercial-industrial\"\u003e2\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e9.55\u003c\/td\u003e\n\u003ctd\u003e31.75\u003c\/td\u003e\n\u003ctd\u003e33.17\u003c\/td\u003e\n\u003ctd\u003e45.39\u003c\/td\u003e\n\u003ctd\u003e2475\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003ctd\u003e364 + j259\u003c\/td\u003e\n\u003ctd\u003e1697 + j115\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-2-0-awg-cu-single-conductor-airguard-csa-35kv133-medium-voltage-commercial-industrial\"\u003eQXM301A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-3-0-awg-cu-single-conductor-airguard-csa-35kv133-medium-voltage-commercial-industrial\"\u003e3\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e10.74\u003c\/td\u003e\n\u003ctd\u003e32.94\u003c\/td\u003e\n\u003ctd\u003e34.74\u003c\/td\u003e\n\u003ctd\u003e46.58\u003c\/td\u003e\n\u003ctd\u003e2710\u003c\/td\u003e\n\u003ctd\u003e559\u003c\/td\u003e\n\u003ctd\u003e380\u003c\/td\u003e\n\u003ctd\u003e293 + j252\u003c\/td\u003e\n\u003ctd\u003e1538 + j109\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-3-0-awg-cu-single-conductor-airguard-csa-35kv133-medium-voltage-commercial-industrial\"\u003eQXM302A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-4-0-awg-cu-single-conductor-airguard-csa-35kv133-medium-voltage-commercial-industrial\"\u003e4\/0 awg cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e12.17\u003c\/td\u003e\n\u003ctd\u003e34.37\u003c\/td\u003e\n\u003ctd\u003e35.79\u003c\/td\u003e\n\u003ctd\u003e48.01\u003c\/td\u003e\n\u003ctd\u003e3002\u003c\/td\u003e\n\u003ctd\u003e577\u003c\/td\u003e\n\u003ctd\u003e445\u003c\/td\u003e\n\u003ctd\u003e237 + j244\u003c\/td\u003e\n\u003ctd\u003e1479 + j103\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-4-0-awg-cu-single-conductor-airguard-csa-35kv133-medium-voltage-commercial-industrial\"\u003eQXM303A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-250-kcm-cu-single-conductor-airguard-csa-35kv133-medium-voltage-commercial-industrial\"\u003e250 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e13.26\u003c\/td\u003e\n\u003ctd\u003e35.66\u003c\/td\u003e\n\u003ctd\u003e37.08\u003c\/td\u003e\n\u003ctd\u003e49.30\u003c\/td\u003e\n\u003ctd\u003e3267\u003c\/td\u003e\n\u003ctd\u003e592\u003c\/td\u003e\n\u003ctd\u003e490\u003c\/td\u003e\n\u003ctd\u003e203 + j239\u003c\/td\u003e\n\u003ctd\u003e1404 + j98\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-250-kcm-cu-single-conductor-airguard-csa-35kv133-medium-voltage-commercial-industrial\"\u003eQXM304A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-350-kcm-cu-single-conductor-airguard-csa-35kv133-medium-voltage-commercial-industrial\"\u003e350 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e15.80\u003c\/td\u003e\n\u003ctd\u003e38.20\u003c\/td\u003e\n\u003ctd\u003e39.62\u003c\/td\u003e\n\u003ctd\u003e51.84\u003c\/td\u003e\n\u003ctd\u003e3892\u003c\/td\u003e\n\u003ctd\u003e623\u003c\/td\u003e\n\u003ctd\u003e605\u003c\/td\u003e\n\u003ctd\u003e151 + j229\u003c\/td\u003e\n\u003ctd\u003e1280 + j90\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-350-kcm-cu-single-conductor-airguard-csa-35kv133-medium-voltage-commercial-industrial\"\u003eQXV711A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-500-kcm-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industria\"\u003e500 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e18.85\u003c\/td\u003e\n\u003ctd\u003e41.25\u003c\/td\u003e\n\u003ctd\u003e42.67\u003c\/td\u003e\n\u003ctd\u003e54.89\u003c\/td\u003e\n\u003ctd\u003e4767\u003c\/td\u003e\n\u003ctd\u003e659\u003c\/td\u003e\n\u003ctd\u003e755\u003c\/td\u003e\n\u003ctd\u003e113 + j220\u003c\/td\u003e\n\u003ctd\u003e1166 + j82\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-500-kcm-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industria\"\u003eQXV231A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-750-mcm-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industria\"\u003e750 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e23.29\u003c\/td\u003e\n\u003ctd\u003e45.90\u003c\/td\u003e\n\u003ctd\u003e47.32\u003c\/td\u003e\n\u003ctd\u003e59.54\u003c\/td\u003e\n\u003ctd\u003e6258\u003c\/td\u003e\n\u003ctd\u003e715\u003c\/td\u003e\n\u003ctd\u003e970\u003c\/td\u003e\n\u003ctd\u003e84 + j209\u003c\/td\u003e\n\u003ctd\u003e1037 + j73\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-750-mcm-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industria\"\u003eQXV616A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1000-mcm-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industri\"\u003e1000 mcm cu\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003ctd\u003e27.20\u003c\/td\u003e\n\u003ctd\u003e49.81\u003c\/td\u003e\n\u003ctd\u003e51.23\u003c\/td\u003e\n\u003ctd\u003e63.45\u003c\/td\u003e\n\u003ctd\u003e7621\u003c\/td\u003e\n\u003ctd\u003e762\u003c\/td\u003e\n\u003ctd\u003e1160\u003c\/td\u003e\n\u003ctd\u003e71 + j202\u003c\/td\u003e\n\u003ctd\u003e953 + j67\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/medium-voltage-power-cable\/5-35kv-commercial-and-industrial-cables\/prysmian-cable-1000-mcm-cu-single-conductor-airguard-csa-35kv-133-medium-voltage-commercial-industri\"\u003eQXM305A\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Prysmian Cable","offers":[{"title":"Default Title","offer_id":7322945159231,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/AIRGUARD_CSA_Cable-lg.jpg?v=1571729394"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/AIRGUARD_CSA_Cable-lg.jpg?v=1523539353","url":"https:\/\/www.nassauelectrical.com\/collections\/prysmian-cable-15kv-35kv-single-conductor-airguard-csa-medium-voltage-commercial-industrial-cables.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}