{"title":"Prysmian and Draka Cable RFCU 0.6\/1kV Power and Control or Lighting Cable","description":"","products":[{"product_id":"prysmian-and-draka-cable-12-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840264","title":"Prysmian and Draka Cable 12 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840264","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 12 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840264\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 12 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840264. Click for a free quote. 12 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840264, Draka Cable 840264, 12 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840264, 840264, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e20.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e710\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e167\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewba02\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840264\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185891721279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg.jpg?v=1571728940"},{"product_id":"prysmian-and-draka-cable-12-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840070","title":"Prysmian and Draka Cable 12 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840070","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 12 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840070\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 12 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840070. Click for a free quote. 12 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840070, Draka Cable 840070, 12 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840070, 840070, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e2.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e22.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e900\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e275\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewba03\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840070\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185891852351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_4abef4fd-c3a3-47ee-9130-cd55a4a0e361.jpg?v=1571728940"},{"product_id":"prysmian-and-draka-cable-19-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840160","title":"Prysmian and Draka Cable 19 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840160","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 19 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840160\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 19 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840160. Click for a free quote. 19 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840160, Draka Cable 840160, 19 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840160, 840160, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e960\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e264\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewbb02\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840160\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185936220223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_d613f005-39e1-477a-b319-bee33d021ad4.jpg?v=1571728969"},{"product_id":"prysmian-and-draka-cable-19-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840071","title":"Prysmian and Draka Cable 19 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840071","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 19 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840071\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 19 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840071. Click for a free quote. 19 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840071, Draka Cable 840071, 19 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840071, 840071, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e2.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e27\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1240\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e435\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewbb03\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840071\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185936318527,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_568e50f9-9f32-4be1-8001-6623a8920869.jpg?v=1571728969"},{"product_id":"prysmian-and-draka-cable-2-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840049","title":"Prysmian and Draka Cable 2 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840049","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 2 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840049\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 2 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840049. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840049, Draka Cable 840049, 2 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840049, 840049, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e8.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e12.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e280\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e28\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb202\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840049\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185939333183,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_ec4c7105-f251-4f27-b25a-f0071ba835e9.jpg?v=1571728970"},{"product_id":"prysmian-and-draka-cable-2-cores-16-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840258","title":"Prysmian and Draka Cable 2 Cores 16 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840258","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 2 Cores 16 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840258\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 2 Cores 16 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840258. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840258, Draka Cable 840258, 2 Cores 16 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840258, 840258, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e5.15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e17.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e22\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e940\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e289\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb216\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840258\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185940709439,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_a58a0d9f-a69a-4869-aac8-0e86c26204cb.jpg?v=1571728971"},{"product_id":"prysmian-and-draka-cable-2-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840050","title":"Prysmian and Draka Cable 2 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840050","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 2 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840050\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 2 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840050. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840050, Draka Cable 840050, 2 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840050, 840050, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e2.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e9.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e13.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e320\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e46\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb203\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840050\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185941725247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_0b042ba4-2cb3-4277-af72-a4c071c838e4.jpg?v=1571728971"},{"product_id":"prysmian-and-draka-cable-2-cores-35-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840269","title":"Prysmian and Draka Cable 2 Cores 35 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840269","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 2 Cores 35 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840269\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 2 Cores 35 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840269. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840269, Draka Cable 840269, 2 Cores 35 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840269, 840269, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e7.65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e23.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e28.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1650\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e618\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb235\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840269\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185943461951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_8685b823-9649-4a77-bbac-bc5f7dbddf24.jpg?v=1571728972"},{"product_id":"prysmian-and-draka-cable-2-cores-4-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840051","title":"Prysmian and Draka Cable 2 Cores 4 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840051","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 2 Cores 4 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840051\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 2 Cores 4 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840051. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840051, Draka Cable 840051, 2 Cores 4 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840051, 840051, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.55\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e11.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e15.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e440\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e74\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb204\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840051\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185943527487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_8a7f5bb5-c018-4a02-a3b0-8ac457e7ceb2.jpg?v=1571728972"},{"product_id":"prysmian-and-draka-cable-2-cores-6-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840245","title":"Prysmian and Draka Cable 2 Cores 6 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840245","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 2 Cores 6 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840245\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 2 Cores 6 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840245. Click for a free quote. 2 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840245, Draka Cable 840245, 2 Cores 6 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840245, 840245, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e3.15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e13\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e540\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e109\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb206\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840245\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185943986239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_c718441c-d702-4ce9-aab1-a3af42cce46a.jpg?v=1571728972"},{"product_id":"prysmian-and-draka-cable-27-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840262","title":"Prysmian and Draka Cable 27 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840262","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 27 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840262\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 27 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840262. Click for a free quote. 27 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840262, Draka Cable 840262, 27 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840262, 840262, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e27\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e2.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e25.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e31.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1820\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e618\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewbc03\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840262\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7186003787839,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_c7db947d-8142-4522-8224-e3b0e8ef67ea.jpg?v=1571729000"},{"product_id":"prysmian-and-draka-cable-3-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840052","title":"Prysmian and Draka Cable 3 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840052","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840052\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840052. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840052, Draka Cable 840052, 3 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840052, 840052, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e13\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e310\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e42\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb302\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840052\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7187572097087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_06a7a928-54a6-4247-82df-d6e6b5646554.jpg?v=1571729220"},{"product_id":"prysmian-and-draka-cable-3-cores-10-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840154","title":"Prysmian and Draka Cable 3 Cores 10 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840154","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 Cores 10 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840154\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 Cores 10 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840154. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840154, Draka Cable 840154, 3 Cores 10 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840154, 840154, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e4.05\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e20.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e830\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e271\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb310\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840154\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7187572293695,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_8bc6bac0-7ec7-4d48-9cd0-d258f5d5fc0a.jpg?v=1571729220"},{"product_id":"prysmian-and-draka-cable-3-cores-16-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840056","title":"Prysmian and Draka Cable 3 Cores 16 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840056","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 Cores 16 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840056\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 Cores 16 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840056. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840056, Draka Cable 840056, 3 Cores 16 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840056, 840056, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e5.15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e18.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e23\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1120\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e434\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb316\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840056\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187574423615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_05b75629-f271-4366-8597-1ccd4b79c497.jpg?v=1571729220"},{"product_id":"prysmian-and-draka-cable-3-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840053","title":"Prysmian and Draka Cable 3 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840053","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840053\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840053. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840053, Draka Cable 840053, 3 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840053, 840053, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e2.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e360\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e69\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb303\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840053\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187574980671,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_169da828-37c4-4c80-90c0-4286dfea89d3.jpg?v=1571729221"},{"product_id":"prysmian-and-draka-cable-3-cores-25-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840158","title":"Prysmian and Draka Cable 3 Cores 25 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840158","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 Cores 25 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840158\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 Cores 25 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840158. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840158, Draka Cable 840158, 3 Cores 25 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840158, 840158, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e6.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e22.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e28\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1640\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e688\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb325\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840158\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187575308351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_e073f2a1-8a1b-479c-b298-f4319d2ee770.jpg?v=1571729221"},{"product_id":"prysmian-and-draka-cable-3-cores-35-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840057","title":"Prysmian and Draka Cable 3 Cores 35 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840057","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 Cores 35 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840057\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 Cores 35 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840057. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840057, Draka Cable 840057, 3 Cores 35 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840057, 840057, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e7.65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e25.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2150\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e927\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb335\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840057\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187576029247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_eebe92b5-9e37-48f1-aef2-83ca00884c3d.jpg?v=1571729221"},{"product_id":"prysmian-and-draka-cable-3-cores-4-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840054","title":"Prysmian and Draka Cable 3 Cores 4 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840054","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 Cores 4 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840054\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 Cores 4 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840054. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840054, Draka Cable 840054, 3 Cores 4 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840054, 840054, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.55\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e12.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e16.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e490\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e110\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb304\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840054\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187576094783,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_5f1edf64-db6e-4df3-bda4-1cee1449dc2b.jpg?v=1571729221"},{"product_id":"prysmian-and-draka-cable-3-cores-50-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840283","title":"Prysmian and Draka Cable 3 Cores 50 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840283","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 Cores 50 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840283\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 Cores 50 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840283. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840283, Draka Cable 840283, 3 Cores 50 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840283, 840283, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e29.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2830\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1287\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb350\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840283\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187576258623,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_e6bc271a-8b7f-4b0f-aa52-12a71b4ba38e.jpg?v=1571729221"},{"product_id":"prysmian-and-draka-cable-3-cores-6-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840055","title":"Prysmian and Draka Cable 3 Cores 6 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840055","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 Cores 6 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840055\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 Cores 6 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840055. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840055, Draka Cable 840055, 3 Cores 6 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840055, 840055, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e3.15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e13.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e610\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e164\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb306\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840055\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187576586303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_bd4926cf-3780-4d98-975f-6c262210b822.jpg?v=1571729221"},{"product_id":"prysmian-and-draka-cable-3-cores-70-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840058","title":"Prysmian and Draka Cable 3 Cores 70 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840058","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 Cores 70 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840058\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 Cores 70 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840058. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840058, Draka Cable 840058, 3 Cores 70 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840058, 840058, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e70\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e10.85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e34\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3770\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1863\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb370\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840058\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187577864255,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_4f9885d7-9b9d-4a54-ba3f-1248fd250549.jpg?v=1571729221"},{"product_id":"prysmian-and-draka-cable-3-cores-95-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840311","title":"Prysmian and Draka Cable 3 Cores 95 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840311","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 Cores 95 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840311\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 Cores 95 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840311. Click for a free quote. 3 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840311, Draka Cable 840311, 3 Cores 95 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840311, 840311, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e95\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e12.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e4860\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2513\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb395\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840311\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187577929791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_d70574d0-949e-40e3-b799-0a450d0a75f0.jpg?v=1571729222"},{"product_id":"prysmian-and-draka-cable-37-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840256","title":"Prysmian and Draka Cable 37 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840256","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 37 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840256\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 37 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840256. Click for a free quote. 37 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840256, Draka Cable 840256, 37 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840256, 840256, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e37\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e2.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e29\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2270\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e847\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewbd03\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840256\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187588775999,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_4363d75a-cda3-40e9-88e9-e2c08e2343ad.jpg?v=1571729245"},{"product_id":"prysmian-and-draka-cable-4-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840059","title":"Prysmian and Draka Cable 4 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840059","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840059\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840059. Click for a free quote. 4 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840059, Draka Cable 840059, 4 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840059, 840059, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e350\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e56\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb402\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840059\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187598114879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_21c7b86b-2c7e-43c3-9e5a-b47025ccbf7d.jpg?v=1571729247"},{"product_id":"prysmian-and-draka-cable-4-cores-10-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840159","title":"Prysmian and Draka Cable 4 Cores 10 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840159","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 Cores 10 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840159\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 Cores 10 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840159. Click for a free quote. 4 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840159, Draka Cable 840159, 4 Cores 10 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840159, 840159, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e4.05\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e17.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e22.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1000\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e361\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb410\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840159\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187598245951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_d53d2a53-f315-4abc-a378-b73b1c82b60a.jpg?v=1571729247"},{"product_id":"prysmian-and-draka-cable-4-cores-16-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840063","title":"Prysmian and Draka Cable 4 Cores 16 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840063","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 Cores 16 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840063\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 Cores 16 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840063. Click for a free quote. 4 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840063, Draka Cable 840063, 4 Cores 16 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840063, 840063, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e5.15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e20.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e25.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1390\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e578\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb416\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840063\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187598278719,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_7265ffeb-e828-477a-8c56-93e6cfc9556d.jpg?v=1571729247"},{"product_id":"prysmian-and-draka-cable-4-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840284","title":"Prysmian and Draka Cable 4 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840284","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840284\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840284. Click for a free quote. 4 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840284, Draka Cable 840284, 4 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840284, 840284, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e2.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e92\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb403\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840284\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187598409791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_b7b5a58a-2f69-40b2-8c62-2cdec4835852.jpg?v=1571729247"},{"product_id":"prysmian-and-draka-cable-4-cores-25-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840064","title":"Prysmian and Draka Cable 4 Cores 25 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840064","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 Cores 25 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840064\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 Cores 25 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840064. Click for a free quote. 4 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840064, Draka Cable 840064, 4 Cores 25 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840064, 840064, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e6.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2130\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e917\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb425\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840064\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187599425599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_5a652f90-a1dd-45a1-8cad-a4d0531f62b6.jpg?v=1571729247"},{"product_id":"prysmian-and-draka-cable-4-cores-35-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840065","title":"Prysmian and Draka Cable 4 Cores 35 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840065","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 Cores 35 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840065\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 Cores 35 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840065. Click for a free quote. 4 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840065, Draka Cable 840065, 4 Cores 35 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840065, 840065, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e7.65\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e28\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e34\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2620\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1236\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb435\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840065\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187599491135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_ebcb6a8a-ed08-443b-8e09-86b9bbcf5ebd.jpg?v=1571729247"},{"product_id":"prysmian-and-draka-cable-4-cores-4-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840061","title":"Prysmian and Draka Cable 4 Cores 4 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840061","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 Cores 4 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840061\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 Cores 4 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840061. Click for a free quote. 4 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840061, Draka Cable 840061, 4 Cores 4 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840061, 840061, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.55\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e13.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e590\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e147\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb404\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840061\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187599622207,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_98ce95cd-41c2-4d21-94d6-1830406b067b.jpg?v=1571729247"},{"product_id":"prysmian-and-draka-cable-4-cores-50-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840166","title":"Prysmian and Draka Cable 4 Cores 50 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840166","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 Cores 50 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840166\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 Cores 50 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840166. Click for a free quote. 4 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840166, Draka Cable 840166, 2 Cores 50 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840166, 840166, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e33\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e39.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3480\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1716\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb450\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840166\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187599654975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_76189cc5-463f-4f5d-8549-f484c2432a3a.jpg?v=1571729247"},{"product_id":"prysmian-and-draka-cable-4-cores-6-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840246","title":"Prysmian and Draka Cable 4 Cores 6 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840246","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 Cores 6 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840246\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 Cores 6 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840246. Click for a free quote. 4 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840246, Draka Cable 840246, 4 Cores 6 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840246, 840246, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e3.15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e19.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e740\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e218\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb406\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840246\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187599982655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_4f18cbc4-4646-4cc7-849e-f026ba5bd502.jpg?v=1571729247"},{"product_id":"prysmian-and-draka-cable-4-cores-70-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840088","title":"Prysmian and Draka Cable 4 Cores 70 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840088","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 Cores 70 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840088\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 Cores 70 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840088. Click for a free quote. 4 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840088, Draka Cable 840088, 4 Cores 70 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840088, 840088, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e70\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e10.85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e38\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e44\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e4670\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2484\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb470\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840088\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187600146495,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_243018d1-2526-4890-8f38-a6080c3170de.jpg?v=1571729247"},{"product_id":"prysmian-and-draka-cable-4-cores-95-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840242","title":"Prysmian and Draka Cable 4 Cores 95 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840242","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 Cores 95 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840242\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 Cores 95 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840242. Click for a free quote. 4 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840242, Draka Cable 840242, 4 Cores 95 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840242, 840242, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e95\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e12.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e43.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e2.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e50.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e6080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3351\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb495\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840242\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187600179263,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_25f6413f-838f-4d38-8208-8d6f7876533a.jpg?v=1571729247"},{"product_id":"prysmian-and-draka-cable-5-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840338","title":"Prysmian and Draka Cable 5 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840338","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 5 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840338\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 5 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840338. Click for a free quote. 5 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840338, Draka Cable 840338, 5 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840338, 840338, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e440\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003e-\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840338\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187617611839,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_5020bc15-366e-4145-9062-6699dbe8565f.jpg?v=1571729250"},{"product_id":"prysmian-and-draka-cable-7-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840263","title":"Prysmian and Draka Cable 7 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840263","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 7 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840263\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 7 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840263. Click for a free quote. 7 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840263, Draka Cable 840263, 7 Cores 1.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840263, 840263, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e17\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e470\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e98\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb702\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840263\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187643498559,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_e464b47d-2c5b-4c69-be29-b41162c69f1d.jpg?v=1571729254"},{"product_id":"prysmian-and-draka-cable-7-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cable-840068","title":"Prysmian and Draka Cable 7 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840068","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 7 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840068\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 7 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840068. Click for a free quote. 7 Cores.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable 840068, Draka Cable 840068, 7 Cores 2.5 Cross-section core RFCU 0.6\/1kV Power and Control or Lighting Cable 840068, 840068, RFCU Cable, RFCU Power Cable, RFCU Control Cable, RFCU Lighting Cable, Tinned stranded Copper Conductor Cable, EP-rubber Insulation Cable, Flame retardant Cable, Type P Cable, Type P Rig Cable, Marine Cable, Rig Cable, Halogen Free Cable, RFCU 0.6\/1kV Power and Control or Lighting Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e\n        • BS6883 \/ UKOOA - Design\u003cbr\u003e\n        • BS6360 class 2 - Conductor\u003cbr\u003e\n        • BS7655 section 1.2 - Insulation\u003cbr\u003e\n        • BS7655 section 2.6 - Sheath\u003cbr\u003e\n        • IEC 60332-1 - Flame Retardant\u003cbr\u003e\n        • IEC60332-3-22 - Flame retardant\u003cbr\u003e\n        • IEC60754-1.2 - Halogen Free\u003cbr\u003e\n        • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e\n        • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e\n        • BS 6883 : 1999\u003cbr\u003e\n        • BS 6883 : 1991\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e\n        • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003enumber of cores\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section core, mm2\u003c\/td\u003e\n                    \u003ctd\u003e2.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einsulation thickness, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. diameter inner sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e13.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ediameter braid wire, mm\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ethickness outer sheath, mm\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eapprox. overall diameter, mm\u003c\/td\u003e\n                    \u003ctd\u003e18.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight of cable approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e590\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecopper content approx. (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e161\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eukooa code\u003c\/td\u003e\n                    \u003ctd\u003ewb703\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable part number\u003c\/td\u003e\n                    \u003ctd\u003e840068\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187643564095,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_200.6_201kV_20Power_Control_20Cable-lg_b1d03ad3-1dfb-4348-b01e-660225d1d237.jpg?v=1571729254"},{"product_id":"prysmian-and-draka-cable-rfcu-0-6-1kv-power-and-control-or-lighting-cable","title":"Prysmian and Draka Cable RFCU 0.6\/1kV Power and Control or Lighting Cable","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor\u003c\/strong\u003e: Tinned Standed circular copper, BS 6360, class 2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation\u003c\/strong\u003e: EP-rubber, GP4 to BS 7655: section 1.2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLay up \/ Shielding\u003c\/strong\u003e: Cores laid up in concentric layers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner covering\u003c\/strong\u003e: Flame retardant and halogen-free thermoset compound\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTape over inner covering\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmour\/screen\u003c\/strong\u003e: Galvanized steel wire braid\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTape over armour\/screen\u003c\/strong\u003e: PET tape + rubberized Polyamide tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter sheath\u003c\/strong\u003e: Flame retardant, halogen-free, enhanced oil-resisting thermoset compound (LSF), SW4 to BS 7655 section 2.6\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMarking text\u003c\/strong\u003e: \"meter mark\" \"year\" \"DRAKA\" \"RFCU\" \"UKOOA code\" \"600\/1000V\" \"number of cores\" \"conductor size\" \"BS6883\" \"IEC60332-3-22\" (marking may differ on cable actually supplied)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter sheath colour\u003c\/strong\u003e: Black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCore identification\u003c\/strong\u003e: All cores are offwhite with black numbers No 1,2,3.....\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating temperature\u003c\/strong\u003e: 90°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Voltage\u003c\/strong\u003e: 0.6\/1kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards applied\u003c\/strong\u003e:\u003cbr\u003e • BS6883 \/ UKOOA - Design\u003cbr\u003e • BS6360 class 2 - Conductor\u003cbr\u003e • BS7655 section 1.2 - Insulation\u003cbr\u003e • BS7655 section 2.6 - Sheath\u003cbr\u003e • IEC 60332-1 - Flame Retardant\u003cbr\u003e • IEC60332-3-22 - Flame retardant\u003cbr\u003e • IEC60754-1.2 - Halogen Free\u003cbr\u003e • IEC 61034-1.2 - Low Smoke\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDescription\u003c\/strong\u003e:\u003cbr\u003e • RFCU 0.6\/1kV 2X 1.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 2X 2.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 2X 4mm2\u003cbr\u003e • RFCU 0.6\/1kV 2X 6mm2\u003cbr\u003e • RFCU 0.6\/1kV 2X 16mm2\u003cbr\u003e • RFCU 0.6\/1kV 2X 35mm2\u003cbr\u003e • RFCU 0.6\/1kV 3X 1.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 3X 2.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 3X 4mm2\u003cbr\u003e • RFCU 0.6\/1kV 3X 6mm2\u003cbr\u003e • RFCU 0.6\/1kV 3X 10mm2\u003cbr\u003e • RFCU 0.6\/1kV 3X 16mm2\u003cbr\u003e • RFCU 0.6\/1kV 3X 25mm2\u003cbr\u003e • RFCU 0.6\/1kV 3X 35mm2\u003cbr\u003e • RFCU 0.6\/1kV 3X 50mm2\u003cbr\u003e • RFCU 0.6\/1kV 3X 70mm2\u003cbr\u003e • RFCU 0.6\/1kV 3X 95mm2\u003cbr\u003e • RFCU 0.6\/1kV 4X 1.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 4X 2.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 4X 4mm2\u003cbr\u003e • RFCU 0.6\/1kV 4X 6mm2\u003cbr\u003e • RFCU 0.6\/1kV 4X 10mm2\u003cbr\u003e • RFCU 0.6\/1kV 4X 16mm2\u003cbr\u003e • RFCU 0.6\/1kV 4X 25mm2\u003cbr\u003e • RFCU 0.6\/1kV 4X 35mm2\u003cbr\u003e • RFCU 0.6\/1kV 4X 50mm2\u003cbr\u003e • RFCU 0.6\/1kV 4X 70mm2\u003cbr\u003e • RFCU 0.6\/1kV 4X 95mm2\u003cbr\u003e • RFCU 0.6\/1kV 5X 1.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 7X 1.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 7X 2.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 12X 1.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 12X 2.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 19X 1.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 19X 2.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 27X 2.5mm2\u003cbr\u003e • RFCU 0.6\/1kV 37X 2.5mm2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath Colour\u003c\/strong\u003e: BLACK\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDesign standard\u003c\/strong\u003e:\u003cbr\u003e • BS 6883 : 1999\u003cbr\u003e • BS 6883 : 1991\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e • Armoured cable for fixed installation for power, control or lighting in both EX and safe areas where cable protection is required. General purpose use.\u003cbr\u003e • Enhanced MUD resistant version also available for use in areas exposed to mud and drilling \/ cleaning fluids, meeting the mud resistance requirement in NEK 606.\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cstrong\u003eRange and dimensions\u003c\/strong\u003e \u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.\u003cbr\u003e of cores\u003c\/td\u003e\n\u003ctd\u003ecross- section\u003cbr\u003e core, mm2\u003c\/td\u003e\n\u003ctd\u003eukooa code\u003c\/td\u003e\n\u003ctd\u003eprysmian and\u003cbr\u003e draka cable\u003cbr\u003e part number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003ewb202\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e840049\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003ewb203\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e840050\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-4-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003ewb204\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-4-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e840051\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-4-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-6-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003ewb206\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-6-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e840245\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-6-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-16-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003ewb216\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-16-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840258\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-16-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-35-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003ewb235\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-35-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840269\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-2-cores-35-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003ewb302\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e840052\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003ewb303\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e840053\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-4-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003ewb304\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-4-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e840054\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-4-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-6-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003ewb306\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-6-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e840055\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-6-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-10-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003ewb310\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-10-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840154\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-10-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-16-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003ewb316\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-16-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840056\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-16-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-25-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003ewb325\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-25-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840158\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-25-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-35-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003ewb335\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-35-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840057\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-35-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-50-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003ewb350\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-50-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840283\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-50-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-70-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003ewb370\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-70-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840058\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-70-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-95-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003ewb395\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-95-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840311\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-3-cores-95-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003ewb402\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e840059\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003ewb403\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e840284\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-4-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003ewb404\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-4-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e840061\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-4-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-6-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003ewb406\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-6-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e840246\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-6-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-10-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003ewb410\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-10-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840159\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-10-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-16-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003ewb416\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-16-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840063\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-16-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-25-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003ewb425\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-25-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840064\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-25-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-35-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003ewb435\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-35-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840065\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-35-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-50-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003ewb450\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-50-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840166\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-50-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-70-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003ewb470\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-70-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840088\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-70-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-95-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003ewb495\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-95-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e840242\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-4-cores-95-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-5-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e-\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-5-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e840338\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-5-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-7-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e7\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003ewb702\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-7-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e840263\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-7-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-7-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e7\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003ewb703\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-7-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e840068\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-7-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-12-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003ewba02\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-12-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e840264\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-12-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-12-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003ewba03\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-12-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e840070\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-12-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-19-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003ewbb02\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-19-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e840160\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-19-cores-1-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-19-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003ewbb03\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-19-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e840071\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-19-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-27-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e27\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003ewbc03\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-27-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e840262\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-27-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-37-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e37\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003ewbd03\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-37-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e840256\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/marine-cable\/prysmian-and-draka-cable-37-cores-2-5-cross-section-core-rfcu-0-6-1kv-power-and-control-or-lighting-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7510454763583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/RFCU_0.6_1kV_Power_Control_Cable-lg.jpg?v=1571729667"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/prysmian-and-draka-cable-rfcu-0-6-1kv-power-and-control-or-lighting-cable.oembed?page=3","provider":"NassauElectrical","version":"1.0","type":"link"}