{"title":"Prysmian and Draka Cable Pipeline Sensing Temperature and Strain Armored Cable","description":"","products":[{"product_id":"prysmian-and-draka-cable-pipeline-sensing-temperature-and-strain-armored-cable","title":"Prysmian and Draka Cable Pipeline Sensing Temperature and Strain Armored Cable","description":"Prysmian and Draka Cable Pipeline Sensing Temperature and Strain Armored Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable Pipeline Sensing Temperature and Strain Armored Cable. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Prysmian Cable Price, Prysmian Cable Quote, Prysmian Cable, Draka Cable, Pipeline Sensing Temperature and Strain Armored Cable, Pipeline Sensing Cable, Sensing Temperature Cable, Strain Armored Cable, Strain Sensing Cable, Armored Cable, Fiber Optic Cable, Single Armor Cable, Single Jacket Cable, Single-mode fiber Type Cable\"\u003e\n\u003cp\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003ePrysmian’s pipeline sensing cable is buried alongside pipelines to provide both leak detection through temperature sensing and detect ground movement through strain sensing. Optical fibers can also be used for telecommunications and data applications. 2.5mm simplex tight buffered fiber units are used for strain sensing and loose tube units are available for temperature sensing or data\/communications. Gel-free tubes are recommended for natural gas pipelines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Snapshot\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e: Direct buried pipeline leak and\/or ground movement strain detection\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConstructions\u003c\/strong\u003e: Single armor\/single jacket\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCount\u003c\/strong\u003e: 2 to 3 strain sensing fibers, up to 48 leak detection for data\/tecommunications fibers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFiber Types\u003c\/strong\u003e: ITUG652.D single-mode fiber\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions\u003c\/strong\u003e: Gel filed or dry buffer tubes and simplex units\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSimilar Alternatives\u003c\/strong\u003e: Express LT single armor\/single jacket for leak detection only\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance\u003c\/strong\u003e: Loose tube units per GR20 \u0026amp; ICEA 640, simplex units per GR-409 \u0026amp; ICEA 596\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePipeline Sensing Cable\u003c\/strong\u003e:\u003cbr\u003e • Temperature sensing provides fast leak detection in pipelines\u003cbr\u003e • Strain sensing can be used to detect ground\/pipe line movement\u003cbr\u003e • Fibers can also be used for data or telecommunications\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexbile Polypropylene Buffer Tube\u003c\/strong\u003e:\u003cbr\u003e • Buffer tubes contain temperature sensing and data\/telecommunications fibers\u003cbr\u003e • Available with gel or dry buffer tubes\u003cbr\u003e • Gel tubes have a faster leak detection response time\u003cbr\u003e • Zero fiber strain up to the residual load provides optimum SBS sensing\u003cbr\u003e • Inceased flexibility and superior kink resistance\u003cbr\u003e • Facilitates easy route management in closures, eliminates needs for closure transportation tubes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSimplex Units for Strain Sensing\u003c\/strong\u003e: Allows monitoring of ground or pipeline movement\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDry Water Blocking Technology\u003c\/strong\u003e:\u003cbr\u003e • Dry buffer tubes recommended for natural gas pipeline leak detection\u003cbr\u003e • Drycore design permits rapid cable preparation and termination\u003cbr\u003e • Dry water blocking materials are easily removed\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eezPrep Corrugated Armor\u003c\/strong\u003e:\u003cbr\u003e • Provides additional mechanical protection needed for buried environments\u003cbr\u003e • Special coating reduces time and effort to remove jacket\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003eouter diameter\u003c\/td\u003e\n\u003ctd\u003eweight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e≤ 48 loose tube fibers plus 2 strain sensing fibers\u003cbr\u003e ≤ 36 loose tube fibers plus 3 strain sensing fibers\u003c\/td\u003e\n\u003ctd\u003e0.43 inches (10.9 mm)\u003c\/td\u003e\n\u003ctd\u003e50 lb\/kft (75 kg\/km)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e \u003cstrong\u003eMain mechanical and environmental properties\u003c\/strong\u003e\n\u003cp\u003eCable is tested per Telcordia GR-20 and ICEA 640 per the below tables. Loose tube units are tested to the acceptance criterial for GR-20 and simplex units are tested to the GR-409 acceptance criteria.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003etest\u003c\/td\u003e\n\u003ctd\u003estandard\u003c\/td\u003e\n\u003ctd\u003especified value\u003c\/td\u003e\n\u003ctd\u003eacceptance criteria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003etemperature cycling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eloose tube units\u003c\/td\u003e\n\u003ctd\u003etelcordia gr-20\u003c\/td\u003e\n\u003ctd\u003e-40°c to +70°c\u003c\/td\u003e\n\u003ctd\u003egr-20: r6-69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esimplex units\u003c\/td\u003e\n\u003ctd\u003etelcordia gr409\u003c\/td\u003e\n\u003ctd\u003e-40°c to +70°c\u003c\/td\u003e\n\u003ctd\u003egr-409: r6-78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003emechanical tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eloose tube units\u003c\/td\u003e\n\u003ctd\u003etelcordia gr-20\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003ecable tested to gr20 test\n\u003cdiv\u003emethods\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003egr-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003esimplex units\u003c\/td\u003e\n\u003ctd\u003etelcordia gr409\u003c\/td\u003e\n\u003ctd\u003egr-409\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"4\"\u003ewater penetration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003etelcordia gr-20\u003c\/td\u003e\n\u003ctd\u003esample=1m, water =1m, 24h\u003c\/td\u003e\n\u003ctd\u003egr-20 : r6-75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e \u003cstrong\u003eTemperature Range\u003c\/strong\u003e \u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eshipping and storage:\u003c\/td\u003e\n\u003ctd\u003einstallation:\u003c\/td\u003e\n\u003ctd\u003eoperation:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-40° f to +167° f\u003c\/td\u003e\n\u003ctd\u003e-14° f to +140° f\u003c\/td\u003e\n\u003ctd\u003e-40° f to +158° f\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e(-40° c to +75° c)\u003c\/td\u003e\n\u003ctd\u003e(-10° c to +60° c)\u003c\/td\u003e\n\u003ctd\u003e(-40° c to +70° c)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e \u003cstrong\u003eMechanical Specifications\u003c\/strong\u003e \u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003eminimum bending load:\u003c\/td\u003e\n\u003ctd\u003einstallation tensile load:\u003c\/td\u003e\n\u003ctd\u003elong term tensile load:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eunder tension\u003c\/td\u003e\n\u003ctd\u003eno tension\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e600 lbf (2700 n)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e180 lbf (800 n)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e20 x cable diameter\u003c\/td\u003e\n\u003ctd\u003e10 x cable diameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187704021055,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Pipeline_20Sensing_20Cable-lg.jpg?v=1571729278"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/prysmian-and-draka-cable-pipeline-sensing-temperature-and-strain-armored-cable.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}