{"title":"Prysmian and Draka Cable 8 AWG to 1111 MCM Bostrig Type P Single Conductor Armored and Sheathed 600V and 2000V Power Cable","description":"","products":[{"product_id":"prysmian-and-draka-cable-1-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t36759","title":"Prysmian and Draka Cable 1 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36759","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 1 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36759\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 1 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36759. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T36759, 1 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e46.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.720\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e18.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.143\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.47\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.110\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.361\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e158\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e518\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e197\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e194\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e208\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e281\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e510\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e760\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV-1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT36759\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185870323775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg.jpg?v=1571728918"},{"product_id":"prysmian-and-draka-cable-1-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable-t26030","title":"Prysmian and Draka Cable 1 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26030","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 1 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26030\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 1 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26030. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26030, 1 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e46.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.680\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e17.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e178\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e584\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e197\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e194\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e208\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e281\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e520\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e775\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS-1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26030\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185870422079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_c2ba7996-2467-45e1-b137-8267ca69f7c3.jpg?v=1571728918"},{"product_id":"prysmian-and-draka-cable-1-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t36760","title":"Prysmian and Draka Cable 1\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36760","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 1\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36760\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 1\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36760. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T36760, 1\/0 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e1\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e56.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.750\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e19.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.115\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.38\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.108\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.354\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e168\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e551\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e223\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e227\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e243\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e319\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e580\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e865\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV-1\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT36760\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185873993791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_1ab05d5a-1573-4218-a5be-1bd42c545c11.jpg?v=1571728919"},{"product_id":"prysmian-and-draka-cable-1-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable-t26031","title":"Prysmian and Draka Cable 1\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26031","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 1\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26031\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 1\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26031. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Browse our selection of Prysmian and Draka Cable 1\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26031. Click for a free quote.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e1\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e56.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.710\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e18.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e190\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e623\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e223\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e227\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e243\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e319\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e605\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e900\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS-1\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26031\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185874681919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_9a726d36-1abe-4159-a449-d51c0f6b7873.jpg?v=1571728919"},{"product_id":"prysmian-and-draka-cable-1111-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t26042","title":"Prysmian and Draka Cable 1111 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26042","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 1111 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26042\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 1111 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26042. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26042, 1111 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e1111\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e563.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.110\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.890\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e48.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e257\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e843\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e942\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e1,025\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e1,098\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1,374\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e4,730\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e7,040\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV(HD)-1111\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26042\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185885691967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_b1a43a0a-99ba-42f8-a11b-4c305873efda.jpg?v=1571728923"},{"product_id":"prysmian-and-draka-cable-2-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t36742","title":"Prysmian and Draka Cable 2 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36742","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 2 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36742\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 2 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36742. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T36742, 2 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e30.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.620\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e15.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.178\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.58\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.112\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.367\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e160\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e525\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e162\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e169\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e181\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e217\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e395\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e590\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV-2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT36742\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185938022463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_aafe718b-9037-4221-a01d-ffa933a4560e.jpg?v=1571728969"},{"product_id":"prysmian-and-draka-cable-2-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable-t26029","title":"Prysmian and Draka Cable 2 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26029","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 2 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26029\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 2 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26029. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26029, 2 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e33.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.610\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e15.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e187\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e613\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e162\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e169\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e181\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e217\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e405\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e605\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS-2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26029\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185938120767,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_8f1139bd-ac98-4830-8e2f-fd3e4006da62.jpg?v=1571728969"},{"product_id":"prysmian-and-draka-cable-2-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t36761","title":"Prysmian and Draka Cable 2\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36761","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 2\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36761\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 2\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36761. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T36761, 2\/0 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e2\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e66.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.790\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e20.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.095\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.105\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.344\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e184\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e604\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e250\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e262\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e281\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e354\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e690\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1,025\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV-2\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT36761\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185987960895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_5168c012-f9ce-4144-83eb-000ccfa99bc5.jpg?v=1571728975"},{"product_id":"prysmian-and-draka-cable-2-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable-t26032","title":"Prysmian and Draka Cable 2\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26032","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 2\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26032\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 2\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26032. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Browse our selection of Prysmian and Draka Cable 2\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26032. Click for a free quote.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e2\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e67.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.750\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e19.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.09\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e212\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e695\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e250\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e262\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e281\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e354\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e665\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e990\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS-2\/0\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26032\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185988091967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_63164de7-8324-4fd4-8ea4-a8dde5d9672b.jpg?v=1571728975"},{"product_id":"prysmian-and-draka-cable-262-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t26035","title":"Prysmian and Draka Cable 262 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26035","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 262 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26035\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 262 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26035. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26035, 262 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e262\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e133.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.100\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e27.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.06\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e162\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e531\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e382\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e407\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e436\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e559\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,360\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2,025\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV(HD)-262\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26035\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7186000838719,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_d581677d-8e6d-4129-90b0-66cc1bc4a6ac.jpg?v=1571728999"},{"product_id":"prysmian-and-draka-cable-3-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t36758","title":"Prysmian and Draka Cable 3 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36758","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36758\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36758. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T36758, 3 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e25.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.620\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e15.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.222\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.73\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.115\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.377\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e148\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e485\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e142\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e146\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e156\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e195\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e345\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e515\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV-3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT36758\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7187563937855,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_10e06c2c-4f2c-4247-891f-69f5d8c9a648.jpg?v=1571729219"},{"product_id":"prysmian-and-draka-cable-3-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable-t26028","title":"Prysmian and Draka Cable 3 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26028","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26028\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26028. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26028, 3 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e27.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.560\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e14.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e173\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e567\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e142\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e146\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e156\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e195\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e335\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e500\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS-3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26028\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7187563970623,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_17171a2d-8850-4986-b147-5fd69a9fe825.jpg?v=1571729219"},{"product_id":"prysmian-and-draka-cable-3-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t27068","title":"Prysmian and Draka Cable 3\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T27068","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T27068\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T27068. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T27068, 3\/0 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e3\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e92.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.940\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e23.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.079\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.105\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.344\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e216\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e708\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e304\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e300\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e321\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e437\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e935\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1,390\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV-3\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT27068\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187579076671,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_b96ddcb6-7f69-4af3-a053-ad125ba88fc9.jpg?v=1571729222"},{"product_id":"prysmian-and-draka-cable-3-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable-t26033","title":"Prysmian and Draka Cable 3\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26033","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 3\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26033\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 3\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26033. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Browse our selection of Prysmian and Draka Cable 3\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26033. Click for a free quote.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e3\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e92.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.830\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e21.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e245\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e804\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e304\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e300\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e321\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e437\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e900\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1,340\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS-3\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26033\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187579174975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_df45f8c8-c3cc-4a64-9fbe-5f202b46d42a.jpg?v=1571729222"},{"product_id":"prysmian-and-draka-cable-313-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t26036","title":"Prysmian and Draka Cable 313 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26036","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 313 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26036\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 313 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26036. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26036, 313 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e313\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e158.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.170\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e29.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.06\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e175\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e574\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e426\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e455\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e487\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e617\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,595\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2,375\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV(HD)-313\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26036\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187582451775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_bcfc9654-bf7e-413b-a38e-865bbbc0398c.jpg?v=1571729223"},{"product_id":"prysmian-and-draka-cable-373-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t26037","title":"Prysmian and Draka Cable 373 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26037","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 373 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26037\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 373 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26037. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26037, 373 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e373\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e189.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.230\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e31.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.05\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e189\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e620\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e476\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e516\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e553\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e692\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,820\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2,710\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV(HD)-373\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26037\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187589070911,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_fa7ba2a2-bb4d-4100-96bd-0ed18f46ac6d.jpg?v=1571729245"},{"product_id":"prysmian-and-draka-cable-4-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t36757","title":"Prysmian and Draka Cable 4 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36757","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36757\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36757. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T36757, 4 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e21.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.580\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e14.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.279\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.92\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.120\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.394\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e131\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e430\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e122\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e128\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e137\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e158\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e300\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e445\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV-4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT36757\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187594608703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_1258f042-f1b3-4594-8745-a8399511c873.jpg?v=1571729246"},{"product_id":"prysmian-and-draka-cable-4-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable-t26027","title":"Prysmian and Draka Cable 4 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26027","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26027\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26027. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26027, 4 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e21.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.540\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e13.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e153\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e502\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e122\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e128\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e137\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e158\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e300\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e445\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS-4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26027\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187594674239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_585e6015-9ee9-4f4b-97e2-a0c890fb9457.jpg?v=1571729246"},{"product_id":"prysmian-and-draka-cable-4-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t26034","title":"Prysmian and Draka Cable 4\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26034","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26034\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4\/0 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26034. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26034, 4\/0 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e4\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e112.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.040\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e26.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.07\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e146\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e479\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e344\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e351\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e376\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e495\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,190\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1,770\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV(HD)-4\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26034\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187606208575,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_dcd16877-38cf-435c-9ea7-1bc5cea44feb.jpg?v=1571729249"},{"product_id":"prysmian-and-draka-cable-444-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t26038","title":"Prysmian and Draka Cable 444 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26038","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 444 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26038\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 444 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26038. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26038, 444 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e444\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e225.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.300\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e33.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.05\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e205\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e672\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e531\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e588\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e630\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e772\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e2,125\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3,160\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV(HD)-444\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26038\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187608928319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_ddff0bf9-516b-4d6e-9cac-568a2e5bccad.jpg?v=1571729249"},{"product_id":"prysmian-and-draka-cable-5-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t36756","title":"Prysmian and Draka Cable 5 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36756","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 5 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36756\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 5 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36756. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T36756, 5 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e18.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.550\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e14.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.333\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e1.09\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.120\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.394\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e120\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e393\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e111\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e109\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e117\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e153\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e250\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e370\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV-5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT36756\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187613712447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_c47febdb-b3e1-4ae8-bb83-8d1a8d454d09.jpg?v=1571729250"},{"product_id":"prysmian-and-draka-cable-5-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable-t26026","title":"Prysmian and Draka Cable 5 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26026","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 5 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26026\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 5 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26026. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26026, 5 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e18.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.530\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e13.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e140\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e459\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e111\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e109\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e117\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e153\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e260\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e385\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS-5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26026\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187613745215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_be159fc9-0202-45b0-bd2c-1edddeb50793.jpg?v=1571729250"},{"product_id":"prysmian-and-draka-cable-535-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t26039","title":"Prysmian and Draka Cable 535 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26039","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 535 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26039\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 535 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26039. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Browse our selection of Prysmian and Draka Cable 535 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26039. Click for a free quote.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e535\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e271.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.430\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e36.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e200\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e656\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e596\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e630\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e675\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e871\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e2,530\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3,765\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV(HD)-535\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26039\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187621249087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_d364d8b3-ebb5-4eff-bc26-3ea2de3a2680.jpg?v=1571729251"},{"product_id":"prysmian-and-draka-cable-6-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t36755","title":"Prysmian and Draka Cable 6 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36755","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 6 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36755\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 6 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36755. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T36755, 6 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e12.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.520\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e13.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.442\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e1.45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.124\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.407\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e108\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e354\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e96\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e103\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e126\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e210\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e315\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV-6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT36755\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187629834303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_cf8ee901-ed73-4b80-bbcc-8ae093267627.jpg?v=1571729252"},{"product_id":"prysmian-and-draka-cable-6-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable-t26025","title":"Prysmian and Draka Cable 6 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26025","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 6 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26025\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 6 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26025. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26025, 6 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e12.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.480\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e12.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e126\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e413\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e96\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e103\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e126\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e205\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e305\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS-6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26025\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187629867071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_b3ac2e8d-eda3-4cc6-b56b-cf7e329ef6b4.jpg?v=1571729252"},{"product_id":"prysmian-and-draka-cable-646-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t26040","title":"Prysmian and Draka Cable 646 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26040","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 646 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26040\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 646 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26040. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26040, 646 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e646\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e327.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.510\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e38.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e216\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e708\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e670\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e731\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e783\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e979\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e2,975\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e4,425\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV(HD)-646\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26040\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187642810431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_7db6f32f-7359-40ac-a3b3-6f6487145ca9.jpg?v=1571729254"},{"product_id":"prysmian-and-draka-cable-777-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t26041","title":"777 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26041","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 777 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26041\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 777 MCM Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T26041. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26041, 777 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e777\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e394.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.640\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e41.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e236\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e774\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e754\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e822\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e881\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1,101\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e3,475\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e5,170\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV(HD)-777\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26041\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7187655229503,"sku":"","price":34.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_198c40b7-3fe6-4a63-874f-780527b7d792.jpg?v=1571729257"},{"product_id":"prysmian-and-draka-cable-8-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cable-t36754","title":"Prysmian and Draka Cable 8 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36754","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 8 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36754\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 8 AWG Bostrig Type P Single Conductor Armored and Sheathed 2000V Power Cable T36754. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T36754, 8 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e7.57\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.460\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e11.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.696\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e2.28\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.138\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.453\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e82\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e269\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e67\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e72\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e77\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e155\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e230\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS2KV-8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT36754\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187659423807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_2127d09c-fd04-418e-8343-ca59302aca43.jpg?v=1571729258"},{"product_id":"prysmian-and-draka-cable-8-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable-t26024","title":"Prysmian and Draka Cable 8 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26024","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 8 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26024\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 8 AWG Bostrig Type P Single Conductor Armored and Sheathed 600V Power Cable T26024. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, 8 AWG to 1111 MCM Bostrig Type P Cable, 8 AWG to 1111 MCM Bostrig Type P Cable Price, 8 AWG to 1111 MCM Bostrig Type P Cable Quote, Single Conductor Armored and Sheathed 600V and 2000V Cable, Single Conductor Armored and Sheathed 600V and 2000V Cable Price,  Single Conductor Armored and Sheathed 600V and 2000V Cable Quote, T26024, 8 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic\n        Neoprene (Type N) also available as an option. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e\n        • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e\n        • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR \n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e\n        • Superior resistance to oil, abrasion, moisture,\n        sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior\n        flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature\n        results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance\n        with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and\n        IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 600V and performance\n        requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e\n        • Armored and sheathed cables suitable for use in\n        Class 1\u003cbr\u003e\n        • Division 1 and Zone 1 hazardous locations\n        offshore\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e7.57\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e10.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e2.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e95\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e311\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 95ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e67\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @ 100ºc\u003c\/td\u003e\n                    \u003ctd\u003e72\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity measured @110ºc\u003c\/td\u003e\n                    \u003ctd\u003e77\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity measured @ 125ºc\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e90\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e160\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e240\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBS-8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003eT26024\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187659456575,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_20Armored_20and_20Sheathed-lg_ae86636e-af3a-4a0c-885b-fe7688e68b94.jpg?v=1571729258"},{"product_id":"prysmian-and-draka-cable-8-awg-to-1111-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-600v-and-2000v-power-cable","title":"Prysmian and Draka Cable 8 AWG to 1111 MCM Bostrig Type P Single Conductor Armored and Sheathed 600V and 2000V Power Cable","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed stranded tinned copper nper ASTM B 33. A polyester tape separator is used over the conductor. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. Thickness as shown in tables on opposite page. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant Thermosetting CPE (Chlorinated Polyethylene) applied over the armor in accordance with the requirements of IEEE-1580-2010. Thickness as shown in tables on opposite page. Arctic Neoprene (Type N) also available as an option. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Bostrig™ Type P Marine and Offshore Cable is primarily designed for power, control, signal, and instrumentation applications for offshore and land drilling rigs, marine vessels, and offshore production facilities. \u003cbr\u003e • Bostrig™ cables have excellent resistance to oil, abrasion, moisture, vibration, sunlight, and ester based mud (Type P- MR). They are suitable for use in Class 1, Division 1 offshore applications (armored \u0026amp; sheathed). \u003cbr\u003e • The standard insulation has a continuous operating temperature of 125°C, allowing for higher ampacity levels. These cables also meet cold bend requirements of -40°C and cold impact of -35°C (CSA 22.2 N0. 0.3). \u003cbr\u003e • This product may be manufactured in an unarmored or armored and sheathed version. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e • UL 1309- Marine Shipboard Cable Type X110 \u003cbr\u003e • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e • Det Norske Veritas (DNV) \u003cbr\u003e • American Bureau of Shipping (ABS) \u003cbr\u003e • Transport Canada Approved AMS400-20-2 \u003cbr\u003e • Transport Canada 8700-20-2 \u003cbr\u003e • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e • United States Coast Guard-46CFR \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\/Ratings: \u003c\/strong\u003e\u003cbr\u003e • Superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e • High strand count conductors provide superior flexibility \u003cbr\u003e • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e • Meets IEEE standards for 600V and performance requirements of IEC standards for 0.6\/1 kV\u003cbr\u003e • Armored and sheathed cables suitable for use in Class 1\u003cbr\u003e • Division 1 and Zone 1 hazardous locations offshore\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003econductor \u003cbr\u003esize\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003etype\u003cbr\u003edesignation\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eprysmian \u003cbr\u003e and draka \u003cbr\u003e cable part number\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003eawg\/\u003cbr\u003e mcm\u003c\/td\u003e\n\u003ctd\u003emm²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e600v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-8-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.57\u003c\/td\u003e\n\u003ctd\u003espbs-8\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-8-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003eT26024\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-8-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-6-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003ctd\u003espbs-6\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-6-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003eT26025\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-6-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-5-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e18.6\u003c\/td\u003e\n\u003ctd\u003espbs-5\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-5-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003eT26026\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-5-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e21.5\u003c\/td\u003e\n\u003ctd\u003espbs-4\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003eT26027\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-3-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e27.2\u003c\/td\u003e\n\u003ctd\u003espbs-3\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-3-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003eT26028\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-3-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-2-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e33.7\u003c\/td\u003e\n\u003ctd\u003espbs-2\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-2-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003eT26029\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-2-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e46.1\u003c\/td\u003e\n\u003ctd\u003espbs-1\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003eT26030\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cable\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cab\"\u003e1\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e56.3\u003c\/td\u003e\n\u003ctd\u003espbs-1\/0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cab\"\u003eT26031\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-2-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cab\"\u003e2\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e67.6\u003c\/td\u003e\n\u003ctd\u003espbs-2\/0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-2-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cab\"\u003eT26032\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-2-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-3-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cab\"\u003e3\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e92.1\u003c\/td\u003e\n\u003ctd\u003espbs-3\/0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-3-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cab\"\u003eT26033\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-3-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-600v-power-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003e2000v\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-8-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7.57\u003c\/td\u003e\n\u003ctd\u003espbs2kv-8\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-8-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003eT36754\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-8-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-6-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12.5\u003c\/td\u003e\n\u003ctd\u003espbs2kv-6\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-6-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003eT36755\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-6-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-5-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e18.6\u003c\/td\u003e\n\u003ctd\u003espbs2kv-5\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-5-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003eT36756\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-5-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e21.5\u003c\/td\u003e\n\u003ctd\u003espbs2kv-4\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003eT36757\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-3-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e3\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e25.6\u003c\/td\u003e\n\u003ctd\u003espbs2kv-3\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-3-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003eT36758\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-3-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-2-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e30.7\u003c\/td\u003e\n\u003ctd\u003espbs2kv-2\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-2-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003eT36742\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-2-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e1\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e46.0\u003c\/td\u003e\n\u003ctd\u003espbs2kv-1\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003eT36759\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-cabl\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e1\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e56.3\u003c\/td\u003e\n\u003ctd\u003espbs2kv-1\/0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003eT36760\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-2-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e2\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e66.5\u003c\/td\u003e\n\u003ctd\u003espbs2kv-2\/0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-2-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003eT36761\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-2-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-3-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e3\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e92.1\u003c\/td\u003e\n\u003ctd\u003espbs2kv-3\/0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-3-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003eT27068\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-3-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e4\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e112.6\u003c\/td\u003e\n\u003ctd\u003espbs2kv(hd)-4\/0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003eT26034\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-0-awg-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-262-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e262\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e133.1\u003c\/td\u003e\n\u003ctd\u003espbs2kv(hd)-262\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-262-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003eT26035\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-262-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-313-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e313\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e158.7\u003c\/td\u003e\n\u003ctd\u003espbs2kv(hd)-313\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-313-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003eT26036\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-313-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-373-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e373\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e189.2\u003c\/td\u003e\n\u003ctd\u003espbs2kv(hd)-373\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-373-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003eT26037\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-373-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-444-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e444\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e225.2\u003c\/td\u003e\n\u003ctd\u003espbs2kv(hd)-444\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-444-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003eT26038\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-444-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-535-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e535\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e271.3\u003c\/td\u003e\n\u003ctd\u003espbs2kv(hd)-535\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-535-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003eT26039\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-535-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-646-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e646\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e327.5\u003c\/td\u003e\n\u003ctd\u003espbs2kv(hd)-646\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-646-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003eT26040\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-646-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-777-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e777\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e394.2\u003c\/td\u003e\n\u003ctd\u003espbs2kv(hd)-777\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-777-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003eT26041\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-777-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1111-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-c\"\u003e1111\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e563.0\u003c\/td\u003e\n\u003ctd\u003espbs2kv(hd)-1111\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1111-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-c\"\u003eT26042\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1111-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-2000v-power-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7424062160959,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Conductor_Armored_and_Sheathed-lg.jpg?v=1571729452"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/prysmian-and-draka-cable-8-awg-to-1111-mcm-bostrig-type-p-single-conductor-armored-and-sheathed-600v-and-2000v-power-cable.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}