{"title":"Prysmian and Draka Cable 4\/0 AWG to 1111 MCM Bostrig Type P-MR Single Conductor Armored Sheathed and Unarmored 2kV Power Cable","description":"","products":[{"product_id":"prysmian-and-draka-cable-1111-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-cable-026042m","title":"Prysmian and Draka Cable 1111 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026042M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 1111 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026042M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 1111 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026042M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026042M, 1111 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e1111\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e563.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.110\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.960\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e49.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.01\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e257\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e843\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e942\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e1,025\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e1,098\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1,374\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e4,770\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e7,100\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBM2KV(HD)-1111\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026042M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185885790271,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg.jpg?v=1571728923"},{"product_id":"prysmian-and-draka-cable-1111-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026023m","title":"Prysmian and Draka Cable 1111 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026023M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 1111 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026023M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 1111 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026023M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026023M, 1111 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e1111\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e563.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.110\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.930\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e49.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e257\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e843\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e942\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e1,025\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e1,098\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1,374\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e4,495\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e6,690\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPM2KV(HD)-1111\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026023M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7185885888575,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_9d18f0d7-a845-4560-8e52-6fda20d1ad75.jpg?v=1571728923"},{"product_id":"prysmian-and-draka-cable-262-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-cable-026035m","title":"Prysmian and Draka Cable 262 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026035M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 262 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026035M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 262 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026035M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026035M, 262 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e262\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e133.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.100\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e27.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.06\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e162\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e531\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e382\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e407\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e436\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e559\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,355\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2,015\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBM2KV(HD)-262\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026035M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7186001264703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_7f7bd8e8-e9b7-4fda-b561-a28367c74b01.jpg?v=1571728999"},{"product_id":"prysmian-and-draka-cable-262-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026016m","title":"Prysmian and Draka Cable 262 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026016M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 262 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026016M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 262 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026016M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026016M, 262 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e262\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e133.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.050\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e26.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.06\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e162\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e531\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e382\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e407\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e436\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e559\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,215\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1,810\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPM2KV(HD)-262\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026016M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cable","offers":[{"title":"Default Title","offer_id":7186001395775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_3f821f0a-373a-4741-9c7f-4645d79d367a.jpg?v=1571728999"},{"product_id":"prysmian-and-draka-cable-313-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-cable-026036m","title":"Prysmian and Draka Cable 313 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026036M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 313 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026036M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 313 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026036M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026036M, 313 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e313\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e158.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.170\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e29.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.06\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e175\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e574\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e426\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e455\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e487\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e617\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,570\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2,335\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBM2KV(HD)-313\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026036M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187582713919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_07434331-dc1d-49a4-a550-532ec10890fe.jpg?v=1571729223"},{"product_id":"prysmian-and-draka-cable-313-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026017m","title":"Prysmian and Draka Cable 313 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026017M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 313 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026017M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 313 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026017M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026017M, 313 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e313\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e158.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.130\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e28.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.06\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e175\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e574\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e426\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e455\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e487\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e617\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2,115\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPM2KV(HD)-313\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026017M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187582812223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_ebe977f4-f7c0-4e04-8f9c-bfc77a4b3cf0.jpg?v=1571729223"},{"product_id":"prysmian-and-draka-cable-373-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-cable-026037m","title":"Prysmian and Draka Cable 373 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026037M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 373 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026037M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 373 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026037M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026037M, 373 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e373\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e189.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.240\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e31.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.05\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e189\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e620\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e476\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e516\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e553\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e692\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,790\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2,665\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBM2KV(HD)-373\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026037M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187589333055,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_2241a880-0aa6-403e-a10a-4ed48304c495.jpg?v=1571729245"},{"product_id":"prysmian-and-draka-cable-373-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026018m","title":"Prysmian and Draka Cable 373 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026018M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 373 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026018M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 373 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026018M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026018M, 373 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e373\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e189.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.190\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e30.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.05\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e189\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e620\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e476\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e516\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e553\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e692\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,635\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2,435\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPM2KV(HD)-373\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026018M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187589398591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_d82c1e51-161b-4518-9d9b-984cbb393d19.jpg?v=1571729245"},{"product_id":"prysmian-and-draka-cable-4-0-awg-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-cable-026034m","title":"Prysmian and Draka Cable 4\/0 AWG Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026034M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4\/0 AWG Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026034M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4\/0 AWG Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026034M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026034M, 4\/0 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e4\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e112.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.040\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e26.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.07\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e146\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e479\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e335\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e351\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e376\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e495\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,185\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1,765\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003espbm2kv(hd)-4\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026034M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187606667327,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_f0ec2a09-5bb6-46c0-a8ee-7277e926083a.jpg?v=1571729249"},{"product_id":"prysmian-and-draka-cable-4-0-awg-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026015m","title":"Prysmian and Draka Cable 4\/0 AWG Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026015M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 4\/0 AWG Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026015M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4\/0 AWG Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026015M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026015M, 4\/0 AWG Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e4\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e112.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.980\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e24.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.07\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e146\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e479\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e335\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e351\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e376\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e495\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,060\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1,575\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPM2KV(HD)-4\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026015M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187606732863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_82053610-c875-4686-a051-cc8c74cf4608.jpg?v=1571729249"},{"product_id":"prysmian-and-draka-cable-4-0-awg-to-1111-mcm-bostrig-type-p-mr-single-conductor-armored-sheathed-and-unarmored-2kv-power-cable","title":"Prysmian and Draka Cable 4\/0 AWG to 1111 MCM Bostrig Type P-MR Single Conductor Armored Sheathed and Unarmored 2kV Power Cable","description":"Prysmian and Draka Cable 4\/0 AWG to 1111 MCM Bostrig Type P-MR Single Conductor Armored Sheathed and Unarmored 2kV Power Cable\u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 4\/0 AWG to 1111 MCM Bostrig Type P-MR Single Conductor Armored Sheathed and Unarmored 2kV Power Cable. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Browse our selection of Prysmian and Draka Cable 4\/0 AWG to 1111 MCM Bostrig Type P-MR Single Conductor Armored Sheathed and Unarmored 2kV Power Cable. Click for a free quote.\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThis is a single conductor type P Bostrig cable that is designed to serve power at voltages up to 2kV. It is armored and sheathed for chemical and mechanical protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e \u003cbr\u003eBostrig Type P cable is a mud resistance cable that works well as a control, signal and instrumentation cable for petrofree drills applications.\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003econductor\u003cbr\u003e size\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003e\n\u003cbr\u003etype designation\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eprysmian and\u003cbr\u003edraka cable \u003cbr\u003enumber\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"color: #ffffff; background-color: #495682;\"\u003e\n\u003ctd\u003eawg\/\u003cbr\u003e mcm\u003c\/td\u003e\n\u003ctd\u003emm2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003earmored and sheathed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-0-awg-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e4\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e112.6\u003c\/td\u003e\n\u003ctd\u003espbm2kv(hd)-4\/0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-0-awg-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e026034M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-0-awg-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-262-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e262\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e133.1\u003c\/td\u003e\n\u003ctd\u003espbm2kv(hd)-262\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-262-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e026035M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-262-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-313-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e313\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e158.7\u003c\/td\u003e\n\u003ctd\u003espbm2kv(hd)-313\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-313-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e026036M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-313-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-373-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e373\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e189.2\u003c\/td\u003e\n\u003ctd\u003espbm2kv(hd)-373\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-373-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e026037M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-373-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-444-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e444\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e225.2\u003c\/td\u003e\n\u003ctd\u003espbm2kv(hd)-444\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-444-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e026038M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-444-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-535-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e535\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e271.3\u003c\/td\u003e\n\u003ctd\u003espbm2kv(hd)-535\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-535-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e026039M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-535-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-646-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e646\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e327.5\u003c\/td\u003e\n\u003ctd\u003espbm2kv(hd)-646\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-646-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e026040M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-646-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-777-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e777\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e394.2\u003c\/td\u003e\n\u003ctd\u003espbm2kv(hd)-777\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-777-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e026041M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-777-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1111-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-\"\u003e1111\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e563.0\u003c\/td\u003e\n\u003ctd\u003espbm2kv(hd)-1111\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1111-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-\"\u003e026042M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1111-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"7\"\u003eunarmored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-0-awg-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026015\"\u003e4\/0\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e112.6\u003c\/td\u003e\n\u003ctd\u003espm2kv(hd)-4\/0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-0-awg-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026015\"\u003e026015M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-4-0-awg-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026015\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-262-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026016\"\u003e262\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e133.1\u003c\/td\u003e\n\u003ctd\u003espm2kv(hd)-262\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-262-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026016\"\u003e026016M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-262-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026016\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-313-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026017\"\u003e313\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e158.7\u003c\/td\u003e\n\u003ctd\u003espm2kv(hd)-313\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-313-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026017\"\u003e026017M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-313-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026017\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-373-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026018\"\u003e373\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e189.2\u003c\/td\u003e\n\u003ctd\u003espm2kv(hd)-373\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-373-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026018\"\u003e026018M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-373-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026018\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-444-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026019\"\u003e444\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e225.2\u003c\/td\u003e\n\u003ctd\u003espm2kv(hd)-444\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-444-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026019\"\u003e026019M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-444-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026019\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-535-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026020\"\u003e535\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e271.3\u003c\/td\u003e\n\u003ctd\u003espm2kv(hd)-535\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-535-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026020\"\u003e026020M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-535-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026020\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-646-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026021\"\u003e646\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e327.5\u003c\/td\u003e\n\u003ctd\u003espm2kv(hd)-646\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-646-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026021\"\u003e026021M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-646-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026021\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-777-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026022\"\u003e777\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e394.2\u003c\/td\u003e\n\u003ctd\u003espm2kv(hd)-777\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-777-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026022\"\u003e026022M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-777-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026022\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1111-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-02602\"\u003e1111\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e563.0\u003c\/td\u003e\n\u003ctd\u003espm2kv(hd)-1111\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1111-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-02602\"\u003e026023M\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/type-p-cable-rig-marine-cable\/bostrig-type-p-cable\/prysmian-and-draka-cable-1111-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-02602\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187607126079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_8ef4ffcd-3d0d-4408-ad4a-f8d566a5eef2.jpg?v=1571729249"},{"product_id":"prysmian-and-draka-cable-444-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-cable-026038m","title":"Prysmian and Draka Cable 444 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026038M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 444 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026038M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 444 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026038M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026038M, 444 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e444\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e225.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.330\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e33.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.05\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e205\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e672\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e531\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e588\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e630\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e772\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e2,130\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3,170\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBM2KV(HD)-444\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026038M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187610435647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_36a08236-0f09-45a7-971d-55766e0ea2e6.jpg?v=1571729250"},{"product_id":"prysmian-and-draka-cable-444-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026019m","title":"Prysmian and Draka Cable 444 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026019M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 444 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026019M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 444 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026019M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026019M, 444 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e444\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e225.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.270\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e32.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.05\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e205\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e672\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e531\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e588\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e630\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e772\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e1,935\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2,880\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPM2KV(HD)-444\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026019M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187610468415,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_3ec3722a-a26f-463d-b903-616632ccc123.jpg?v=1571729250"},{"product_id":"prysmian-and-draka-cable-535-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-cable-026039m","title":"Prysmian and Draka Cable 535 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026039M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 535 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026039M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 535 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026039M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026039M, 535 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e535\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e271.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.420\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e36.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.01\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e200\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e656\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e596\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e630\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e675\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e871\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e2,470\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3,675\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBM2KV(HD)-535\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026039M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187623673919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_4a330829-0b94-4859-abd2-d89df82fe7bf.jpg?v=1571729251"},{"product_id":"prysmian-and-draka-cable-535-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026020m","title":"Prysmian and Draka Cable 535 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026020M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 535 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026020M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 535 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026020M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026020M, 535 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e535\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e271.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.360\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e34.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e200\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e656\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e596\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e630\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e675\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e871\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e2,260\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3,365\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPM2KV(HD)-535\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026020M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187623772223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_dd8c5ad9-c3ee-4a5b-b8ca-33dc3aa20dab.jpg?v=1571729251"},{"product_id":"prysmian-and-draka-cable-646-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-cable-026040m","title":"Prysmian and Draka Cable 646 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026040M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 646 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026040M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 646 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026040M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026040M, 646 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e646\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e327.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.520\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e38.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.01\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e216\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e708\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e670\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e731\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e783\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e979\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e3,050\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e4,540\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBM2KV(HD)-646\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026040M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187643301951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_0a7fe2c6-2f84-4a18-8b6f-94a74db4569c.jpg?v=1571729254"},{"product_id":"prysmian-and-draka-cable-646-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026021m","title":"Prysmian and Draka Cable 646 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026021M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 646 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026021M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 646 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026021M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026021M, 646 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e646\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e327.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.530\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e38.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e216\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e708\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e670\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e731\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e783\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e979\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e2,790\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e4,150\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPM2KV(HD)-646\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026021M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187643334719,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_f24869a0-de10-4abb-ad14-754a8bedbd03.jpg?v=1571729254"},{"product_id":"prysmian-and-draka-cable-777-mcm-bostrig-type-p-mr-single-conductor-armored-and-sheathed-2kv-power-cable-026041m","title":"Prysmian and Draka Cable 777 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026041M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 777 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026041M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 777 MCM Bostrig Type P-MR Single Conductor Armored and Sheathed 2kV Power Cable 026041M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026041M, 777 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e777\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e394.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.610\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e40.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.01\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e236\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e774\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e754\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e822\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e881\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1,101\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e3,570\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e5,315\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPBM2KV(HD)-777\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026041M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187655819327,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_68d732ac-788f-4077-a26f-b1e1fb1d7a4c.jpg?v=1571729257"},{"product_id":"prysmian-and-draka-cable-777-mcm-bostrig-type-p-mr-single-conductor-unarmored-2kv-power-cable-026022m","title":"Prysmian and Draka Cable 777 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026022M","description":"\n    \n        \u003ctitle\u003ePrysmian and Draka Cable 777 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026022M\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Prysmian and Draka Cable 777 MCM Bostrig Type P-MR Single Conductor Unarmored 2kV Power Cable 026022M. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Prysmian and Draka Cable Price, Prysmian and Draka Cable Quote, Prysmian and Draka Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Price, 4\/0 AWG to 1111 MCM Bostrig Type P-MR Cable Quote, Single Conductor Armored Sheathed Cable, Single Conductor Armored Sheathed Cable Price,  Single Conductor Armored Sheathed Cable Quote, Unarmored 2kV Power Cable, Unarmored 2kV Power Cable Cable Price, Unarmored 2kV Power Cable Quote, 026022M, 777 MCM Cable.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Soft annealed tinned copper per ASTM B 33, stranded as shown in table on opposite page. A mylar separator is used over the conductor. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Bostrig Type P chemically cross-linked polyolefin (XLPO), meeting IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Braided bronze in accordance with IEEE 1580. \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eSheath:\u003c\/strong\u003e Flame-Retardant XLPO applied over the armor, meeting requirements of Type L in IEEE 1580. Thickness as shown in tables on opposite page.\u003c\/p\u003e\n        \u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Bostrig Type P Mud Resistant Cable is primarily designed for power, control, signal, and instrumentation for marine vessels, and offshore production facilities. Instead of Polychloroprene (Neoprene), they are\n        sheathed in our proprietary elastomeric formulation which is not only mud-resistant but is qualified as a Low-Smoke Zero-Halogen (LSZH) cable in accordance with IEEE 45, IEEE 1580. \u003cbr\u003e\n        • This mud-resistant jacket is designed for use in areas where ester-based drilling muds and fluids are present. These cables are listed by ETL in accordance with IEEE 45 and type approved by DNV as resistant to NOVA Plus., Petrofree LE, and Petrofree drilling muds and fluids. The cable was tested in accordance with NEK 606 for 56 days at 70°C in each of the ester-based muds mentioned above. \u003cbr\u003e\n        • This product can also be manufactured in an unarmored version. \u003cbr\u003e\n        • Multiconductor power, control, and instrumentation cables are also available. \n        \u003cp\u003e\u003cstrong\u003eFeatures\/Ratings:\u003c\/strong\u003e\u003cbr\u003e\n        • Special ester-based mud resistant jacket also provides superior resistance to oil, abrasion, moisture, sunlight, crush and impact \u003cbr\u003e\n        • High strand count conductors provide superior flexibility \u003cbr\u003e\n        • Higher allowable conductor operating temperature results in increased ampacity \u003cbr\u003e\n        • Cold bend\/ cold impact of -40°\/ -35°C in accordance with CSA 22.2 No. 0.3 \u003cbr\u003e\n        • Flame retardant in accordance with IEEE 1202 and IEC 60332-3-22 Category A \u003cbr\u003e\n        • Meets IEEE standards for 2000V and performance requirements of IEC standards for 0.6\/1kV \u003cbr\u003e\n        • This product may be manufactured in an unarmored or armored and sheathed version \u003cbr\u003e\n        • Armored and sheathed cables suitable for use in Class 1 Division 1 and Zone 1 hazardous locations offshore \u003cbr\u003e\n        • Unarmored cables suitable for use in Class I, Division 2 zone 2 hazardous locations offshore \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApprovals:\u003c\/strong\u003e\u003cbr\u003e\n        • IEEE 1580 and IEEE 45- Marine Shipboard Cable \u003cbr\u003e\n        • UL 1309- Marine Shipboard Cable Type X110\u003cbr\u003e\n        • CSA 22.2 No. 245- Marine Shipboard Cable Type X110 \u003cbr\u003e\n        • Det Norske Veritas (DNV) \u003cbr\u003e\n        • American Bureau of Shipping (ABS) \u003cbr\u003e\n        • Transport Canada Approved AMS400-20-2 \u003cbr\u003e\n        • Transport Canada 8700-20-2 \u003cbr\u003e\n        • Lloyd’s Register of Shipping (LRS) \u003cbr\u003e\n        • United States Coast Guard-46CFR\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size awg\/mcm\u003c\/td\u003e\n                    \u003ctd\u003e777\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor size mm²\u003c\/td\u003e\n                    \u003ctd\u003e394.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness in\u003c\/td\u003e\n                    \u003ctd\u003e0.080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003esheath thickness mm\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) in\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1.650\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003ecable diameter (nominal) mm\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e41.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eimpedance (phase-neutral) ω\/kft\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e0.04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eimpedance (phase-neutral) ω\/km\u003c\/td\u003e\n                    \u003ctd\u003e0.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/kft)\u003c\/td\u003e\n                    \u003ctd\u003e0.10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003einductance (mh\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/ft)\u003c\/td\u003e\n                    \u003ctd\u003e236\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecapacitance (pf\/m)\u003c\/td\u003e\n                    \u003ctd\u003e774\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 95ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e754\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @ 100ºc)\u003c\/td\u003e\n                    \u003ctd\u003e822\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eampacity (measured @110ºc)\u003c\/td\u003e\n                    \u003ctd\u003e881\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003eampacity (measured @ 125ºc)\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1,101\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (lbs\/mft)\u003c\/td\u003e\n                    \u003ctd\u003e3,290\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable weight approximate (kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e4,895\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003etype designation\u003c\/td\u003e\n                    \u003ctd\u003eSPM2KV(HD)-777\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eprysmian and draka cable number\u003c\/td\u003e\n                    \u003ctd\u003e026022M\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Prysmian and Draka Cabe","offers":[{"title":"Default Title","offer_id":7187655884863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Single_20Conductor_20Armored_20Sheathed-lg_bb2837ef-948a-46a4-9f7b-e6175815f5b6.jpg?v=1571729257"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/prysmian-and-draka-cable-4-0-awg-to-1111-mcm-bostrig-type-p-mr-single-conductor-armored-sheathed-and-unarmored-2kv-power-cable.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}