{"title":"Type TC-ER - Control \u0026 Power Tray Cable Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry","description":"","products":[{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-10-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 10 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e475\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163660533823,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg.jpg?v=1571728291"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-12-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 12 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.863\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e592\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163660566591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_e37b34f0-0847-459c-91dd-9c9d9f54a7d7.jpg?v=1571728291"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-15-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 15 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.945\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e722\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163660664895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_ad15f63e-7ffa-44e4-9ae1-8f421ce90653.jpg?v=1571728291"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-19-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 19 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5119\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.042\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e894\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163660697663,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_1b63a350-17bd-4367-81fc-174e0d2c2573.jpg?v=1571728291"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-2-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 2 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.446\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163660795967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_0cc22289-4fa0-4c9b-9228-c7ffc7495ad2.jpg?v=1571728291"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-20-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 20 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.067\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163660828735,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_9a5f6de5-bc74-465e-b251-44ec59daa49f.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-3-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 3 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.475\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e154\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163660861503,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_b87d65d8-795e-4e38-8e0e-81f93a0dcd06.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-4-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 4 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.549\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163660959807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_231cd4a3-25ed-4735-a3cf-967d86f52a61.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-5-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 5 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.576\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e256\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163660992575,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_b2aba62e-8932-48d7-a875-2794f6ddbd25.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-6-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 6 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e298\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163661090879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_ab10378a-e43d-45ef-83ff-f6468b55bb60.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-7-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 7 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.651\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163661123647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_ed6d20e7-16b1-4e60-a151-624d225dee45.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-8-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 8 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.698\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e398\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163661156415,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_b603e088-b38a-4ef6-af54-aa10f7474695.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-10-awg-9-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 10 AWG - 9 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5109\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e431\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163661779007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_b240f6d7-48a9-4c20-9f6e-fc736839f452.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-10-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 10 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.676\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163661811775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_7c6d9d6d-0df9-4001-af1b-5a46586ca873.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-12-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 12 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5212\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.727\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e389\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163661844543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_366fb094-a881-465b-93e1-1317f23bf80a.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-15-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 15 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5215\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.799\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e475\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163661942847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_6daa0a47-b0e2-497c-8615-5c589fb9ca14.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-19-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 19 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5219\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.922\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163661975615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_2077a163-a7ae-4d1e-8e8f-d310a73e943f.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-2-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 2 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.398\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163662172223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_0c5a479b-b18d-4600-8081-f1935c4eef28.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-25-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 25 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e796\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163662204991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_3edfd0ee-49d2-4aa2-94af-8d7c85501c5f.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-3-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 3 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.423\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163662237759,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_ba823455-2805-4f4e-a257-61948fe99c32.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-4-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 4 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163662270527,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_fb6e642e-bc5d-4d88-a676-3976dc99de37.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-5-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 5 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.484\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e167\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163662368831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_3e1ad6b8-f8f5-482b-9d08-77c5c696b76f.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-6-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 6 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.541\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163662663743,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_4360d25f-f9b4-4efd-921e-f5e38d66b5db.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-7-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 7 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5207\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163662762047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_bc989937-ec7d-4aaa-8d57-1e45cd9cfa25.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-8-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 8 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.617\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e272\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163662794815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_4b6b304c-d9b4-4346-acb3-386e18495fa3.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-12-awg-9-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 12 AWG - 9 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.152\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.647\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163662827583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_d0da62c8-8a08-4b44-b2ff-22aab7bc12e9.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-10-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 10 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.607\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e238\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163662958655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_4ecf0957-aafb-41da-9e85-efb893a521a5.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-12-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 12 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5412\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.652\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e279\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163662991423,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_fe9520b7-f329-438d-a2cb-eb4c029490cb.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-15-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 15 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e339\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163663155263,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_71f560e7-1b6e-41b4-aaee-6fe06d3981f2.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-19-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 19 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5419\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e438\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163663253567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_b8f83d08-16d3-4f7e-9880-3a68f5ee5152.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-2-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 2 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163663286335,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_a92457b5-7f61-4f68-9484-1ed840cc10e4.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-25-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 25 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.927\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e566\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163663384639,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_08d92b12-7ca1-441d-a203-4f31e7898999.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-3-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 3 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163663417407,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_b8c2e33c-a7d8-462b-b37c-217f13c2a99b.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-4-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 4 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163663646783,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_f2a59609-c6eb-4ecd-a7ab-2778d7851095.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-5-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 5 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.435\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163663745087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_7d20dbf0-b1e8-4026-9085-583086612a46.jpg?v=1571728292"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-6-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 6 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5406\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.458\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163663777855,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_b67361d7-d121-422e-8f84-834678f8d6fa.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-7-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 7 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5407\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.492\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163663810623,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_255d21cc-8e4c-47f7-b4ae-ceac5e9b9cef.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-8-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 8 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5408\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.555\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e198\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163663908927,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_8bfd207a-cc86-4e7e-a75d-fe1ffccbfd69.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-14-awg-9-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 14 AWG - 9 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5409\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.133\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.582\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e218\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163663941695,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_7285da30-9bb2-49dd-a741-aeecc8905fa0.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-16-awg-10-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 16 AWG - 10 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.553\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e177\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163663974463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_c640eda3-56a7-4307-a213-01564d04e001.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-16-awg-12-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 16 AWG - 12 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5612\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.593\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163664072767,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_845ad472-c054-44c1-ab73-c9a115299607.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-16-awg-15-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 16 AWG - 15 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5615\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.648\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163664105535,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_45f7bf78-b437-41d4-8231-3fbe37d8c4a6.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-16-awg-19-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 16 AWG - 19 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5619\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.713\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163665121343,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_73a084c9-4747-423d-a98b-91b6d3169674.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-16-awg-2-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 16 AWG - 2 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e49\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCable Identification 18-16 AWG:\u003c\/strong\u003e\u003cbr\u003e “ADVANCED DIGITAL CABLE, INC. X AWG X CDRS TYPE RFH-2 TC OR TC-ER (UL) 90C WET OR DRY 600V SUN RES DIR BUR FT4\/ IEEE 1202 E195597 MADE IN USA”\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Identification 14-10 AWG:\u003c\/strong\u003e\u003cbr\u003e “ADVANCED DIGITAL CABLE, INC. XX AWG X CDRS TYPE XHHW-2 TC OR TC-ER (UL) 90C WET OR DRY 600V SUN RES DIR BUR FT4\/ IEEE 1202 E195597 MADE IN USA”\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163666071615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_706335b7-53bd-49ef-a369-6ad271cab39d.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-16-awg-25-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 16 AWG - 25 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5625\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163666104383,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_175ec0ae-5963-4166-8184-74305d668442.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-16-awg-3-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 16 AWG - 3 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5603\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163666202687,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_e9c21001-8df2-4c6c-b815-9435b61dc594.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-16-awg-4-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 16 AWG - 4 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.379\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163666235455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_cc0a5b4c-821a-4603-a394-d5bf484f1955.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-16-awg-5-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 16 AWG - 5 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5605\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163666628671,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_9146b572-ab2c-41de-9cd6-89044f99ddb6.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-16-awg-6-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 16 AWG - 6 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5606\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.427\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163668889663,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_9621bec2-84b9-4390-8ed6-a41ba8d9178a.jpg?v=1571728293"},{"product_id":"type-tc-er-control-power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry-16-awg-7-conductors","title":"TYPE TC-ER - CONTROL \u0026 POWER TRAY CABLE Unshielded XLPE Insulation with Overall PVC Jacket 18 - 10 AWG - 600 Volts - 90°C Wet\/Dry - 16 AWG - 7 Conductors","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eProduct Code\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5607\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eStrands\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eXLPE Insulation Thickness (Mils)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eApproximate O.D. (Inches)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eOA Jkt. Thick. (MILS)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eAppr. O.D. (IN)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.447\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAppr. Weight Lbs.\/ M Ft\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e119\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTYPE TC-ER - CONTROL \u0026amp; POWER TRAY CABLE\u003c\/li\u003e\n\u003cli\u003eUnshielded XLPE Insulation with Overall PVC Jacket\u003c\/li\u003e\n\u003cli\u003e18 - 10 AWG • 600 Volts • 90°C Wet\/Dry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDescription:\u003c\/strong\u003e\u003cbr\u003e ADC’s Type TC-ER multi-conductor cables have a XLPE insulation with an overall gas and oil resistant PVC jacket.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Suitable for use in Class 1 or 2, Division 2 hazardous locations and for installation in trays, wireways, troughs, channels, ducts and conduit. Expressly approved for direct burial, wet or dry locations and outdoors in cable trays where sunlight resistant rating is required. Intended for control, power, lighting, telemetering, signals and relay or trafc control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft Drawn Annealed Bare Copper per ASTM B-3 and B-8. Concentric 7 strand. Concentric 19 strand available upon request as well as Tinned Copper.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation: XLPE:\u003c\/strong\u003e\u003cbr\u003e Thickness: Per UL 66 table 4.8 for RFH-2, UL 44 table 12 for XHHW-2.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCabling:\u003c\/strong\u003e\u003cbr\u003e Conductors are assembled with fllers in the core as needed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSeperator:\u003c\/strong\u003e\u003cbr\u003e Mylar\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e\u003cbr\u003e A black, fame resistant, Polyvinyl Chloride (PVC) jacket is extruded over the assembly. The surface profle shall approximate that of the interior assembly. A rip cord shall be inserted under the jacket for ease of stripping.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e ICEA Method 1 Tables E-1, E-2 \u0026amp; Method 4.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustry Listings and Standards:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUL Listed as TC-ER per UL Standard 1277*\u003c\/li\u003e\n\u003cli\u003eRated -40°C to 90°C\u003c\/li\u003e\n\u003cli\u003eOSHA Acceptable\u003c\/li\u003e\n\u003cli\u003eNEC Articles 392\u003c\/li\u003e\n\u003cli\u003eCSA FT4\u003c\/li\u003e\n\u003cli\u003eIEEE 1202 70,000 BTU Flame Test\u003c\/li\u003e\n\u003cli\u003eASTM - All Applicable Standards\u003c\/li\u003e\n\u003cli\u003e*UL 1277 requires a ground or three conductors to be rated ER\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7163669839935,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/5802-lg_6ec67723-cfd9-4e28-a3eb-c6f38e758477.jpg?v=1571728293"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/power-tray-cable-unshielded-xlpe-insulation-with-overall-pvc-jacket-18-10-awg-600-volts-90-c-wet-dry.oembed?page=4","provider":"NassauElectrical","version":"1.0","type":"link"}