{"title":"Interlocked Armor Control Cable 600 Volt UL Type MC XLP VW-1 XHHW-2 Aluminum Armor Copper Conductors","description":"","products":[{"product_id":"interlocked-armor-control-cable-10-gauge-12-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 10 Gauge - 12 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e880\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1.13\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU05\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC05\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151863431231,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_0dcccfe1-993a-48f9-a6c5-86bd298e594f.jpg?v=1571727221"},{"product_id":"interlocked-armor-control-cable-10-gauge-15-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 10 Gauge - 15 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e15\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e965\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1.18\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU05\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC05\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151863463999,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_f1688fd3-344d-4193-b04a-e36ba1458d57.jpg?v=1571727221"},{"product_id":"interlocked-armor-control-cable-10-gauge-19-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 10 Gauge - 19 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e19\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1300\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1.27\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU06\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC06\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151863857215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_15c531d8-8119-45a6-907d-9280843b1195.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-10-gauge-2-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 10 Gauge - 2 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e230\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.70\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865528383,"sku":"","price":3.3,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_6a157cc3-1f3f-46d7-89dc-8561fd5c65e3.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-10-gauge-25-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 10 Gauge - 25 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e25\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1500\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1.42\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU06\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC06\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865561151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_be2947b8-c333-4990-8ab2-0430bb11d657.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-10-gauge-3-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 10 Gauge - 3 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e3\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e300\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.72\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865626687,"sku":"","price":2.95,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_c60bee70-4884-4525-888c-ba3ebf7a9109.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-10-gauge-37-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 10 Gauge - 37 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e37\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e2450\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1.64\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU06\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC07\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865659455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_8a4a7938-c938-4268-9005-ee3a4853b8b2.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-10-gauge-4-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 10 Gauge - 4 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e4\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e345\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.79\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865724991,"sku":"","price":3.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_22d5d555-a6cf-4cb1-9617-c48cd74c6928.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-10-gauge-5-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 10 Gauge - 5 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e5\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e450\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865757759,"sku":"","price":4.83,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_a5ea4a5f-f78a-4304-98ca-ffbb7e42ddb5.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-10-gauge-7-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 10 Gauge - 7 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e560\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.89\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865790527,"sku":"","price":4.89,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_dc429001-c4a1-41c6-ab2e-d3392c78fefd.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-10-gauge-9-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 10 Gauge - 9 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e9\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e640\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.99\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865823295,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_c97baaff-044f-4d59-8a0f-44f13d1d97db.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-12-gauge-02-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 12 Gauge - 02 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e185\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.65\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU02\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865856063,"sku":"","price":1.78,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_723981cb-eff6-4b63-8386-225b0f6ea2d5.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-12-gauge-03-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 12 Gauge - 03 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e3\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e215\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.69\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865888831,"sku":"","price":2.38,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_4f7f836c-117c-433a-ad37-499e47beae3d.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-12-gauge-10-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 12 Gauge - 10 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e560\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.95\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865921599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_cb644229-01eb-4811-85ee-77ca74373756.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-12-gauge-12-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 12 Gauge - 12 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e615\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1.00\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC05\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865954367,"sku":"","price":4.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_532ab412-bd2a-4186-b7d7-058f53b3b7ec.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-12-gauge-15-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 12 Gauge - 15 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e15\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e680\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1.04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU05\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC05\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151865987135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_7be6abcd-3f75-49bb-9e44-3a3b70b943ca.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-12-gauge-19-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 12 Gauge - 19 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e19\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e900\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1.16\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU05\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC05\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866019903,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_76fafee1-a97e-4b73-84f4-833a7ccf1528.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-12-gauge-25-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 12 Gauge - 25 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e25\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1200\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1.28\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU06\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC06\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866085439,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_3c348728-4a6c-4363-80e2-d0803f633555.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-12-gauge-37-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 12 Gauge - 37 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e37\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1450\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1.46\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU06\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC07\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866118207,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_e3ef14f8-15c0-4f22-a011-387accb1dff2.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-12-gauge-4-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 12 Gauge - 4 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e4\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e295\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.73\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866150975,"sku":"","price":2.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_02504524-46e5-4dc4-9f85-df80f8f98690.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-12-gauge-5-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 12 Gauge - 5 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e5\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e325\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.76\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866183743,"sku":"","price":3.57,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_ac9f2f3d-9898-4102-910c-e32c8bb29ea7.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-12-gauge-7-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 12 Gauge - 7 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e400\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.83\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866216511,"sku":"","price":3.84,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_f68c0e61-7f81-4644-b6d7-8e2ffbaef2c9.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-12-gauge-9-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 12 Gauge - 9 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e9\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e460\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.90\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866249279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_60b03b07-2c8a-4633-800a-7a8105a786d3.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-14-gauge-10-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 14 Gauge - 10 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e410\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.88\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866282047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_9500a2f4-71d6-4877-8906-dd7155487bd8.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-14-gauge-12-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 14 Gauge - 12 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e460\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.91\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866314815,"sku":"","price":3.59,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_fe7d5a1a-dafd-4dca-b50a-d51f33494e34.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-14-gauge-15-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 14 Gauge - 15 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e15\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e550\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.95\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866347583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_0dfdaaa4-e9a3-4f10-8909-d86a43fb08cc.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-14-gauge-19-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 14 Gauge - 19 Conductor - 600 Volt UL Type MC","description":"\u003cmeta charset=\"utf-8\"\u003e Untitled Document\u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e660\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.03\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e416MC05\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\n        ICEA Method 1, Table E-2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\n        \u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866413119,"sku":"","price":5.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_3026aa85-b5c6-4e99-94b8-b36c03e0ec59.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-14-gauge-2-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 14 Gauge - 2 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e176\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.61\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU02\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC02\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866445887,"sku":"","price":1.49,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_41fb73ad-e96e-4ff4-af39-d396c3e3cb21.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-14-gauge-25-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 14 Gauge - 25 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e25\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e877\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e1.17\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU05\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC06\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866478655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_122943ec-f0ac-464c-9e4a-05808b133c40.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-14-gauge-3-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 14 Gauge - 3 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e3\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e185\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.63\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU02\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866511423,"sku":"","price":1.99,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_e8e9eea9-5dc2-4655-ae67-7e4badfb69f7.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-14-gauge-37-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 14 Gauge - 37 Conductor - 600 Volt UL Type MC","description":"\u003cmeta charset=\"utf-8\"\u003e Untitled Document\u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e37\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1200\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.32\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e424CU06\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e416MC06\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\n        ICEA Method 1, Table E-2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\n        \u003c\/trstyle\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866544191,"sku":"","price":5.29,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_e4663761-7926-4d3a-b541-c931c4af2ca8.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-14-gauge-4-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 14 Gauge - 4 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e4\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e210\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.67\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866576959,"sku":"","price":2.79,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_1354636d-61fb-43c0-85d1-0e4a9d10b806.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-14-gauge-5-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 14 Gauge - 5 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e5\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e270\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.71\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866609727,"sku":"","price":1.88,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_1aa3f40e-91d2-493f-a019-1d83ca4c7021.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-14-gauge-7-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 14 Gauge - 7 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e320\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.76\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU02\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC03\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866642495,"sku":"","price":2.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_f9a12ee4-7a47-46a8-9c18-1d092e7fe9c2.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-14-gauge-9-conductor-600-volt-ul-type-mc","title":"Interlocked Armor Control Cable - 14 Gauge - 9 Conductor - 600 Volt UL Type MC","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003ctrstyle\u003e\r\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr style=\"background-color: #495682;\"\u003e\r\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eSize (AWG or kcmil):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Conductors\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e9\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e388\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter (Inches):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e0.84\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eInsulation Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eJacket Thickness (Mils):\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eNo. of Strands:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eClass 1 Div.2 Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e424CU04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cstrong\u003eRain Tight Connector No.:\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e416MC04\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003c\/trstyle\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866675263,"sku":"","price":2.8,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_cae66784-a7dd-4599-adbb-639a6436371a.jpg?v=1571727222"},{"product_id":"interlocked-armor-control-cable-600-volt-ul-type-mc-xlp-vw-1-xhhw-2-aluminum-armor-copper-conductors","title":"Interlocked Armor Control Cable 600 Volt UL Type MC XLP VW-1 XHHW-2 Aluminum Armor Copper Conductors","description":"\r\n    \r\n        \u003cmeta charset=\"utf-8\"\u003e\r\n        \u003ctitle\u003eUntitled Document\u003c\/title\u003e\r\n    \r\n    \r\n        \u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\r\n        \u003cul\u003e\r\n            \u003cli\u003eInterlocked Armor - Control Cable\u003c\/li\u003e\r\n            \u003cli\u003e600 Volt UL Type MC, CT Use, 90°C\u003c\/li\u003e\r\n            \u003cli\u003eXLP VW-1 XHHW-2 Insulation\u003c\/li\u003e\r\n            \u003cli\u003eAluminum Armor\u003c\/li\u003e\r\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\r\n        \u003c\/ul\u003e\r\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\r\n        For use in harsh environments where maximum conductor protection is required. Used for power, control and lighting circuits in a broad range of commercial and industrial pulp and paper, mining, and petroleum applications. Approved for use in wet or dry locations at 90°C, for installation indoors or outdoors, aerially, in conduits, ducts, cable trays or direct burial in circuits not exceeding 600 volts. May be used in NEC Class I and II, Division 2 and Class III, Division 1 and 2 hazardous locations. UL approved for use at 90°C for continuous operation, 130°C for emergency overload conditions, and 250°C for short circuit conditions. Aluminum interlocked armor cable is recommended as an economical alternative to wire in conduit systems.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 (compressed) or ASTM B-496 (compact).\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\r\n        Cross-linked polyethylene (XLP) per UL Standard 44 for Type XHHW-2, VW-1 conductors.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8 sized in accordance with UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e\u003cbr\u003e\r\n        Aluminum interlocked tape armor per UL Standard 1569. Also available in galvanized steel armor.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e\r\n        Black sunlight-resistant PVC per UL Standard 1569.\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\r\n        UL 1581 70,000 BTU\/hr flame test\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003cbr\u003e\r\n        ICEA Method 1, Table E-2\u003c\/p\u003e\r\n        \u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cbr\u003e\r\n        Explosion Proof, Class 1 Division 2: 424CU series – aluminum exterior components, nickel-plated brass interior components\r\n        Rain Tight: 416MC series – all nickel-plated brass\u003c\/p\u003e\r\n        \u003ctable width=\"100%\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center; font-size: 0.9em;\"\u003e\r\n            \u003ctbody\u003e\r\n                \u003ctr\u003e\r\n                    \u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eSize (AWG \u003cbr\u003e\r\n                    or kcmil)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eNo. of\u003cbr\u003e\r\n                    Conductors\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eNet \u003cbr\u003e\r\n                    Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd style=\"border: 1px solid #ffffff; width: 10px; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eOverall Diameter\u003cbr\u003e\r\n                    (Inches)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd style=\"border: 1px solid #ffffff; width: 10px; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eInsulation\u003cbr\u003e\r\n                    Thickness\r\n                    (Mils)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eJacket\u003cbr\u003e\r\n                    Thickness\u003cbr\u003e\r\n                     (Mils)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eNo. of\u003cbr\u003e\r\n                    Strands\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n                    \u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cspan style=\"color: #ffffff;\"\u003e\u003cstrong\u003eGround \u003cbr\u003e\r\n                    Wire Size\u003cbr\u003e\r\n                    AWG\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd style=\"border: 1px solid #ffffff; background-color: #495682;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: #ffffff;\"\u003eProduct \u003cbr\u003e\r\n                    Code\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-14-gauge-2-conductor\" style=\"color: #0101ff;\"\u003e14 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                    \u003ctd\u003e176\u003c\/td\u003e\r\n                    \u003ctd\u003e0.61\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01402\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-14-gauge-3-conductor\" style=\"color: #0101ff;\"\u003e14 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e3\u003c\/td\u003e\r\n                    \u003ctd\u003e185\u003c\/td\u003e\r\n                    \u003ctd\u003e0.63\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01403\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-14-gauge-4-conductor\" style=\"color: #0101ff;\"\u003e14 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e4\u003c\/td\u003e\r\n                    \u003ctd\u003e210\u003c\/td\u003e\r\n                    \u003ctd\u003e0.67\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01404\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-14-gauge-5-conductor\" style=\"color: #0101ff;\"\u003e14 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e5\u003c\/td\u003e\r\n                    \u003ctd\u003e270\u003c\/td\u003e\r\n                    \u003ctd\u003e0.71\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01405\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-14-gauge-7-conductor\" style=\"color: #0101ff;\"\u003e14 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e320\u003c\/td\u003e\r\n                    \u003ctd\u003e0.76\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01407\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-14-gauge-9-conductor\" style=\"color: #0101ff;\"\u003e14 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e9\u003c\/td\u003e\r\n                    \u003ctd\u003e388\u003c\/td\u003e\r\n                    \u003ctd\u003e0.84\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01409\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-14-gauge-10-conductor\" style=\"color: #0101ff;\"\u003e14 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003e410\u003c\/td\u003e\r\n                    \u003ctd\u003e0.88\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01410\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-14-gauge-12-conductor\" style=\"color: #0101ff;\"\u003e14 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003e460\u003c\/td\u003e\r\n                    \u003ctd\u003e0.91\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01412\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-14-gauge-15-conductor\" style=\"color: #0101ff;\"\u003e14 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e15\u003c\/td\u003e\r\n                    \u003ctd\u003e550\u003c\/td\u003e\r\n                    \u003ctd\u003e0.95\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01415\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-14-gauge-19-conductor\" style=\"color: #0101ff;\"\u003e14 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e19\u003c\/td\u003e\r\n                    \u003ctd\u003e660\u003c\/td\u003e\r\n                    \u003ctd\u003e1.03\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01419\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-14-gauge-25-conductor\" style=\"color: #0101ff;\"\u003e14 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e25\u003c\/td\u003e\r\n                    \u003ctd\u003e877\u003c\/td\u003e\r\n                    \u003ctd\u003e1.17\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01425\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-14-gauge-37-conductor\" style=\"color: #0101ff;\"\u003e14 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e37\u003c\/td\u003e\r\n                    \u003ctd\u003e1200\u003c\/td\u003e\r\n                    \u003ctd\u003e1.32\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e14\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01437\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-12-gauge-02-conductor\" style=\"color: #0101ff;\"\u003e12 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                    \u003ctd\u003e185\u003c\/td\u003e\r\n                    \u003ctd\u003e0.65\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01202\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-12-gauge-03-conductor\" style=\"color: #0101ff;\"\u003e12 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e3\u003c\/td\u003e\r\n                    \u003ctd\u003e215\u003c\/td\u003e\r\n                    \u003ctd\u003e0.69\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01203\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-12-gauge-4-conductor\" style=\"color: #0101ff;\"\u003e12 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e4\u003c\/td\u003e\r\n                    \u003ctd\u003e295\u003c\/td\u003e\r\n                    \u003ctd\u003e0.73\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01204\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-12-gauge-5-conductor\" style=\"color: #0101ff;\"\u003e12 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e5\u003c\/td\u003e\r\n                    \u003ctd\u003e325\u003c\/td\u003e\r\n                    \u003ctd\u003e0.76\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01205\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-12-gauge-7-conductor\" style=\"color: #0101ff;\"\u003e12 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e400\u003c\/td\u003e\r\n                    \u003ctd\u003e0.83\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01207 \u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-12-gauge-9-conductor\" style=\"color: #0101ff;\"\u003e12 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e9\u003c\/td\u003e\r\n                    \u003ctd\u003e460\u003c\/td\u003e\r\n                    \u003ctd\u003e0.90\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01209\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-12-gauge-10-conductor\" style=\"color: #0101ff;\"\u003e12 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003e560\u003c\/td\u003e\r\n                    \u003ctd\u003e0.95\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01210\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-12-gauge-12-conductor\" style=\"color: #0101ff;\"\u003e12 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003e615\u003c\/td\u003e\r\n                    \u003ctd\u003e1.00\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01212\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-12-gauge-15-conductor\" style=\"color: #0101ff;\"\u003e12 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e15\u003c\/td\u003e\r\n                    \u003ctd\u003e680\u003c\/td\u003e\r\n                    \u003ctd\u003e1.04\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01215\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-12-gauge-19-conductor\" style=\"color: #0101ff;\"\u003e12 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e19\u003c\/td\u003e\r\n                    \u003ctd\u003e900\u003c\/td\u003e\r\n                    \u003ctd\u003e1.16\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01219\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-12-gauge-25-conductor\" style=\"color: #0101ff;\"\u003e12 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e25\u003c\/td\u003e\r\n                    \u003ctd\u003e1200\u003c\/td\u003e\r\n                    \u003ctd\u003e1.28\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01225\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-12-gauge-37-conductor\" style=\"color: #0101ff;\"\u003e12 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e37\u003c\/td\u003e\r\n                    \u003ctd\u003e1450\u003c\/td\u003e\r\n                    \u003ctd\u003e1.46\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01237\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-10-gauge-2-conductor\" style=\"color: #0101ff;\"\u003e10 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e2\u003c\/td\u003e\r\n                    \u003ctd\u003e230\u003c\/td\u003e\r\n                    \u003ctd\u003e0.70\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01002\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-10-gauge-3-conductor\" style=\"color: #0101ff;\"\u003e10 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e3\u003c\/td\u003e\r\n                    \u003ctd\u003e300\u003c\/td\u003e\r\n                    \u003ctd\u003e0.72\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01003\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-10-gauge-4-conductor\" style=\"color: #0101ff;\"\u003e10 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e4\u003c\/td\u003e\r\n                    \u003ctd\u003e345\u003c\/td\u003e\r\n                    \u003ctd\u003e0.79\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01004\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-10-gauge-5-conductor\" style=\"color: #0101ff;\"\u003e10 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e5\u003c\/td\u003e\r\n                    \u003ctd\u003e450\u003c\/td\u003e\r\n                    \u003ctd\u003e0.83\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01005\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-10-gauge-7-conductor\" style=\"color: #0101ff;\"\u003e10 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e560\u003c\/td\u003e\r\n                    \u003ctd\u003e0.89\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01007\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-10-gauge-9-conductor\" style=\"color: #0101ff;\"\u003e10 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e9\u003c\/td\u003e\r\n                    \u003ctd\u003e640\u003c\/td\u003e\r\n                    \u003ctd\u003e0.99\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01009\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-10-gauge-12-conductor\" style=\"color: #0101ff;\"\u003e10 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e12\u003c\/td\u003e\r\n                    \u003ctd\u003e880\u003c\/td\u003e\r\n                    \u003ctd\u003e1.13\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01012\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-10-gauge-15-conductor\" style=\"color: #0101ff;\"\u003e10 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e15\u003c\/td\u003e\r\n                    \u003ctd\u003e965\u003c\/td\u003e\r\n                    \u003ctd\u003e1.18\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01015\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-10-gauge-19-conductor\" style=\"color: #0101ff;\"\u003e10 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e19\u003c\/td\u003e\r\n                    \u003ctd\u003e1300\u003c\/td\u003e\r\n                    \u003ctd\u003e1.27\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01019\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-10-gauge-25-conductor\" style=\"color: #0101ff;\"\u003e10 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e25\u003c\/td\u003e\r\n                    \u003ctd\u003e1500\u003c\/td\u003e\r\n                    \u003ctd\u003e1.42\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01025\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\r\n                    \u003ctd\u003e\u003cspan style=\"color: #0101ff;\"\u003e\u003ca href=\"\/products\/interlocked-armor-cable\/interlocked-armor-control-cable-10-gauge-37-conductor\" style=\"color: #0101ff;\"\u003e10 Gauge\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\r\n                    \u003ctd\u003e37\u003c\/td\u003e\r\n                    \u003ctd\u003e2450\u003c\/td\u003e\r\n                    \u003ctd\u003e1.64\u003c\/td\u003e\r\n                    \u003ctd\u003e30\u003c\/td\u003e\r\n                    \u003ctd\u003e50\u003c\/td\u003e\r\n                    \u003ctd\u003e7\u003c\/td\u003e\r\n                    \u003ctd\u003e10\u003c\/td\u003e\r\n                    \u003ctd\u003eHW300 01037\u003c\/td\u003e\r\n                \u003c\/tr\u003e\r\n            \u003c\/tbody\u003e\r\n        \u003c\/table\u003e\r\n    \r\n","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7151866708031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW300-01402-lg_cc3bdfd6-09a5-4c9b-93fb-50220565d29c.jpg?v=1571727223"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/interlocked-armor-control-cable-600-volt-ul-type-mc-xlp-vw-1-xhhw-2-aluminum-armor-copper-conductors.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}