{"title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors","description":"","products":[{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors","description":"\u003cmeta charset=\"utf-8\"\u003e\n\u003cp\u003eThe HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual And Overall Shield TFN Insulation PVC Jacket Copper Conductors cable employs 7-strand, Class B, soft bare annealed copper conductors.  The annealed copper products used in this cable offers increased flexibility compared to standard copper.  The cable meets ASTM specifications B3 for annealed cable, and B8 for concentric-lay-stranded cables.  The HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual And Overall Shield TFN Insulation PVC Jacket Copper Conductors cable is insulated with flame-retardant polyvinyl chloride (PVC) insulation.  The insulated conductors are shielded with an aluminum-polymer tape, providing 100% coverage with a flexible 7-strand tinned copper drain wire.  A PVC jacket serves as the outer layer of the cable.  The cable’s construction offers excellent resistance to flame, sunlight, and chemicals.\u003c\/p\u003e\n\u003cp\u003eThe HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual And Overall Shield TFN Insulation PVC Jacket Copper Conductors cable is used in instrumentation and process control applications where protection from electrostatic interference is required.  UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts.  The cable may be used in NEC Class 1, Division 2 hazardous locations.\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. Size (AWG)\u003c\/td\u003e\n\u003ctd\u003eNo. of Pairs\u003c\/td\u003e\n\u003ctd\u003eNet weight Lbs\/Mft\u003c\/td\u003e\n\u003ctd\u003eCatalog Number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--1\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--1\"\u003eHW106 01802\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--1\"\u003eHW10601802\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--2\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e146\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--2\"\u003eHW106 01804\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--2\"\u003eHW10601804\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--3\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e279\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--3\"\u003eHW106 01808\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--3\"\u003eHW10601808\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--3\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--4\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e391\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--4\"\u003eHW106 01812\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--4\"\u003eHW10601812\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--4\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--6\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e494\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--5\"\u003eHW106 01824\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--5\"\u003eHW10601824\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--6\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e752\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--6\"\u003eHW106 01824\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--6\"\u003eHW10601824\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--7\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e1053\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--7\"\u003eHW106 01836\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--7\"\u003eHW10601836\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--7\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--8\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e1300\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--8\"\u003eHW106 01850\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--8\"\u003eHW10601850\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--9\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e105\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--9\"\u003eHW106 01602\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--9\"\u003eHW10601602\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield--9\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-10\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-10\"\u003eHW106 01603\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-10\"\u003eHW10601603\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-10\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-11\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e207\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-11\"\u003eHW106 01604\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-11\"\u003eHW10601604\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-11\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-12\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-12\"\u003eHW106 01606\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-12\"\u003eHW10601606\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-12\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-13\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e349\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-13\"\u003eHW106 01608\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-13\"\u003eHW10601608\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-13\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-14\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e528\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-14\"\u003eHW106 01612\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-14\"\u003eHW10601612\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-14\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-15\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e623\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-15\"\u003eHW106 01616\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-15\"\u003eHW10601616\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-15\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-16\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e944\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-16\"\u003eHW106 01624\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-16\"\u003eHW10601624\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-16\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-17\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e1331\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-17\"\u003eHW106 01636\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-17\"\u003eHW10601636\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-17\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-18\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e1731\u003c\/td\u003e\n\u003ctd\u003e\n\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-18\"\u003eHW106 01650\u003c\/a\u003e \/\u003cbr\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-instrumentation-cable\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-18\"\u003eHW10601650\u003c\/a\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/instrumentation-cable-and-pltc\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-18\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150396538943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-16-awg-12-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 12 Pairs","description":"\n    \n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 12 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 12 Pairs -HW106 01612 Click for a free quote.16 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"16 AWG - 12 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01612\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.11\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e528\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150396571711,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_824e6026-e9fe-4b4f-90b0-0f14c5bd6610.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-16-awg-16-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 16 Pairs","description":"\n    \n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 16 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 16 Pairs -\tHW106 01616 Click for a free quote.16 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"16 AWG - 16 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01616\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e623\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150397587519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_4b9f0f49-4dbe-4eeb-9a04-4ef2835f010e.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-16-awg-2-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 2 Pairs","description":"\n    \n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 2 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 2 Pairs -HW106 01602 Click for a free quote.16 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"16 AWG - 2 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01602\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.48\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e105\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150399127615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_f5336bd8-626a-4f63-88ab-93f3f2094509.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-16-awg-24-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 24 Pairs","description":"\n    \n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 24 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 24 Pairs -\tHW106 01624 Click for a free quote.16 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"16 AWG - 24 Pair,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01624\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e944\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150399881279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_d2f2fa91-7fec-4c38-bf62-6b61fe729fa4.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-16-awg-3-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 3 Pairs","description":"\n    \n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 3 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 3 Pairs -\tHW106 01603 Click for a free quote.16 AWGIndividual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 4 Pairs -\tHW106 01603 Click for a free quote.16 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"16 AWG - 3 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01603\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.56\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e136\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150399914047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_ea91c3ec-ffb5-4255-b22e-04b59f2b4b8c.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-16-awg-36-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 36 Pairs","description":"\n    \n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 36 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 36 Pairs -\tHW106 01636 Click for a free quote.16 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"16 AWG - 36 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01636\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e36\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.59\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1331\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150399946815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_030891dd-cf0c-4930-b363-9e78e2df4680.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-16-awg-4-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 4 Pairs","description":"\n    \n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 4 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 4 Pairs -\tHW106 01604 Click for a free quote.16 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"16 AWG - 4 Pairs ,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01604\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.63\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e207\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150399979583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_ae6dbca3-2e0d-4a75-aa9d-59a5517078de.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-16-awg-50-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 50 Pairs","description":"\n    \n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 50 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 50 Pairs -\tHW106 01650 Click for a free quote.16 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"16 AWG - 50 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01650\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e110\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.96\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1731\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150400045119,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_29abd650-4088-4074-a410-ae760dda6b77.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-16-awg-6-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 6 Pairs","description":"\n    \n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 6 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 6 Pairs - HW106 01606 Click for a free quote.16 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"16 AWG - 6 Pairs.HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01606\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.77\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e257\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150400077887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_9159cf7b-4e86-4d0f-a1d8-dc6fee415457.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-16-awg-8-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 8 Pairs","description":"\n    \n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 8 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 16 AWG - 8 Pairs - HW106 01608 Click for a free quote.16 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"16 AWG - 8 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01608\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.81\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e349\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150400110655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_4fe4790e-94d8-4db7-b14e-6016a0cea348.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-18-awg-12-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 12 Pairs","description":"\n    \n        \u003cmeta charset=\"utf-8\"\u003e\n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 12 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 12 Pairs -HW106 01812 Click for a free quote.18 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"18 AWG - 12 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01812\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.85\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e391\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150400143423,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_cf2e9c14-a758-49c4-8e9b-6113a5000b86.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-18-awg-16-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 16 Pairs","description":"\n    \n        \u003cmeta charset=\"utf-8\"\u003e\n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 16 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 16 Pairs -HW106 01816 Click for a free quote.18 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"18 AWG - 16 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01816\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.05\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e494\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150400176191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_a90ddea4-dc4c-4394-80fc-fd428bb1e8e6.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-18-awg-2-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 2 Pairs","description":"\n    \n        \u003cmeta charset=\"utf-8\"\u003e\n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 2 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"18 AWG - 2 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 2 Pairs -HW106 01802 Click for a free quote.18 AWG\"\u003e\n    \n    \n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01802\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.44\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e82\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150400208959,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_2ce24e58-db82-4803-9edf-1b628d5b0b31.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-18-awg-24-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 24 Pairs","description":"\n    \n        \u003cmeta charset=\"utf-8\"\u003e\n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 24 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 24 Pairs -HW106 01824 Click for a free quote.18 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"18 AWG - 24 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01824\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e752\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150400241727,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_86ffd7d6-7b35-448a-9345-0a9a07e06e0f.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-18-awg-36-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 36 Pairs","description":"\n    \n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 36 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 36 Pairs -HW106 01836 Click for a free quote.18 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"18 AWG - 36 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        v\n        \u003cmeta charset=\"utf-8\"\u003e\n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 36 Pairs\u003c\/title\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01836\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e36\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.37\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1053\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150400274495,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_9ecb524e-338c-414a-ba51-0ab850c9cdba.jpg?v=1571727102"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-18-awg-4-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 4 Pairs","description":"\n    \n        \u003cmeta charset=\"utf-8\"\u003e\n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 4 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 4 Pairs -HW106 01804 Click for a free quote.18 AWG \"\u003e\n        \u003cmeta name=\"Keywords\" content=\"18 AWG - 4 Pairs ,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01804\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.52\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e146\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150400307263,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_5d0f0487-9edf-45ac-8a37-bdc4f673331d.jpg?v=1571727103"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-18-awg-50-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 50 Pairs","description":"\n    \n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 50 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 50 Pairs -HW106 01850  Click for a free quote.18 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"18 AWG - 50 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\"\u003e\n    \n    \n        \u003cbr\u003e\n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01850\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e1.71\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e1300\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150400340031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_3a46095f-ce5e-4296-b0c3-e36a5d543617.jpg?v=1571727103"},{"product_id":"hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors-18-awg-8-pairs","title":"HW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 8 Pairs","description":"\n    \n        \u003cmeta charset=\"utf-8\"\u003e\n        \u003ctitle\u003eHW106 Instrumentation Cable 600 Volt UL Type TC, 90°C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 8 Pairs\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of  HW106 Instrumentation Cable 600 Volt UL Type TC, 90\u0026amp;deg;C Multiple Pairs Individual and Overall Shield TFN Insulation PVC Jacket Copper Conductors - 18 AWG - 4 Pairs -HW106 01808 Click for a free quote.18 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"\n        18 AWG - 4 Pairs,HW106 Cable, HW106 Wire, Instrumentation Cable Pice, Instrumentation Cable Quote, HW106 Cable Price, HW106 Cable Quote, Instrumentation Cable 600 Volt UL Price, Instrumentation Cable 600 Volt UL Quote, Tray Cable, Type TC Price, PVC Jacket cable, PVC Jacket Wire, PVC Jacket Copper Conductors Price, PVC Jacket Copper Conductors Quote, TFN Insulation Cable , TFN Insulation Wire, TFN Insulation Price, TFN Insulation Quote, Multiple Pairs Individual and Overall Shield Cable, HW106 Instrumentation Cable 600 Volt Price, HW106 Instrumentation Cable 600 Volt Quote\n        \"\u003e\n    \n    \n        \u003ctrstyle\u003e\n        \u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n            \u003ctbody\u003e\n                \u003ctr style=\"background-color: #495682;\"\u003e\n                    \u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eCatalog Number\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHW106 01808\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eSize AWG\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #f2f2f2;\"\u003eNo. of Pairs\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003ePVC Insulation Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eNylon Jacket Thickness Mils\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eOverall Jacket Thickness Mils\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #f2f2f2;\"\u003e\n                    \u003ctd\u003e\u003cstrong\u003eOverall Diameter Inch\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0.71\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr style=\"background-color: #d0d8e5;\"\u003e\n                    \u003ctd\u003e\n\u003cstrong style=\"background-color: #d0d8e5;\"\u003e\u003cstrong\u003eNet Weight Lbs\/Mft\u003c\/strong\u003e\u003c\/strong\u003e\u003cbr\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e279\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003cbr\u003e\n        \u003cp\u003eSpecifications:\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eHW106\u003c\/li\u003e\n            \u003cli\u003eInstrumentation Cable\u003c\/li\u003e\n            \u003cli\u003e600 Volt UL Type TC, 90°C\u003c\/li\u003e\n            \u003cli\u003eMultiple Pairs\u003c\/li\u003e\n            \u003cli\u003eIndividual and Overall Shield\u003c\/li\u003e\n            \u003cli\u003eTFN Insulation\u003c\/li\u003e\n            \u003cli\u003ePVC Jacket\u003c\/li\u003e\n            \u003cli\u003eCopper Conductors\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e\n        For use in instrumentation and process control applications where protection from electrostatic interference is required. UL listed as Type PLTC and ITC and approved for installation indoors or outdoors, aerially, in conduits, ducts and cable trays in circuits not exceeding 600 volts. May be used in NEC Class 1, Division 2 hazardous locations.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e\n        7-strand soft bare annealed copper per ASTM B-3, Class B stranding per ASTM B-8.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e\n        Flame-retardant PVC per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Jacket:\u003c\/strong\u003e\u003cbr\u003e\n        Clear nylon per UL Standard 62 for Type TFN wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eIndividual Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOverall Shield:\u003c\/strong\u003e\u003cbr\u003e\n        Aluminum-polymer tape providing 100% coverage with a flexible 7-strand tinned copper drain wire. Jacket: Sunlight-resistant PVC per UL Standard 1277. A ripcord is applied longitudinally under the jacket to facilitate stripping.\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlame Tests:\u003c\/strong\u003e\u003cbr\u003e\n        UL 1581 70,000 BTU\/hr flame test\n        \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eColor Code:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eICEA Method 9: black and white pairs with printed number\u003c\/li\u003e\n            \u003cli\u003eAvailable upon request: black and red pairs with printed number\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003cp\u003e\u003cstrong\u003eAdditional Standards:\u003c\/strong\u003e\u003c\/p\u003e\n        \u003cul\u003e\n            \u003cli\u003eNEC Type TC for Class I Division 2 areas per Articles 336, 392 and 501, and for Class 1 circuits per NEC Article 725\u003c\/li\u003e\n            \u003cli\u003eNEC Type NPFL for Non Power Limited Fire Protective Signaling circuits per NEC Article 760\u003c\/li\u003e\n        \u003c\/ul\u003e\n        \u003c\/trstyle\u003e\n    \n","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150400405567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW106-01802-lg_c309d4e0-491e-4032-a3a1-594d2ef59eac.jpg?v=1571727103"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/hw106-instrumentation-cable-600-volt-ul-type-tc-90-c-multiple-pairs-individual-and-overall-shield-tfn-insulation-pvc-jacket-copper-conductors.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}