{"title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation","description":"","products":[{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta charset=\"utf-8\"\u003eUntitled Document\n\u003cp\u003eThe HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin-plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eThe HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation cable is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\" style=\"color: #ffffff;\" align=\"center\"\u003ePower and Control Cable Color Legend :\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor #\u003c\/td\u003e\n\u003ctd\u003eColor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003cdiv\u003e\u003c\/div\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize AWG\u003c\/td\u003e\n\u003ctd\u003eSize (mm2)\u003c\/td\u003e\n\u003ctd\u003eWeight (lbs.\/1000ft.)\u003c\/td\u003e\n\u003ctd\u003eProduct Code\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e129\u003c\/td\u003e\n\u003ctd\u003eHW290 01402 \/ HW29001402\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-2-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003ctd\u003eHW290 01403 \/ HW29001403\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-3-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e174\u003c\/td\u003e\n\u003ctd\u003eHW290 01404 \/ HW29001404\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-4-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e206\u003c\/td\u003e\n\u003ctd\u003eHW290 01405 \/ HW29001405\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-5-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e249\u003c\/td\u003e\n\u003ctd\u003eHW290 01407 \/ HW29001407\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-7-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e289\u003c\/td\u003e\n\u003ctd\u003eHW290 01409 \/ HW29001409\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/o-multi-conductor-type-p-control-cable\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-9-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e426\u003c\/td\u003e\n\u003ctd\u003eHW290 01412 \/ HW29001412\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-12-condu\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e677\u003c\/td\u003e\n\u003ctd\u003eHW290 01419 \/ HW29001419\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-19-condu\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e1138\u003c\/td\u003e\n\u003ctd\u003eHW290 01437 \/ HW29001437\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-37-condu\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003ctd\u003e163\u003c\/td\u003e\n\u003ctd\u003eHW290 01202 \/ HW29001202\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-2-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003ctd\u003eHW290 01203 \/ HW29001203\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-3-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003ctd\u003e227\u003c\/td\u003e\n\u003ctd\u003eHW290 01204 \/ HW29001204\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-4-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003ctd\u003eHW290 01205 \/ HW29001205\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-5-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003ctd\u003e374\u003c\/td\u003e\n\u003ctd\u003eHW290 01207 \/ HW29001207\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-7-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003ctd\u003e435\u003c\/td\u003e\n\u003ctd\u003eHW290 01209 \/ HW29001209\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-9-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003ctd\u003e576\u003c\/td\u003e\n\u003ctd\u003eHW290 01212 \/ HW29001212\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-12-condu\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003ctd\u003e1007\u003c\/td\u003e\n\u003ctd\u003eHW290 01219 \/ \u003cspan style=\"font-size: 14.4px; text-align: center; background-color: #f2f2f2;\"\u003eHW29001219\u003c\/span\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-19-condu\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003ctd\u003e1739\u003c\/td\u003e\n\u003ctd\u003eHW290 01237 \/ HW29001237\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-37-condu\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e204\u003c\/td\u003e\n\u003ctd\u003eHW290 01002 \/ HW29001002\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-10-awg-2-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003ctd\u003eHW290 01003 \/ HW29001003\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-10-awg-3-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e335\u003c\/td\u003e\n\u003ctd\u003eHW290 01004 \/ HW29001004\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-10-awg-4-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e397\u003c\/td\u003e\n\u003ctd\u003eHW290 01005 \/ HW29001005\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-10-awg-5-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e488\u003c\/td\u003e\n\u003ctd\u003eHW290 01007 \/ HW29001007\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-10-awg-7-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e575\u003c\/td\u003e\n\u003ctd\u003eHW290 01009 \/ HW29001009\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-10-awg-9-conduc\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e980\u003c\/td\u003e\n\u003ctd\u003eHW290 01012 \/ HW29001012\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"\/products\/crush-and-impact-resistant-arctic-grade\/hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-10-awg-12-condu\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150369898559,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-10-awg-12-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 10 AWG - 12 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 10 AWG - 12 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.\"\u003e\u003cmeta name=\"Keywords\" content=\"10 AWG - 12 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e980\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.092\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctrstyle style=\"box-sizing: border-box; -webkit-tap-highlight-color: transparent; color: #475054; font-family: lato, sans-serif; font-size: 16px; line-height: 22.4px;\"\u003e \u003c\/trstyle\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150369964095,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_dbf5101d-60f3-483c-9d90-14d8c94f0520.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-10-awg-3-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 10 AWG - 3 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 10 AWG - 3 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity. \"\u003e\u003cmeta name=\"Keywords\" content=\"10 AWG - 3 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.685\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150369996863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_f5b74904-62cb-4cc1-a3f1-227df439e061.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-10-awg-5-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 10 AWG - 5 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 10 AWG - 5 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.\"\u003e\u003cmeta name=\"Keywords\" content=\"10 AWG - 5 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e397\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150371504191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_96f1d07d-e649-420c-8bfb-e0b304abdc68.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-10-awg-9-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 10 AWG - 9 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 10 AWG - 9 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  \"\u003e\u003cmeta name=\"Keywords\" content=\"10 AWG - 9 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e575\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372421695,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_b8e5c900-9c76-4c4d-8d86-ec9e5f222c78.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-12-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 12 AWG - 12 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 12 AWG - 12 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity. \"\u003e\u003cmeta name=\"Keywords\" content=\"12 AWG - 12 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 012012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.935\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e576\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.294\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372454463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_5c2c26fc-554d-46ed-9320-ebb5b90a5993.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-19-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 12 AWG - 19 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 12 AWG - 19 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  \"\u003e\u003cmeta name=\"Keywords\" content=\"12 AWG - 19 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 012019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.294\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372487231,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_b1186eea-026b-4b88-aafe-8a7c9d3d6bc3.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-2-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 12 AWG - 2 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 12 AWG - 2 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity. \"\u003e\u003cmeta name=\"Keywords\" content=\"12 AWG - 2 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 012002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.539\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e163\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372519999,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_1443ccc2-9385-4ca4-a93d-818b6d4b33f3.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-3-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 12 AWG - 3 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 12 AWG - 3 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity. \"\u003e\u003cmeta name=\"Keywords\" content=\"12 AWG - 3 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 012003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372552767,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_c21999fa-b477-41b9-b771-5a675a73affd.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-37-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 12 AWG - 37 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 12 AWG - 37 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.\"\u003e\u003cmeta name=\"Keywords\" content=\"12 AWG - 37 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 012037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1739\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372585535,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_47879b94-6300-440d-952f-a6a6ce043d1d.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-4-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 12 AWG - 4 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 12 AWG - 4 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity. \"\u003e\u003cmeta name=\"Keywords\" content=\"12 AWG - 4 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 012004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.685\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e227\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.198\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372618303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_2d3bdcd7-47ba-4884-9462-a59156a19b65.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-5-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 12 AWG - 5 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 12 AWG - 5 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.\"\u003e\u003cmeta name=\"Keywords\" content=\"12 AWG - 5 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 012005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.198\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372651071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_0a965b69-2840-4e8b-956e-ef53ed5acec3.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-7-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 12 AWG - 7 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 12 AWG - 7 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  \"\u003e\u003cmeta name=\"Keywords\" content=\"12 AWG - 7 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 012007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.865\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e374\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.198\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372683839,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_a8b923a4-6bc5-4a22-b364-7a61ccce8f37.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-12-awg-9-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 12 AWG - 9 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 12 AWG - 9 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.\"\u003e\u003cmeta name=\"Keywords\" content=\"12 AWG - 9 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 012009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e435\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.198\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372716607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_25d00134-40c4-496d-9128-fc9f62eedf28.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-12-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 14 AWG - 12 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 14 AWG - 12 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity. \"\u003e\u003cmeta name=\"Keywords\" content=\"14 AWG - 12 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 014012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.851\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e426\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372749375,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_00317591-d79c-4fed-be44-1fca15f72bcf.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-19-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 14 AWG - 19 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 14 AWG - 19 Conductors\u003cmeta name=\"Description\" content=\"his cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity. \"\u003e\u003cmeta name=\"Keywords\" content=\"14 AWG - 19 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 014019\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e677\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372782143,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_2502646c-ec1c-4428-a88d-3555df8f08d9.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-2-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 14 AWG - 2 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 14 AWG - 2 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity. \"\u003e\u003cmeta name=\"Keywords\" content=\"14 AWG - 2 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.069\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372814911,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_58b8de8f-8f89-4482-a67d-b3b8b2c9f9bd.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-3-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 14 AWG - 3 Conductors","description":"HW 290 Listed CIR\u0026amp;reg; Control Cable Multi-Conductor + Ground 0.6\/1kV 90\u0026amp;deg;C Gexol\u0026amp;reg; Insulation - 14 AWG - 3 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.\"\u003e\u003cmeta name=\"Keywords\" content=\"14 AWG - 3 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.532\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.069\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372847679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_a8fbe59d-8675-4c4a-8d1b-bf3c5ee9452d.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-37-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 14 AWG - 37 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 14 AWG - 37 Conductors\u003cmeta name=\"Keywords\" content=\"14 AWG - 37 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  \"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 014037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.455\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1138\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e--\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372880447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_b516a917-5d7a-40ad-a5e0-26c415250998.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-4-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 14 AWG - 4 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 14 AWG - 4 Conductors\u003cmeta name=\"Keywords\" content=\"14 AWG - 4 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  \"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.572\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e174\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.072\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372913215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_3cad0e2f-bf82-48d4-809f-1a238f9fe929.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-5-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 14 AWG - 5 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 14 AWG - 5 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity. \"\u003e\u003cmeta name=\"Keywords\" content=\"14 AWG - 5 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.673\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e206\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.072\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372945983,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_6d633689-a70b-4bc4-a5bd-c941badd46f0.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-7-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 14 AWG - 7 Conductors","description":"HW 290 Listed CIR Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol Insulation - 14 AWG - 7 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  \"\u003e\u003cmeta name=\"Keywords\" content=\"14 AWG - 7 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01407\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.783\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e249\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.072\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150372978751,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_36d42c07-9d06-423a-9738-a7271b5d3be9.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol-insulation-14-awg-9-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 14 AWG - 9 Conductors","description":"\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01409\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.813\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e289\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e3.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.072\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eHW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/kV 90°C Gexol® Insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Description:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  The tin plating on the copper conductors enhances the wire’s lifespan by up to ten times that of a bare copper conductor.  The Gexol® insulation is a polyolefin material that is designed to protect the conductors from a long list of corrosive elements including fire, oil and vapors.  The insulation also protects the conductors from abrasion and sunlight.  The cable is capable of carrying an ampacity of up to 600V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis product is built to be able to withstand Earth’s most unforgiving environments.  The cable is approved for use in hazardous locations per Underwriters Laboratories standard 2225.  The Gexol insulation allows the cable to function in temperatures as low as -75°C and up to 90°C.  Its flexible mechanical properties make it a great alternative to Type MC.  The cable’s brittle point, which passes standards set forth by the American Society of Testing and Materials, allows the cable to function in arctic conditions.  The cable also meets Underwriters Laboratories requirements of standard 1309, deeming it acceptable for installation within marine vessels and offshore structures.  \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIn accordance with specifications set forth by Underwriters Laboratories, this product meets or exceeds standard 1277 and 2225.  These standards require the conductors to meet necessary criteria so they can be approved for use in hazardous locations. \u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER by Underwriters Laboratories.  This classification deems the cable safe for installation in cable tray as well as without cable tray.\u003c\/li\u003e\n\u003cli\u003eThis cable is rated TC-ER-HL by Underwriters Laboratories.  In accordance with 336.10(7) and 505.15(B)(1)(i) and as permitted in 501.10(A)(2) of the NEC, the cable is safe for use in exposed runs between utilization equipment and a cable tray.  It can also be used where the cable is protected against physical damage using channel, struts, or angles.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eConductors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThis product employs tinned copper conductors.  Copper is the one of the strongest conductive metals on Earth, second only to silver.  The conductors are soft annealed and are very flexible. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGround conductor\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe ground conductor supports the phase conductors to ensure steady conductivity for the life of the cable.  The ground wire is flexible stranded, soft annealed, and wears the same insulation as the phase conductors. \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eInsulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eEach individual conductor is coated in a Gexol® cross-linked polyolefin insulation.  The insulation is a durable material that protects the conductors from fire and other hazardous elements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eJacket\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"margin-left: 1in; text-indent: -0.5in;\"\u003e-\u003cspan style=\"font-stretch: normal; font-size: 7pt; font-family: 'times new roman';\"\u003e                \u003c\/span\u003eThe outer jacket is a flame retardant, black, thermoset material.  The outer jacket serves as the first line of defense against chemical and sunlight damage as well as corrosion caused by water vapors, oil, and abrasion.\u003c\/p\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150373011519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_b2450930-1eb6-4861-b97a-89d1bf9216c1.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir®-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol®-insulation-10-awg-2-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 10 AWG - 2 Conductors","description":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 10 AWG - 2 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity. \"\u003e\u003cmeta name=\"Keywords\" content=\"10 AWG - 2 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.582\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW290\u003c\/li\u003e\n\u003cli\u003eListed CIR® Control Cable*\u003c\/li\u003e\n\u003cli\u003eMulti-Conductor + Ground\u003c\/li\u003e\n\u003cli\u003e0.6\/1kV 90°C Gexol® Insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Designed and constructed to be a flexible alternative to Type MC cable where crush and impact protection in arctic conditions is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Gexol cross-linked flame retardant polyolefin, meets requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA 245. 600V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e Soft annealed, flexible stranded, insulated, tinned copper sized in accordance with UL 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset compound meeting UL 1309\/CSA 245 and IEEE 1580.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRatings \u0026amp; Approvals :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e90°C temperature rating\u003c\/li\u003e\n\u003cli\u003eUL Listed as Marine Shipboard Cable (E111461)\u003c\/li\u003e\n\u003cli\u003eUL Listed as Type TC-ER\u003c\/li\u003e\n\u003cli\u003eUL Listed as Type TC-ER-HL*\u003c\/li\u003e\n\u003cli\u003eAmerican Bureau of Shipping (ABS) (99-BT5905-X)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant – IEEE 1202\u003c\/li\u003e\n\u003cli\u003eSuitable for use in Class I, Div 2 \u0026amp; Zone 2 environments\u003c\/li\u003e\n\u003cli\u003eSuitable for use in Class I, Div 1 \u0026amp; Zone 1 environments*\u003c\/li\u003e\n\u003cli\u003e*Cables up to 1” in OD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with the requirements for TC-ER-HL* per UL 2225\u003c\/li\u003e\n\u003cli\u003eGas \u0026amp; vapor tight – impervious to water and air\u003c\/li\u003e\n\u003cli\u003eSmaller bend radius (up to 40% smaller) than Type MC\u003c\/li\u003e\n\u003cli\u003eReduced tray fill (up to 35% less) compared to Type MC\u003c\/li\u003e\n\u003cli\u003eConsiderably more flexible than Type MC\u003c\/li\u003e\n\u003cli\u003eBrittle point as per ASTM D 746-07 exceeds -65°C for Jacket and -75°C for Insulation\u003c\/li\u003e\n\u003cli\u003eExceeds CSA cold bend \/ cold impact (-40°C \/ -35°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150373044287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_0288815b-6ef8-45ed-b49b-cb0a24236734.jpg?v=1571727080"},{"product_id":"hw-290-listed-cir®-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol®-insulation-10-awg-4-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 10 AWG - 4 Conductors","description":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 10 AWG - 4 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  \"\u003e\u003cmeta name=\"Keywords\" content=\"10 AWG - 4 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW290\u003c\/li\u003e\n\u003cli\u003eListed CIR® Control Cable*\u003c\/li\u003e\n\u003cli\u003eMulti-Conductor + Ground\u003c\/li\u003e\n\u003cli\u003e0.6\/1kV 90°C Gexol® Insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Designed and constructed to be a flexible alternative to Type MC cable where crush and impact protection in arctic conditions is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Gexol cross-linked flame retardant polyolefin, meets requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA 245. 600V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e Soft annealed, flexible stranded, insulated, tinned copper sized in accordance with UL 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset compound meeting UL 1309\/CSA 245 and IEEE 1580.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRatings \u0026amp; Approvals :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e90°C temperature rating\u003c\/li\u003e\n\u003cli\u003eUL Listed as Marine Shipboard Cable (E111461)\u003c\/li\u003e\n\u003cli\u003eUL Listed as Type TC-ER\u003c\/li\u003e\n\u003cli\u003eUL Listed as Type TC-ER-HL*\u003c\/li\u003e\n\u003cli\u003eAmerican Bureau of Shipping (ABS) (99-BT5905-X)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant – IEEE 1202\u003c\/li\u003e\n\u003cli\u003eSuitable for use in Class I, Div 2 \u0026amp; Zone 2 environments\u003c\/li\u003e\n\u003cli\u003eSuitable for use in Class I, Div 1 \u0026amp; Zone 1 environments*\u003c\/li\u003e\n\u003cli\u003e*Cables up to 1” in OD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with the requirements for TC-ER-HL* per UL 2225\u003c\/li\u003e\n\u003cli\u003eGas \u0026amp; vapor tight – impervious to water and air\u003c\/li\u003e\n\u003cli\u003eSmaller bend radius (up to 40% smaller) than Type MC\u003c\/li\u003e\n\u003cli\u003eReduced tray fill (up to 35% less) compared to Type MC\u003c\/li\u003e\n\u003cli\u003eConsiderably more flexible than Type MC\u003c\/li\u003e\n\u003cli\u003eBrittle point as per ASTM D 746-07 exceeds -65°C for Jacket and -75°C for Insulation\u003c\/li\u003e\n\u003cli\u003eExceeds CSA cold bend \/ cold impact (-40°C \/ -35°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150373306431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_b0c70950-f7ce-4f06-a73b-64ac8a9bf6d9.jpg?v=1571727081"},{"product_id":"hw-290-listed-cir®-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol®-insulation-10-awg-7-conductors","title":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 10 AWG - 7 Conductors","description":"HW 290 Listed CIR® Control Cable Multi-Conductor + Ground 0.6\/1kV 90°C Gexol® Insulation - 10 AWG - 7 Conductors\u003cmeta name=\"Description\" content=\"This cable consists of multiple soft annealed flexible stranded conductors and a ground conductor that are all individually insulated.  The conductors are made of tinned copper, which offers extremely high electrical and mechanical integrity.  \"\u003e\u003cmeta name=\"Keywords\" content=\"10 AWG - 7 CONDUCTORS CONTROL CABLE, MULTI-CONDUCTOR, CIR CONTROL CABLE, GEXOL INSULATION, 0.6\/1KV 90°C GEXOL INSULATION, MULTI-CONDUCTOR + GROUND, HW 290 LISTED CIR CONTROL CABLE, HW 290 LISTED, HW 290\"\u003e\u003cbr\u003e \u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\u003cstrong\u003eTechnical Specifications:\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eCatalog Number\/HWC Part #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHW290 01007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eSize AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong style=\"background-color: #f2f2f2;\"\u003eSize (mm2)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNumber of Conductors\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eGrounding Conductor AWG\/kcmil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eNominal Diameter (inches)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight (lbs.\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e488\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003e90°C NEC Ampacity\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e75°C NEC Ampacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eDC Resistance at 25°C(Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eAC Resistance at 90°C, 60 Hz (Ohms\/1000 ft.)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cstrong style=\"background-color: #d0d8e5;\"\u003eVoltage Drop (Volts\/Amp\/1000 ft.)\u003c\/strong\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd\u003e\u003cstrong\u003eHL Listed\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cbr\u003e\n\u003cp\u003e\u003cstrong\u003eSpecifications:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHW290\u003c\/li\u003e\n\u003cli\u003eListed CIR® Control Cable*\u003c\/li\u003e\n\u003cli\u003eMulti-Conductor + Ground\u003c\/li\u003e\n\u003cli\u003e0.6\/1kV 90°C Gexol® Insulation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e Designed and constructed to be a flexible alternative to Type MC cable where crush and impact protection in arctic conditions is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductors:\u003c\/strong\u003e\u003cbr\u003e Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e Gexol cross-linked flame retardant polyolefin, meets requirements for Type P of IEEE 1580 and Type X110 of UL 1309\/CSA 245. 600V\/IEC 1000V.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e\u003cbr\u003e Soft annealed, flexible stranded, insulated, tinned copper sized in accordance with UL 1277.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e\u003cbr\u003e A black, flame retardant, oil, abrasion, chemical and sunlight resistant thermoset compound meeting UL 1309\/CSA 245 and IEEE 1580.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRatings \u0026amp; Approvals :\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e90°C temperature rating\u003c\/li\u003e\n\u003cli\u003eUL Listed as Marine Shipboard Cable (E111461)\u003c\/li\u003e\n\u003cli\u003eUL Listed as Type TC-ER\u003c\/li\u003e\n\u003cli\u003eUL Listed as Type TC-ER-HL*\u003c\/li\u003e\n\u003cli\u003eAmerican Bureau of Shipping (ABS) (99-BT5905-X)\u003c\/li\u003e\n\u003cli\u003eFlame Retardant – IEEE 1202\u003c\/li\u003e\n\u003cli\u003eSuitable for use in Class I, Div 2 \u0026amp; Zone 2 environments\u003c\/li\u003e\n\u003cli\u003eSuitable for use in Class I, Div 1 \u0026amp; Zone 1 environments*\u003c\/li\u003e\n\u003cli\u003e*Cables up to 1” in OD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eComplies with the requirements for TC-ER-HL* per UL 2225\u003c\/li\u003e\n\u003cli\u003eGas \u0026amp; vapor tight – impervious to water and air\u003c\/li\u003e\n\u003cli\u003eSmaller bend radius (up to 40% smaller) than Type MC\u003c\/li\u003e\n\u003cli\u003eReduced tray fill (up to 35% less) compared to Type MC\u003c\/li\u003e\n\u003cli\u003eConsiderably more flexible than Type MC\u003c\/li\u003e\n\u003cli\u003eBrittle point as per ASTM D 746-07 exceeds -65°C for Jacket and -75°C for Insulation\u003c\/li\u003e\n\u003cli\u003eExceeds CSA cold bend \/ cold impact (-40°C \/ -35°C)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctrstyle\u003e\n\u003ctable width=\"550\" bordercolor=\"#D0D8E5\" border=\"1\" style=\"text-align: center;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd colspan=\"2\" style=\"border: 1px solid #d0d8e5; color: #ffffff;\"\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Control Cable Color Legend\u003c\/strong\u003e\u003cstrong\u003e:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center; width: 244px;\"\u003e\u003cstrong\u003eConductor #\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"text-align: center; width: 290px;\"\u003e\u003cstrong\u003eColor\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e1\u003c\/td\u003e\n\u003ctd style=\"text-align: center;\"\u003eBlack\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #f2f2f2;\"\u003e2\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #d0d8e5;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e\u003cspan style=\"background-color: #d0d8e5;\"\u003e3\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003eBlue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #f2f2f2;\"\u003e\n\u003ctd style=\"text-align: center;\"\u003e4\u003c\/td\u003e\n\u003ctd\u003eOrange\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center;\"\u003e\u003c\/div\u003e\n\u003c\/trstyle\u003e \u003c\/trstyle\u003e","brand":"Houston Wire","offers":[{"title":"Default Title","offer_id":7150373535807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/HW29001402-lg_050f532c-831a-4672-ae9c-e51c072319c1.jpg?v=1571727081"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/HL_LISTED_CIR_CONTROL_CABLE.png?v=1741601809","url":"https:\/\/www.nassauelectrical.com\/collections\/hw-290-listed-cir%c2%ae-control-cable-multi-conductor-ground-0-6-1kv-90-c-gexol%c2%ae-insulation.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}