{"title":"Helukabel Tray Control 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable","description":"","products":[{"product_id":"helukabel-1-awg-4-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62989","title":"Helukabel 1 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62989","description":"\n    \n        \u003ctitle\u003eHelukabel 1 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62989\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 1 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62989. Click for a free quote. 1 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62989, 1 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62989, 62989, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e42,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e35,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1624,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e2397,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62989\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130251690047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg.jpg?v=1571726395"},{"product_id":"helukabel-1-0-awg-4-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62990","title":"Helukabel 1\/0 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62990","description":"\n    \n        \u003ctitle\u003eHelukabel 1\/0 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62990\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 1\/0 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62990. Click for a free quote. 1\/0 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62990, 1\/0 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62990, 62990, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e1\/0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e52,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e38,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e2031,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e2938,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62990\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130257195071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_8866dca8-850d-44c3-9d46-2bb7e1144072.jpg?v=1571726396"},{"product_id":"helukabel-10-awg-12-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62976","title":"Helukabel 10 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62976","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62976\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62976. Click for a free quote. 10 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62976, 10 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62976, 62976, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e5,26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e24,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e606,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1061,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62976\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130260996159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_5561fe34-2e68-4be4-b807-f0e67ef325fd.jpg?v=1571726397"},{"product_id":"helukabel-10-awg-19-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62977","title":"Helukabel 10 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62977","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62977\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62977. Click for a free quote. 10 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62977, 10 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62977, 62977, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e5,26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e27,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e959,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1528,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62977\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130261225535,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_d5f4e61b-ed1b-4660-a74a-e2b238e48be7.jpg?v=1571726397"},{"product_id":"helukabel-10-awg-2-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62970","title":"Helukabel 10 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62970","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62970\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62970. Click for a free quote. 10 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62970, 10 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62970, 62970, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e5,26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e12,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e101,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e213,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62970\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130263715903,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_712094da-d0ab-458a-99e3-d6478f3112b7.jpg?v=1571726398"},{"product_id":"helukabel-10-awg-3-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62971","title":"Helukabel 10 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62971","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62971\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62971. Click for a free quote. 10 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62971, 10 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62971, 62971, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e5,26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e12,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e151,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e283,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62971\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130271973439,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_e28fac63-fecb-4eb9-bf44-f20bf3cf50f9.jpg?v=1571726399"},{"product_id":"helukabel-10-awg-4-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62972","title":"Helukabel 10 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62972","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62972\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62972. Click for a free quote. 10 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62972, 10 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62972, 62972, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e5,26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e15,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e202,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e387,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62972\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130285113407,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_18255703-e5bb-4a20-b06c-bb6fecfcb562.jpg?v=1571726402"},{"product_id":"helukabel-10-awg-5-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62973","title":"Helukabel 10 AWG 5 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62973","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 5 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62973\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 5 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62973. Click for a free quote. 10 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62973, 10 AWG 5 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62973, 62973, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e5,26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e16,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e252,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e473,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62973\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130293796927,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_1010aaec-1140-402a-a03a-d8a6bf0c4083.jpg?v=1571726423"},{"product_id":"helukabel-10-awg-7-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62974","title":"Helukabel 10 AWG 7 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62974","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 7 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62974\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 7 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62974. Click for a free quote. 10 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62974, 10 AWG 7 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62974, 62974, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e5,26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e17,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e353,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e607,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62974\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130300448831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_0d6bae3a-20a3-41ff-94cd-a4cbb8c3930f.jpg?v=1571726425"},{"product_id":"helukabel-10-awg-9-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62975","title":"Helukabel 10 AWG 9 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62975","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 9 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62975\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 9 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62975. Click for a free quote. 10 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62975, 10 AWG 9 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62975, 62975, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e5,26\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e20,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e454,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e771,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62975\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130302152767,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_f6315d83-5845-436b-b4be-6ff45274f950.jpg?v=1571726426"},{"product_id":"helukabel-12-awg-12-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62965","title":"Helukabel 12 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62965","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62965\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62965. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62965, 12 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62965, 62965, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e3,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e18,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e381,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e613,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62965\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130309951551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_728e2858-d34c-4c38-9662-ab9ea8864328.jpg?v=1571726432"},{"product_id":"helukabel-12-awg-16-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62966","title":"Helukabel 12 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62966","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62966\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62966. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62966, 12 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62966, 62966, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e3,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e19,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e508,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e783,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62966\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130311229503,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_06adee6d-f29b-47fa-aadf-7b9b8f61a489.jpg?v=1571726433"},{"product_id":"helukabel-12-awg-19-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62967","title":"Helukabel 12 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62967","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62967\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62967. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62967, 12 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62967, 62967, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e3,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e22,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e604,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e918,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62967\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130312540223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_d0dac6e4-c736-43d0-8093-bc9d6b3192c9.jpg?v=1571726433"},{"product_id":"helukabel-12-awg-2-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62958","title":"Helukabel 12 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62958","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62958\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62958. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62958, 12 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62958, 62958, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e3,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e63,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e132,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62958\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130313949247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_44f10331-dc94-4523-adb5-95393402461d.jpg?v=1571726435"},{"product_id":"helukabel-12-awg-20-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62968","title":"Helukabel 12 AWG 20 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62968","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 20 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62968\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 20 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62968. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62968, 12 AWG 20 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62968, 62968, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e3,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e23,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e636,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e916,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62968\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130314539071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_86593bc8-b9f2-4c33-aa8a-e1c207052e4b.jpg?v=1571726435"},{"product_id":"helukabel-12-awg-25-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62969","title":"Helukabel 12 AWG 25 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62969","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 25 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62969\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 25 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62969. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62969, 12 AWG 25 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62969, 62969, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e3,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e25,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e794,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1286,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62969\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130314768447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_653900e5-2431-4070-8c08-d8cd301d4e73.jpg?v=1571726436"},{"product_id":"helukabel-12-awg-3-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62959","title":"Helukabel 12 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62959","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62959\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62959. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62959, 12 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62959, 62959, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e3,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e10,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e95,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e177,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62959\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130317029439,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_6d0df87c-8ed1-44e3-a7aa-5141c5a8d7f6.jpg?v=1571726438"},{"product_id":"helukabel-12-awg-4-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62960","title":"Helukabel 12 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62960","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62960\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62960. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62960, 12 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62960, 62960, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e3,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e11,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e127,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e201,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62960\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133727653951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_e181eeb0-8903-4019-81fe-314acd86bb04.jpg?v=1571726441"},{"product_id":"helukabel-12-awg-5-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62961","title":"Helukabel 12 AWG 5 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62961","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 5 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62961\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 5 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62961. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62961, 12 AWG 5 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62961, 62961, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e3,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e12,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e159,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e274,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62961\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133736501311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_757a52ec-e619-46ee-b728-1b18c007db7a.jpg?v=1571726444"},{"product_id":"helukabel-12-awg-6-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62962","title":"Helukabel 12 AWG 6 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62962","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 6 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62962\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 6 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62962. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62962, 12 AWG 6 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62962, 62962, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e3,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e13,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e191,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e315,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62962\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133737582655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_451fe5f5-dfec-413f-a480-b5015b943fdd.jpg?v=1571726445"},{"product_id":"helukabel-12-awg-7-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62963","title":"Helukabel 12 AWG 7 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62963","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 7 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62963\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 7 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62963. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62963, 12 AWG 7 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62963, 62963, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e3,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e13,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e222,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e353,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62963\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133742891071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_2b0fb682-177f-4cad-94f4-579b985df65a.jpg?v=1571726446"},{"product_id":"helukabel-12-awg-9-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62964","title":"Helukabel 12 AWG 9 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62964","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 9 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62964\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 9 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62964. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62964, 12 AWG 9 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62964, 62964, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e3,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e16,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e286,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e476,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62964\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133743743039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_cf3592ed-a775-468d-845e-3d26a64de1a8.jpg?v=1571726447"},{"product_id":"helukabel-14-awg-10-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62952","title":"Helukabel 14 AWG 10 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62952","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 10 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62952\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 10 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62952. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62952, 14 AWG 10 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62952, 62952, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e15,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e200,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e378,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62952\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133749084223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_2cd54c8e-c5a9-4300-98d5-5dca375334a4.jpg?v=1571726449"},{"product_id":"helukabel-14-awg-12-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62953","title":"Helukabel 14 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62953","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62953\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62953. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62953, 14 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62953, 62953, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e16,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e240,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e434,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62953\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133761273919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_24bf7d33-4aef-4b21-afa0-36abda63efad.jpg?v=1571726458"},{"product_id":"helukabel-14-awg-16-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62954","title":"Helukabel 14 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62954","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62954\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62954. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62954, 14 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62954, 62954, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e18,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e320,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e550,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62954\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133765173311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_498d325a-23a2-4b3c-b2e9-eb4397d5c90b.jpg?v=1571726459"},{"product_id":"helukabel-14-awg-18-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62955","title":"Helukabel 14 AWG 18 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62955","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 18 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62955\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 18 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62955. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62955, 14 AWG 18 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62955, 62955, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e18,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e359,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e616,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62955\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133774676031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_e2ded9d1-08cb-446d-a2c8-905a56b57347.jpg?v=1571726461"},{"product_id":"helukabel-14-awg-19-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62956","title":"Helukabel 14 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62956","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62956\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62956. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62956, 14 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62956, 62956, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e19,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e380,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e634,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62956\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133776183359,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_b8ce1a2e-deb6-45b4-aea5-204a8ee3e496.jpg?v=1571726461"},{"product_id":"helukabel-14-awg-2-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62945","title":"Helukabel 14 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62945","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62945\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62945. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62945, 14 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62945, 62945, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e8,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e40,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e100,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62945\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133785980991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_e16ca005-961a-4c59-8fde-a06b5ca24fad.jpg?v=1571726463"},{"product_id":"helukabel-14-awg-25-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62957","title":"Helukabel 14 AWG 25 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62957","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 25 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62957\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 25 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62957. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62957, 14 AWG 25 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62957, 62957, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e23,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e500,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e817,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62957\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133802594367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_7b09cc96-1056-419e-b92d-adffb020ded2.jpg?v=1571726466"},{"product_id":"helukabel-14-awg-3-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62946","title":"Helukabel 14 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62946","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62946\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62946. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62946, 14 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62946, 62946, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e60,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e117,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62946\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133817241663,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_90399a2f-9747-4b7c-947b-81bdf0a171a5.jpg?v=1571726469"},{"product_id":"helukabel-14-awg-4-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62947","title":"Helukabel 14 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62947","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62947\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62947. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62947, 14 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62947, 62947, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e10,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e80,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e141,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62947\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133837459519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_c1d57171-1f0e-4d59-a2bd-abbac98218f6.jpg?v=1571726495"},{"product_id":"helukabel-14-awg-5-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62948","title":"Helukabel 14 AWG 5 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62948","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 5 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62948\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 5 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62948. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62948, 14 AWG 5 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62948, 62948, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e10,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e100,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e152,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62948\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133844996159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_d63c9955-e2e5-4100-865a-c6822e1ee9f1.jpg?v=1571726499"},{"product_id":"helukabel-14-awg-6-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62949","title":"Helukabel 14 AWG 6 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62949","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 6 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62949\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 6 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62949. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62949, 14 AWG 6 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62949, 62949, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e11,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e120,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e216,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62949\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133846569023,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_281fa28d-4e41-4231-bf29-84e515f30eb9.jpg?v=1571726500"},{"product_id":"helukabel-14-awg-7-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62950","title":"Helukabel 14 AWG 7 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62950","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 7 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62950\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 7 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62950. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62950, 14 AWG 7 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62950, 62950, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e12,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e140,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e255,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62950\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133851582527,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_a8247ee9-5dd3-41d5-a502-9252f457ecd7.jpg?v=1571726503"},{"product_id":"helukabel-14-awg-9-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62951","title":"Helukabel 14 AWG 9 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62951","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 9 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62951\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 9 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62951. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62951, 14 AWG 9 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62951, 62951, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e2,08\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e14,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e180,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e312,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62951\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133854072895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_3c45a813-e90c-4a8e-8517-1ca305374eb9.jpg?v=1571726504"},{"product_id":"helukabel-16-awg-10-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62929","title":"Helukabel 16 AWG 10 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62929","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 10 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62929\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 10 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62929. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62929, 16 AWG 10 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62929, 62929, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e12,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e125,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e259,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62929\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133856432191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_fba96d27-cf29-4f62-98b0-62cd116bd7d7.jpg?v=1571726506"},{"product_id":"helukabel-16-awg-12-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62930","title":"Helukabel 16 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62930","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62930\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62930. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62930, 16 AWG 12 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62930, 62930, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e13,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e151,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e301,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62930\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133863444543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_95cbc4a0-8c83-424f-b261-8b4882b3ffc9.jpg?v=1571726509"},{"product_id":"helukabel-16-awg-14-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62931","title":"Helukabel 16 AWG 14 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62931","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 14 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62931\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 14 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62931. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62931, 16 AWG 14 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62931, 62931, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e14,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e176,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e356,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62931\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133864788031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_55e3184f-6e2c-47f3-8cab-d54d9ed4e808.jpg?v=1571726511"},{"product_id":"helukabel-16-awg-15-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62932","title":"Helukabel 16 AWG 15 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62932","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 15 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62932\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 15 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62932. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62932, 16 AWG 15 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62932, 62932, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e15\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e15,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e188,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e379,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62932\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133865345087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_046598ce-f44c-4edc-a326-4dcacd550376.jpg?v=1571726511"},{"product_id":"helukabel-16-awg-16-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62933","title":"Helukabel 16 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62933","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62933\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62933. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62933, 16 AWG 16 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62933, 62933, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e16,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e201,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e405,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62933\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133866295359,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_2973f8ff-1589-4b6a-973a-d2351feff009.jpg?v=1571726525"},{"product_id":"helukabel-16-awg-18-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62934","title":"Helukabel 16 AWG 18 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62934","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 18 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62934\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 18 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62934. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62934, 16 AWG 18 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62934, 62934, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e16,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e226,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e430,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62934\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133870981183,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_3938c147-9788-404d-a6c8-a1c5b0759d33.jpg?v=1571726528"},{"product_id":"helukabel-16-awg-19-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62935","title":"Helukabel 16 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62935","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62935\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62935. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62935, 16 AWG 19 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62935, 62935, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e16,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e239,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e450,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62935\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133872652351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_8a10d1d4-bf6c-49bd-89f4-00a677368d39.jpg?v=1571726529"},{"product_id":"helukabel-16-awg-2-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62921","title":"Helukabel 16 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62921","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62921\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62921. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62921, 16 AWG 2 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62921, 62921, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e7,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e25,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e80,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62921\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133877370943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_fd3437b0-e376-4113-a37c-01d32e2a653d.jpg?v=1571726531"},{"product_id":"helukabel-16-awg-20-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62936","title":"Helukabel 16 AWG 20 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62936","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 20 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62936\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 20 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62936. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62936, 16 AWG 20 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62936, 62936, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e17,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e251,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e481,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62936\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133879664703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_ca32385b-2925-4e88-9761-5d494d588d53.jpg?v=1571726532"},{"product_id":"helukabel-16-awg-25-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62937","title":"Helukabel 16 AWG 25 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62937","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 25 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62937\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 25 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62937. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62937, 16 AWG 25 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62937, 62937, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e18,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e314,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e564,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62937\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133886316607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_9e240d4a-80f0-469a-9730-6cdaa258cb44.jpg?v=1571726536"},{"product_id":"helukabel-16-awg-27-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62938","title":"Helukabel 16 AWG 27 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62938","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 27 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62938\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 27 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62938. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62938, 16 AWG 27 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62938, 62938, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e27\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e19,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e339,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e629,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62938\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133889200191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_0cd1a5e7-3b90-4794-80ee-779e98c7ff9d.jpg?v=1571726537"},{"product_id":"helukabel-16-awg-3-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62922","title":"Helukabel 16 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62922","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62922\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62922. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62922, 16 AWG 3 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62922, 62922, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e8,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e37,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e86,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62922\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133904207935,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_413beb42-e507-42b6-bded-ee6429a9f1f0.jpg?v=1571726553"},{"product_id":"helukabel-16-awg-30-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62939","title":"Helukabel 16 AWG 30 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62939","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 30 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62939\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 30 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62939. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62939, 16 AWG 30 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62939, 62939, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e20,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e377,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e701,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62939\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133912432703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_e33ae55c-2fd0-4b53-b6d7-e50bce077253.jpg?v=1571726555"},{"product_id":"helukabel-16-awg-34-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62940","title":"Helukabel 16 AWG 34 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62940","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 34 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62940\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 34 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62940. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62940, 16 AWG 34 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62940, 62940, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e34\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e22,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e427,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e775,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62940\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133917708351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_3d454d51-3427-45b3-96aa-18b7551e5a86.jpg?v=1571726556"},{"product_id":"helukabel-16-awg-4-cores-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable-62923","title":"Helukabel 16 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62923","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62923\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62923. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 62923, 16 AWG 4 Cores TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable 62923, 62923, TrayControl Cable, Oil Resistant Cable, Open Installation Cable, Flexible Cable, TC-ER Cable, PLTC-ER Cable, ITC-ER Cable, NEPA 79 Cable, UL\/CSA Control Cables, Bare Copper Conductor Cable, GN-YE Conductor Cable, PVC Insulation Cable, PVC Power Cable, TRAYCONTROL 600 Flexible TC-ER, PLTC-ER, ITC-ER, NFPA 79 Oil Resistant Open Installation Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC power cable acc. to UL Std.1277 and UL Std.2277\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e:\u003cbr\u003e\n        • UL\/CSA TC -40°C to +90°C\u003cbr\u003e\n        • UL\/AWM -40°C to +90°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • TC 600 V\u003cbr\u003e\n        • AWM 1000 V\u003cbr\u003e\n        • WTTC 1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 3000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending|radius\u003c\/strong\u003e:\u003cbr\u003e\n        • 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, fine wire with AWG dimensions\u003cbr\u003e\n        • Core insulation of special PVC with transparent nylon skin\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Separator\u003cbr\u003e\n        • Outer sheath of special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With length marking in feet\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • UV resistant\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to CSA FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eUL\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, PLTC-ER (AWG 18 - AWG 12), ITC-ER (AWG 18 - AWG 12), UL Type WTTC, UL Type MTW, NFPA 79, Oil Res I (Oil Res II also available), 90° C dry \/ 75° C wet, Class 1 Div. 2 per NEC Art. 336, 392, 501\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCSA\u003c\/strong\u003e:\u003cbr\u003e\n        • c(UL) CIC-TC FT4, CSA AWM I\/II A\/B FT4\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • TC-ER, Tray Cable Exposed Run\u003cbr\u003e\n        • Simple installation\u003cbr\u003e\n        • Outstanding flexibility\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • NFPA 79 conformant flexible power cable up to 600 V (WTTC 1000 V), for all machinery in plant construction. Suitable for installation in dry, humid and damp environments, outdoors and pipes. For underground installation and for open, unprotected installation from the cable rack to machines in industrial plants.\u003cbr\u003e\n        • = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.of cores\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross section - mm²\u003c\/td\u003e\n                    \u003ctd\u003e1,31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e8,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e50,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e120,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e62923\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133935927359,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/TC-ER_20PLTC-ER_20ITC-ER_20NFPA_2079_20600_20Cable-lg_998b3bad-c7d5-459f-b892-e2cc5ad3160c.jpg?v=1571726567"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/helukabel-traycontrol-600-flexible-tc-er-pltc-er-itc-er-nfpa-79-oil-resistant-open-installation-cable.oembed?page=6","provider":"NassauElectrical","version":"1.0","type":"link"}