{"title":"Helukabel SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable","description":"","products":[{"product_id":"helukabel-10-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22665","title":"Helukabel 10 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22665","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22665\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22665. Click for a free quote. 10 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22665, 10 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22665, 22665, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e18,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e449,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e773,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22665\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130283212863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg.jpg?v=1571726402"},{"product_id":"helukabel-10-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22666","title":"Helukabel 10 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22666","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22666\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22666. Click for a free quote. 10 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22666, 10 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22666, 22666, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e21,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e563,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e980,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22666\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130292912191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_53f8e058-79a7-4672-8655-5501cda345c7.jpg?v=1571726423"},{"product_id":"helukabel-12-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22663","title":"Helukabel 12 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22663","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22663\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22663. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22663, 12 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22663, 22663, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e17,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e294,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e516,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22663\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133726867519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_eca31f81-cdf6-4f70-b7b6-9e906c1b3660.jpg?v=1571726441"},{"product_id":"helukabel-12-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22664","title":"Helukabel 12 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22664","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22664\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22664. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22664, 12 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22664, 22664, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e19,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e374,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e641,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22664\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133736239167,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_2c053ee5-c3b7-41f8-ba25-486df899fb99.jpg?v=1571726443"},{"product_id":"helukabel-14-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22658","title":"Helukabel 14 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22658","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22658\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22658. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22658, 14 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22658, 22658, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 X 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e12,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e122,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e226,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22658\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133785817151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_60d6e276-9ebd-4c92-9f02-fc0d06e2a078.jpg?v=1571726463"},{"product_id":"helukabel-14-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22659","title":"Helukabel 14 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22659","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22659\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22659. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22659, 14 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22659, 22659, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e12,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e147,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e271,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22659\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133816324159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_bc45c69e-90a6-40af-ad1e-13a4966eeb56.jpg?v=1571726469"},{"product_id":"helukabel-14-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22660","title":"Helukabel 14 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22660","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22660\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22660. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22660, 14 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22660, 22660, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e14,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e188,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e332,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22660\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133836116031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_57bf53ff-4a7e-4fd1-afaf-c4d31e755d7d.jpg?v=1571726495"},{"product_id":"helukabel-14-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22661","title":"Helukabel 14 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22661","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22661\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22661. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22661, 14 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22661, 22661, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e15,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e214,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e384,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22661\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133844635711,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_aad4a8a7-9a71-476a-b999-b0c38d3b1b20.jpg?v=1571726499"},{"product_id":"helukabel-14-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22662","title":"Helukabel 14 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22662","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22662\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22662. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22662, 14 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22662, 22662, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e16,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e265,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e478,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22662\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133850632255,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_a3bf1e34-43aa-44f1-9cd9-e8944a9324e0.jpg?v=1571726502"},{"product_id":"helukabel-16-awg-10-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22656","title":"Helukabel 16 AWG 10 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22656","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 10 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22656\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 10 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22656. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22656, 16 AWG 10 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22656, 22656, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e10 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e17,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e268,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e478,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22656\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133856038975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_b8e5ffd2-5cbd-4c06-bc0d-276523c297ad.jpg?v=1571726506"},{"product_id":"helukabel-16-awg-12-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22657","title":"Helukabel 16 AWG 12 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22657","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 12 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22657\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 12 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22657. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22657, 16 AWG 12 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22657, 22657, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e17,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e298,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e521,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22657\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133863182399,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_7a9d04fc-66f8-49b2-be2e-ed07756fffee.jpg?v=1571726509"},{"product_id":"helukabel-16-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22651","title":"Helukabel 16 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22651","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22651\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22651. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22651, 16 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22651, 22651, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 X 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e10,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e87,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e169,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22651\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133875765311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_b5c57d36-a7bd-46f9-8649-9c7defcd81d8.jpg?v=1571726531"},{"product_id":"helukabel-16-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22652","title":"Helukabel 16 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22652","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22652\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22652. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22652, 16 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22652, 22652, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e11,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e103,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e191,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22652\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133901226047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_cc47d4fc-4970-4bd7-ab7a-40cc39242549.jpg?v=1571726553"},{"product_id":"helukabel-16-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22653","title":"Helukabel 16 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22653","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22653\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22653. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22653, 16 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22653, 22653, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e11,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e131,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e230,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22653\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133931896895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_c8721b2d-bbd3-4393-a802-fe0f9a6bbf78.jpg?v=1571726560"},{"product_id":"helukabel-16-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22654","title":"Helukabel 16 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22654","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22654\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22654. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22654, 16 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22654, 22654, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e13,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e148,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e272,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22654\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133959979071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_10f89f50-8c43-445b-bac3-300925d91456.jpg?v=1571726571"},{"product_id":"helukabel-16-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22655","title":"Helukabel 16 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22655","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22655\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22655. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22655, 16 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22655, 22655, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e14,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e193,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e341,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22655\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133985079359,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_969ed9a9-e0c8-4826-bf98-9b157c754770.jpg?v=1571726577"},{"product_id":"helukabel-18-awg-10-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22649","title":"Helukabel 18 AWG 10 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22649","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 10 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22649\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 10 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22649. Click for a free quote. 18 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22649, 18 AWG 10 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22649, 22649, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e10 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e14,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e190,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e248,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22649\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134002839615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_1e098616-6be9-44b4-a0ab-868d7802927a.jpg?v=1571726597"},{"product_id":"helukabel-18-awg-12-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22650","title":"Helukabel 18 AWG 12 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22650","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 12 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22650\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 12 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22650. Click for a free quote. 18 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22650, 18 AWG 12 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22650, 22650, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e15,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e209,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e364,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22650\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134009196607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_c810450e-0055-4622-92ff-411737735144.jpg?v=1571726600"},{"product_id":"helukabel-18-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22644","title":"Helukabel 18 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22644","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22644\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22644. Click for a free quote. 18 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22644, 18 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22644, 22644, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 X 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e66,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e130,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22644\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134179622975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_3e4453fb-a38d-4c70-8599-14ff63f878dd.jpg?v=1571726621"},{"product_id":"helukabel-18-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22645","title":"Helukabel 18 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22645","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22645\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22645. Click for a free quote. 18 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22645, 18 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22645, 22645, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e86,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e151,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22645\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134221238335,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_9f450d00-5505-4ebf-b4b1-e64d094ab5ae.jpg?v=1571726629"},{"product_id":"helukabel-18-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22646","title":"Helukabel 18 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22646","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22646\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22646. Click for a free quote. 18 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22646, 18 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22646, 22646, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e10,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e96,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e169,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22646\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134251024447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_ccca8f52-cdd9-44bc-9dd1-90e9ce4f821d.jpg?v=1571726646"},{"product_id":"helukabel-18-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22647","title":"Helukabel 18 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22647","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22647\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22647. Click for a free quote. 18 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22647, 18 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22647, 22647, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e11,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e108,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e198,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22647\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134277861439,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_a6561c16-b87f-4ea6-9585-fe3e1545f5a0.jpg?v=1571726651"},{"product_id":"helukabel-18-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22648","title":"Helukabel 18 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22648","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22648\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22648. Click for a free quote. 18 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22648, 18 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22648, 22648, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e12,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e141,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e236,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22648\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134304600127,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_3f06e8db-39ad-4aa3-8f5e-923064cfe49d.jpg?v=1571726657"},{"product_id":"helukabel-20-awg-10-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22642","title":"Helukabel 20 AWG 10 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22642","description":"\n    \n        \u003ctitle\u003eHelukabel 20 AWG 10 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22642\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 10 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22642. Click for a free quote. 20 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22642, 20 AWG 10 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22642, 22642, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e10 G 0,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e13,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e124,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e237,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22642\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134488428607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_b82c82a6-e3b6-432d-996e-a85718bb7471.jpg?v=1571726758"},{"product_id":"helukabel-20-awg-12-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22643","title":"Helukabel 20 AWG 12 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22643","description":"\n    \n        \u003ctitle\u003eHelukabel 20 AWG 12 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22643\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 12 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22643. Click for a free quote. 20 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22643, 20 AWG 12 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22643, 22643, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 0,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e13,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e134,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e260,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22643\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134501142591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_58c6b2db-b3c6-41d6-b321-623177c6b1e9.jpg?v=1571726775"},{"product_id":"helukabel-20-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22637","title":"Helukabel 20 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22637","description":"\n    \n        \u003ctitle\u003eHelukabel 20 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22637\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22637. Click for a free quote. 20 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22637, 20 AWG 2 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22637, 22637, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 X 0,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e55,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e94,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22637\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7147943231551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_ea91f521-9a4d-43b5-b814-91d8e9a0966a.jpg?v=1571726783"},{"product_id":"helukabel-20-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22638","title":"Helukabel 20 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22638","description":"\n    \n        \u003ctitle\u003eHelukabel 20 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22638\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22638. Click for a free quote. 20 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22638, 20 AWG 3 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22638, 22638, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 0,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e60,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e104,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22638\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7147997364287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_e069baee-f753-453e-8d86-18d81ebe8229.jpg?v=1571726812"},{"product_id":"helukabel-20-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22639","title":"Helukabel 20 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22639","description":"\n    \n        \u003ctitle\u003eHelukabel 20 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22639\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22639. Click for a free quote. 20 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22639, 20 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22639, 22639, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 0,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e66,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e125,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22639\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148033015871,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_a5cff0de-abf3-4dcd-ab2b-e0d6cf6ff105.jpg?v=1571726818"},{"product_id":"helukabel-20-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22640","title":"Helukabel 20 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22640","description":"\n    \n        \u003ctitle\u003eHelukabel 20 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22640\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22640. Click for a free quote. 20 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22640, 20 AWG 5 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22640, 22640, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 0,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e10,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e81,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e149,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22640\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148054183999,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_b2f8d670-95a8-43db-abde-6a16b72c06b6.jpg?v=1571726837"},{"product_id":"helukabel-20-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22641","title":"Helukabel 20 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22641","description":"\n    \n        \u003ctitle\u003eHelukabel 20 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22641\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22641. Click for a free quote. 20 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22641, 20 AWG 7 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22641, 22641, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 0,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e10,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e92,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e168,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22641\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148074106943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_dbcc830f-94ae-4bad-a7ac-83d4ea3a9521.jpg?v=1571726844"},{"product_id":"helukabel-8-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable-22667","title":"Helukabel 8 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22667","description":"\n    \n        \u003ctitle\u003eHelukabel 8 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22667\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 8 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22667. Click for a free quote. 8 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 22667, 8 AWG 4 Cores SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable 22667, 22667, SiHF-C-Si Cable, UL\/CSA Cable, Special Silicon Multicore Cable, Copper Screened Cable, EMC-Preferred Type Cable, Helukabel Cables, Tinned Copper Conductor Cable, Core Silicone Insulation Cable, GN-YE Conductor Cable, SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu-Screened EMC-Preferred Type Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e\n        • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • VDE U0\/U 300\/500 V\u003cbr\u003e\n        • UL\/CSA 600 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 200 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 5x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • max. 250 Ohm\/km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of silicone\u003cbr\u003e\n        • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e\n        • For 2-cores brown, blue\u003cbr\u003e\n        • Cores stranded in layers with optimal lay-length\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above\u003cbr\u003e\n        • Foil separator\u003cbr\u003e\n        • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e\n        • Outer sheath of silicone\u003cbr\u003e\n        • Sheath colour black\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e\n        • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e\n        • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e\n        • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e\n        • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e\n        • EMC = Electromagnetic compatibillity\u003cbr\u003e\n        • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e25,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e759,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1284,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e22667\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7150297448511,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_20ULCSA_20Halogen_20Free_20150_C2_B0C_20Cable-lg_e89dab26-90ce-499f-b2df-c02873183c29.jpg?v=1571727047"},{"product_id":"helukabel-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable","title":"Helukabel SiHF-C-Si UL\/CSA Halogen Free 150°C\/600V Two Approvals Silicon Multicore Cable Cu Screened EMC-Preferred Type Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special silicone multicore cable with higher heat-resistance range to UL Style 4476 and CSA AWM II A\/B\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • VDE -60°C to +180°C, (up to +220°C for short time)\u003cbr\u003e • UL\/CSA -50°C to +150°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • VDE U0\/U 300\/500 V\u003cbr\u003e • UL\/CSA 600 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 5000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 200 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 10x cable Ø\u003cbr\u003e • fixed installation 5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCoupling Resistance\u003c\/strong\u003e:\u003cbr\u003e • max. 250 Ohm\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 20x106 cJ\/kg (up to 20 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Tinned copper conductors to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e • Core insulation of silicone\u003cbr\u003e • Core identification to DIN VDE 0293-308 colour coded or black cores with continuous white numbers\u003cbr\u003e • For 2-cores brown, blue\u003cbr\u003e • Cores stranded in layers with optimal lay-length\u003cbr\u003e • GN-YE conductor, 3 cores and above\u003cbr\u003e • Foil separator\u003cbr\u003e • Tinned copper braided screening, approx. 85% coverage\u003cbr\u003e • Outer sheath of silicone\u003cbr\u003e • Sheath colour black\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482 part 267, DIN EN 50267-2-1, IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e • Behaviour in fire no flame propagation acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B), CSA FT1.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e \u003cstrong\u003eAdvantages\u003c\/strong\u003e:\u003cbr\u003e • Hardly changes of dielectric strength and the insulation resistance, also at high temperatures high ignition or flash point, in case of fire, forms an insulating layer of SiO2\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResistant To\u003c\/strong\u003e:\u003cbr\u003e • High molecular oils, fats from vegetables and animals, alcohols, plasticizers and clophenes, diluted acids, lyes and salt dissolution, oxidation substances, tropical influences and weather, lake water, oxygen and UV\u003cbr\u003e • For laying as a fixed installation only in open or ventilated pipe systems as well as in ducts. Otherwise the mechanical properties of the silicon are reduced by the enclosed air at temperatures exceeding 90°C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Non-screened analogue type: SiHF UL\/CSA\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e • UL-CSA approved Silicone cables were evolved for use wherever insulation is subjected to extreme temperature changes. The good performance of the environmental resistant properties means that silicone cables can be used at temperatures down to -60°C. Silicone cables are halogen-free cables and are especially suited for installation in power stations. They have also found their uses in the steel producing industries, aviation industry, ship building as well as in ceramic, glass and cement factories. Due to elastical characteristic of core insulations, these are used as flexible connection cable. An interference-free transmission of signals and pulse is assured by the high screening density. The ideal interference-protected silicone multicore flexible cable for such applications as given above.\u003cbr\u003e • EMC = Electromagnetic compatibillity\u003cbr\u003e • To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.\u003cbr\u003e • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003eno.cores x \u003cbr\u003e cross-sec.mm²\u003c\/td\u003e\n\u003ctd\u003eweight app.\u003cbr\u003ekg\/km\u003c\/td\u003e\n\u003ctd\u003ehelukabel\u003cbr\u003e part number\u003c\/td\u003e\n\u003ctd\u003eaction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 X 0,5\u003c\/td\u003e\n\u003ctd\u003e94,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22637\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 G 0,5\u003c\/td\u003e\n\u003ctd\u003e104,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22638\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 G 0,5\u003c\/td\u003e\n\u003ctd\u003e125,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22639\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 G 0,5\u003c\/td\u003e\n\u003ctd\u003e149,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22640\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7 G 0,5\u003c\/td\u003e\n\u003ctd\u003e168,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22641\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-10-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 G 0,5\u003c\/td\u003e\n\u003ctd\u003e237,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-10-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e22642\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-10-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-12-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12 G 0,5\u003c\/td\u003e\n\u003ctd\u003e260,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-12-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e22643\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-20-awg-12-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 X 1\u003c\/td\u003e\n\u003ctd\u003e130,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22644\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 G 1\u003c\/td\u003e\n\u003ctd\u003e151,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22645\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 G 1\u003c\/td\u003e\n\u003ctd\u003e169,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22646\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 G 1\u003c\/td\u003e\n\u003ctd\u003e198,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22647\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7 G 1\u003c\/td\u003e\n\u003ctd\u003e236,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22648\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-10-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 G 1\u003c\/td\u003e\n\u003ctd\u003e248,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-10-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e22649\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-10-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-12-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12 G 1\u003c\/td\u003e\n\u003ctd\u003e364,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-12-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e22650\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-18-awg-12-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 X 1,5\u003c\/td\u003e\n\u003ctd\u003e169,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22651\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 G 1,5\u003c\/td\u003e\n\u003ctd\u003e191,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22652\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 G 1,5\u003c\/td\u003e\n\u003ctd\u003e230,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22653\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 G 1,5\u003c\/td\u003e\n\u003ctd\u003e272,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22654\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote\u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7 G 1,5\u003c\/td\u003e\n\u003ctd\u003e341,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22655\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-10-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10 G 1,5\u003c\/td\u003e\n\u003ctd\u003e478,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-10-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e22656\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-10-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-12-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12 G 1,5\u003c\/td\u003e\n\u003ctd\u003e521,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-12-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e22657\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-16-awg-12-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-c\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 X 2,5\u003c\/td\u003e\n\u003ctd\u003e226,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22658\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-2-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 G 2,5\u003c\/td\u003e\n\u003ctd\u003e271,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22659\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-3-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 G 2,5\u003c\/td\u003e\n\u003ctd\u003e332,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22660\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 GX 2,5\u003c\/td\u003e\n\u003ctd\u003e384,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22661\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7 G 2,5\u003c\/td\u003e\n\u003ctd\u003e478,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22662\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-14-awg-7-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-12-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 G 4\u003c\/td\u003e\n\u003ctd\u003e516,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-12-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22663\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-12-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-12-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 G 4\u003c\/td\u003e\n\u003ctd\u003e641,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-12-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22664\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-12-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-10-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 G 6\u003c\/td\u003e\n\u003ctd\u003e773,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-10-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22665\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-10-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-10-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 G 6\u003c\/td\u003e\n\u003ctd\u003e980,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-10-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e22666\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-10-awg-5-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-ca\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-8-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cab\"\u003e8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 G 10\u003c\/td\u003e\n\u003ctd\u003e1284,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-8-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cab\"\u003e22667\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e \u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/ul-csa-single-conductor-cable\/helukabel-8-awg-4-cores-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cab\"\u003e Request A Quote \u003c\/a\u003e \u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7510255796287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/SiHF-C-Si_ULCSA_Halogen_Free_150_C_Cable.jpg?v=1571729667"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/helukabel-sihf-c-si-ul-csa-halogen-free-150-c-600v-two-approvals-silicon-multicore-cable-cu-screened-emc-preferred-type-cable.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}