{"title":"Helukabel MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable","description":"","products":[{"product_id":"helukabel-1-awg-3-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13331","title":"Helukabel 1 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13331","description":"\n    \n        \u003ctitle\u003eHelukabel 1 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13331\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 1 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13331. Click for a free quote. 1 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13331, 1 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13331, 13331, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e31,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1440,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e2700,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13331\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130243465279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg.jpg?v=1571726394"},{"product_id":"helukabel-1-awg-4-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13332","title":"Helukabel 1 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13332","description":"\n    \n        \u003ctitle\u003eHelukabel 1 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13332\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 1 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13332. Click for a free quote. 1 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13332, 1 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13332, 13332, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e35,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1920,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e3400,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13332\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130251362367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_b3ebbe59-75e6-4010-8d59-e4d1fb58a189.jpg?v=1571726395"},{"product_id":"helukabel-1-awg-5-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13333","title":"Helukabel 1 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13333","description":"\n    \n        \u003ctitle\u003eHelukabel 1 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13333\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 1 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13333. Click for a free quote. 1 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13333, 1 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13333, 13333, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e40,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e2400,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e4361,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13333\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130255786047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_a2233355-cdd9-4b30-9f84-2094a983b0ee.jpg?v=1571726396"},{"product_id":"helukabel-10-awg-2-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13310","title":"Helukabel 10 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13310","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13310\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13310. Click for a free quote. 10 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13310, 10 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13310, 13310, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 X 6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e13,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e115,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e205,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13310\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130262765631,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_334f6fed-a6aa-4e8d-9cde-7e0468833a30.jpg?v=1571726397"},{"product_id":"helukabel-10-awg-3-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13311","title":"Helukabel 10 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13311","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13311\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13311. Click for a free quote. 10 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13311, 10 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13311, 13311, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e14,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e173,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e370,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13311\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130269909055,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_ae7533d1-8adf-48d4-a3c7-d6967c8c1d18.jpg?v=1571726399"},{"product_id":"helukabel-10-awg-4-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13312","title":"Helukabel 10 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13312","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13312\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13312. Click for a free quote. 10 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13312, 10 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13312, 13312, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e15,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e230,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e430,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13312\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130280951871,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_9e69bd94-0061-4372-b554-9bad208392ce.jpg?v=1571726401"},{"product_id":"helukabel-10-awg-5-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13313","title":"Helukabel 10 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13313","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13313\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13313. Click for a free quote. 10 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13313, 10 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13313, 13313, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e17,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e288,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e650,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13313\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130291732543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_209d5362-9f4c-40b4-9f21-5fabe84dd723.jpg?v=1571726422"},{"product_id":"helukabel-10-awg-7-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13314","title":"Helukabel 10 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13314","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13314\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13314. Click for a free quote. 10 AWG\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13314, 10 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13314, 13314, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e19,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e403,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e860,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13314\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130299203647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_8d867472-72d5-4ba2-a49a-1993252322cd.jpg?v=1571726424"},{"product_id":"helukabel-12-awg-10-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13306","title":"Helukabel 12 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13306","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13306\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13306. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13306, 12 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13306, 13306, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e10 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e21,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e384,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e760,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13306\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130306543679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_66b14b67-1949-4281-9091-0b6efa3fa81a.jpg?v=1571726427"},{"product_id":"helukabel-12-awg-12-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13307","title":"Helukabel 12 AWG 12 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13307","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 12 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13307\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 12 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13307. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13307, 12 AWG 12 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13307, 13307, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e22,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e461,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e860,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13307\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130309558335,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_aba1671d-9a04-441d-bef6-20f9ed64b029.jpg?v=1571726432"},{"product_id":"helukabel-12-awg-16-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13308","title":"Helukabel 12 AWG 16 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13308","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 16 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13308\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 16 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13308. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13308, 12 AWG 16 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13308, 13308, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e16 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e23,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e614,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e910,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13308\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130311163967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_50a6f1d2-9afb-4275-8baf-2d91e49b8fed.jpg?v=1571726433"},{"product_id":"helukabel-12-awg-18-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13309","title":"Helukabel 12 AWG 18 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13309","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 18 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13309\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 18 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13309. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13309, 12 AWG 18 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13309, 13309, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e18 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e24,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e691,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e980,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13309\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130312343615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_5a6bd996-15b5-4d34-a3bd-69cc89186a23.jpg?v=1571726433"},{"product_id":"helukabel-12-awg-2-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13300","title":"Helukabel 12 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13300","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13300\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13300. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13300, 12 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13300, 13300, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 X 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e11,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e77,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e180,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13300\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130313752639,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_2ac97a40-f946-49ae-93dd-5806411f7ed4.jpg?v=1571726434"},{"product_id":"helukabel-12-awg-3-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13301","title":"Helukabel 12 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13301","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13301\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13301. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13301, 12 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13301, 13301, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e12,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e115,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e230,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13301\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130316472383,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_bca96baf-39ed-4e38-afbb-927dcb5491f1.jpg?v=1571726437"},{"product_id":"helukabel-12-awg-4-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13302","title":"Helukabel 12 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13302","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13302\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13302. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13302, 12 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13302, 13302, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e13,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e154,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e310,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13302\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133725196351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_a212e4ab-ab49-4291-b899-d73b67430678.jpg?v=1571726440"},{"product_id":"helukabel-12-awg-5-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13303","title":"Helukabel 12 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13303","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13303\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13303. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13303, 12 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13303, 13303, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e15,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e192,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e410,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13303\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133735452735,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_3dd6f19a-f0e4-4973-b5f2-6bd67964b532.jpg?v=1571726443"},{"product_id":"helukabel-12-awg-7-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13304","title":"Helukabel 12 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13304","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13304\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13304. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13304, 12 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13304, 13304, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e16,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e269,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e540,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13304\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133742039103,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_1ac08451-da62-4357-9615-0228388eaab1.jpg?v=1571726446"},{"product_id":"helukabel-12-awg-8-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13305","title":"Helukabel 12 AWG 8 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13305","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 8 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13305\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 8 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13305. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13305, 12 AWG 8 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13305, 13305, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e8 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e20,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e307,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e710,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13305\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133743546431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_386fbf7e-46ff-4a59-b35e-1885125359d7.jpg?v=1571726447"},{"product_id":"helukabel-14-awg-10-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13293","title":"Helukabel 14 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13293","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13293\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13293. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13293, 14 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13293, 13293, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e10 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e17,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e240,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e461,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13293\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133748822079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_1c92f651-ce25-4203-b5f0-45338247ffe0.jpg?v=1571726448"},{"product_id":"helukabel-14-awg-12-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13294","title":"Helukabel 14 AWG 12 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13294","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 12 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13294\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 12 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13294. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13294, 14 AWG 12 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13294, 13294, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e18,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e288,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e553,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13294\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133754163263,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_80179ea5-71da-4c7d-b22a-2caec7e47d6c.jpg?v=1571726458"},{"product_id":"helukabel-14-awg-16-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13295","title":"Helukabel 14 AWG 16 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13295","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 16 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13295\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 16 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13295. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13295, 14 AWG 16 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13295, 13295, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e16 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e19,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e384,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e742,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13295\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133765075007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_cff6e5c1-6053-4728-bb81-402ab5cc687a.jpg?v=1571726459"},{"product_id":"helukabel-14-awg-18-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13296","title":"Helukabel 14 AWG 18 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13296","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 18 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13296\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 18 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13296. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13296, 14 AWG 18 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13296, 13296, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e18 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e22,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e432,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e795,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13296\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133772972095,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_23611459-0edc-4e0b-bfe1-e7ec61fd617d.jpg?v=1571726460"},{"product_id":"helukabel-14-awg-2-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13287","title":"Helukabel 14 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13287","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13287\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13287. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13287, 14 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13287, 13287, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 X 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e48,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e160,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13287\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133780738111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_e6ac85d9-c148-4e9d-b6c9-9c0e54c4b398.jpg?v=1571726463"},{"product_id":"helukabel-14-awg-20-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13297","title":"Helukabel 14 AWG 20 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13297","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 20 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13297\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 20 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13297. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13297, 14 AWG 20 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13297, 13297, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e20 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e32,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e480,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e924,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13297\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133788602431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_304aebc5-4874-4025-b69e-518e1dbe10fd.jpg?v=1571726464"},{"product_id":"helukabel-14-awg-25-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13298","title":"Helukabel 14 AWG 25 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13298","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 25 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13298\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 25 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13298. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13298, 14 AWG 25 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13298, 13298, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e25 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e26,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e600,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1110,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13298\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133793714239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_53a021cc-0678-4c35-b923-9c1f60a7d522.jpg?v=1571726465"},{"product_id":"helukabel-14-awg-3-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13288","title":"Helukabel 14 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13288","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13288\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13288. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13288, 14 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13288, 13288, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e72,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e175,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13288\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133813243967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_3c3943e4-f18c-48c3-8a98-e85e4418ef87.jpg?v=1571726468"},{"product_id":"helukabel-14-awg-30-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13299","title":"Helukabel 14 AWG 30 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13299","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 30 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13299\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 30 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13299. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13299, 14 AWG 30 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13299, 13299, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e30 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e28,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e720,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1370,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13299\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133821894719,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_aea339e5-546c-4b76-adfd-ba8ab2e13741.jpg?v=1571726470"},{"product_id":"helukabel-14-awg-4-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13289","title":"Helukabel 14 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13289","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13289\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13289. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13289, 14 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13289, 13289, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e11,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e96,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e203,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13289\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133831692351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_28d5a41a-d64e-459f-8b73-17bfa85890c1.jpg?v=1571726494"},{"product_id":"helukabel-14-awg-5-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13290","title":"Helukabel 14 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13290","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13290\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13290. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13290, 14 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13290, 13290, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e12,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e120,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e251,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13290\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133843259455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_75719392-2feb-44be-9174-09af5528a9f5.jpg?v=1571726498"},{"product_id":"helukabel-14-awg-7-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13291","title":"Helukabel 14 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13291","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13291\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13291. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13291, 14 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13291, 13291, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e15,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e168,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e330,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13291\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133848862783,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_39b33feb-31ca-4cdf-94ca-7487e03ca178.jpg?v=1571726502"},{"product_id":"helukabel-14-awg-8-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13292","title":"Helukabel 14 AWG 8 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13292","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 8 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13292\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 8 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13292. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13292, 14 AWG 8 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13292, 13292, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e8 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e16,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e192,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e400,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13292\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133853384767,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_116e7505-96c3-40fd-929f-d1a51c2daa2f.jpg?v=1571726503"},{"product_id":"helukabel-16-awg-10-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13276","title":"Helukabel 16 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13276","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13276\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13276. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13276, 16 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13276, 13276, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e10 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e16,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e144,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e300,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13276\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133855875135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_7a058050-9c4a-4e63-a785-c694b1a855fa.jpg?v=1571726506"},{"product_id":"helukabel-16-awg-12-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13277","title":"Helukabel 16 AWG 12 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13277","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 12 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13277\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 12 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13277. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13277, 16 AWG 12 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13277, 13277, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e16,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e173,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e370,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13277\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133862133823,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_44a6c3a3-62fd-47d0-b2a5-3accaf7a38b3.jpg?v=1571726508"},{"product_id":"helukabel-16-awg-16-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13278","title":"Helukabel 16 AWG 16 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13278","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 16 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13278\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 16 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13278. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13278, 16 AWG 16 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13278, 13278, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e16 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e18,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e230,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e450,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13278\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133866131519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_e4ba45ee-2deb-4ddf-9fb2-506a02fa8830.jpg?v=1571726525"},{"product_id":"helukabel-16-awg-18-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13279","title":"Helukabel 16 AWG 18 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13279","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 18 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13279\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 18 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13279. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13279, 16 AWG 18 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13279, 13279, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e18 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e19,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e259,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e520,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13279\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133869277247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_678e798d-d41b-4b3e-bc42-96e7eac15b7a.jpg?v=1571726527"},{"product_id":"helukabel-16-awg-2-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13269","title":"Helukabel 16 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13269","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13269\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13269. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13269, 16 AWG 2 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13269, 13269, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 X 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e8,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e29,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e95,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13269\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133874847807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_f250c682-f4a1-467f-bcef-b1dc52e75b85.jpg?v=1571726530"},{"product_id":"helukabel-16-awg-20-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13280","title":"Helukabel 16 AWG 20 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13280","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 20 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13280\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 20 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13280. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13280, 16 AWG 20 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13280, 13280, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e20 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e20,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e288,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e600,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13280\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133879107647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_d8bef4c0-5c73-455b-ac50-cb0f204ca630.jpg?v=1571726532"},{"product_id":"helukabel-16-awg-25-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13281","title":"Helukabel 16 AWG 25 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13281","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 25 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13281\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 25 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13281. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13281, 16 AWG 25 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13281, 13281, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e25 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e23,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e360,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e730,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13281\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133883826239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_d0c1e9d5-c77d-4a4b-af56-e04d1eceda5c.jpg?v=1571726535"},{"product_id":"helukabel-16-awg-3-cores-1-5mm-cross-section-megaflex-600-halogen-free-flame-retardant-uv-resistant-flexible-meter-marking-cable-13271","title":"Helukabel 16 AWG 3 Cores 1.5mm² Cross-section MegaFlex 600 Halogen Free Flame Retardant UV Resistant Flexible Meter Marking Cable 13271","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 3 Cores 1.5mm² Cross-section MegaFlex 600 Halogen Free Flame Retardant UV Resistant Flexible Meter Marking Cable 13271\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 3 Cores 1.5mm² Cross-section MegaFlex 600 Halogen Free Flame Retardant UV Resistant Flexible Meter Marking Cable 13271. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13271, 16 AWG 3 Cores 1.5mm² Cross-section MegaFlex 600 Halogen Free Flame Retardant UV Resistant Flexible Meter Marking Cable 13271, 13271, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 X 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e43,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e112,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13271\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133890609215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_bf3cd3b0-ace1-40a3-8b2f-dbb6e60005c8.jpg?v=1571726551"},{"product_id":"helukabel-16-awg-3-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13270","title":"Helukabel 16 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13270","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13270\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13270. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13270, 16 AWG 3 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13270, 13270, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e43,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e112,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13270\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133898145855,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_b55ba4ef-07d5-4173-819e-f06c08eb1f5a.jpg?v=1571726552"},{"product_id":"helukabel-16-awg-34-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13282","title":"Helukabel 16 AWG 34 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13282","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 34 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13282\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 34 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13282. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13282, 16 AWG 34 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13234, 13234, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e34 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e27,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e490,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e950,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13282\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133916790847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_6d420cd1-0452-446d-a66c-a05a6b2b9ee1.jpg?v=1571726556"},{"product_id":"helukabel-16-awg-37-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13283","title":"Helukabel 16 AWG 37 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13283","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 37 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13283\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 37 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13283. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13283, 16 AWG 37 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13283, 13283, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e37 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e29,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e533,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1094,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13283\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133920690239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_93a83fba-2ab8-40f4-bf22-ba3a47ca0100.jpg?v=1571726557"},{"product_id":"helukabel-16-awg-4-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13272","title":"Helukabel 16 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13272","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13272\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13272. Click for a free quote. 12 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13272, 16 AWG 4 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13272, 13272, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e58,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e139,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13272\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133928423487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_6baf8529-ca35-4f75-a27e-32d04abc5bdb.jpg?v=1571726559"},{"product_id":"helukabel-16-awg-5-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13273","title":"Helukabel 16 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13273","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13273\u003c\/title\u003e\n        \u003cmeta name=\"Description\"\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13273. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13273, 16 AWG 5 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13273, 13273, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e11,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e72,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e170,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13273\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133956898879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_20c7bf87-f354-4046-890c-d2895957455a.jpg?v=1571726570"},{"product_id":"helukabel-16-awg-50-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13284","title":"Helukabel 16 AWG 50 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13284","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 50 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13284\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 50 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13284. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13284, 16 AWG 50 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13284, 13284, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e50 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e32,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e720,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1400,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13284\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133966073919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_37ec0cd1-050a-4a92-aeb1-5e053f423f2a.jpg?v=1571726573"},{"product_id":"helukabel-16-awg-61-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13285","title":"Helukabel 16 AWG 61 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13285","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 61 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13285\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 61 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13285. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13285, 16 AWG 61 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13285, 13285, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e61 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e35,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e878,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1700,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13285\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133973250111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_483950cc-225b-443d-9b9a-1e89f4c3c8ea.jpg?v=1571726574"},{"product_id":"helukabel-16-awg-65-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13286","title":"Helukabel 16 AWG 65 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13286","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 65 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13286\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 65 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13286. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13286, 16 AWG 65 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13286, 13286, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e65 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e36,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e936,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1900,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13286\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133975281727,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_6b326312-8e21-4df5-926a-0189e1fecde1.jpg?v=1571726574"},{"product_id":"helukabel-16-awg-7-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13274","title":"Helukabel 16 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13274","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13274\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13274. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13274, 16 AWG 7 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13274, 13274, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e13,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e101,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e225,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13274\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133982130239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_29ce34ca-3680-4533-8fcf-871bb91b9a3b.jpg?v=1571726576"},{"product_id":"helukabel-16-awg-8-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13275","title":"Helukabel 16 AWG 8 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13275","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 8 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13275\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 8 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13275. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13275, 16 AWG 8 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13275, 13275, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e8 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e14,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e115,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e250,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13275\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133990420543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_220a4baa-5dda-49fd-bb7b-3e3c2cd86367.jpg?v=1571726578"},{"product_id":"helukabel-18-awg-10-cores-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable-13256","title":"Helukabel 18 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13256","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13256\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13256. Click for a free quote. 18 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 13256, 18 AWG 10 Cores MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable 13256, 13256, Helukabel Cables, MegaFlex Cable, Halogen-Free Cable, Flame Retardant Cable, Oil Resistant Cable, UV Resistant Cable, Flexible Cable, Tray Control Cable, Bare Copper Conductor Cable, Halogen-free Insulation Cable, GN-YE Conductor Cable, MegaFlex 600 Halogen Free Flame Retardant Oil Resistant UV Resistant Flexible Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e: Halogen-free flexible control cable to UL-Style 20234, UL-Std.758\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 600\/1000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 10x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eFlexibility\u003c\/strong\u003e: Alternate bending test acc. to DIN VDE 0473-396 \/ DIN EN 50396\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper, fine wire conductors, to DIN VDE 0295 cl.5, BS 6360 cl.5 and IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of halogen-free special polymer\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layer with optimal lay-length\u003cbr\u003e\n        • Outer sheath, halogen-free special polymer\u003cbr\u003e\n        • Sheath colour black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Halogen-free\u003cbr\u003e\n        • Highly flame-retardant\u003cbr\u003e\n        • Resistant to oils and greases\u003cbr\u003e\n        • Resistant to UV and weathering\u003cbr\u003e\n        • Hydrolysis resistant\u003cbr\u003e\n        • Flexible, abrasion- and wear-resistant\u003cbr\u003e\n        • Ozone-resistantRecycleable\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)\u003cbr\u003e\n        • Self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2\/IEC 60332-1 (previously DIN VDE 0472 part 804 test method B)\u003cbr\u003e\n        • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to NF X 10-702\u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482 part 267\/ EN 50267-2-1\/ IEC 60754-1 (equivalent DIN VDE 0472 part 815)\u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2\/ IEC 61034-1+2, BS 7622 part 1+2 (previously DIN VDE 0472 part 816)\u003cbr\u003e\n        • Oil-resistant to DIN VDE 0473-811-404\/DIN EN 60811-404\u003cbr\u003e\n        • Hydrolysis-resistant to DIN EN 61234-1\u003cbr\u003e\n        • Ozone-resistant to DIN VDE 0473-811-403\/DIN EN 60811-403\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with green-yellow conductor x = without green-yellow conductor\u003cbr\u003e\n        • Screened analogue type: MEGAFLEX® 600-C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        • For fixed installation or flexible application, with occasional not permanently recurring free movement without forced motion and without tensile stress, for high mechanical strain. As a measuring and control cable in tool machinery, conveyor belts and production lines, plant engineering, climate engineering, in foundries and steel mills. Especially suited for wind power plant and computer equipment.\u003cbr\u003e\n        • = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e10 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e14,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e96,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e270,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e13256\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134002741311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/MegaFlex_20600_20Halogen-Free_20Cable-lg_b1aef031-5ad7-4cec-a53c-b109c85b2331.jpg?v=1571726597"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/helukabel-megaflex-600-halogen-free-flame-retardant-oil-resistant-uv-resistant-flexible-meter-marking-cable.oembed?page=5","provider":"NassauElectrical","version":"1.0","type":"link"}