{"title":"Helukabel JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable","description":"","products":[{"product_id":"helukabel-10-awg-3-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11861","title":"Helukabel 10 AWG 3 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11861","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e14,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e173,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e370,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11861\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130266533951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg.jpg?v=1571726398"},{"product_id":"helukabel-10-awg-3-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11926","title":"Helukabel 10 AWG 3 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11926","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e14,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e173,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e370,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11926\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130267484223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg.jpg?v=1571726398"},{"product_id":"helukabel-10-awg-4-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11862","title":"Helukabel 10 AWG 4 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11862","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e230,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e430,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11862\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130275840063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_e722bb5d-5282-4ec7-8dac-deb926589226.jpg?v=1571726400"},{"product_id":"helukabel-10-awg-4-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11927","title":"Helukabel 10 AWG 4 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11927","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e230,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e430,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11927\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130276724799,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_8073c0bd-b37f-4427-a573-f8cde0101ed1.jpg?v=1571726400"},{"product_id":"helukabel-10-awg-5-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11863","title":"Helukabel 10 AWG 5 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11863","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e17,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e288,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e650,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11863\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130287996991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_8ada3e52-0a0e-4d09-910f-9f6430b408f4.jpg?v=1571726403"},{"product_id":"helukabel-10-awg-5-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11928","title":"Helukabel 10 AWG 5 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11928","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e17,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e288,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e650,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11928\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130288390207,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_9d4e61a7-a34d-45e2-bc3e-23e47ff68c67.jpg?v=1571726403"},{"product_id":"helukabel-10-awg-7-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11864","title":"Helukabel 10 AWG 7 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11864","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e19,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e403,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e860,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11864\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130296778815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_26c24174-faaf-47e4-9ac8-a911d5b5513f.jpg?v=1571726424"},{"product_id":"helukabel-10-awg-7-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11929","title":"Helukabel 10 AWG 7 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11929","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e19,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e403,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e860,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11929\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130296975423,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_3dc9b47a-8dcc-4c78-8f71-09587fcecf36.jpg?v=1571726424"},{"product_id":"helukabel-12-awg-12-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11860","title":"Helukabel 12 AWG 12 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11860","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e22,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e461,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e860,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11860\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130307526719,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_09df3784-c4d8-4207-a378-40eff94d1a81.jpg?v=1571726427"},{"product_id":"helukabel-12-awg-12-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11925","title":"Helukabel 12 AWG 12 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11925","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e22,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e461,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e860,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11925\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130307657791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_ddd69175-6403-4ba2-ad46-0f139a70bc8e.jpg?v=1571726427"},{"product_id":"helukabel-12-awg-2-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11855","title":"Helukabel 12 AWG 2 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11855","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e11,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e77,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e180,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11855\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130312769599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_effccd3f-d99f-4c75-bf12-7345c831b5e7.jpg?v=1571726433"},{"product_id":"helukabel-12-awg-2-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11920","title":"Helukabel 12 AWG 2 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11920","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e11,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e77,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e180,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130313064511,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_c407bb86-b98e-46a6-965b-3cc3aa96bc13.jpg?v=1571726434"},{"product_id":"helukabel-12-awg-3-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11856","title":"Helukabel 12 AWG 3 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11856","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 x 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e12,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e115,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e230,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11856\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130314899519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_495cdc1f-3561-4396-83d9-1ad414a1671e.jpg?v=1571726436"},{"product_id":"helukabel-12-awg-3-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11921","title":"Helukabel 12 AWG 3 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11921","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e12,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e115,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e230,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11921\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130315194431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_42bf9b77-855f-4bd5-a87a-05eb038611f0.jpg?v=1571726436"},{"product_id":"helukabel-12-awg-4-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11857","title":"Helukabel 12 AWG 4 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11857","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e13,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e154,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e310,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11857\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130318110783,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_8ab951e4-6381-487c-aa30-4a9a2634dd8f.jpg?v=1571726438"},{"product_id":"helukabel-12-awg-4-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11922","title":"Helukabel 12 AWG 4 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11922","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e13,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e154,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e310,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11922\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133720444991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_66651bdb-1c3d-4371-8b3f-e863583533f1.jpg?v=1571726439"},{"product_id":"helukabel-12-awg-5-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11858","title":"Helukabel 12 AWG 5 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11858","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e192,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e410,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11858\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133729390655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_fae62375-eeff-431a-ba5f-1928f5610d51.jpg?v=1571726442"},{"product_id":"helukabel-12-awg-5-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11923","title":"Helukabel 12 AWG 5 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11923","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e192,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e410,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11923\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133732962367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_44c9e91f-2238-4050-9b29-5f4bd583b569.jpg?v=1571726442"},{"product_id":"helukabel-12-awg-7-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11859","title":"Helukabel 12 AWG 7 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11859","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e16,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e269,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e540,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133737713727,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_c4414911-abc9-4112-b60e-974e30998769.jpg?v=1571726445"},{"product_id":"helukabel-12-awg-7-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11924","title":"Helukabel 12 AWG 7 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11924","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e16,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e269,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e540,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11924\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133740269631,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_8d129682-7dec-40c5-8dc1-2e777449c826.jpg?v=1571726445"},{"product_id":"helukabel-14-awg-12-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11852","title":"Helukabel 14 AWG 12 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11852","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e18,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e288,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e553,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133749608511,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_d9a6fb24-e90e-4e2e-b505-b3d51f759e92.jpg?v=1571726449"},{"product_id":"helukabel-14-awg-12-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11917","title":"Helukabel 14 AWG 12 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11917","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e18,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e288,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e553,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11917\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133750558783,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_0f5791bd-a5f3-4ab8-a765-90b677cc1159.jpg?v=1571726449"},{"product_id":"helukabel-14-awg-18-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11853","title":"Helukabel 14 AWG 18 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11853","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e22,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e432,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e795,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11853\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133765828671,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_e820dd40-fb65-4587-80a3-d4306df7dc86.jpg?v=1571726459"},{"product_id":"helukabel-14-awg-18-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11918","title":"Helukabel 14 AWG 18 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11918","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e22,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e432,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e795,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11918\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133766484031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_71693145-298e-4c25-b729-b2d15bb022eb.jpg?v=1571726460"},{"product_id":"helukabel-14-awg-2-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11847","title":"Helukabel 14 AWG 2 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11847","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e48,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e160,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11847\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133776707647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_645b69cf-fbc8-426b-910b-0ca9f62b9307.jpg?v=1571726462"},{"product_id":"helukabel-14-awg-2-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11912","title":"Helukabel 14 AWG 2 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11912","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e48,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e160,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11912\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133777526847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_97bb0abe-392a-41b0-b92c-0b73ebdb5757.jpg?v=1571726462"},{"product_id":"helukabel-14-awg-25-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11854","title":"Helukabel 14 AWG 25 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11854","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e26,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e600,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e1110,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11854\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133790634047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_53ec457c-d3a0-4770-8b33-adc4dcc135e9.jpg?v=1571726464"},{"product_id":"helukabel-14-awg-25-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11919","title":"Helukabel 14 AWG 25 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11919","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e26,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e600,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e1110,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11919\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133791191103,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_2d4a4589-5633-4dec-b6a6-a8c1ea68cf59.jpg?v=1571726464"},{"product_id":"helukabel-14-awg-3-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11848","title":"Helukabel 14 AWG 3 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11848","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e175,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11848\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133804462143,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_30d2c01d-574f-4136-9ad0-b0247bab127b.jpg?v=1571726466"},{"product_id":"helukabel-14-awg-3-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11913","title":"Helukabel 14 AWG 3 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11913","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e175,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11913\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133805609023,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_bd911caf-ae28-485c-8804-8d6d9f300647.jpg?v=1571726466"},{"product_id":"helukabel-14-awg-4-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11849","title":"Helukabel 14 AWG 4 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11849","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e11,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e96,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e203,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11849\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133824745535,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_0bfb7984-6f58-47fb-8816-20ffafca9537.jpg?v=1571726470"},{"product_id":"helukabel-14-awg-4-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11914","title":"Helukabel 14 AWG 4 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11914","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e11,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e96,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e203,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11914\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133826383935,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_3dc82502-112b-4b00-a103-45c87d1088cc.jpg?v=1571726471"},{"product_id":"helukabel-14-awg-5-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11850","title":"Helukabel 14 AWG 5 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11850","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e12,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e120,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e251,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133840539711,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_1e9514db-f844-4027-aeae-645a98a09dec.jpg?v=1571726496"},{"product_id":"helukabel-14-awg-5-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11915","title":"Helukabel 14 AWG 5 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11915","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e12,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e120,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e251,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133840769087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_bf13da97-cf38-4f02-88e4-dc0d57f2debf.jpg?v=1571726496"},{"product_id":"helukabel-14-awg-7-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11851","title":"Helukabel 14 AWG 7 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11851","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e168,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e330,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11851\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133847093311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_2d7f8c7d-bf70-4c01-bf1b-aa80bb6724b0.jpg?v=1571726500"},{"product_id":"helukabel-14-awg-7-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11916","title":"Helukabel 14 AWG 7 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11916","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e168,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e330,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11916\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133847322687,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_892dde2e-7d15-4583-9b1c-7872e54a84c4.jpg?v=1571726501"},{"product_id":"helukabel-16-awg-12-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11844","title":"Helukabel 16 AWG 12 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11844","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 x 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e16,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e173,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e370,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11844\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133859643455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_5f9456d4-8eac-4250-807f-3f3ce642cd8c.jpg?v=1571726507"},{"product_id":"helukabel-16-awg-12-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11909","title":"Helukabel 16 AWG 12 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11909","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e16,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e173,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e370,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11909\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133860036671,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_62a6a87e-227a-4395-92ff-4c47373a644f.jpg?v=1571726507"},{"product_id":"helukabel-16-awg-18-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11845","title":"Helukabel 16 AWG 18 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11845","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 x 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e19,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e259,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e520,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133866754111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_49b63f18-dec6-40f2-8055-5047d3f8d928.jpg?v=1571726526"},{"product_id":"helukabel-16-awg-18-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11910","title":"Helukabel 16 AWG 18 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11910","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e19,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e259,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e520,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133867147327,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_3bbe373b-d048-479b-a13d-b787a1c1dc33.jpg?v=1571726526"},{"product_id":"helukabel-16-awg-2-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11839","title":"Helukabel 16 AWG 2 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11839","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e8,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e29,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e95,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11839\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133872881727,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_fced1731-f66a-459b-8305-fab51431f30e.jpg?v=1571726529"},{"product_id":"helukabel-16-awg-2-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11904","title":"Helukabel 16 AWG 2 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11904","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e8,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e29,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e95,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11904\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133873274943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_ec41e519-d2dc-40d5-bc68-f144ce60fdba.jpg?v=1571726529"},{"product_id":"helukabel-16-awg-25-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11846","title":"Helukabel 16 AWG 25 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11846","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 x 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e23,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e360,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e730,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11846\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133881532479,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_6cffd97c-04a7-4681-ba2f-21ff332b35c3.jpg?v=1571726533"},{"product_id":"helukabel-16-awg-25-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11911","title":"Helukabel 16 AWG 25 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11911","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e23,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e360,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e730,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11911\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133881925695,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_93a1c903-6dd4-4dfb-a877-17f3c1b61b55.jpg?v=1571726534"},{"product_id":"helukabel-16-awg-3-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11840","title":"Helukabel 16 AWG 3 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11840","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 x 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e43,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e112,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133890838591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_e61a24b0-eed1-432c-b528-02bb3c3a0d0b.jpg?v=1571726551"},{"product_id":"helukabel-16-awg-3-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11905","title":"Helukabel 16 AWG 3 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11905","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e43,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e112,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11905\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133892542527,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_cf17533a-92e4-4260-8c13-2cc6bf0dfa83.jpg?v=1571726551"},{"product_id":"helukabel-16-awg-4-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11841","title":"Helukabel 16 AWG 4 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11841","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 x 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e58,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e139,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11841\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133921706047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_3e9951ad-273e-411c-91ad-98984b87c292.jpg?v=1571726557"},{"product_id":"helukabel-16-awg-4-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11906","title":"Helukabel 16 AWG 4 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11906","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e58,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e139,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11906\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133923082303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_99074cce-68c0-4a09-b6cf-6b2ddbf6ca81.jpg?v=1571726558"},{"product_id":"helukabel-16-awg-5-cores-black-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11842","title":"Helukabel 16 AWG 5 Cores Black Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11842","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 x 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e11,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e170,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11842\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133949362239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Black_20Colour-lg_4cb3d922-965a-4d97-ba19-4c80e5454f26.jpg?v=1571726569"},{"product_id":"helukabel-16-awg-5-cores-grey-colour-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable-11907","title":"Helukabel 16 AWG 5 Cores Grey Colour JZ-600 Flexible Number Coded Meter Marking UL\/CSA 0.6\/1kV Cable 11907","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e\u003cbr\u003e • Special PVC control cables adapted to DIN VDE 0276 part 627, DIN VDE 0285-525-2-51 \/DIN EN 50525-2-51, with insulation thickness for 1 kV and to UL Std.758 Style 21179\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003cbr\u003e • flexing -5°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage\u003c\/strong\u003e\u003cbr\u003e • VDE U0\/U 600\/1000 V\u003cbr\u003e • UL\/CSA 1000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage\u003c\/strong\u003e\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage\u003c\/strong\u003e\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance\u003c\/strong\u003e\u003cbr\u003e • flexing 7,5x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance\u003c\/strong\u003e\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 and class 43 acc. to UL Std.1581\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 and class 43 acc. to UL Std.1581\u003cbr\u003e • Sheath colour: black (RAL 9005) or grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\"\u003cbr\u003e • UV resistant (building with black sheath)\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning\u003cbr\u003e and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without\u003cbr\u003e tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation, building with black sheath). Is not suitable to be\u003cbr\u003e used as direct burrial- or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable\u003cbr\u003e has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The\u003cbr\u003e black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNo.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e11,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecop. weight kg\/km\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e170,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHelukabel Part Number\u003c\/td\u003e\n\u003ctd\u003e11907\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133950312511,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Grey_20Colour-lg_2de4e2e6-1349-44fe-8396-0e08e2862ddc.jpg?v=1571726569"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/helukabel-jz-600-flexible-number-coded-meter-marking-ul-csa-0-6-1kv-cable.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}