{"title":"Helukabel JZ-600 Flexible Number Coded Bare Copper Conductor 0,6\/1kV Meter Marking Cable","description":"","products":[{"product_id":"helukabel-1-awg-3-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10735","title":"Helukabel 1 AWG 3 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10735","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e32,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e1440,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e2700,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130241925183,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG.jpg?v=1571726394"},{"product_id":"helukabel-1-awg-4-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10736","title":"Helukabel 1 AWG 4 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10736","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e35,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e1920,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e3400,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10736\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130247168063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_7b3dc6ed-4db4-4599-8727-1de56b9175d5.jpg?v=1571726395"},{"product_id":"helukabel-1-awg-5-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10742","title":"Helukabel 1 AWG 5 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10742","description":"\n    \n        \u003ctitle\u003eHelukabel 1 AWG 5 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10742\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 1 AWG 5 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10742. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel, Helukabel Quote, 1 AWG 5 Cores Cable, 1 AWG 5 Cores Quote, 1 AWG 5 Cores JZ-600 With GN-YE Conductor Cable, 1 AWG 5 Cores JZ-600 With GN-YE Conductor Price, 1 AWG 5 Cores JZ-600 With GN-YE Conductor Quote, Flexible Number Coded 0,6\/1kV Meter Marking Cable, Flexible Number Coded 0,6\/1kV Meter Marking Cable Quote, 10742.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e\n        • Flexing -15°C to +80°C \u003cbr\u003e\n        • Fixed installation -40°C to +80°C \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 0,6\/1 kV \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e\n        • 4000 V \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e\n        • Min. 8000 V \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e\n        • Min. 20 MOhm x km \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 7,5x cable Ø \u003cbr\u003e\n        • Fixed installation 4x cable Ø \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e\n        • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e\n        • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length \u003cbr\u003e\n        • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e\n        • Sheath colour: black (RAL 9005) \u003cbr\u003e\n        • With meter marking \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e\n        • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e\n        • UV resistant \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e\n        • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804\n        test method B) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e\n        • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e\n        • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily\n        identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e39,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e2400,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e4361,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e10742\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130254245951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_4c6b6e16-f13b-4952-be40-62dc1c54ee47.jpg?v=1571726396"},{"product_id":"helukabel-10-awg-3-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10716","title":"Helukabel 10 AWG 3 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10716","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e13,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e173,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e370,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130268729407,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_67659c6c-0dd7-4128-a935-12c8a6058128.jpg?v=1571726399"},{"product_id":"helukabel-10-awg-4-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10717","title":"Helukabel 10 AWG 4 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10717","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e14,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e230,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e430,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10717\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130279247935,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_d409197d-5b6d-443f-8088-be6e5ebec268.jpg?v=1571726400"},{"product_id":"helukabel-10-awg-5-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10718","title":"Helukabel 10 AWG 5 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10718","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e16,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e288,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e650,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10718\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130290520127,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_157599e3-ce57-4fd4-96ce-24a173d9603f.jpg?v=1571726422"},{"product_id":"helukabel-10-awg-7-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10719","title":"Helukabel 10 AWG 7 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10719","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e18,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e403,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e860,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10719\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130297663551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_78b4196a-a1d6-4297-a608-4f3332ff1a13.jpg?v=1571726424"},{"product_id":"helukabel-12-awg-12-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10715","title":"Helukabel 12 AWG 12 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10715","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e21,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e461,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e860,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130308575295,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_828be5b3-f109-4166-88eb-c6596cb2df6b.jpg?v=1571726432"},{"product_id":"helukabel-12-awg-2-cores-jz-600-without-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10709","title":"Helukabel 12 AWG 2 Cores JZ-600 Without GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10709","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e11,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e77,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e180,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10709\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130313326655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_88b42cfa-ca02-46a6-a842-b8622027c9b4.jpg?v=1571726434"},{"product_id":"helukabel-12-awg-3-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10710","title":"Helukabel 12 AWG 3 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10710","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e11,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e115,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e230,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130315980863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_ff55bff5-b7e2-4251-9b89-862471d89a0e.jpg?v=1571726437"},{"product_id":"helukabel-12-awg-4-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10711","title":"Helukabel 12 AWG 4 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10711","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e13,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e154,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e310,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133721133119,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_8ebd5476-41fe-4de0-be80-c3e1c3bfb5d4.jpg?v=1571726439"},{"product_id":"helukabel-12-awg-5-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10712","title":"Helukabel 12 AWG 5 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10712","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e14,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e192,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e410,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10712\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133733519423,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_737c6aa6-0834-47f7-a4ce-4873bf0d78e6.jpg?v=1571726443"},{"product_id":"helukabel-12-awg-7-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10713","title":"Helukabel 12 AWG 7 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10713","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e269,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e540,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10713\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133741350975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_f8a68387-738a-461a-b950-d2472f1d382b.jpg?v=1571726445"},{"product_id":"helukabel-12-awg-8-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10714","title":"Helukabel 12 AWG 8 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10714","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e8 G 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e17,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e307,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e710,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10714\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133743415359,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_c0db516e-86f3-49fe-9459-4c73e34397c6.jpg?v=1571726447"},{"product_id":"helukabel-14-awg-100-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10708","title":"Helukabel 14 AWG 100 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10708","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e100 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e49,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e2400,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e3850,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10708\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133749313599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_53cb3e55-90e6-46ac-af24-febbbafdf6a4.jpg?v=1571726449"},{"product_id":"helukabel-14-awg-12-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10699","title":"Helukabel 14 AWG 12 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10699","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e18,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e288,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e553,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10699\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133751869503,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_02607c0c-2022-4db1-80aa-e112657ee457.jpg?v=1571726450"},{"product_id":"helukabel-14-awg-14-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10700","title":"Helukabel 14 AWG 14 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10700","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e14 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e19,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e336,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e630,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133763797055,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_f5937681-8a8d-4fc4-864b-1626c0090d6f.jpg?v=1571726459"},{"product_id":"helukabel-14-awg-18-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10701","title":"Helukabel 14 AWG 18 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10701","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e22,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e432,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e795,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10701\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133767729215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_b8d93715-a4f8-491b-b0de-57667fd5263a.jpg?v=1571726460"},{"product_id":"helukabel-14-awg-2-cores-jz-600-without-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10689","title":"Helukabel 14 AWG 2 Cores JZ-600 Without GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10689","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e48,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e160,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10689\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133779329087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_a6f29e47-b225-4899-94bc-30b9b4bfd550.jpg?v=1571726462"},{"product_id":"helukabel-14-awg-21-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10702","title":"Helukabel 14 AWG 21 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10702","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e21 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e23,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e504,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e930,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133789487167,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_c0c66a03-5b2f-4aad-a032-fb50bfa4fddd.jpg?v=1571726464"},{"product_id":"helukabel-14-awg-25-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10703","title":"Helukabel 14 AWG 25 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10703","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e26,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e600,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e1110,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133791879231,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_282bad9d-c45d-49d8-bf98-173a1b37c16a.jpg?v=1571726465"},{"product_id":"helukabel-14-awg-3-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10690","title":"Helukabel 14 AWG 3 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10690","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e10,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e175,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10690\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133808263231,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_74d10a0a-2c44-43af-9545-28e58d050765.jpg?v=1571726467"},{"product_id":"helukabel-14-awg-3-cores-jz-600-without-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10691","title":"Helukabel 14 AWG 3 Cores JZ-600 Without GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10691","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e10,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e175,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10691\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133808295999,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_ca835d85-2dec-4e09-b792-f722bc123980.jpg?v=1571726467"},{"product_id":"helukabel-14-awg-34-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10704","title":"Helukabel 14 AWG 34 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10704","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e34 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e30,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e816,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e1450,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10704\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133822713919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_bbcc180e-f9cc-431b-bd7b-702953a518c4.jpg?v=1571726470"},{"product_id":"helukabel-14-awg-4-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10692","title":"Helukabel 14 AWG 4 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10692","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e11,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e96,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e203,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10692\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133829365823,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_2c93c7c4-c059-4e5c-9b3d-6d2bcbb28d79.jpg?v=1571726472"},{"product_id":"helukabel-14-awg-4-cores-jz-600-without-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10693","title":"Helukabel 14 AWG 4 Cores JZ-600 Without GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10693","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e11,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e96,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e203,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10693\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133829398591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_1ce20030-42fe-47d7-80cd-972ea30bc5ea.jpg?v=1571726472"},{"product_id":"helukabel-14-awg-42-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10705","title":"Helukabel 14 AWG 42 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10705","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e42 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e33,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e1008,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e1750,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133840310335,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_3b81edde-5113-4fd9-a118-11eccf5c076c.jpg?v=1571726496"},{"product_id":"helukabel-14-awg-5-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10694","title":"Helukabel 14 AWG 5 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10694","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e12,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e120,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e251,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10694\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133842047039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_f55058a4-c342-4545-99ae-688db2f0a0b7.jpg?v=1571726497"},{"product_id":"helukabel-14-awg-5-cores-jz-600-without-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10695","title":"Helukabel 14 AWG 5 Cores JZ-600 Without GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10695","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e12,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e120,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e251,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10695\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133842079807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_c68e257d-0b03-4bf7-9e76-62eddac3c8d0.jpg?v=1571726497"},{"product_id":"helukabel-14-awg-50-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10706","title":"Helukabel 14 AWG 50 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10706","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e50 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e36,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e1200,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e2100,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10706\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133845946431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_11ca76e6-e23a-4ed7-b01a-b320a44c6274.jpg?v=1571726500"},{"product_id":"helukabel-14-awg-61-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10707","title":"Helukabel 14 AWG 61 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10707","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e61 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e38,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e1464,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e2540,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10707\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133846732863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_ea0182f6-5393-4129-b9bf-06e99ff8f4cf.jpg?v=1571726500"},{"product_id":"helukabel-14-awg-7-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10696","title":"Helukabel 14 AWG 7 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10696","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e13,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e168,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e330,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10696\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133847945279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_b8e987f9-68aa-491e-b345-8279ff869cba.jpg?v=1571726501"},{"product_id":"helukabel-14-awg-7-cores-jz-600-without-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10697","title":"Helukabel 14 AWG 7 Cores JZ-600 Without GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10697","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 x 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e13,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e168,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e330,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10697\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133848010815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_bc15e934-9aa2-496f-aadd-3e1e5d2b322d.jpg?v=1571726501"},{"product_id":"helukabel-14-awg-8-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10698","title":"Helukabel 14 AWG 8 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10698","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e8 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e192,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e400,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10698\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133853155391,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_798b7a2a-8557-4482-ad9a-37fe8ce67b0c.jpg?v=1571726503"},{"product_id":"helukabel-16-awg-10-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10668","title":"Helukabel 16 AWG 10 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10668","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e10 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e144,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e300,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10668\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133855744063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_1aa58db1-afbd-4262-a3b0-cadfc63cac50.jpg?v=1571726505"},{"product_id":"helukabel-16-awg-100-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10688","title":"Helukabel 16 AWG 100 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10688","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e100 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e41,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e1440,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e2700,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10688\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133857022015,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_e1a9410b-d9ff-47b5-a58b-c0dbfcc882ed.jpg?v=1571726506"},{"product_id":"helukabel-16-awg-11-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10669","title":"Helukabel 16 AWG 11 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10669","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e11 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e158,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e330,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10669\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133857316927,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_ce8a1cd5-8221-4229-bb27-75393b22d896.jpg?v=1571726506"},{"product_id":"helukabel-16-awg-12-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10670","title":"Helukabel 16 AWG 12 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10670","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e173,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e370,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133860823103,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_0bdb3f80-6c37-473e-98b3-82dc966b5f18.jpg?v=1571726507"},{"product_id":"helukabel-16-awg-12-cores-jz-600-without-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10671","title":"Helukabel 16 AWG 12 Cores JZ-600 Without GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10671","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 x 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e173,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e370,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10671\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133860986943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_efc7b95d-5853-4fcb-9a3d-7eb7ef979440.jpg?v=1571726507"},{"product_id":"helukabel-16-awg-14-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10672","title":"Helukabel 16 AWG 14 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10672","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e14 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e16,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e202,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e400,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10672\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133864591423,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_67b49eb2-0dea-43fc-9c58-f0f68b782ad5.jpg?v=1571726511"},{"product_id":"helukabel-16-awg-16-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10673","title":"Helukabel 16 AWG 16 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10673","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e16 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e17,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e230,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e450,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10673\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133866000447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_f8557502-4203-4291-9e90-0ee4c426e017.jpg?v=1571726525"},{"product_id":"helukabel-16-awg-18-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10674","title":"Helukabel 16 AWG 18 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10674","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e18,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e259,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e520,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10674\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133867638847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_86eb082b-30b0-43cc-a903-32e7d1377a1e.jpg?v=1571726526"},{"product_id":"helukabel-16-awg-19-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10675","title":"Helukabel 16 AWG 19 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10675","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e19 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e18,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e279,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e550,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133872422975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_eae6fb55-6216-4806-8a31-84a901949dcc.jpg?v=1571726529"},{"product_id":"helukabel-16-awg-2-cores-jz-600-without-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10656","title":"Helukabel 16 AWG 2 Cores JZ-600 Without GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10656","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e8,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e29,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e95,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10656\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133874028607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_746f74ba-c703-474e-8bbc-da885c2a514c.jpg?v=1571726530"},{"product_id":"helukabel-16-awg-20-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10676","title":"Helukabel 16 AWG 20 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10676","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e20 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e19,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e288,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e600,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10676\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133878911039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_761dbdfe-5ade-41e6-9fa4-96e5af6dabef.jpg?v=1571726532"},{"product_id":"helukabel-16-awg-21-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10677","title":"Helukabel 16 AWG 21 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10677","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e21 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e19,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e302,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e600,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10677\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133880320063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_87f10aa7-b448-49a9-9dde-c5f7cac53ce3.jpg?v=1571726533"},{"product_id":"helukabel-16-awg-25-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10678","title":"Helukabel 16 AWG 25 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10678","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e22,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e360,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e730,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10678\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133882515519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_6b51d4f3-4d6c-4ab5-ae2c-3bc83d9c119f.jpg?v=1571726534"},{"product_id":"helukabel-16-awg-3-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10657","title":"Helukabel 16 AWG 3 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10657","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e8,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e43,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e112,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10657\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133895393343,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_04740c73-8b38-4c45-8690-8633087c2829.jpg?v=1571726552"},{"product_id":"helukabel-16-awg-3-cores-jz-600-without-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10658","title":"Helukabel 16 AWG 3 Cores JZ-600 Without GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10658","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 x 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e8,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e43,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e112,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10658\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133895426111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_40590587-2605-4040-927c-da9ac10b8ac7.jpg?v=1571726552"},{"product_id":"helukabel-16-awg-32-cores-jz-600-with-gn-ye-conductor-flexible-number-coded-0-6-1kv-meter-marking-cable-10679","title":"Helukabel 16 AWG 32 Cores JZ-600 With GN-YE Conductor Flexible Number Coded 0,6\/1kV Meter Marking Cable 10679","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e • Special PVC control cable adapted to DIN VDE 0262 and DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51, with insulation wall thickness for 1 kV\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e\u003cbr\u003e • Flexing -15°C to +80°C \u003cbr\u003e • Fixed installation -40°C to +80°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal voltage:\u003c\/strong\u003e \u003cbr\u003e • U0\/U 0,6\/1 kV \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e\u003cbr\u003e • 4000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown voltage: \u003c\/strong\u003e\u003cbr\u003e • Min. 8000 V \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation resistance:\u003c\/strong\u003e \u003cbr\u003e • Min. 20 MOhm x km \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum bending radius:\u003c\/strong\u003e \u003cbr\u003e • Flexing 7,5x cable Ø \u003cbr\u003e • Fixed installation 4x cable Ø \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e\u003cbr\u003e • Up to 80x106 cJ\/kg (up to 80 Mrad) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5 \u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3 \u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering \u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer \u003cbr\u003e • Cores stranded in layers with optimal lay length \u003cbr\u003e • Outer sheath of special PVC compound type TM2 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1 \u003cbr\u003e • Sheath colour: black (RAL 9005) \u003cbr\u003e • With meter marking \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e \u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Informations\" \u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers \u003cbr\u003e • UV resistant \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests: \u003c\/strong\u003e\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e \u003cbr\u003e • G = with GN-YE conductor, x = without GN-YE conductor (OZ) \u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm². \u003cbr\u003e • Screened analogue type: JZ-600-Y-CY \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e\u003cbr\u003e • Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burria (suitable from an outer diameter of 18,0 mm for direct burial) or as underwater cable. The cores have been numbered in such a way that the numbers are easily identifiable, even if the cable has only been stripped back a few cm. The core numbers have been underlined to avoid confusion. The earth core is located in the outer layer. The black, special PVC outer sheath is resistant to the ultra violet radiation. Mainly used in South-European, Eastern and Arabian countries. = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e32 G 1,5\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e32 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e24,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n\u003ctd\u003e461,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n\u003ctd\u003e880,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10679\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133913874495,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-600_20Flexible_20Number_20Copper-LG_7cf2cd21-d6c0-47b0-82db-a5303e25ac84.jpg?v=1571726555"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/JZ-600_Flexible_Number_Copper-LG.jpg?v=1524641508","url":"https:\/\/www.nassauelectrical.com\/collections\/helukabel-jz-600-flexible-number-coded-bare-copper-conductor-0-6-1kv-meter-marking-cable.oembed?page=9","provider":"NassauElectrical","version":"1.0","type":"link"}