{"title":"Helukabel JZ-500 HMH-C Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable","description":"","products":[{"product_id":"helukabel-1-awg-3-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11801","title":"Helukabel 1 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11801","description":"\n    \n        \u003ctitle\u003eHelukabel 1 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11801\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 1 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11801. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH-C Without  GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 1 AWG 3 Cores, 11801.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e30,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e1675,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e3080,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11801\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130241859647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg.jpg?v=1571726394"},{"product_id":"helukabel-1-awg-4-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11802","title":"Helukabel 1 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11802","description":"\n    \n        \u003ctitle\u003eHelukabel 1 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11802\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 1 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11802. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH-C Without  GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 1 AWG 4 Cores, 11802.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e34,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e2155,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e3550,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11802\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130246873151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_c6670d34-2bab-4e9d-8c9c-e947df50c0b7.jpg?v=1571726395"},{"product_id":"helukabel-1-awg-5-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11803","title":"Helukabel 1 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11803","description":"\n    \n        \u003ctitle\u003eHelukabel 1 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11803\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 1 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11803. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH-C Without  GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 1 AWG 5 Cores, 11803.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e38,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e2794,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e4753,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11803\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130254082111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_2cdef9a6-933e-42b4-a485-fbde9093d570.jpg?v=1571726396"},{"product_id":"helukabel-10-awg-2-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11781","title":"Helukabel 10 AWG 2 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11781","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 2 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11781\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 2 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11781. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 10 AWG 2 Cores Cable, 10 AWG 2 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 10 AWG 2 Cores, 11781.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 G 6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e11,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e173,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e270,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11781\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130262372415,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_173ed0df-c325-417b-aab6-78ec7444f22b.jpg?v=1571726397"},{"product_id":"helukabel-10-awg-3-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11782","title":"Helukabel 10 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11782","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11782\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11782. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 10 AWG 3 Cores Cable, 10 AWG 3 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 10 AWG 3 Cores, 11782.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e12,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e240,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e328,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11782\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130267680831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_7a0d08ba-1090-440e-8477-d75f9d01f5c8.jpg?v=1571726398"},{"product_id":"helukabel-10-awg-4-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11783","title":"Helukabel 10 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11783","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11783\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11783. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 10 AWG 4 Cores Cable, 10 AWG 4 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 10 AWG 4 Cores, 11783.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e13,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e305,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e416,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11783\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130278920255,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_6d0935fe-e801-4ec1-bc3b-17cc245d9443.jpg?v=1571726400"},{"product_id":"helukabel-10-awg-5-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11784","title":"Helukabel 10 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11784","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11784\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11784. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 10 AWG 5 Cores Cable, 10 AWG 5 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 10 AWG 5 Cores, 11784.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e15,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e439,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e510,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11784\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130289504319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_d6d3f4cf-229f-4119-a520-d766332c0db3.jpg?v=1571726422"},{"product_id":"helukabel-10-awg-7-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11785","title":"Helukabel 10 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11785","description":"\n    \n        \u003ctitle\u003eHelukabel 10 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11785\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 10 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11785. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 10 AWG 7 Cores Cable, 10 AWG 7 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 10 AWG 7 Cores, 11785.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e17,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e505,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e670,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11785\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130297532479,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_77ee2a9d-b5af-4179-96f6-e0b7783761ed.jpg?v=1571726424"},{"product_id":"helukabel-12-awg-2-cores-jz-500-hmh-c-without-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11766","title":"Helukabel 12 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11766","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11766\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11766. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 12 AWG 2 Cores Cable, 12 AWG 2 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 12 AWG 2 Cores, 11766.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 x 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e10,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e120,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e184,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11766\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130313261119,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_6f2ae8fc-ff45-4ebd-ba0d-c3545f57b41d.jpg?v=1571726434"},{"product_id":"helukabel-12-awg-3-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11768","title":"Helukabel 12 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11768","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11766\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11768. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 12 AWG 3 Cores Cable, 12 AWG 3 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 12 AWG 3 Cores, 11768.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e10,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e174,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e238,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11768\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130315718719,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_d5b66a28-9272-410e-ae19-8a447f7c92ff.jpg?v=1571726436"},{"product_id":"helukabel-12-awg-4-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11769","title":"Helukabel 12 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11769","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11769\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11769. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 12 AWG 4 Cores Cable, 12 AWG 4 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 12 AWG 4 Cores, 11769.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e11,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e230,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e305,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11769\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133720936511,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_e6d5ed62-0e40-4162-937d-cd87a4bfebd3.jpg?v=1571726439"},{"product_id":"helukabel-12-awg-5-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11770","title":"Helukabel 12 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11770","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11770\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11770. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 12 AWG 5 Cores Cable, 12 AWG 5 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 12 AWG 5 Cores, 11770.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e12,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e273,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e388,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11770\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133733355583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_e5c8df10-b09c-40ed-a81b-d4c18c4b69d0.jpg?v=1571726442"},{"product_id":"helukabel-12-awg-7-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11771","title":"Helukabel 12 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11771","description":"\n    \n        \u003ctitle\u003eHelukabel 12 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11771\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 12 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11771. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 12 AWG 7 Cores Cable, 12 AWG 7 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 12 AWG 7 Cores, 11771.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e14,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e316,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e504,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11771\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133741285439,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_5c12c3e2-1629-40f6-87e8-2b136285a475.jpg?v=1571726445"},{"product_id":"helukabel-14-awg-12-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11751","title":"Helukabel 14 AWG 12 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11751","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 12 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11751\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 12 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11751. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 14 AWG 12 Cores Cable, 14 AWG 12 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 14 AWG 12, 11751.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e15,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e441,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e572,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11751\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133751279679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_a5c4fdc2-903f-4c50-b719-195628141ec9.jpg?v=1571726449"},{"product_id":"helukabel-14-awg-2-cores-jz-500-hmh-c-without-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11744","title":"Helukabel 14 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11744","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11744\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11744. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 14 AWG 2 Cores Cable, 14 AWG 2 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH-C Without  GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 14 AWG 2, 11733.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 x 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e8,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e96,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e132,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11744\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133778772031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_f090848c-51ef-411e-9007-618ad773a160.jpg?v=1571726462"},{"product_id":"helukabel-14-awg-3-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11745","title":"Helukabel 14 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11745","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11745\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11745. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 14 AWG 3 Cores Cable, 14 AWG 3 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 14 AWG 3, 11745.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e8,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e144,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e168,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11745\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133807116351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_5a32f602-c85f-43bf-ba74-38410238dfe7.jpg?v=1571726467"},{"product_id":"helukabel-14-awg-4-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11746","title":"Helukabel 14 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11746","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11746\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11746. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 14 AWG 4 Cores Cable, 14 AWG 4 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 14 AWG 4, 11746.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e9,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e148,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e195,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11746\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133828382783,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_e314ef94-18d1-49e3-9dd7-2a3b9c1b4e75.jpg?v=1571726472"},{"product_id":"helukabel-14-awg-5-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11747","title":"Helukabel 14 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11747","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11747\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11747. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 14 AWG 5 Cores Cable, 14 AWG 5 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 14 AWG 5, 11747.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e10,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e181,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e222,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11747\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133841784895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_69a1eb70-55f9-47fc-9fae-54c6da85a5b7.jpg?v=1571726497"},{"product_id":"helukabel-14-awg-7-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11748","title":"Helukabel 14 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11748","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11748\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11748. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 14 AWG 7 Cores Cable, 14 AWG 7 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 14 AWG 7, 11748.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e11,9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e255,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e345,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11748\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133847715903,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_8f078aa3-af47-4f38-9e1e-6d0f8d387b16.jpg?v=1571726501"},{"product_id":"helukabel-16-awg-12-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11729","title":"Helukabel 16 AWG 12 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11729","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 12 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11729\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 12 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11729. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 16 AWG 12 Cores Cable, 16 AWG 12 Cores Quote, 16 AWG 12 Cores JZ-500 HMH-C Cable, 16 AWG 12 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11729.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e12,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e267,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e340,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11729\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133860462655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_8c25173f-71f4-4942-af20-f91cfb5cb74b.jpg?v=1571726507"},{"product_id":"helukabel-16-awg-18-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11731","title":"Helukabel 16 AWG 18 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11731","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 18 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11731\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 18 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11731. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 16 AWG 18 Cores Cable, 16 AWG 18 Cores Quote, 16 AWG 18 Cores JZ-500 HMH-C Cable, 16 AWG 18 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11731.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e18 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e15,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e374,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e480,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11731\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133867442239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_9bc9b926-2370-45c4-92db-05f28c9107f0.jpg?v=1571726526"},{"product_id":"helukabel-16-awg-2-cores-jz-500-hmh-c-without-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11722","title":"Helukabel 16 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11722","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11722\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11722. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 16 AWG 2 Cores Cable, 16 AWG 2 Cores Quote, 16 AWG 2 Cores JZ-500 HMH-C Cable, 16 AWG 2 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH-C Without GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11722.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 x 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e7,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e63,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e88,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11722\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133873864767,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_788d1492-ec75-46d0-a88b-8d1b002fd361.jpg?v=1571726530"},{"product_id":"helukabel-16-awg-25-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11733","title":"Helukabel 16 AWG 25 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11733","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 25 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11733\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 25 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11733. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 16 AWG 25 Cores Cable, 16 AWG 25 Cores Quote, JZ-500 HMH-C Cable, JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 16 AWG 25 Cores, 11733.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e25 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e18,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e526,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e702,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11733\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133882318911,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_3f54d896-3203-4d38-8ad8-426fa139fc15.jpg?v=1571726534"},{"product_id":"helukabel-16-awg-3-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11723","title":"Helukabel 16 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11723","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11723\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11723. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 16 AWG 3 Cores Cable, 16 AWG 3 Cores Quote, 16 AWG 3 Cores JZ-500 HMH-C Cable, 16 AWG 3 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11723.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e7,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e80,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e100,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11723\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133893951551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_36c5164e-e3d8-4537-8d0b-d77fea1adc2a.jpg?v=1571726551"},{"product_id":"helukabel-16-awg-3-cores-jz-500-hmh-c-without-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11350","title":"Helukabel 16 AWG 3 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11350","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 3 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11350\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 3 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11350. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 16 AWG 3 Cores Cable, 16 AWG 3 Cores Quote, 16 AWG 3 Cores JZ-500 HMH-C Cable, 16 AWG 3 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH-C Without  GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11350.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 x 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e7,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e80,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e100,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11350\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133894475839,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_9628a2d2-3bd2-4e10-a11e-94fc27259b11.jpg?v=1571726551"},{"product_id":"helukabel-16-awg-4-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11724","title":"Helukabel 16 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11724","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11724\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11724. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 16 AWG 4 Cores Cable, 16 AWG 4 Cores Quote, 16 AWG 4 Cores JZ-500 HMH-C Cable, 16 AWG 4 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11724.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e8,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e97,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e125,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11724\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133924458559,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_e842d3bb-074d-4038-a37b-c8545fab8573.jpg?v=1571726558"},{"product_id":"helukabel-16-awg-5-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11725","title":"Helukabel 16 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11725","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11725\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11725. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 16 AWG 5 Cores Cable, 16 AWG 5 Cores Quote, 16 AWG 5 Cores JZ-500 HMH-C Cable, 16 AWG 5 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11725.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e9,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e119,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e158,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11725\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133952049215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_3697cb25-e49c-4445-9eb2-ebd5e2c66ff4.jpg?v=1571726569"},{"product_id":"helukabel-16-awg-7-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11726","title":"Helukabel 16 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11726","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11726\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11726. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 16 AWG 7 Cores Cable, 16 AWG 7 Cores Quote, 16 AWG 7 Cores JZ-500 HMH-C Cable, 16 AWG 7 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With  GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11726.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e9,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e147,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e210,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11726\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133978067007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_f51fd1ed-a953-4215-a351-95858cae394d.jpg?v=1571726575"},{"product_id":"helukabel-18-awg-12-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11707","title":"Helukabel 18 AWG 12 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11707","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 12 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11707\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 12 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11707. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 18 AWG 12 Cores Cable, 18 AWG 12 Cores Quote, 18 AWG 12 Cores JZ-500 HMH-C Cable, 18 AWG 12 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11707.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e11,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e184,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e260,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11707\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134005329983,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_dd51c9ff-f3f7-40da-9ff9-3b739d8821ec.jpg?v=1571726599"},{"product_id":"helukabel-18-awg-18-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11709","title":"Helukabel 18 AWG 18 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11709","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 18 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11709\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 18 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11709. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 18 AWG 18 Cores Cable, 18 AWG 18 Cores Quote, 18 AWG 18 Cores JZ-500 HMH-C Cable, 18 AWG 18 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11709.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e18 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e13,6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e260,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e382,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11709\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134015422527,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_995b939c-8880-4eb7-875a-448a547aba0e.jpg?v=1571726604"},{"product_id":"helukabel-18-awg-2-cores-jz-500-hmh-c-without-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11700","title":"Helukabel 18 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11700","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11700\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11700. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 18 AWG 2 Cores Cable, 18 AWG 2 Cores Quote, 18 AWG 2 Cores JZ-500 HMH-C Cable, 18 AWG 2 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH-C Without GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11700.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 x 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e6,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e50,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e66,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11700\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134172643391,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_ca66e5d0-3484-495d-a71d-fabe1b4d0c5e.jpg?v=1571726620"},{"product_id":"helukabel-18-awg-25-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11711","title":"Helukabel 18 AWG 25 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11711","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 25 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11711\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 25 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11711. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 18 AWG 25 Cores Cable, 18 AWG 25 Cores Quote, 18 AWG 25 Cores JZ-500 HMH-C Cable, 18 AWG 25 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11711.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e25 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e16,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e349,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e540,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11711\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134192533567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_7650e303-9516-4363-8c8f-b68180b8e3cf.jpg?v=1571726624"},{"product_id":"helukabel-18-awg-3-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11701","title":"Helukabel 18 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11701","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11701\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11701. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 18 AWG 3 Cores Cable, 18 AWG 3 Cores Quote, 18 AWG 3 Cores JZ-500 HMH-C Cable, 18 AWG 3 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11701.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e6,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e60,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e80,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11701\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134211211327,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_87a6681c-1302-4531-9c7f-664aa1f5167f.jpg?v=1571726627"},{"product_id":"helukabel-18-awg-3-cores-jz-500-hmh-c-without-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11348","title":"Helukabel 18 AWG 3 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11348","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 3 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11348\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 3 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11348. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 18 AWG 3 Cores Cable, 18 AWG 3 Cores Quote, 18 AWG 3 Cores JZ-500 HMH-C Cable, 18 AWG 3 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH-C Without GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11348.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 x 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e6,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e60,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e80,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11348\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134211244095,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_a351670c-7514-4c76-865b-764e88b19b73.jpg?v=1571726627"},{"product_id":"helukabel-18-awg-4-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11702","title":"Helukabel 18 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11702","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11702\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11702. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 18 AWG 4 Cores Cable, 18 AWG 4 Cores Quote, 18 AWG 4 Cores JZ-500 HMH-C Cable, 18 AWG 4 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11702.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e7,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e71,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e100,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11702\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134242635839,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_b7ecb5b1-785e-494d-ada4-e64525d95750.jpg?v=1571726644"},{"product_id":"helukabel-18-awg-4-cores-jz-500-hmh-c-without-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11349","title":"Helukabel 18 AWG 4 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11349","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 4 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11349\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 4 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11349. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 18 AWG 4 Cores Cable, 18 AWG 4 Cores Quote, 18 AWG 4 Cores JZ-500 HMH-C Cable, 18 AWG 4 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH-C Without GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11349.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 x 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e7,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e71,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e100,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11349\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134242734143,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_6a8d4638-b044-4bdf-9c27-648bb37cf2fa.jpg?v=1571726644"},{"product_id":"helukabel-18-awg-5-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11703","title":"Helukabel 18 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11703","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11703\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11703. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 18 AWG 5 Cores Cable, 18 AWG 5 Cores Quote, 18 AWG 5 Cores JZ-500 HMH-C Cable, 18 AWG 5 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11703.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e8,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e88,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e130,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11703\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134269636671,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_61b2ed2a-c691-4871-8c76-0a4ad120b8cd.jpg?v=1571726649"},{"product_id":"helukabel-18-awg-7-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11704","title":"Helukabel 18 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11704","description":"\n    \n        \u003ctitle\u003eHelukabel 18 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11704\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 18 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11704. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 18 AWG 7 Cores Cable, 18 AWG 7 Cores Quote, 18 AWG 7 Cores JZ-500 HMH-C Cable, 18 AWG 7 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11704.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e8,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e111,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e160,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11704\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134297915455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_c96d4e73-4f39-4b7f-a8d4-30676034dec6.jpg?v=1571726655"},{"product_id":"helukabel-19-awg-12-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11685","title":"Helukabel 19 AWG 12 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11685","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 12 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11685\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 12 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11685. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 19 AWG 12 Cores Cable, 19 AWG 12 Cores Quote, 19 AWG 12 Cores JZ-500 HMH-C Cable, 19 AWG 12 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11685.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e12 G 0,75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e10,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e142,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e203,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11685\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134327472191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_5417d681-b5fb-4170-bed0-a88bff4ac12d.jpg?v=1571726677"},{"product_id":"helukabel-19-awg-18-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11687","title":"Helukabel 19 AWG 18 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11687","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 18 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11687\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 18 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11687. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 19 AWG 18 Cores Cable, 19 AWG 18 Cores Quote, 19 AWG 18 Cores JZ-500 HMH-C Cable, 19 AWG 18 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11687.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e18 G 0,75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e12,7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e212,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e290,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11687\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134341398591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_6c35fc47-1291-42b9-ae7d-2b5156f28e84.jpg?v=1571726680"},{"product_id":"helukabel-19-awg-2-cores-jz-500-hmh-c-without-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11678","title":"Helukabel 19 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11678","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11678\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 2 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11678. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel Quote, 19 AWG 2 Cores Cable, 19 AWG 2 Cores Quote, 19 AWG 2 Cores JZ-500 HMH-C Cable, 19 AWG 2 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH  Without GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cable, Cu-Screened EMC-Preferred Type Cable, Cu-Screened EMC-Preferred Type Cable Price, Cu-Screened EMC-Preferred Type Cable Quote, 11678.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e2 x 0,75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e6,1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e40,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e60,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11678\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134349983807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_27ac56b8-c168-46cd-a40d-b8f305595017.jpg?v=1571726686"},{"product_id":"helukabel-19-awg-25-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11689","title":"Helukabel 19 AWG 25 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11689","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 25 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11689\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 25 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11689. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel  Quote, 19 AWG 25 Cores Cable, 19 AWG 25 Cores Quote, 19 AWG 25 Cores JZ-500 HMH-C Cable, 19 AWG 25 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11689.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e25 G 0,75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e15,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e281,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e413,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11689\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134373183551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_bc3d5ad7-cd2a-42f8-85f7-a5a004b47d64.jpg?v=1571726689"},{"product_id":"helukabel-19-awg-3-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11679","title":"Helukabel 19 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11679","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11679\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 3 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11679. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel Quote, 19 AWG 3 Cores Cable, 19 AWG 3 Cores Quote, 19 AWG 3 Cores JZ-500 HMH-C Cable, 19 AWG 3 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH  With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cable, Cu-Screened EMC-Preferred Type Cable, Cu-Screened EMC-Preferred Type Cable Price, Cu-Screened EMC-Preferred Type Cable Quote, 11679.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 G 0,75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e6,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e52,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e68,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11679\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134388256831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_172d8ee8-200c-41f5-86b8-477faf1a49ed.jpg?v=1571726692"},{"product_id":"helukabel-19-awg-3-cores-jz-500-hmh-c-without-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11344","title":"Helukabel 19 AWG 3 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11344","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 3 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11344\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 3 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11344. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel Quote, 19 AWG 3 Cores Cable, 19 AWG 3 Cores Quote, 19 AWG 3 Cores JZ-500 HMH-C Cable, 19 AWG 3 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH  Without GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cable, Cu-Screened EMC-Preferred Type Cable, Cu-Screened EMC-Preferred Type Cable Price, Cu-Screened EMC-Preferred Type Cable Quote, 11344.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e3 x 0,75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e6,3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e52,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e68,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11344\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134388289599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_f7157d89-5a67-4a79-bc32-b8dad5db58ae.jpg?v=1571726692"},{"product_id":"helukabel-19-awg-4-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11680","title":"Helukabel 19 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11680","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11680\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 4 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11680. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel Quote, 19 AWG 4 Cores Cable, 19 AWG 4 Cores Quote, 19 AWG 4 Cores JZ-500 HMH-C Cable, 19 AWG 4 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH  With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cable, Cu-Screened EMC-Preferred Type Cable, Cu-Screened EMC-Preferred Type Cable Price, Cu-Screened EMC-Preferred Type Cable Quote, 11680.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 0,75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e6,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e60,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e78,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11680\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134411423807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_48011796-a855-4411-a37a-479caff7b0db.jpg?v=1571726717"},{"product_id":"helukabel-19-awg-4-cores-jz-500-hmh-c-without-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11345","title":"Helukabel 19 AWG 4 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11345","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 4 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11345\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 4 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11345. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel Quote, 19 AWG 4 Cores Cable, 19 AWG 4 Cores Quote, 19 AWG 4 Cores JZ-500 HMH-C Cable, 19 AWG 4 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH-C Without GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11345.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 x 0,75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e6,8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e60,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e78,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11345\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134412439615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_595daf83-00e5-452d-b260-1b219f63f6d1.jpg?v=1571726717"},{"product_id":"helukabel-19-awg-5-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11681","title":"Helukabel 19 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11681","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11681\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 5 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11681. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel Quote, 19 AWG 5 Cores Cable, 19 AWG 5 Cores Quote, 19 AWG 5 Cores JZ-500 HMH-C Cable, 19 AWG 5 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11681.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 G 0,75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e7,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e71,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e95,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11681\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134428790847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_6b6a83bf-3b57-4377-9006-e09bb72534bc.jpg?v=1571726722"},{"product_id":"helukabel-19-awg-5-cores-jz-500-hmh-c-without-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11346","title":"Helukabel 19 AWG 5 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11346","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 5 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11346\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 5 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11346. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel Quote, 19 AWG 5 Cores Cable, 19 AWG 5 Cores Quote, 19 AWG 5 Cores JZ-500 HMH-C Cable, 19 AWG 5 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH-C Without GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11346.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e5 x 0,75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e7,4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e71,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e95,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11346\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134428889151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_14601273-5b1e-45ac-b8d3-d19c52df9225.jpg?v=1571726722"},{"product_id":"helukabel-19-awg-7-cores-jz-500-hmh-c-with-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11682","title":"Helukabel 19 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11682","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11682\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 7 Cores JZ-500 HMH-C With GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11682. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel Quote, 19 AWG 7 Cores Cable, 19 AWG 7 Cores Quote, 19 AWG 7 Cores JZ-500 HMH-C Cable, 19 AWG 7 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C With GN-YE Conductor Cable, JZ-500 HMH-C With GN-YE Conductor Price, JZ-500 HMH-C With GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11682.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 0,75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e8,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e91,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e130,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11682\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134449696831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_64b2f014-2463-484e-838d-a425f6ec6680.jpg?v=1571726727"},{"product_id":"helukabel-19-awg-7-cores-jz-500-hmh-c-without-gn-ye-conductor-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable-11347","title":"Helukabel 19 AWG 7 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11347","description":"\n    \n        \u003ctitle\u003eHelukabel 19 AWG 7 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11347\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 7 Cores JZ-500 HMH-C Without GN-YE Conductor Flexible Control Halogen Free Cu-Screened EMC-Preferred Type Cable 11347. Click for a free quote.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable, Helukabel Quote, 19 AWG 7 Cores Cable, 19 AWG 7 Cores Quote, 19 AWG 7 Cores JZ-500 HMH-C Cable, 19 AWG 7 Cores JZ-500 HMH-C Quote, JZ-500 HMH-C Without GN-YE Conductor Cable, JZ-500 HMH-C Without GN-YE Conductor Price, JZ-500 HMH-C Without GN-YE Conductor Quote, Halogen Free Cu-Screened EMC-Preferred Type Cable, Halogen Free Cu-Screened EMC-Preferred Type Cable Price, Halogen Free Cu-Screened EMC-Preferred Type Cable Quote, 11347.\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical data:\u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free core flexible control cable adapted to DIN VDE 0285-525-2-51\/DIN EN 50525-2-51 and DIN VDE 0285-525-3-11\/DIN EN 50525-3-11  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature range: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing -15°C to +70°C  \u003cbr\u003e\n        • Fixed installation -40°C to +70°C  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • U0\/U 300\/500 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest voltage: \u003c\/strong\u003e \u003cbr\u003e\n        • 2000 V  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCoupling resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Max. 250 Ohm\/km  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum bending radius: \u003c\/strong\u003e \u003cbr\u003e\n        • Flexing 12,5x cable Ø  \u003cbr\u003e\n        • Fixed installation 4x cable Ø  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation resistance: \u003c\/strong\u003e \u003cbr\u003e\n        • Up to 100x106 cJ\/kg (up to 100 Mrad)  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable structure: \u003c\/strong\u003e \u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5  \u003cbr\u003e\n        • Core insulation of halogen-free polymer compound type TI6 to DIN VDE 0207-363-7 \/ DIN EN 50363-7  \u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering  \u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer  \u003cbr\u003e\n        • Cores stranded in layers with optimal lay length  \u003cbr\u003e\n        • Separating foil  \u003cbr\u003e\n        • Tinned copper braided screen, approx. 85% coverage  \u003cbr\u003e\n        • Outer sheath of halogen-free polymer compound type TM7 to DIN VDE 0207-363-8 \/ DIN EN 50363-8  \u003cbr\u003e\n        • Sheath colour: grey (RAL 7001)  \u003cbr\u003e\n        • With meter marking  \u003cbr\u003e\n        • LS0H= Low Smoke Zero Halogen  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties: \u003c\/strong\u003e \u003cbr\u003e\n        • We recommend you for critical applications a consultation  \u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e  \u003cbr\u003e\n        • Flame test acc. to DIN VDE 0482-332-3-24, BS 4066 part 3, DIN EN 60332-3-24, IEC 60332-3-24 (previously DIN VDE 0472 part 804 test method C)  \u003cbr\u003e\n        • Self-extinguishing flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)  \u003cbr\u003e\n        • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)  \u003cbr\u003e\n        • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)  \u003cbr\u003e\n        • Smoke density acc. to DIN VDE 0482 part 1034-1+2, DIN EN 61034-1+2, IEC 61034-1+2, BS 7622 part 1+2  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote: \u003c\/strong\u003e \u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)  \u003cbr\u003e\n        • Clean room qualification tested with analog type. Please note \"clean room qualified\" when ordering.  \u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm²  \u003cbr\u003e\n        • Unscreened analogue type: JZ-500 HMH  \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication: \u003c\/strong\u003e \u003cbr\u003e\n        • Halogen-free, flame retardant control cables are used for instrumentation and control cables in tooling machinery, conveyor and transportation belts, production lines, in plant construction, air-conditioning systems as well as in iron and steel works. For fixed installation or for flexing applications, for casual, not constantly recurring free movement without forced motion and without tensile stress for medium mechanical loads. The cable is suitable for use in dry, damp and wet environments and on plaster. An interference-free transmission of signals and pulse in assured by the high degree of\n        screening. EMC = Electromagnetic compatibility To optimize the EMC features we recommend a large round contact of the copper braiding on both ends. = Product conforms with Low-Voltage Directive 2014\/35\/EU. \u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e19\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 x 0,75\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n                    \u003ctd\u003e8,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e91,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e130,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e11347\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134449729599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20HMHC_20Flexible_20Cont-_20lg_b222c1fc-a0ef-4612-8f26-ea48d3bfd381.jpg?v=1571726727"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/helukabel-jz-500-hmh-c-flexible-control-halogen-free-cu-screened-emc-preferred-type-cable.oembed?page=4","provider":"NassauElectrical","version":"1.0","type":"link"}