{"title":"Helukabel JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable","description":"","products":[{"product_id":"helukabel-10-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10796","title":"Helukabel 10 AWG 4 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10796","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e13,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e230,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e424,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10796\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130278821951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg.jpg?v=1571726400"},{"product_id":"helukabel-10-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10797","title":"Helukabel 10 AWG 5 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10797","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e14,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e288,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e525,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10797\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7130289471551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_cf54d8e8-645d-435a-9f72-8bf99530057f.jpg?v=1571726422"},{"product_id":"helukabel-14-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10787","title":"Helukabel 14 AWG 2 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10787","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 X 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e7,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e48,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e112,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10787\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133778706495,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_d1569791-ef0d-46b4-ad77-09f505c173e8.jpg?v=1571726462"},{"product_id":"helukabel-14-awg-3-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10788","title":"Helukabel 14 AWG 3 Cores 2.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10788","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e8,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e148,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133804265535,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_41ef9659-649b-40d2-99eb-370bdfd50ebe.jpg?v=1571726466"},{"product_id":"helukabel-14-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10789","title":"Helukabel 14 AWG 3 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10789","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 X 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e8,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e148,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133807050815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_7a69d911-64c4-46e6-a1a3-97176047e32b.jpg?v=1571726467"},{"product_id":"helukabel-14-awg-4-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10790","title":"Helukabel 14 AWG 4 Cores 2.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10790","description":"\n    \n        \u003ctitle\u003eHelukabel 14 AWG 4 Cores 2.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10790\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 14 AWG 4 Cores 2.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10790. Click for a free quote. 14 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 10790, 14 AWG 4 Cores 2.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10790, 10790, JZ-500 Cold Cable, Flexible Cable, Bare Copper Conductor Cable, Meter Marking Cable, Helukabel Cables, Special PVC Control Cable, Core PVC Insulation Cable, GN-YE Conductor Cable, JZ-500 Cable, JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • U0\/U 300\/500 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 8000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type YI4\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of cold flexible special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e\n        = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e4 G 2,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e96,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e178,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e10790\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133824581695,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_70d66212-7d83-4f9a-9407-47a8db483a2a.jpg?v=1571726470"},{"product_id":"helukabel-14-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10791","title":"Helukabel 14 AWG 4 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10791","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 X 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e9,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e96,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e178,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10791\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133828317247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_8d53400b-616c-4f83-9665-cb665f220cd8.jpg?v=1571726471"},{"product_id":"helukabel-14-awg-5-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10792","title":"Helukabel 14 AWG 5 Cores 2.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10792","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e10,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e120,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e221,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133840441407,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_9dbe075b-4097-4ac7-a500-f9c39da6a0dd.jpg?v=1571726496"},{"product_id":"helukabel-14-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10793","title":"Helukabel 14 AWG 5 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10793","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 X 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e10,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e120,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e221,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10793\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133841391679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_e7596119-f80a-4e88-8910-51e48ac17697.jpg?v=1571726497"},{"product_id":"helukabel-14-awg-7-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10794","title":"Helukabel 14 AWG 7 Cores 2.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10794","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e11,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e168,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e306,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133846896703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_231ad85d-9eac-42b2-8d9d-62b2f00ddd57.jpg?v=1571726500"},{"product_id":"helukabel-14-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10795","title":"Helukabel 14 AWG 7 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10795","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 X 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e11,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e168,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e306,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10795\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133847683135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_c75930c3-ad96-40f9-939a-339e44627b9d.jpg?v=1571726501"},{"product_id":"helukabel-16-awg-12-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10784","title":"Helukabel 16 AWG 12 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10784","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 X 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e11,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e173,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e309,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10784\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133860429887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_a5b1d909-e3b1-4ba7-ae43-30fca5cc7b35.jpg?v=1571726507"},{"product_id":"helukabel-16-awg-18-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10785","title":"Helukabel 16 AWG 18 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10785","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 X 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e14,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e259,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e440,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10785\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133867409471,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_8b2c9aa7-d2c6-4af7-aba2-d3573d419c79.jpg?v=1571726526"},{"product_id":"helukabel-16-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10774","title":"Helukabel 16 AWG 2 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10774","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 X 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e6,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e29,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e70,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10774\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133873799231,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_8d96647b-c67f-42b2-a1d7-745d20f30cc9.jpg?v=1571726530"},{"product_id":"helukabel-16-awg-25-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10786","title":"Helukabel 16 AWG 25 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10786","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 X 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e17,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e360,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e620,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10786\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133882220607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_74168dd5-ae31-4ff2-b814-d46d39373008.jpg?v=1571726534"},{"product_id":"helukabel-16-awg-3-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10775","title":"Helukabel 16 AWG 3 Cores 1.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10775","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e6,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e43,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e90,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10775\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133890543679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_3b3f9895-2e79-4f24-8c19-2e74c5861c1a.jpg?v=1571726551"},{"product_id":"helukabel-16-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10776","title":"Helukabel 16 AWG 3 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10776","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 X 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e6,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e43,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e90,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10776\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133893918783,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_a868e6f5-35f8-4e75-9b62-11632b0355c8.jpg?v=1571726551"},{"product_id":"helukabel-16-awg-4-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10777","title":"Helukabel 16 AWG 4 Cores 1.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10777","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e7,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e58,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e109,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10777\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133920886847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_4d45a373-262b-48b1-b27c-970c191ed5e9.jpg?v=1571726557"},{"product_id":"helukabel-16-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10778","title":"Helukabel 16 AWG 4 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10778","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 X 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e7,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e58,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e109,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10778\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133924360255,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_0e85eaf2-ba40-4e81-8a5f-c00cc58ec46f.jpg?v=1571726558"},{"product_id":"helukabel-16-awg-5-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10779","title":"Helukabel 16 AWG 5 Cores 1.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10779","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e8,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e131,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10779\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133949165631,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_cd8d8afe-26b1-46b5-8296-19b3ab169485.jpg?v=1571726569"},{"product_id":"helukabel-16-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10780","title":"Helukabel 16 AWG 5 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10780","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 X 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e8,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e131,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133951787071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_f022ed3c-832e-4de5-ae66-cf007008abf1.jpg?v=1571726569"},{"product_id":"helukabel-16-awg-6-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10781","title":"Helukabel 16 AWG 6 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10781","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e6 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e9,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e86,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e157,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10781\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133968924735,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_285f201e-b81c-4040-826f-3665648fe418.jpg?v=1571726573"},{"product_id":"helukabel-16-awg-7-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10782","title":"Helukabel 16 AWG 7 Cores 1.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10782","description":"\n    \n        \u003ctitle\u003eHelukabel 16 AWG 7 Cores 1.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10782\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 16 AWG 7 Cores 1.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10782. Click for a free quote. 16 AWG.\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Helukabel Cable Price, Helukabel Cable Quote, Helukabel Cable 10782, 16 AWG 7 Cores 1.5 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10782, 10782, JZ-500 Cold Cable, Flexible Cable, Bare Copper Conductor Cable, Meter Marking Cable, Helukabel Cables, Special PVC Control Cable, Core PVC Insulation Cable, GN-YE Conductor Cable, JZ-500 Cable, JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e\n        • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing -30°C to +80°C\u003cbr\u003e\n        • fixed installation -40°C to +80°C\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • U0\/U 300\/500 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • 4000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 8000 V\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • min. 20 MOhm x km\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e\n        • flexing 7,5x cable Ø\u003cbr\u003e\n        • fixed installation 4x cable Ø\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e\n        • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e\n        • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e\n        • Core insulation of special PVC compound type YI4\u003cbr\u003e\n        • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e\n        • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e\n        • Cores stranded in layers with optimal lay length\u003cbr\u003e\n        • Outer sheath of cold flexible special PVC\u003cbr\u003e\n        • Sheath colour: black (RAL 9005)\u003cbr\u003e\n        • With meter marking\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e\n        • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e\n        • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e\n        • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e\n        • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e\n        • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e\n        This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e\n        = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eawg-no.\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n                    \u003ctd\u003e7 G 1,5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n                    \u003ctd\u003e9,2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e101,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n                    \u003ctd\u003e184,0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ehelukabel part number\u003c\/td\u003e\n                    \u003ctd\u003e10782\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133976068159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_0b0583bb-5c3b-42be-bd20-9c261d66e983.jpg?v=1571726575"},{"product_id":"helukabel-16-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10783","title":"Helukabel 16 AWG 7 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10783","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 X 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e9,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e101,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e184,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10783\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133977968703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_dd41b242-89bd-4961-81a0-e3392441ec7e.jpg?v=1571726575"},{"product_id":"helukabel-18-awg-12-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10771","title":"Helukabel 18 AWG 12 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10771","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e10,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e115,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e230,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10771\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134005264447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_1dfb5c56-7737-411d-bbd6-6807b270efe5.jpg?v=1571726599"},{"product_id":"helukabel-18-awg-18-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10772","title":"Helukabel 18 AWG 18 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10772","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e12,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e173,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e343,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10772\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134015356991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_53a0303a-c0c8-4e9e-8065-39f938336876.jpg?v=1571726604"},{"product_id":"helukabel-18-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10762","title":"Helukabel 18 AWG 2 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10762","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 X 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e5,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e19,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e60,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10762\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134172577855,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_f1be11d2-ec34-4a46-bce5-e72426cf508e.jpg?v=1571726620"},{"product_id":"helukabel-18-awg-25-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10773","title":"Helukabel 18 AWG 25 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10773","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 X 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e15,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e240,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e485,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10773\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134192402495,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_00ace028-1ce2-48b2-8c43-b6d4c9eec0ce.jpg?v=1571726624"},{"product_id":"helukabel-18-awg-3-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10763","title":"Helukabel 18 AWG 3 Cores 1 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10763","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e5,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e29,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134206885951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_ac504904-09b6-4bc7-b0f0-29f47980b852.jpg?v=1571726626"},{"product_id":"helukabel-18-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10764","title":"Helukabel 18 AWG 3 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10764","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 X 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e5,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e29,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10764\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134211145791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_7093f0fb-ad54-4bbd-8f16-23c6731d7b5d.jpg?v=1571726627"},{"product_id":"helukabel-18-awg-4-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10765","title":"Helukabel 18 AWG 4 Cores 1 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10765","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e6,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e38,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e86,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10765\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134239719487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_a78da3b5-69d5-4c5f-8a71-b01fc134b3da.jpg?v=1571726643"},{"product_id":"helukabel-18-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10766","title":"Helukabel 18 AWG 4 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10766","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 X 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e6,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e38,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e86,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10766\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134242537535,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_7309e0fc-833e-45e2-9b79-4c4ea4ca98f0.jpg?v=1571726644"},{"product_id":"helukabel-18-awg-5-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10767","title":"Helukabel 18 AWG 5 Cores 1 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10767","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e7,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e48,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e104,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10767\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134267539519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_ea6dd778-d1c7-4c61-9dfc-2127293ec7d9.jpg?v=1571726649"},{"product_id":"helukabel-18-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10768","title":"Helukabel 18 AWG 5 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10768","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 X 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e7,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e48,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e104,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10768\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134269571135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_11821751-47c1-439e-8b9d-1c446c8d7245.jpg?v=1571726649"},{"product_id":"helukabel-18-awg-7-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10769","title":"Helukabel 18 AWG 7 Cores 1 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10769","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e8,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e67,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e141,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10769\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134294409279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_c258baf3-fed4-4b90-8bc9-90ad2d4a122f.jpg?v=1571726655"},{"product_id":"helukabel-18-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10770","title":"Helukabel 18 AWG 7 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10770","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 X 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e8,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e67,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e141,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10770\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134297849919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_5b03f371-1d21-4c28-90a3-abd5b7fed70a.jpg?v=1571726655"},{"product_id":"helukabel-19-awg-12-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10759","title":"Helukabel 19 AWG 12 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10759","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 G 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e9,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e86,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e179,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10759\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134327439423,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_001bc19a-f7fd-4983-82b9-30b2d92bb400.jpg?v=1571726677"},{"product_id":"helukabel-19-awg-18-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10760","title":"Helukabel 19 AWG 18 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10760","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 X 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e12,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e130,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e257,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134339989567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_42ff68c0-3ccd-4512-83ba-ee930a062cc5.jpg?v=1571726680"},{"product_id":"helukabel-19-awg-25-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10761","title":"Helukabel 19 AWG 25 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10761","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 X 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e14,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e180,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e365,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10761\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134373118015,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_72b99a44-4921-49cb-bf2b-f54f608b2118.jpg?v=1571726689"},{"product_id":"helukabel-19-awg-3-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10751","title":"Helukabel 19 AWG 3 Cores 0.75 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10751","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e5,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e21,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e54,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10751\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134385537087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_b8ecf10e-c426-4f85-be3b-1a6945fea7b6.jpg?v=1571726691"},{"product_id":"helukabel-19-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10752","title":"Helukabel 19 AWG 3 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10752","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 X 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e5,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e21,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e54,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10752\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134388060223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_af17c340-352c-4336-9f99-01cf524ab7e7.jpg?v=1571726692"},{"product_id":"helukabel-19-awg-4-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10753","title":"Helukabel 19 AWG 4 Cores 0.75 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10753","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e6,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e28,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e66,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10753\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134408704063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_447fc5ff-f243-40a8-8394-7cbcefbfff5d.jpg?v=1571726716"},{"product_id":"helukabel-19-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10754","title":"Helukabel 19 AWG 4 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10754","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 X 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e6,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e29,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e66,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10754\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134411391039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_46c31b53-011a-4565-96a3-6f778833ed99.jpg?v=1571726717"},{"product_id":"helukabel-19-awg-5-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10755","title":"Helukabel 19 AWG 5 Cores 0.75 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10755","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e6,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e36,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e80,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10755\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134426136639,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_ae69f0c7-36f6-4637-be5c-cf01a6641f76.jpg?v=1571726721"},{"product_id":"helukabel-19-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10756","title":"Helukabel 19 AWG 5 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10756","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 X 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e6,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e36,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e80,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10756\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134428495935,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_3deb98e5-2646-4307-a8d2-c89706403fb5.jpg?v=1571726722"},{"product_id":"helukabel-19-awg-7-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10757","title":"Helukabel 19 AWG 7 Cores 0.75 mm² Cross-Sec. JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10757","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e7,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e50,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e110,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10757\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134446944319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_1bcfd5e9-2067-473c-9783-6817e8e4bcf3.jpg?v=1571726726"},{"product_id":"helukabel-19-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10758","title":"Helukabel 19 AWG 7 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10758","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 X 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e7,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e50,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e110,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10758\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134449664063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_1de660b2-9f73-4d92-8bab-fb82a029a95a.jpg?v=1571726727"},{"product_id":"helukabel-20-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable-10750","title":"Helukabel 20 AWG 2 Cores JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable 10750","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 X 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. - mm\u003c\/td\u003e\n\u003ctd\u003e4,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e9,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e40,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e10750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7147933794367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_20Cold_20Flexible_20Copper_20Cable-lg_2788e831-f406-427d-aa01-14cb215055b1.jpg?v=1571726782"},{"product_id":"helukabel-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable","title":"Helukabel JZ-500 Cold Flexible At Low Temperature Number Coded Bare Copper Conductor Meter Marking Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Special-PVC control cable adapted to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -30°C to +80°C\u003cbr\u003e • fixed installation -40°C to +80°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e:\u003cbr\u003e • U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e:\u003cbr\u003e • 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e:\u003cbr\u003e • min. 8000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper conductor, to DIN VDE 0295 cl.5, fine wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type YI4\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath of cold flexible special PVC\u003cbr\u003e • Sheath colour: black (RAL 9005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • Extensively oil resistant, oil-\/chemical resistance see \"Technical Infromations\"\u003cbr\u003e • The materials used during manufacturing are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with GN-YE conductor x = without GN-YE conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e This cold-flexible PVC hose cable is used under average stress for flexible applications with free movement, without tensile load and without forced motion guide in dry, moist, wet rooms and outside, as measuring and control cable at machine tools, conveyor belts and transport belts, production streets, in plant construction, in air condition construction and in refrigerated warehouses. Selected PVC mixtures guarantee good flexibility, efficient and fast installation.\u003cbr\u003e = Product conforms with Low-Voltage Directive 2014\/35\/EU.\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003eno.cores x \u003cbr\u003e cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003eweight \u003cbr\u003e app. kg\/km\u003c\/td\u003e\n\u003ctd\u003ehelukabel \u003cbr\u003e part number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-20-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e20\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 X 0,5\u003c\/td\u003e\n\u003ctd\u003e40,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-20-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10750\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-20-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-3-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 G 0,75\u003c\/td\u003e\n\u003ctd\u003e54,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-3-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare\"\u003e10751\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-3-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 X 0,75\u003c\/td\u003e\n\u003ctd\u003e54,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10752\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-4-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 G 0,75\u003c\/td\u003e\n\u003ctd\u003e66,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-4-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare\"\u003e10753\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-4-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 X 0,75\u003c\/td\u003e\n\u003ctd\u003e66,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10754\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-5-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 G 0,75\u003c\/td\u003e\n\u003ctd\u003e80,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-5-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare\"\u003e10755\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-5-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 X 0,75\u003c\/td\u003e\n\u003ctd\u003e80,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10756\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-7-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7 G 0,75\u003c\/td\u003e\n\u003ctd\u003e110,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-7-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare\"\u003e10757\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-7-cores-0-75-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7 X 0,75\u003c\/td\u003e\n\u003ctd\u003e110,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10758\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-12-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12 G 0,75\u003c\/td\u003e\n\u003ctd\u003e179,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-12-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e10759\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-12-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-18-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e18 G 0,75\u003c\/td\u003e\n\u003ctd\u003e257,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-18-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e10760\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-18-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-25-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e19\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e25 G 0,75\u003c\/td\u003e\n\u003ctd\u003e365,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-25-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e10761\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-19-awg-25-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 X 1\u003c\/td\u003e\n\u003ctd\u003e60,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10762\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-3-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-co\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 G 1\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-3-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-co\"\u003e10763\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-3-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-co\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 X 1\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10764\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-4-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-co\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 G 1\u003c\/td\u003e\n\u003ctd\u003e86,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-4-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-co\"\u003e10765\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-4-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-co\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 X 1\u003c\/td\u003e\n\u003ctd\u003e86,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10766\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-5-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-co\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 G 1\u003c\/td\u003e\n\u003ctd\u003e104,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-5-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-co\"\u003e10767\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-5-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-co\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 X 1\u003c\/td\u003e\n\u003ctd\u003e104,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10768\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-7-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-co\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7 G 1\u003c\/td\u003e\n\u003ctd\u003e141,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-7-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-co\"\u003e10769\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-7-cores-1-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-co\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7 X 1\u003c\/td\u003e\n\u003ctd\u003e141,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10770\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-12-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12 G 1\u003c\/td\u003e\n\u003ctd\u003e230,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-12-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e10771\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-12-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-18-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e18 X 1\u003c\/td\u003e\n\u003ctd\u003e343,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-18-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e10772\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-18-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-25-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e25 G 1\u003c\/td\u003e\n\u003ctd\u003e485,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-25-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e10773\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-18-awg-25-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 X 1,5\u003c\/td\u003e\n\u003ctd\u003e70,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10774\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-3-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 G 1,5\u003c\/td\u003e\n\u003ctd\u003e90,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-3-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e10775\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-3-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 X 1,5\u003c\/td\u003e\n\u003ctd\u003e90,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10776\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-4-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 G 1,5\u003c\/td\u003e\n\u003ctd\u003e109,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-4-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e10777\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-4-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 X 1,5\u003c\/td\u003e\n\u003ctd\u003e109,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10778\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-5-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 G 1,5\u003c\/td\u003e\n\u003ctd\u003e131,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-5-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e10779\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-5-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 X 1,5\u003c\/td\u003e\n\u003ctd\u003e131,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10780\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-6-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6 G 1,5\u003c\/td\u003e\n\u003ctd\u003e157,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-6-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10781\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-6-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-7-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7 G 1,5\u003c\/td\u003e\n\u003ctd\u003e184,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-7-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e10782\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-7-cores-1-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7 X 1,5\u003c\/td\u003e\n\u003ctd\u003e184,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10783\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-12-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12 G 1,5\u003c\/td\u003e\n\u003ctd\u003e309,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-12-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e10784\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-12-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-18-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e18 G 1,5\u003c\/td\u003e\n\u003ctd\u003e440,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-18-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e10785\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-18-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-25-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e25 G 1,5\u003c\/td\u003e\n\u003ctd\u003e620,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-25-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003e10786\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-16-awg-25-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2 X 2,5\u003c\/td\u003e\n\u003ctd\u003e112,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10787\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-2-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-3-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 G 2,5\u003c\/td\u003e\n\u003ctd\u003e148,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-3-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e10788\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-3-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3 X 2,5\u003c\/td\u003e\n\u003ctd\u003e148,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10789\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-3-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-4-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 G 2,5\u003c\/td\u003e\n\u003ctd\u003e178,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-4-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e10790\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-4-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 X 2,5\u003c\/td\u003e\n\u003ctd\u003e178,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10791\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-5-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 G 2,5\u003c\/td\u003e\n\u003ctd\u003e221,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-5-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e10792\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-5-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 X 2,5\u003c\/td\u003e\n\u003ctd\u003e221,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10793\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-7-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7 G 2,5\u003c\/td\u003e\n\u003ctd\u003e306,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-7-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003e10794\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-7-cores-2-5-mm-cross-sec-jz-500-cold-flexible-at-low-temperature-number-coded-bare-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e14\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e7 X 2,5\u003c\/td\u003e\n\u003ctd\u003e306,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10795\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-14-awg-7-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-10-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4 G 6\u003c\/td\u003e\n\u003ctd\u003e424,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-10-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10796\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-10-awg-4-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-10-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5 G 6\u003c\/td\u003e\n\u003ctd\u003e525,0\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-10-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003e10797\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/helukabel-cables\/flexible-control-cables\/pvc-control-cables\/helukabel-10-awg-5-cores-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-\"\u003eRequest A Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7449419382847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/JZ-500_Cold_Flexible_Copper_Cable-lg.jpg?v=1571729626"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/JZ-500_Cold_Flexible_Copper_Cable-lg.jpg?v=1524634876","url":"https:\/\/www.nassauelectrical.com\/collections\/helukabel-jz-500-cold-flexible-at-low-temperature-number-coded-bare-copper-conductor-meter-marking-cable.oembed?page=3","provider":"NassauElectrical","version":"1.0","type":"link"}