{"title":"Helukabel H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable","description":"","products":[{"product_id":"helukabel-14-awg-12-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13054","title":"Helukabel 14 AWG 12 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13054","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e16,8 - 20.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e288,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e543,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13054\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133751148607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg.jpg?v=1571726449"},{"product_id":"helukabel-14-awg-14-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13946","title":"Helukabel 14 AWG 14 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13946","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e14 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e17,8 - 20.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e336,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e611,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13946\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133763698751,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_27465dc9-4b8b-4730-8c96-1a0dc1555938.jpg?v=1571726459"},{"product_id":"helukabel-14-awg-18-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13055","title":"Helukabel 14 AWG 18 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13055","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e2021 - 24.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e432,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e787,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133766647871,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_6630b120-d7a2-40e9-8788-037aa5b55278.jpg?v=1571726460"},{"product_id":"helukabel-14-awg-2-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13943","title":"Helukabel 14 AWG 2 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13943","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 X 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e8,4 - 10.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e48,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e110,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13943\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133778083903,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_63c51885-d090-40ff-8f00-3f546faa9155.jpg?v=1571726462"},{"product_id":"helukabel-14-awg-25-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13056","title":"Helukabel 14 AWG 25 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13056","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e24,2 - 29.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e600,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e1175,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13056\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133791289407,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_6266e879-d91b-4cf5-8a2c-13da25dfaa4f.jpg?v=1571726465"},{"product_id":"helukabel-14-awg-27-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13947","title":"Helukabel 14 AWG 27 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13947","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e27 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e24,7 - 30.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e648,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e1280,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13947\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133803741247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_5514bba9-59cc-4392-af0b-6852b165e118.jpg?v=1571726466"},{"product_id":"helukabel-14-awg-3-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13050","title":"Helukabel 14 AWG 3 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13050","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e9,2 - 11.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e154,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133805772863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_20a71766-9f24-4085-97e5-937a59cb91e4.jpg?v=1571726467"},{"product_id":"helukabel-14-awg-34-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13057","title":"Helukabel 14 AWG 34 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13057","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e34 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e28,2 - 34.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e816,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e1529,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13057\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133822648383,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_fafd92f3-d3bc-4f48-88e2-334393b676af.jpg?v=1571726470"},{"product_id":"helukabel-14-awg-36-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13948","title":"Helukabel 14 AWG 36 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13948","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e36 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e28,0 - 34.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e864,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e1791,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13948\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133823598655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_87100585-e805-433f-ab9d-979d47d6418b.jpg?v=1571726470"},{"product_id":"helukabel-14-awg-4-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13051","title":"Helukabel 14 AWG 4 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13051","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e10,1 - 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e96,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e212,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13051\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133827170367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_b38f2b18-0cf0-4ed5-b498-1159f9d2789a.jpg?v=1571726471"},{"product_id":"helukabel-14-awg-41-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13949","title":"Helukabel 14 AWG 41 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13949","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e41 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e30,4 - 37.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e984,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e1905,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13949\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133840179263,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_ed1b5d4e-7254-402b-be42-5602cf138c75.jpg?v=1571726496"},{"product_id":"helukabel-14-awg-5-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13052","title":"Helukabel 14 AWG 5 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13052","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e11,2 - 13.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e120,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e242,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13052\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133840900159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_74edb8e4-64f1-46d5-8867-8b9b2b0e62f8.jpg?v=1571726496"},{"product_id":"helukabel-14-awg-50-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13058","title":"Helukabel 14 AWG 50 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13058","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e50 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e33,0 - 40.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e1200,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e2290,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13058\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133845880895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_d50e752b-fd6f-4d18-bad7-a94e202a1009.jpg?v=1571726500"},{"product_id":"helukabel-14-awg-61-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13059","title":"Helukabel 14 AWG 61 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13059","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e61 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e35,0 - 42.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e1464,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e2724,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13059\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133846667327,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_1d7aa14d-c2de-47bd-8bbd-f19fa197e564.jpg?v=1571726500"},{"product_id":"helukabel-14-awg-7-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13053","title":"Helukabel 14 AWG 7 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13053","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e13,6 - 16.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e168,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e350,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13053\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133847420991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_8106c946-1b43-4668-b898-41bd06df2b2a.jpg?v=1571726501"},{"product_id":"helukabel-14-awg-8-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13945","title":"Helukabel 14 AWG 8 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13945","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e8 G 2,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e14,9 - 18.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e192,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e379,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13945\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133852991551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_4aa7c471-89dd-4b09-8d02-cd6916a3488e.jpg?v=1571726503"},{"product_id":"helukabel-16-awg-12-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13043","title":"Helukabel 16 AWG 12 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13043","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e13,8 - 17.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e173,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e324,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13043\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133860266047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_c0013355-f83f-48eb-ab8f-0e55eb748e2f.jpg?v=1571726507"},{"product_id":"helukabel-16-awg-14-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13121","title":"Helukabel 16 AWG 14 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13121","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e14 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e14,7 - 18.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e202,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e372,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133864493119,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_c555f82a-db96-430a-ba7c-e45244fb9ab5.jpg?v=1571726510"},{"product_id":"helukabel-16-awg-18-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13044","title":"Helukabel 16 AWG 18 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13044","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e16,5 - 20.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e259,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e485,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13044\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133867278399,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_fc8f535f-3880-4a0d-b286-7c3ba793e529.jpg?v=1571726526"},{"product_id":"helukabel-16-awg-19-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13938","title":"Helukabel 16 AWG 19 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13938","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e19 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e16,7 - 20.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e274,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e495,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13938\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133872291903,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_1123a3ab-eb5e-4fb4-b307-0a2c8bb65a37.jpg?v=1571726529"},{"product_id":"helukabel-16-awg-2-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13120","title":"Helukabel 16 AWG 2 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13120","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 X 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e6,8 - 8.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e29,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e77,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133873569855,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_6419d702-90a3-4e05-a4b8-2d17253c21b1.jpg?v=1571726529"},{"product_id":"helukabel-16-awg-25-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13045","title":"Helukabel 16 AWG 25 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13045","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e19,9 - 24.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e360,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e671,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133882089535,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_f1b96a31-9c7f-4e1c-a9db-c70e4ae6d47f.jpg?v=1571726534"},{"product_id":"helukabel-16-awg-27-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13939","title":"Helukabel 16 AWG 27 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13939","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e27 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e20,3 - 24.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e389,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e695,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13939\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133888839743,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_2599e87c-f21f-45e9-aec8-3083f31a50a6.jpg?v=1571726537"},{"product_id":"helukabel-16-awg-3-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13037","title":"Helukabel 16 AWG 3 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13037","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e7,4 - 9.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e43,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e97,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133892739135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_f7a0f68f-46c3-4b56-bb11-08c39f1a16b3.jpg?v=1571726551"},{"product_id":"helukabel-16-awg-32-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13046","title":"Helukabel 16 AWG 32 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13046","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e32 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e22,2 - 27.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e461,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e820,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13046\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133913776191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_b3d9b0ca-2193-498e-bfb7-2219bba44e8f.jpg?v=1571726555"},{"product_id":"helukabel-16-awg-34-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13047","title":"Helukabel 16 AWG 34 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13047","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e34 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e23,0 - 28.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e490,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e881,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13047\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133914726463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_9cf4a48e-a38a-4310-9558-fa9c6d21b2ca.jpg?v=1571726555"},{"product_id":"helukabel-16-awg-36-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13940","title":"Helukabel 16 AWG 36 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13940","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e36 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e23,0 - 28,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e518,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e905,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133919281215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_d2607c86-16b9-4a0b-b234-d61727b09ee5.jpg?v=1571726556"},{"product_id":"helukabel-16-awg-37-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13941","title":"Helukabel 16 AWG 37 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13941","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e37 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e23,0 - 28.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e532,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e920,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13941\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133920264255,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_3889706b-183b-40e1-9818-125a78a94fcb.jpg?v=1571726557"},{"product_id":"helukabel-16-awg-4-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13038","title":"Helukabel 16 AWG 4 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13038","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e8,2 - 10.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e58,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e128,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13038\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133923278911,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_fa3b7542-97bd-4f93-94ac-134175bb07c1.jpg?v=1571726558"},{"product_id":"helukabel-16-awg-41-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13128","title":"Helukabel 16 AWG 41 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13128","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e41 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e25,2 - 30.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e590,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e1085,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133943660607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_7f64870a-7e78-4f00-8cde-14874ea9a529.jpg?v=1571726568"},{"product_id":"helukabel-16-awg-5-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13039","title":"Helukabel 16 AWG 5 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13039","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e9,1 - 11.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e149,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13039\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133950443583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_2398c259-2f2e-43e6-a09b-5aeb2f1f52f9.jpg?v=1571726569"},{"product_id":"helukabel-16-awg-50-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13048","title":"Helukabel 16 AWG 50 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13048","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e50 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e27,7 - 33.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e720,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e1381,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13048\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133965058111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_cce53226-f902-435f-a152-14509d47d04a.jpg?v=1571726572"},{"product_id":"helukabel-16-awg-6-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13040","title":"Helukabel 16 AWG 6 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13040","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e6 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e10,2 - 12.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e86,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e196,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133968826431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_9b11acd3-8f09-4531-89d9-1fa83325ecce.jpg?v=1571726573"},{"product_id":"helukabel-16-awg-61-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13049","title":"Helukabel 16 AWG 61 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13049","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e61 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e29,4 - 35.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e878,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e1640,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133972103231,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_43978d8e-623f-4d5f-9514-09d6ddd69cc0.jpg?v=1571726574"},{"product_id":"helukabel-16-awg-65-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13942","title":"Helukabel 16 AWG 65 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13942","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e65 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e30,3 - 37.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e963,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e1730,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13942\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133974888511,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_f89856e8-7dcd-4806-ad90-7de39988416b.jpg?v=1571726574"},{"product_id":"helukabel-16-awg-7-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13041","title":"Helukabel 16 AWG 7 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13041","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e11,3 - 14.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e101,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e216,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13041\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133977215039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_bd43538d-8ee3-4c6c-b739-0a474d74cf92.jpg?v=1571726575"},{"product_id":"helukabel-16-awg-8-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13937","title":"Helukabel 16 AWG 8 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13937","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e8 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e12,2 - 15.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e115,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e271,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13937\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133989437503,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_76c9105e-c48d-4d82-8c0e-fd1409021551.jpg?v=1571726578"},{"product_id":"helukabel-16-awg-9-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13042","title":"Helukabel 16 AWG 9 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13042","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e9 G 1,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e13,3 - 16.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e130,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e282,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13042\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7133993369663,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_f4adf08d-5257-4a4f-b7e2-e52ea48cf4b7.jpg?v=1571726592"},{"product_id":"helukabel-18-awg-12-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13031","title":"Helukabel 18 AWG 12 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13031","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e11,8 - 14.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e115,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e269,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13031\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134005035071,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_51a42d40-2cac-4d5e-a488-1b20dd9ea46f.jpg?v=1571726599"},{"product_id":"helukabel-18-awg-14-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13932","title":"Helukabel 18 AWG 14 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13932","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e14 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e12,6 - 14.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e134,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e361,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13932\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134011097151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_1ef2eb96-a997-440b-a39b-2fd592d98c8e.jpg?v=1571726601"},{"product_id":"helukabel-18-awg-18-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13032","title":"Helukabel 18 AWG 18 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13032","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e14,0 - 17.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e173,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e400,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13032\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134015225919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_498918ab-e99a-4af3-a639-7ea531700249.jpg?v=1571726603"},{"product_id":"helukabel-18-awg-19-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13933","title":"Helukabel 18 AWG 19 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13933","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e19 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e13,6 - 16.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e183,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e413,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13933\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134168743999,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_f5f4dc81-1240-4c51-bb2c-09208a87aa60.jpg?v=1571726619"},{"product_id":"helukabel-18-awg-2-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13119","title":"Helukabel 18 AWG 2 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13119","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 X 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e5,9 - 7.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e19,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e66,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13119\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134172282943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_072ae6c9-88c1-449a-b45a-b0b9df513144.jpg?v=1571726620"},{"product_id":"helukabel-18-awg-25-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13033","title":"Helukabel 18 AWG 25 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13033","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e16,9 - 20.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e240,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e546,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134192042047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_5f5beb9f-5ac0-413d-97c4-b9207a4890e1.jpg?v=1571726624"},{"product_id":"helukabel-18-awg-27-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13934","title":"Helukabel 18 AWG 27 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13934","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e27 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e17,0 - 21.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e259,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e582,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13934\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134204493887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_da190dde-f10c-4611-b73e-7f674cbe8d37.jpg?v=1571726626"},{"product_id":"helukabel-18-awg-3-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13025","title":"Helukabel 18 AWG 3 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13025","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e6,3 - 8.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e29,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e78,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134209245247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_b6c47c06-2688-44d1-b6e4-5638e92f9152.jpg?v=1571726627"},{"product_id":"helukabel-18-awg-34-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13034","title":"Helukabel 18 AWG 34 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13034","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e34 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e19,7 - 24.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e326,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e724,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13034\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134231068735,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_8ee86226-7964-4f20-b3ba-6242c7ef8b57.jpg?v=1571726630"},{"product_id":"helukabel-18-awg-36-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13124","title":"Helukabel 18 AWG 36 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13124","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e36 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e19,4 - 23.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e348,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e775,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134235787327,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_249d121c-79d3-4088-9492-c24894aa6805.jpg?v=1571726632"},{"product_id":"helukabel-18-awg-37-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13935","title":"Helukabel 18 AWG 37 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13935","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e37 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e19,4 - 23.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e355,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e785,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13935\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134237360191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_78807072-ac52-4f1a-b865-4a9370b502d9.jpg?v=1571726632"},{"product_id":"helukabel-18-awg-4-cores-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable-13026","title":"Helukabel 18 AWG 4 Cores H05VV5-F NYSLYÖ-JZ Flexible Number Coded Oil Resistant Bare Copper Conductor Meter Marking Cable 13026","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data\u003c\/strong\u003e:\u003cbr\u003e • Spezial-PVC control cable with oil resistant outer sheath acc. to DIN VDE 0285-525-2-51 \/ DIN EN 50525-2-51 and IEC 60227\/75\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e:\u003cbr\u003e • flexing -5°C to +70°C\u003cbr\u003e • fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNominal Voltage\u003c\/strong\u003e: U0\/U 300\/500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage\u003c\/strong\u003e: 2 kV, 5 minutes\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBreakdown Voltage\u003c\/strong\u003e: min. 4000 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance\u003c\/strong\u003e:\u003cbr\u003e • min. 20 MOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius\u003c\/strong\u003e:\u003cbr\u003e • flexing 7,5x cable Ø\u003cbr\u003e • fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance\u003c\/strong\u003e:\u003cbr\u003e • up to 80x106 cJ\/kg (up to 80 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure\u003c\/strong\u003e:\u003cbr\u003e • Bare copper-conductor, to DIN VDE 0295 cl.5, fine-wire, BS 6360 cl.5, IEC 60228 cl.5\u003cbr\u003e • Core insulation of special PVC compound type TI2 to DIN VDE 0207-363-3 \/ DIN EN 50363-3\u003cbr\u003e • Core identification to DIN VDE 0293 black cores with continuous white numbering\u003cbr\u003e • GN-YE conductor, 3 cores and above in the outer layer\u003cbr\u003e • Outer sheath of special PVC compound type TM5 to DIN VDE 0207-363-4-1\/DIN EN 50363-4-1\u003cbr\u003e • Sheath colour grey (RAL 7001)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties\u003c\/strong\u003e:\u003cbr\u003e • The materials used in manufacture are cadmium-free and contain no silicone and free from substances harmful to the wetting properties of lacquers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests\u003c\/strong\u003e:\u003cbr\u003e • PVC self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)\u003cbr\u003e • Oil resistant to DIN EN 60811-404\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e:\u003cbr\u003e • G = with green-yellow conductor x = without green-yellow conductor (OZ)\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross-section is in mm².\u003cbr\u003e • Screened analogue type: H05VVC4V5-K (NYSLYCYÖ-JZ)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication\u003c\/strong\u003e:\u003cbr\u003e These cables are used for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms but not suitable for open air. These are designed as control and connecting cables to machines, tool machineries, conveyor belts and production lines.\u003cbr\u003e These cables are not effected to the chemical influences. Cables for moist and wet rooms, specially used for machines in breweries, bottling plants and car washing stations.\u003cbr\u003e These cables may be allowed to move once installed provided that the cables are not mechanically stressed during movement.\u003cbr\u003e = The product is conformed with the EC Low-Voltage Directive 2006\/95\/EC.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg-no.\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 G 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø min. - max. (mm)\u003c\/td\u003e\n\u003ctd\u003e6,9 - 8.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight - kg\/km\u003c\/td\u003e\n\u003ctd\u003e38,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. - kg\/km\u003c\/td\u003e\n\u003ctd\u003e104,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e13026\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134241718335,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/H05VV5-F_20NYSLY_C3_96-JZ_20Flexible_20Copper_20Cable-lg_615005a0-a749-459b-abb2-55acc4b7e98e.jpg?v=1571726644"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/H05VV5-F_NYSLYO-JZ_Flexible_Copper_Cable-lg.jpg?v=1524476235","url":"https:\/\/www.nassauelectrical.com\/collections\/helukabel-h05vv5-f-nyslyo-jz-flexible-number-coded-oil-resistant-bare-copper-conductor-meter-marking-cable.oembed?page=6","provider":"NassauElectrical","version":"1.0","type":"link"}