{"title":"Helukabel DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable","description":"","products":[{"product_id":"helukabel-19-awg-10-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52360","title":"Helukabel 19 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52360","description":"Helukabel 19 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52360\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52360. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 19 AWG 10 Cores DATAFLAMM Cable, 52360\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e10 x 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e137,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134318657599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg.jpg?v=1571726676"},{"product_id":"helukabel-19-awg-12-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52361","title":"Helukabel 19 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52361","description":"Helukabel 19 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52361\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52361. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 19 AWG 12 Cores DATAFLAMM Cable, 52361\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 x 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e10,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e86,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e167,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134324621375,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_b926c558-3b1f-4139-be76-0531cdbe2f26.jpg?v=1571726677"},{"product_id":"helukabel-19-awg-2-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52355","title":"Helukabel 19 AWG 2 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52355","description":"Helukabel 19 AWG 2 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52355\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 2 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52355. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 19 AWG 2 Cores DATAFLAMM Cable, 52355\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e5,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e14,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e40,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52355\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134347526207,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_489cc221-2d04-45a3-b6c3-ecdeea174022.jpg?v=1571726685"},{"product_id":"helukabel-19-awg-3-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52356","title":"Helukabel 19 AWG 3 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52356","description":"Helukabel 19 AWG 3 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52356\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 3 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52356. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 19 AWG 3 Cores DATAFLAMM Cable, 52356\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 x 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e5,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e21,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e51,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52356\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134386323519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_c7e630d5-401e-4698-a371-df396d214883.jpg?v=1571726692"},{"product_id":"helukabel-19-awg-4-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52357","title":"Helukabel 19 AWG 4 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52357","description":"Helukabel 19 AWG 4 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52357\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 4 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52357. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 19 AWG 4 Cores DATAFLAMM Cable, 52357\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 x 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e6,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e28,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e61,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52357\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134410342463,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_e3acec5d-6faf-478b-98d8-687821170125.jpg?v=1571726716"},{"product_id":"helukabel-19-awg-5-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52358","title":"Helukabel 19 AWG 5 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52358","description":"Helukabel 19 AWG 5 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52358\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 5 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52358. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 19 AWG 5 Cores DATAFLAMM Cable, 52358\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 x 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e6,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e36,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e76,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52358\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134426333247,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_c160d915-f7fa-4dbd-9f58-a99d196e7679.jpg?v=1571726721"},{"product_id":"helukabel-19-awg-7-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52359","title":"Helukabel 19 AWG 7 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52359","description":"Helukabel 19 AWG 7 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52359\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 19 AWG 7 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52359. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 19 AWG 7 Cores DATAFLAMM Cable, 52359\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 x 0,75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e7,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e50,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e97,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52359\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134447927359,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_3993121e-16af-4f00-8264-04d86e9a1787.jpg?v=1571726727"},{"product_id":"helukabel-20-awg-10-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52346","title":"Helukabel 20 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52346","description":"Helukabel 20 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52346\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52346. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 10 Cores DATAFLAMM Cable, 52346\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e10 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e8,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e48,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e101,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52346\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134486921279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_412bb65c-5a6a-4f3f-8ca9-1dfbe6fefe4b.jpg?v=1571726758"},{"product_id":"helukabel-20-awg-12-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52347","title":"Helukabel 20 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52347","description":"Helukabel 20 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52347\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52347. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 12 Cores DATAFLAMM Cable, 52347\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e8,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e57,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e117,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52347\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134494425151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_17f8cd20-0965-4575-be75-dc233160007a.jpg?v=1571726760"},{"product_id":"helukabel-20-awg-15-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52348","title":"Helukabel 20 AWG 15 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52348","description":"Helukabel 20 AWG 15 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52348\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 15 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52348. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 15 Cores DATAFLAMM Cable, 52348\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e15 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e72,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e145,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52348\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134506221631,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_593698fd-d529-45b7-94e8-4e88d661137b.jpg?v=1571726777"},{"product_id":"helukabel-20-awg-18-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52349","title":"Helukabel 20 AWG 18 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52349","description":"Helukabel 20 AWG 18 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52349\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 18 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52349. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 18 Cores DATAFLAMM Cable, 52349\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e10,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e86,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e171,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52349\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7134508417087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_1bdbdf1e-ea13-4d8b-a422-d00cd4b276a1.jpg?v=1571726779"},{"product_id":"helukabel-20-awg-2-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52341","title":"Helukabel 20 AWG 2 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52341","description":"Helukabel 20 AWG 2 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52341\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 2 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52341. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 2 Cores DATAFLAMM Cable, 52341\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e4,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e9,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e30,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52341\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7147931467839,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_f843e48f-225c-42ec-8202-87f3e9a16a04.jpg?v=1571726781"},{"product_id":"helukabel-20-awg-21-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52350","title":"Helukabel 20 AWG 21 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52350","description":"Helukabel 20 AWG 21 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52350\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 21 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52350. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 21 Cores DATAFLAMM Cable, 52350\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e21 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e11,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e101,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e197,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7147956994111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_5ec4d91c-4bb5-496a-8656-4b4aa5a9a6bb.jpg?v=1571726785"},{"product_id":"helukabel-20-awg-25-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52351","title":"Helukabel 20 AWG 25 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52351","description":"Helukabel 20 AWG 25 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52351\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 25 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52351. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 25 Cores DATAFLAMM Cable, 52351\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e12,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e120,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e230,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52351\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7147962597439,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_4aed7efb-3c0e-48d8-a43b-46a7e7565d72.jpg?v=1571726786"},{"product_id":"helukabel-20-awg-3-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52342","title":"Helukabel 20 AWG 3 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52342","description":"Helukabel 20 AWG 3 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52342\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 3 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52342. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 3 Cores DATAFLAMM Cable, 52342\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e4,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e14,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e36,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52342\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7147980980287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_ce765de9-e994-47d8-9099-a93f2ea9f79f.jpg?v=1571726810"},{"product_id":"helukabel-20-awg-30-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52352","title":"Helukabel 20 AWG 30 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52352","description":"Helukabel 20 AWG 30 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52352\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 30 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52352. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 30 Cores DATAFLAMM Cable, 52352\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e30 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e13,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e142,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e269,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52352\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148007292991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_c03739d2-ddb4-4622-8338-50e9ae20cdea.jpg?v=1571726814"},{"product_id":"helukabel-20-awg-34-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52353","title":"Helukabel 20 AWG 34 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52353","description":"Helukabel 20 AWG 34 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52353\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 34 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52353. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 34 Cores DATAFLAMM Cable, 52353\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e34 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e14,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e163,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e301,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52353\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148011126847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_1d03ef0d-42e3-40f3-9ce5-450d7fb20f7c.jpg?v=1571726815"},{"product_id":"helukabel-20-awg-4-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52343","title":"Helukabel 20 AWG 4 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52343","description":"Helukabel 20 AWG 4 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52343\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 4 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52343. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 4 Cores DATAFLAMM Cable, 52343\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e5,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e19,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e43,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52343\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148022595647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_e4e429c8-0959-4458-abaa-c885c96e253d.jpg?v=1571726817"},{"product_id":"helukabel-20-awg-40-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52354","title":"Helukabel 20 AWG 40 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52354","description":"Helukabel 20 AWG 40 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52354\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 40 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52354. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 40 Cores DATAFLAMM Cable, 52354\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e40 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e15,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e192,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e365,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52354\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148038127679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_9aa318f7-1cf1-421a-9d90-c0bf7331a5b7.jpg?v=1571726820"},{"product_id":"helukabel-20-awg-5-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52344","title":"Helukabel 20 AWG 5 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52344","description":"Helukabel 20 AWG 5 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52344\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 5 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52344. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 5 Cores DATAFLAMM Cable, 52344\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e5,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e24,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e56,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52344\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148046090303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_55cfea39-0c5b-4cc7-a7a6-2adfb97b7012.jpg?v=1571726836"},{"product_id":"helukabel-20-awg-7-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52345","title":"Helukabel 20 AWG 7 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52345","description":"Helukabel 20 AWG 7 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52345\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 20 AWG 7 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52345. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 20 AWG 7 Cores DATAFLAMM Cable, 52345\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 x 0,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e6,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e33,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e70,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148071682111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_79605101-5f0e-4983-9fec-dad5a1bffc39.jpg?v=1571726842"},{"product_id":"helukabel-22-awg-10-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52333","title":"Helukabel 22 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52333","description":"Helukabel 22 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52333\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52333. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 10 Cores DATAFLAMM Cable, 52333\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e10 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e7,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e32,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e80,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52333\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148085739583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_bb9d8968-9094-4bc9-8525-4b846e614b95.jpg?v=1571726848"},{"product_id":"helukabel-22-awg-12-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52334","title":"Helukabel 22 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52334","description":"Helukabel 22 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52334\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52334. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 12 Cores DATAFLAMM Cable, 52334\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e8,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e39,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e91,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52334\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148087312447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_30bdf199-03c0-4f65-adf2-e682289b7150.jpg?v=1571726849"},{"product_id":"helukabel-22-awg-15-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52335","title":"Helukabel 22 AWG 15 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52335","description":"Helukabel 22 AWG 15 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52335\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 15 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52335. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 15 Cores DATAFLAMM Cable, 52335\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e15 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e49,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e115,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148093177919,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_386531c7-23cc-487d-bfb1-d11a9bbcceff.jpg?v=1571726867"},{"product_id":"helukabel-22-awg-18-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52336","title":"Helukabel 22 AWG 18 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52336","description":"Helukabel 22 AWG 18 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52336\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 18 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52336. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 18 Cores DATAFLAMM Cable, 52336\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e59,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e135,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52336\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148097994815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_c427212f-270e-4cc4-9dd4-1ea38f05ee43.jpg?v=1571726868"},{"product_id":"helukabel-22-awg-2-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52328","title":"Helukabel 22 AWG 2 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52328","description":"Helukabel 22 AWG 2 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52328\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 2 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52328. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 2 Cores DATAFLAMM Cable, 52328\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e4,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e6,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e25,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52328\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148099436607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_0406e6ad-45b5-408b-91ea-c2bb398f3fe9.jpg?v=1571726869"},{"product_id":"helukabel-22-awg-21-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52337","title":"Helukabel 22 AWG 21 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52337","description":"Helukabel 22 AWG 21 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52337\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 21 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52337. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 21 Cores DATAFLAMM Cable, 52337\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e21 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e10,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e68,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e154,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52337\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148101107775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_832704ae-490c-48a5-b785-3ae73078feca.jpg?v=1571726870"},{"product_id":"helukabel-22-awg-25-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52338","title":"Helukabel 22 AWG 25 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52338","description":"Helukabel 22 AWG 25 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52338\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 25 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52338. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 25 Cores DATAFLAMM Cable, 52338\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e12,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e81,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e180,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52338\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148106842175,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_6dd3ecce-f0e9-4d74-988a-de5bd28c0943.jpg?v=1571726871"},{"product_id":"helukabel-22-awg-3-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52329","title":"Helukabel 22 AWG 3 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52329","description":"Helukabel 22 AWG 3 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52329\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 3 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52329. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 3 Cores DATAFLAMM Cable, 52329\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e4,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e9,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e30,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52329\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148108775487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_f4e43178-751d-43a5-8467-e2ccec30f77b.jpg?v=1571726872"},{"product_id":"helukabel-22-awg-34-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52339","title":"Helukabel 22 AWG 34 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52339","description":"Helukabel 22 AWG 34 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52339\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 34 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52339. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 34 Cores DATAFLAMM Cable, 52339\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e34 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e13,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e111,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e233,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52339\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148114935871,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_ef01f98a-6582-4f26-addb-5aaa6671e6e3.jpg?v=1571726874"},{"product_id":"helukabel-22-awg-4-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52330","title":"Helukabel 22 AWG 4 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52330","description":"Helukabel 22 AWG 4 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52330\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 4 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52330. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 4 Cores DATAFLAMM Cable, 52330\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e5,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e13,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e35,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52330\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148115329087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_41904303-3b19-45e5-9037-80f18ee4228c.jpg?v=1571726874"},{"product_id":"helukabel-22-awg-40-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52340","title":"Helukabel 22 AWG 40 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52340","description":"Helukabel 22 AWG 40 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52340\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 40 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52340. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 40 Cores DATAFLAMM Cable, 52340\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e40 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e14,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e130,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e272,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148120244287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_b0d25629-618f-44b1-abea-fb1edf7c7e38.jpg?v=1571726875"},{"product_id":"helukabel-22-awg-5-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52331","title":"Helukabel 22 AWG 5 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52331","description":"Helukabel 22 AWG 5 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52331\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 5 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52331. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 5 Cores DATAFLAMM Cable, 52331\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e5,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e16,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e43,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148120997951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_18e8ae88-610d-4837-82a6-6008e81b4c92.jpg?v=1571726876"},{"product_id":"helukabel-22-awg-7-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52332","title":"Helukabel 22 AWG 7 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52332","description":"Helukabel 22 AWG 7 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52332\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 22 AWG 7 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52332. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 22 AWG 7 Cores DATAFLAMM Cable, 52332\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 x 0,34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e6,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e22,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e58,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52332\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148127322175,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_8e181e35-1c2f-4f9d-84ee-92d9dd7f95f6.jpg?v=1571726877"},{"product_id":"helukabel-24-awg-10-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52322","title":"Helukabel 24 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52322","description":"Helukabel 24 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52322\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52322. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 10 Cores DATAFLAMM Cable, 52322\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e10 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e6,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e24,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e56,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52322\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148131057727,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_8414bb8d-c3dc-4773-8826-acfe77c839f3.jpg?v=1571726879"},{"product_id":"helukabel-24-awg-12-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52323","title":"Helukabel 24 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52323","description":"Helukabel 24 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52323\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52323. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 12 Cores DATAFLAMM Cable, 52323\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e6,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e28,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e64,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52323\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148135710783,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_38b91426-be19-4765-adc9-70b52202d38b.jpg?v=1571726880"},{"product_id":"helukabel-24-awg-15-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52324","title":"Helukabel 24 AWG 15 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52324","description":"Helukabel 24 AWG 15 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52324\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 15 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52324. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 15 Cores DATAFLAMM Cable, 52324\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e15 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e7,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e36,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e80,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148139544639,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_85493953-4d49-432c-82e8-826c1c0850d8.jpg?v=1571726928"},{"product_id":"helukabel-24-awg-18-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52430","title":"Helukabel 24 AWG 18 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52430","description":"Helukabel 24 AWG 18 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52430\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 18 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52430. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 18 Cores DATAFLAMM Cable, 52430\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e18 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e7,9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e43,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e90,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148146524223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_d05a021b-6c68-4a91-8598-fffa40e8ab0f.jpg?v=1571726928"},{"product_id":"helukabel-24-awg-2-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52317","title":"Helukabel 24 AWG 2 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52317","description":"Helukabel 24 AWG 2 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52317\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 2 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52317. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 2 Cores DATAFLAMM Cable, 52317\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e2 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e3,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e4,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e18,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52317\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148150652991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_5d7cc637-70bb-4a96-8197-db9193063827.jpg?v=1571726929"},{"product_id":"helukabel-24-awg-21-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52431","title":"Helukabel 24 AWG 21 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52431","description":"Helukabel 24 AWG 21 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52431\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 21 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52431. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 21 Cores DATAFLAMM Cable, 52431\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e21 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e8,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e50,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e105,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52431\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148159991871,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_0d2decef-90c8-4a4e-b1f3-bb15b25bdf20.jpg?v=1571726930"},{"product_id":"helukabel-24-awg-25-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52325","title":"Helukabel 24 AWG 25 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52325","description":"Helukabel 24 AWG 25 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52325\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 25 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52325. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 25 Cores DATAFLAMM Cable, 52325\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e25 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e9,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e59,8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e121,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148164186175,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_1eafaf34-2efe-4ae1-9924-7c5aa29ce49f.jpg?v=1571726931"},{"product_id":"helukabel-24-awg-3-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52318","title":"Helukabel 24 AWG 3 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52318","description":"Helukabel 24 AWG 3 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52318\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 3 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52318. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 3 Cores DATAFLAMM Cable, 52318\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e3 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e4,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e7,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e21,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52318\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148172542015,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_7c936e39-0278-41be-897b-35f5829d295d.jpg?v=1571726932"},{"product_id":"helukabel-24-awg-34-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52326","title":"Helukabel 24 AWG 34 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52326","description":"Helukabel 24 AWG 34 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52326\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 34 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52326. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 34 Cores DATAFLAMM Cable, 52326\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e34 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e11,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e81,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e168,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148181323839,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_2f2107fa-42ff-45aa-b247-7fda10758212.jpg?v=1571726934"},{"product_id":"helukabel-24-awg-4-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52319","title":"Helukabel 24 AWG 4 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52319","description":"Helukabel 24 AWG 4 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52319.\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 4 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52319. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 4 Cores DATAFLAMM Cable, 52319\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e4 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e4,3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e9,5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e26,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148185255999,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_354b04bf-8c02-4b89-baca-32d19829d0f7.jpg?v=1571726934"},{"product_id":"helukabel-24-awg-40-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52327","title":"Helukabel 24 AWG 40 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52327","description":"Helukabel 24 AWG 40 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52327\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 40 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52327. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 40 Cores DATAFLAMM Cable, 52327\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e40 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e12,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e96,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e196,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52327\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148193251391,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_27218e1d-d390-400b-96d7-6e7a2d3a0f82.jpg?v=1571726935"},{"product_id":"helukabel-24-awg-5-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52320","title":"Helukabel 24 AWG 5 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52320","description":"Helukabel 24 AWG 5 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52320\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 5 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52320. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 5 Cores DATAFLAMM Cable, 52320\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e5 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e4,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e12,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e31,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148195872831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_81ba5113-3c06-462b-96c7-5bbc3cb010de.jpg?v=1571726935"},{"product_id":"helukabel-24-awg-7-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52321","title":"Helukabel 24 AWG 7 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52321","description":"Helukabel 24 AWG 7 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52321\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 24 AWG 7 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52321. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 24 AWG 7 Cores DATAFLAMM Cable, 52321\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e7 x 0,25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e5,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e16,6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e40,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148212355135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_1901f370-3693-4945-a90b-cb2afefff893.jpg?v=1571726937"},{"product_id":"helukabel-26-awg-10-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52307","title":"Helukabel 26 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52307","description":"Helukabel 26 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52307\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 26 AWG 10 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52307. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 26 AWG 10 Cores DATAFLAMM Cable, 52307\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e10 x 0,14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e5,4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e13,2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e38,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52307\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148228214847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_da8a4cb4-983a-453b-b640-b607cc035744.jpg?v=1571726939"},{"product_id":"helukabel-26-awg-12-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52308","title":"Helukabel 26 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52308","description":"Helukabel 26 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52308\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 26 AWG 12 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52308. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 26 AWG 12 Cores DATAFLAMM Cable, 52308\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e12 x 0,14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e5,7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e16,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e45,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148232835135,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_c6eb41c9-44bc-4a9e-8361-9a2375f4b5db.jpg?v=1571726940"},{"product_id":"helukabel-26-awg-15-cores-dataflamm-halogen-free-special-data-cable-meter-marking-cable-52309","title":"Helukabel 26 AWG 15 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52309","description":"Helukabel 26 AWG 15 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52309\u003cmeta name=\"Description\" content=\"Browse our selection of Helukabel 26 AWG 15 Cores DATAFLAMM Halogen Free Special Data Cable Meter Marking Cable 52309. Click for a free quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Helukabel, DATAFLAMM Cable, DATAFLAMM Halogen Free Cable, Special Data Cable, Meter Marking Cable, Helukabel Price, DATAFLAMM Cable Price, DATAFLAMM Halogen Free Cable Price, Special Data Cable Price, Meter Marking Cable Price, Helukabel Quote, DATAFLAMM Cable Quote, DATAFLAMM Halogen Free Cable Quote, Special Data Cable Quote, Meter Marking Cable Quote, 26 AWG 15 Cores DATAFLAMM Cable, 52309\"\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Data:\u003c\/strong\u003e\u003cbr\u003e Halogen-free special data cable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Range:\u003c\/strong\u003e\u003cbr\u003e • Flexing +5°C to +70°C\u003cbr\u003e • Fixed installation -40°C to +70°C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Peak Voltage:\u003c\/strong\u003e\u003cbr\u003e • (Not for heavy current installation purposes)\u003cbr\u003e • 0,14 mm² = 350 V\u003cbr\u003e • ≥ 0,25 mm² = 500 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Voltage:\u003c\/strong\u003e\u003cbr\u003e • 0,14 mm² = 800 V\u003cbr\u003e • ≥ 0,25 mm² = 1200 V\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e Min. 2 GOhm x km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCapacitance:\u003c\/strong\u003e Core\/core \u0026lt; 70 nF\/km\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum Bending Radius:\u003c\/strong\u003e\u003cbr\u003e • Flexing 7,5x cable Ø\u003cbr\u003e • Fixed installation 4x cable Ø\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRadiation Resistance:\u003c\/strong\u003e Up to 100x106 cJ\/kg (up to 100 Mrad)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Structure:\u003c\/strong\u003e\u003cbr\u003e • Bare copper conductor, fine wire to DIN VDE 0812\u003cbr\u003e • Conductor construction: 0,34 mm² = 7x0,25 mm\u003cbr\u003e • Core insulation of PE compound type LD\/MD to DIN VDE 0819-103 \/ DIN EN 50290-2-23\u003cbr\u003e • Core identification to DIN 47100, without colour repetition\u003cbr\u003e • Cores stranded in layers with optimal lay length\u003cbr\u003e • Outer sheath compound type HM2 to DIN VDE 0207 part 24\u003cbr\u003e • Sheath colour: grey (RAL 7005)\u003cbr\u003e • With meter marking\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProperties:\u003c\/strong\u003e\u003cbr\u003e • PE-insulated cores, compared with PVC-insulated cores, assure a remarkable and more favourable capacitance values\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTests:\u003c\/strong\u003e\u003cbr\u003e • Halogen-free acc. to DIN VDE 0482-754-1, DIN EN 60754-1, IEC 60754-1 (previously DIN VDE 0482-267-2-1)\u003cbr\u003e • Corrosiveness of combustion gases acc. to DIN VDE 0482-754-2, DIN EN 60754-2, IEC 60754-2 (previously DIN VDE 0482-267-2-2)\u003cbr\u003e • Halogen-free sheath compound, self-extinguishing and flame retardant acc. to DIN VDE 0482-332-1-2, DIN EN 60332-1-2, IEC 60332-1-2 (equivalent DIN VDE 0472 part 804 test method B)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote:\u003c\/strong\u003e\u003cbr\u003e • AWG sizes are approximate equivalent values. The actual cross section is in mm².\u003cbr\u003e • Screened analogue type: DATAFLAMM®-C\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplication:\u003c\/strong\u003e\u003cbr\u003e DATAFLAMM® halogen-free data cables are used as connecting cable for signal, measuring, control, call-announcing and two-way intercom speaking systems, clock installations, electronic weighing equipment and electrical apparatus for office requirements. The cables are suitable for installation in dry, damp and wet environments. These cables are generally installed in telecommunication apparatus and data transmission systems in public buildings, laboratories, trading centres where the freedom from halogen in case of fire and the flame propagation must be avoided. The halogen-free thermoplastic sheath produce neither corrosive nor toxic gases.\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eawg\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno.cores x cross-sec. mm²\u003c\/td\u003e\n\u003ctd\u003e15 x 0,14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eouter ø app. mm\u003c\/td\u003e\n\u003ctd\u003e6,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecop. weight kg \/ km\u003c\/td\u003e\n\u003ctd\u003e20,1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight app. kg \/ km\u003c\/td\u003e\n\u003ctd\u003e57,0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ehelukabel part number\u003c\/td\u003e\n\u003ctd\u003e52309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Helukabel","offers":[{"title":"Default Title","offer_id":7148241322047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/DATAFLAMM_20Halogen_20Free_20Cable-lg_91ab7e01-5889-4bf4-8d5a-5c90280e22ea.jpg?v=1571726941"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/helukabel-dataflamm-halogen-free-special-data-cable-meter-marking-cable.oembed?page=4","provider":"NassauElectrical","version":"1.0","type":"link"}