{"title":"General Cable Uniblend® CPE High Speed Type MV-105 3C 220 Mils EPR Copper Tape Shield with Overall CPE Jacket Medium Voltage Power Shielded UL","description":"","products":[{"product_id":"uniblend-cpe-high-speed-1-0-awg-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacket-medium-voltage-power-shielded-ul","title":"General Cable Uniblend® CPE High Speed 1\/0 AWG Type MV-105 3C 220 Mils EPR Copper Tape Shield with Overall CPE Jacket Medium Voltage Power Shielded UL","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS):\u003c\/strong\u003e Extruded thermoset semi-conducting stresscontrol layer over conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Insulation Shield (EIS)\u003c\/strong\u003e: Thermoset semi-conducting polymeric layer free stripping from insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e 5 mil annealed copper tape with an overlap of 25%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e 1 bare grounding conductor may be in contact with metallic shielding tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Lead-free, moisture- and sunlight-resistant Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical\u003cbr\u003e • In wet or dry locations when installed in accordance with NEC\u003cbr\u003e • In aerial, direct burial, conduit, open tray and underground duct installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 105?C\u003cbr\u003e • Excellent heat and moisture resistance\u003cbr\u003e • Outstanding corona resistance\u003cbr\u003e • Flexibility for easy handling\u003cbr\u003e • Low friction for easy pulling\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Electrical stability under stress\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Meets cold bend test at -35?C\u003cbr\u003e • 105°C rating for continuous operation\u003cbr\u003e • 140°C rating for emergency overload conditions\u003cbr\u003e • 250°C rating for short circuit conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e • National Electrical Code (NEC)\u003cbr\u003e • UL 1072\u003cbr\u003e • ICEA S-93-639\/NEMA WC74\u003cbr\u003e • ICEA S-97-682\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501\u003cbr\u003e • UL 1685 (70,000 BTU\/hr)\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Flame Tests:\u003c\/strong\u003e IEEE 1202 (70,000 BTU\/hr)\/CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cbr\u003e • Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit\u003cbr\u003e • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/ kcmil)\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(min.)\u003c\/td\u003e\n\u003ctd\u003e0.780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(max.)\u003c\/td\u003e\n\u003ctd\u003e0.865\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eground wire (awg)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(diameter in inches)\u003c\/td\u003e\n\u003ctd\u003e2.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable((diameter in mm)\u003c\/td\u003e\n\u003ctd\u003e55.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in lbs\/1000 ft )\u003c\/td\u003e\n\u003ctd\u003e2811\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4183\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000ft)\u003c\/td\u003e\n\u003ctd\u003e1343\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1998\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e215\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e215\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e15593.445105*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163761033279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_a40cdbdc-ce96-4f0e-aaa6-a4467faf83e1.jpg?v=1571728319"},{"product_id":"uniblend-cpe-high-speed-1000mcm-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacket-medium-voltage-power-shielded-ul","title":"General Cable Uniblend® CPE High Speed 1000MCM Type MV-105 3C 220 Mils EPR Copper Tape Shield with Overall CPE Jacket Medium Voltage Power Shielded UL","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS):\u003c\/strong\u003e Extruded thermoset semi-conducting stresscontrol layer over conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Insulation Shield (EIS)\u003c\/strong\u003e: Thermoset semi-conducting polymeric layer free stripping from insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e 5 mil annealed copper tape with an overlap of 25%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e 1 bare grounding conductor may be in contact with metallic shielding tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Lead-free, moisture- and sunlight-resistant Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical\u003cbr\u003e • In wet or dry locations when installed in accordance with NEC\u003cbr\u003e • In aerial, direct burial, conduit, open tray and underground duct installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 105?C\u003cbr\u003e • Excellent heat and moisture resistance\u003cbr\u003e • Outstanding corona resistance\u003cbr\u003e • Flexibility for easy handling\u003cbr\u003e • Low friction for easy pulling\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Electrical stability under stress\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Meets cold bend test at -35?C\u003cbr\u003e • 105°C rating for continuous operation\u003cbr\u003e • 140°C rating for emergency overload conditions\u003cbr\u003e • 250°C rating for short circuit conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e • National Electrical Code (NEC)\u003cbr\u003e • UL 1072\u003cbr\u003e • ICEA S-93-639\/NEMA WC74\u003cbr\u003e • ICEA S-97-682\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501\u003cbr\u003e • UL 1685 (70,000 BTU\/hr)\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Flame Tests:\u003c\/strong\u003e IEEE 1202 (70,000 BTU\/hr)\/CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cbr\u003e • Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit\u003cbr\u003e • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/ kcmil)\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(min.)\u003c\/td\u003e\n\u003ctd\u003e1.520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(max.)\u003c\/td\u003e\n\u003ctd\u003e1.610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eground wire (awg)\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e3.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(diameter in inches)\u003c\/td\u003e\n\u003ctd\u003e3.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable((diameter in mm)\u003c\/td\u003e\n\u003ctd\u003e101.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in lbs\/1000 ft )\u003c\/td\u003e\n\u003ctd\u003e13983\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in kg\/km)\u003c\/td\u003e\n\u003ctd\u003e20810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000ft)\u003c\/td\u003e\n\u003ctd\u003e10124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e15064\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e725\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e615\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e770\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e860\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e15593.447505*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163763327039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_d4f38837-14d8-45d4-944a-c14da161fab2.jpg?v=1571728320"},{"product_id":"uniblend-cpe-high-speed-2-awg-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacket-medium-voltage-power-shielded-ul","title":"General Cable Uniblend® CPE High Speed 2 AWG Type MV-105 3C 220 Mils EPR Copper Tape Shield with Overall CPE Jacket Medium Voltage Power Shielded UL","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS):\u003c\/strong\u003e Extruded thermoset semi-conducting stresscontrol layer over conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Insulation Shield (EIS)\u003c\/strong\u003e: Thermoset semi-conducting polymeric layer free stripping from insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e 5 mil annealed copper tape with an overlap of 25%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e 1 bare grounding conductor may be in contact with metallic shielding tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Lead-free, moisture- and sunlight-resistant Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical\u003cbr\u003e • In wet or dry locations when installed in accordance with NEC\u003cbr\u003e • In aerial, direct burial, conduit, open tray and underground duct installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 105?C\u003cbr\u003e • Excellent heat and moisture resistance\u003cbr\u003e • Outstanding corona resistance\u003cbr\u003e • Flexibility for easy handling\u003cbr\u003e • Low friction for easy pulling\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Electrical stability under stress\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Meets cold bend test at -35?C\u003cbr\u003e • 105°C rating for continuous operation\u003cbr\u003e • 140°C rating for emergency overload conditions\u003cbr\u003e • 250°C rating for short circuit conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e • National Electrical Code (NEC)\u003cbr\u003e • UL 1072\u003cbr\u003e • ICEA S-93-639\/NEMA WC74\u003cbr\u003e • ICEA S-97-682\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501\u003cbr\u003e • UL 1685 (70,000 BTU\/hr)\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Flame Tests:\u003c\/strong\u003e IEEE 1202 (70,000 BTU\/hr)\/CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cbr\u003e • Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit\u003cbr\u003e • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/ kcmil)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(min.)\u003c\/td\u003e\n\u003ctd\u003e0.710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(max.)\u003c\/td\u003e\n\u003ctd\u003e0.800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eground wire (awg)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(diameter in inches)\u003c\/td\u003e\n\u003ctd\u003e2.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable((diameter in mm)\u003c\/td\u003e\n\u003ctd\u003e51.82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in lbs\/1000 ft )\u003c\/td\u003e\n\u003ctd\u003e2226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000ft)\u003c\/td\u003e\n\u003ctd\u003e913\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1358\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e165\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e15593.440205*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163763523647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_100c25df-125a-493c-b28d-ed598cbe450e.jpg?v=1571728320"},{"product_id":"uniblend-cpe-high-speed-2-0-awg-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacket-medium-voltage-power-shielded-ul","title":"General Cable Uniblend® CPE High Speed 2\/0 AWG Type MV-105 3C 220 Mils EPR Copper Tape Shield with Overall CPE Jacket Medium Voltage Power Shielded UL","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS):\u003c\/strong\u003e Extruded thermoset semi-conducting stresscontrol layer over conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Insulation Shield (EIS)\u003c\/strong\u003e: Thermoset semi-conducting polymeric layer free stripping from insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e 5 mil annealed copper tape with an overlap of 25%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e 1 bare grounding conductor may be in contact with metallic shielding tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Lead-free, moisture- and sunlight-resistant Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical\u003cbr\u003e • In wet or dry locations when installed in accordance with NEC\u003cbr\u003e • In aerial, direct burial, conduit, open tray and underground duct installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 105?C\u003cbr\u003e • Excellent heat and moisture resistance\u003cbr\u003e • Outstanding corona resistance\u003cbr\u003e • Flexibility for easy handling\u003cbr\u003e • Low friction for easy pulling\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Electrical stability under stress\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Meets cold bend test at -35?C\u003cbr\u003e • 105°C rating for continuous operation\u003cbr\u003e • 140°C rating for emergency overload conditions\u003cbr\u003e • 250°C rating for short circuit conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e • National Electrical Code (NEC)\u003cbr\u003e • UL 1072\u003cbr\u003e • ICEA S-93-639\/NEMA WC74\u003cbr\u003e • ICEA S-97-682\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501\u003cbr\u003e • UL 1685 (70,000 BTU\/hr)\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Flame Tests:\u003c\/strong\u003e IEEE 1202 (70,000 BTU\/hr)\/CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cbr\u003e • Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit\u003cbr\u003e • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/ kcmil)\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.38\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(min.)\u003c\/td\u003e\n\u003ctd\u003e0.820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(max.)\u003c\/td\u003e\n\u003ctd\u003e0.905\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eground wire (awg)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(diameter in inches)\u003c\/td\u003e\n\u003ctd\u003e2.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable((diameter in mm)\u003c\/td\u003e\n\u003ctd\u003e58.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in lbs\/1000 ft )\u003c\/td\u003e\n\u003ctd\u003e3163\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4707\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000ft)\u003c\/td\u003e\n\u003ctd\u003e1609\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e15593.445205*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163763785791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_41b2e943-a30f-493b-9782-9e7edfe45fe8.jpg?v=1571728320"},{"product_id":"uniblend-cpe-high-speed-250mcm-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacket-medium-voltage-power-shielded-ul","title":"General Cable Uniblend® CPE High Speed 250MCM Type MV-105 3C 220 Mils EPR Copper Tape Shield with Overall CPE Jacket Medium Voltage Power Shielded UL","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS):\u003c\/strong\u003e Extruded thermoset semi-conducting stresscontrol layer over conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Insulation Shield (EIS)\u003c\/strong\u003e: Thermoset semi-conducting polymeric layer free stripping from insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e 5 mil annealed copper tape with an overlap of 25%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e 1 bare grounding conductor may be in contact with metallic shielding tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Lead-free, moisture- and sunlight-resistant Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical\u003cbr\u003e • In wet or dry locations when installed in accordance with NEC\u003cbr\u003e • In aerial, direct burial, conduit, open tray and underground duct installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 105?C\u003cbr\u003e • Excellent heat and moisture resistance\u003cbr\u003e • Outstanding corona resistance\u003cbr\u003e • Flexibility for easy handling\u003cbr\u003e • Low friction for easy pulling\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Electrical stability under stress\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Meets cold bend test at -35?C\u003cbr\u003e • 105°C rating for continuous operation\u003cbr\u003e • 140°C rating for emergency overload conditions\u003cbr\u003e • 250°C rating for short circuit conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e • National Electrical Code (NEC)\u003cbr\u003e • UL 1072\u003cbr\u003e • ICEA S-93-639\/NEMA WC74\u003cbr\u003e • ICEA S-97-682\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501\u003cbr\u003e • UL 1685 (70,000 BTU\/hr)\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Flame Tests:\u003c\/strong\u003e IEEE 1202 (70,000 BTU\/hr)\/CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cbr\u003e • Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit\u003cbr\u003e • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/ kcmil)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(min.)\u003c\/td\u003e\n\u003ctd\u003e0.970\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(max.)\u003c\/td\u003e\n\u003ctd\u003e1.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eground wire (awg)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(diameter in inches)\u003c\/td\u003e\n\u003ctd\u003e2.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable((diameter in mm)\u003c\/td\u003e\n\u003ctd\u003e67.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in lbs\/1000 ft )\u003c\/td\u003e\n\u003ctd\u003e4775\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in kg\/km)\u003c\/td\u003e\n\u003ctd\u003e7106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000ft)\u003c\/td\u003e\n\u003ctd\u003e2812\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4184\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e15593.446005*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163763982399,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_dc7648bf-798a-41e2-8bfc-c7732b80c1c2.jpg?v=1571728320"},{"product_id":"uniblend-cpe-high-speed-350mcm-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacket-medium-voltage-power-shielded-ul","title":"General Cable Uniblend® CPE High Speed 350MCM Type MV-105 3C 220 Mils EPR Copper Tape Shield with Overall CPE Jacket Medium Voltage Power Shielded UL","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS):\u003c\/strong\u003e Extruded thermoset semi-conducting stresscontrol layer over conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Insulation Shield (EIS)\u003c\/strong\u003e: Thermoset semi-conducting polymeric layer free stripping from insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e 5 mil annealed copper tape with an overlap of 25%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e 1 bare grounding conductor may be in contact with metallic shielding tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Lead-free, moisture- and sunlight-resistant Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical\u003cbr\u003e • In wet or dry locations when installed in accordance with NEC\u003cbr\u003e • In aerial, direct burial, conduit, open tray and underground duct installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 105?C\u003cbr\u003e • Excellent heat and moisture resistance\u003cbr\u003e • Outstanding corona resistance\u003cbr\u003e • Flexibility for easy handling\u003cbr\u003e • Low friction for easy pulling\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Electrical stability under stress\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Meets cold bend test at -35?C\u003cbr\u003e • 105°C rating for continuous operation\u003cbr\u003e • 140°C rating for emergency overload conditions\u003cbr\u003e • 250°C rating for short circuit conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e • National Electrical Code (NEC)\u003cbr\u003e • UL 1072\u003cbr\u003e • ICEA S-93-639\/NEMA WC74\u003cbr\u003e • ICEA S-97-682\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501\u003cbr\u003e • UL 1685 (70,000 BTU\/hr)\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Flame Tests:\u003c\/strong\u003e IEEE 1202 (70,000 BTU\/hr)\/CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cbr\u003e • Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit\u003cbr\u003e • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/ kcmil)\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(min.)\u003c\/td\u003e\n\u003ctd\u003e1.070\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(max.)\u003c\/td\u003e\n\u003ctd\u003e1.155\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eground wire (awg)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(diameter in inches)\u003c\/td\u003e\n\u003ctd\u003e2.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable((diameter in mm)\u003c\/td\u003e\n\u003ctd\u003e74.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in lbs\/1000 ft )\u003c\/td\u003e\n\u003ctd\u003e6182\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in kg\/km)\u003c\/td\u003e\n\u003ctd\u003e9200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000ft)\u003c\/td\u003e\n\u003ctd\u003e3766\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e5604\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e435\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e15593.446205*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163764375615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_23ab6041-6aa4-4d72-8f5c-fbe474db8fed.jpg?v=1571728320"},{"product_id":"uniblend-cpe-high-speed-4-0-awg-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacket-medium-voltage-power-shielded-ul","title":"General Cable Uniblend® CPE High Speed 4\/0 AWG Type MV-105 3C 220 Mils EPR Copper Tape Shield with Overall CPE Jacket Medium Voltage Power Shielded UL","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS):\u003c\/strong\u003e Extruded thermoset semi-conducting stresscontrol layer over conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Insulation Shield (EIS)\u003c\/strong\u003e: Thermoset semi-conducting polymeric layer free stripping from insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e 5 mil annealed copper tape with an overlap of 25%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e 1 bare grounding conductor may be in contact with metallic shielding tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Lead-free, moisture- and sunlight-resistant Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical\u003cbr\u003e • In wet or dry locations when installed in accordance with NEC\u003cbr\u003e • In aerial, direct burial, conduit, open tray and underground duct installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 105?C\u003cbr\u003e • Excellent heat and moisture resistance\u003cbr\u003e • Outstanding corona resistance\u003cbr\u003e • Flexibility for easy handling\u003cbr\u003e • Low friction for easy pulling\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Electrical stability under stress\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Meets cold bend test at -35?C\u003cbr\u003e • 105°C rating for continuous operation\u003cbr\u003e • 140°C rating for emergency overload conditions\u003cbr\u003e • 250°C rating for short circuit conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e • National Electrical Code (NEC)\u003cbr\u003e • UL 1072\u003cbr\u003e • ICEA S-93-639\/NEMA WC74\u003cbr\u003e • ICEA S-97-682\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501\u003cbr\u003e • UL 1685 (70,000 BTU\/hr)\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Flame Tests:\u003c\/strong\u003e IEEE 1202 (70,000 BTU\/hr)\/CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cbr\u003e • Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit\u003cbr\u003e • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/ kcmil)\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(min.)\u003c\/td\u003e\n\u003ctd\u003e0.920\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(max.)\u003c\/td\u003e\n\u003ctd\u003e1.005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eground wire (awg)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(diameter in inches)\u003c\/td\u003e\n\u003ctd\u003e2.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable((diameter in mm)\u003c\/td\u003e\n\u003ctd\u003e64.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in lbs\/1000 ft )\u003c\/td\u003e\n\u003ctd\u003e4203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in kg\/km)\u003c\/td\u003e\n\u003ctd\u003e6255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000ft)\u003c\/td\u003e\n\u003ctd\u003e2398\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3567\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e285\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e15593.445405*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163764539455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_3dbb3bc0-d12e-4675-ba21-e93ad9530cd3.jpg?v=1571728320"},{"product_id":"uniblend-cpe-high-speed-500mcm-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacket-medium-voltage-power-shielded-ul","title":"General Cable Uniblend® CPE High Speed 500MCM Type MV-105 3C 220 Mils EPR Copper Tape Shield with Overall CPE Jacket Medium Voltage Power Shielded UL","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS):\u003c\/strong\u003e Extruded thermoset semi-conducting stresscontrol layer over conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Insulation Shield (EIS)\u003c\/strong\u003e: Thermoset semi-conducting polymeric layer free stripping from insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e 5 mil annealed copper tape with an overlap of 25%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e 1 bare grounding conductor may be in contact with metallic shielding tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Lead-free, moisture- and sunlight-resistant Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical\u003cbr\u003e • In wet or dry locations when installed in accordance with NEC\u003cbr\u003e • In aerial, direct burial, conduit, open tray and underground duct installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 105?C\u003cbr\u003e • Excellent heat and moisture resistance\u003cbr\u003e • Outstanding corona resistance\u003cbr\u003e • Flexibility for easy handling\u003cbr\u003e • Low friction for easy pulling\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Electrical stability under stress\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Meets cold bend test at -35?C\u003cbr\u003e • 105°C rating for continuous operation\u003cbr\u003e • 140°C rating for emergency overload conditions\u003cbr\u003e • 250°C rating for short circuit conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e • National Electrical Code (NEC)\u003cbr\u003e • UL 1072\u003cbr\u003e • ICEA S-93-639\/NEMA WC74\u003cbr\u003e • ICEA S-97-682\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501\u003cbr\u003e • UL 1685 (70,000 BTU\/hr)\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Flame Tests:\u003c\/strong\u003e IEEE 1202 (70,000 BTU\/hr)\/CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cbr\u003e • Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit\u003cbr\u003e • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/ kcmil)\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(min.)\u003c\/td\u003e\n\u003ctd\u003e1.190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(max.)\u003c\/td\u003e\n\u003ctd\u003e1.275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eground wire (awg)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e3.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(diameter in inches)\u003c\/td\u003e\n\u003ctd\u003e3.21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable((diameter in mm)\u003c\/td\u003e\n\u003ctd\u003e81.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in lbs\/1000 ft )\u003c\/td\u003e\n\u003ctd\u003e7686\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in kg\/km)\u003c\/td\u003e\n\u003ctd\u003e11438\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000ft)\u003c\/td\u003e\n\u003ctd\u003e5244\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e7803\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e525\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e535\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e15593.446505*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163764998207,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_0aadde9c-3aec-497c-92e9-2a6cd5f9c947.jpg?v=1571728320"},{"product_id":"uniblend-cpe-high-speed-750mcm-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacket-medium-voltage-power-shielded-ul","title":"General Cable Uniblend® CPE High Speed 750MCM Type MV-105 3C 220 Mils EPR Copper Tape Shield with Overall CPE Jacket Medium Voltage Power Shielded UL","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS):\u003c\/strong\u003e Extruded thermoset semi-conducting stresscontrol layer over conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Insulation Shield (EIS)\u003c\/strong\u003e: Thermoset semi-conducting polymeric layer free stripping from insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e 5 mil annealed copper tape with an overlap of 25%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e 1 bare grounding conductor may be in contact with metallic shielding tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Lead-free, moisture- and sunlight-resistant Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical\u003cbr\u003e • In wet or dry locations when installed in accordance with NEC\u003cbr\u003e • In aerial, direct burial, conduit, open tray and underground duct installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 105?C\u003cbr\u003e • Excellent heat and moisture resistance\u003cbr\u003e • Outstanding corona resistance\u003cbr\u003e • Flexibility for easy handling\u003cbr\u003e • Low friction for easy pulling\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Electrical stability under stress\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Meets cold bend test at -35?C\u003cbr\u003e • 105°C rating for continuous operation\u003cbr\u003e • 140°C rating for emergency overload conditions\u003cbr\u003e • 250°C rating for short circuit conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e • National Electrical Code (NEC)\u003cbr\u003e • UL 1072\u003cbr\u003e • ICEA S-93-639\/NEMA WC74\u003cbr\u003e • ICEA S-97-682\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501\u003cbr\u003e • UL 1685 (70,000 BTU\/hr)\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Flame Tests:\u003c\/strong\u003e IEEE 1202 (70,000 BTU\/hr)\/CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cbr\u003e • Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit\u003cbr\u003e • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size (awg\/ kcmil)\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal conductor diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(min.)\u003c\/td\u003e\n\u003ctd\u003e1.370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003einsulation diameter inches(max.)\u003c\/td\u003e\n\u003ctd\u003e1.460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eground wire (awg)\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e3.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(diameter in inches)\u003c\/td\u003e\n\u003ctd\u003e3.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable((diameter in mm)\u003c\/td\u003e\n\u003ctd\u003e91.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in lbs\/1000 ft )\u003c\/td\u003e\n\u003ctd\u003e10978\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable(weight in kg\/km)\u003c\/td\u003e\n\u003ctd\u003e16337\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000ft)\u003c\/td\u003e\n\u003ctd\u003e7682\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e11431\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(conduit in air (1) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e635\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e545\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(underground duct (2) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e585\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 90?c)\u003c\/td\u003e\n\u003ctd\u003e670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacity(tray (3) in 105?c)\u003c\/td\u003e\n\u003ctd\u003e745\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e15593.447005*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163765358655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_e6a937ce-5de0-41a2-b4f7-6ad896044157.jpg?v=1571728320"},{"product_id":"uniblend-cpe-high-speed-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacket-medium-voltage-power-shielded-ul","title":"General Cable Uniblend® CPE High Speed Type MV-105 3C 220 Mils EPR Copper Tape Shield with Overall CPE Jacket Medium Voltage Power Shielded UL","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e 2 AWG thru 1000 kcmil annealed bare copper compact Class B strand\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Strand Shield (ESS):\u003c\/strong\u003e Extruded thermoset semi-conducting stresscontrol layer over conductor\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) insulation, contrasting in color to the black semi-conducting shield layers\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtruded Insulation Shield (EIS)\u003c\/strong\u003e: Thermoset semi-conducting polymeric layer free stripping from insulation\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMetallic Shield:\u003c\/strong\u003e 5 mil annealed copper tape with an overlap of 25%\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGrounding Conductor:\u003c\/strong\u003e 1 bare grounding conductor may be in contact with metallic shielding tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOverall Jacket:\u003c\/strong\u003e Lead-free, moisture- and sunlight-resistant Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e STRANDFILL® – blocked conductor. Tested in accordance with ICEA T-31-610\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • Suited for use in a broad range of commercial, industrial and utility applications, where reliability is the major concern, space is limited and ease of installation is critical\u003cbr\u003e • In wet or dry locations when installed in accordance with NEC\u003cbr\u003e • In aerial, direct burial, conduit, open tray and underground duct installations\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 105?C\u003cbr\u003e • Excellent heat and moisture resistance\u003cbr\u003e • Outstanding corona resistance\u003cbr\u003e • Flexibility for easy handling\u003cbr\u003e • Low friction for easy pulling\u003cbr\u003e • High dielectric strength\u003cbr\u003e • Low moisture absorption\u003cbr\u003e • Electrical stability under stress\u003cbr\u003e • Low dielectric loss\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Meets cold bend test at -35?C\u003cbr\u003e • 105°C rating for continuous operation\u003cbr\u003e • 140°C rating for emergency overload conditions\u003cbr\u003e • 250°C rating for short circuit conditions\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e • National Electrical Code (NEC)\u003cbr\u003e • UL 1072\u003cbr\u003e • ICEA S-93-639\/NEMA WC74\u003cbr\u003e • ICEA S-97-682\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • AEIC CS8\u003cbr\u003e • UL listed as Type MV-105 for use in accordance with NEC, UL File # E90501\u003cbr\u003e • UL 1685 (70,000 BTU\/hr)\u003cbr\u003e • OSHA Acceptable\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Flame Tests:\u003c\/strong\u003e IEEE 1202 (70,000 BTU\/hr)\/CSA FT4\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e\u003cbr\u003e • Material cut to length and shipped on non-returnable wood reels. Lengths in excess of 10,000 lbs. are provided on returnable steel reels that require a deposit\u003cbr\u003e • Extra charges apply for cuts less than 1000 ft., lagging, pulling eyes, paralleling and plexing\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.\u003cbr\u003e size\u003cbr\u003e (awg\/\u003cbr\u003e kcmil)\u003c\/td\u003e\n\u003ctd\u003enominal\u003cbr\u003e conductor\u003cbr\u003e diameter\u003c\/td\u003e\n\u003ctd\u003eampacity\u003c\/td\u003e\n\u003ctd\u003egeneral\u003cbr\u003e cable\u003cbr\u003e part\u003cbr\u003e number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e0.27\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003ctd\u003e15593.440205*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/15kv-medium-voltage-power-cable\/uniblend-cpe-high-speed-2-awg-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacket\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003ctd\u003e0.34\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003ctd\u003e15593.445105*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/15kv-medium-voltage-power-cable\/uniblend-cpe-high-speed-1-0-awg-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jack\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003ctd\u003e0.38\u003c\/td\u003e\n\u003ctd\u003e275\u003c\/td\u003e\n\u003ctd\u003e15593.445205*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/15kv-medium-voltage-power-cable\/uniblend-cpe-high-speed-2-0-awg-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jack\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003ctd\u003e0.48\u003c\/td\u003e\n\u003ctd\u003e360\u003c\/td\u003e\n\u003ctd\u003e15593.445405*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/15kv-medium-voltage-power-cable\/uniblend-cpe-high-speed-4-0-awg-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jack\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003e0.53\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e15593.446005*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/15kv-medium-voltage-power-cable\/uniblend-cpe-high-speed-250mcm-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacke\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003ctd\u003e0.62\u003c\/td\u003e\n\u003ctd\u003e490\u003c\/td\u003e\n\u003ctd\u003e15593.446205*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/15kv-medium-voltage-power-cable\/uniblend-cpe-high-speed-350mcm-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacke\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e0.74\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e15593.446505*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/15kv-medium-voltage-power-cable\/uniblend-cpe-high-speed-500mcm-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacke\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003ctd\u003e0.91\u003c\/td\u003e\n\u003ctd\u003e745\u003c\/td\u003e\n\u003ctd\u003e15593.447005*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/15kv-medium-voltage-power-cable\/uniblend-cpe-high-speed-750mcm-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacke\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e1.06\u003c\/td\u003e\n\u003ctd\u003e860\u003c\/td\u003e\n\u003ctd\u003e15593.447505*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/15kv-medium-voltage-power-cable\/uniblend-cpe-high-speed-1000mcm-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jack\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163775123519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_22cddd42-7d7e-4aed-af1c-0e52f9e74800.jpg?v=1571728321"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/general-cable-uniblend%c2%ae-cpe-high-speed-type-mv-105-3c-220-mils-epr-copper-tape-shield-with-overall-cpe-jacket-medium-voltage-power-shielded-ul.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}