{"title":"General Cable Type P Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"","products":[{"product_id":"type-p-1-awg-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 1 AWG 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e34.93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e537\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e799\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1456\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2167\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e174\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e186\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e356990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163494105151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_98cce44c-eba9-40ed-988c-342c951e0468.jpg?v=1571728229"},{"product_id":"type-p-1-awg-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 1 AWG 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e36.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e806\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1749\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2603\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e137\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e153\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e293880\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163494268991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_9ab19185-f6bd-468c-9197-de67a3762c9d.jpg?v=1571728229"},{"product_id":"type-p-1-awg-4-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 1 AWG 4 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.580\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e40.13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1222\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1818\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3169\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e302620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163494400063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_1911ce83-f470-4ed1-99ce-ca765485e36d.jpg?v=1571728229"},{"product_id":"type-p-1-awg-5-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 1 AWG 5 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e45.21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1343\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1998\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2658\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3955\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163494432831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_c73a6483-bff1-4981-8417-fe174fc85677.jpg?v=1571728229"},{"product_id":"type-p-1-0-awg-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 1\/0 AWG 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.450\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e36.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2559\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e213\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e278\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163495743551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_43c02bc1-a0a6-4ed6-844a-25dc0c2e96f9.jpg?v=1571728230"},{"product_id":"type-p-1-0-awg-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 1\/0 AWG 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.545\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e39.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1598\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e157\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e229\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e281230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163495776319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_71051bf1-bea9-43f1-85c2-7b7fd758bab3.jpg?v=1571728230"},{"product_id":"type-p-1-0-awg-4-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 1\/0 AWG 4 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e43.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1482\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2665\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e355660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163495907391,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_b6c8999e-ed74-42c4-82c9-18debc0356e4.jpg?v=1571728230"},{"product_id":"type-p-1-0-awg-5-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 1\/0 AWG 5 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.875\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e47.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1790\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4787\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e183\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163495940159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_46b2291f-577e-40fe-bdff-5d8e93d86eb8.jpg?v=1571728230"},{"product_id":"type-p-2-awg-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 2 AWG 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e30.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e388\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e577\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1643\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e149\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e196\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e326150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163516682303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_e4cc9c3c-78d8-4ac3-9744-6eb1777c5340.jpg?v=1571728233"},{"product_id":"type-p-2-awg-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 2 AWG 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e32.13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e581\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e865\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1323\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1969\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e281220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163518156863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_a69df884-83f6-451a-9e01-dd0f55d07df0.jpg?v=1571728233"},{"product_id":"type-p-2-awg-4-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 2 AWG 4 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.365\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e34.67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e775\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1153\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1584\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2357\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e302610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163520024639,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_5877c47a-397d-41a6-86e9-2ea0068d840d.jpg?v=1571728233"},{"product_id":"type-p-2-awg-5-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 2 AWG 5 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e37.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e969\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1442\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1917\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2852\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163520352319,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_c27bae79-cb19-46c5-9ff5-3caa7b9badd2.jpg?v=1571728233"},{"product_id":"type-p-2-0-awg-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 2\/0 AWG 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.565\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e39.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e830\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1981\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2948\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163535425599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_511e726c-7f42-4119-a70c-4260652ea394.jpg?v=1571728253"},{"product_id":"type-p-2-0-awg-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 2\/0 AWG 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e43.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1853\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e188\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e254\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e318840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163535982655,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_9436e332-95a0-4280-8dad-6fe4be0c934e.jpg?v=1571728253"},{"product_id":"type-p-2-0-awg-4-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 2\/0 AWG 4 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.875\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e47.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1661\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3052\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4541\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e302630\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163537555519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_505ac963-abed-49dd-b504-89c07ca3c551.jpg?v=1571728253"},{"product_id":"type-p-2-0-awg-5-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 2\/0 AWG 5 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e53.34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2076\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3089\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e5684\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e203\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163537752127,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_69afba3f-f141-4285-a09b-2a8fd64eec37.jpg?v=1571728253"},{"product_id":"type-p-262kcmil-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 262kcmil 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e51.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1618\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2408\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3515\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e5230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e358\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e378\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e481\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163538440255,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_7b49cd8e-bc37-4743-af96-175d78107314.jpg?v=1571728253"},{"product_id":"type-p-262kcmil-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 262Kcmil 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e54.48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2426\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e4318\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e6425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e283\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e294\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e395\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e293910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163539128383,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_grande_89e81fab-0002-4da9-b1a2-04feda665aa1.jpg?v=1571728253"},{"product_id":"type-p-262kcmil-4-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 262Kcmil 4 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e59.44\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3418\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e5086\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e5309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e7900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e248\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163541454911,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_83575db4-4500-466d-9cae-b32dd20f383f.jpg?v=1571728253"},{"product_id":"type-p-262kcmil-5-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 262Kcmil 5 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.560\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e65.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e4044\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e6017\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e6456\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e9607\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e226\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e248\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163542732863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_784fd165-ec82-4991-82bf-6bb30a9347ec.jpg?v=1571728253"},{"product_id":"type-p-3-awg-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 3 AWG 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"TYPE P 3 AWG 2 CORES ARMORED AND SHEATHED FLEXIBLE MULTI CONDUCTOR POWER MOR POLYRAD XT-125 600 V\/1000 V\u003cmeta name=\"Description\" content=\"Browse our Selection of TYPE P 3 AWG 2 CORES ARMORED AND SHEATHED FLEXIBLE MULTI CONDUCTOR POWER MOR POLYRAD XT-125 600 V\/1000 V - 356980. Click For a Free Quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Type P Cable, 3 AWG 2 CORES Polyrad Cable, 3 AWG 2 CORES Polyrad XT-125 Cable, Armored Cable, Sheathed Cable, 3 AWG 2 CORES Multi Conductor Power Cable, Type P Polyrad XT-125 600 V\/1000 V Cable, Type P Armored Cable Price, Type P Armored Cable Quote, Polyrad XT-125 Cable Price, Polyrad XT-125 Cable Quote\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e28.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e337\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e356980\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163542896703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_011ef5d5-71ed-424e-bfff-9b6888a316ae.jpg?v=1571728253"},{"product_id":"type-p-3-awg-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 3 AWG 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.215\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e30.86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e751\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1793\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e148\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163542929471,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_83f7c25a-d29c-47c5-b690-825419c65d0d.jpg?v=1571728253"},{"product_id":"type-p-3-awg-4-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 3 AWG 4 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e33.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e673\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1435\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2135\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163543158847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_4ed56881-c380-4fd7-a747-2a340c49c8d1.jpg?v=1571728253"},{"product_id":"type-p-3-awg-5-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 3 AWG 5 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e36.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e842\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1724\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2565\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e86\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163543846975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_90cc672f-54cb-4fca-b80b-6b50998c56ac.jpg?v=1571728253"},{"product_id":"type-p-3-0-awg-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 3\/0 AWG 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.795\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e45.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1193\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1775\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2665\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3966\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e265\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e284\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e286660\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163543978047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_e74b4ed2-85bb-462c-8484-9aa555dba979.jpg?v=1571728253"},{"product_id":"type-p-3-0-awg-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 3\/0 AWG 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.865\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e47.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1790\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4616\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e209\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e218\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e286670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163544010815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1fa86e54-b34e-4fce-9726-01adf6887f90.jpg?v=1571728253"},{"product_id":"type-p-3-0-awg-4-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 3\/0 AWG 4 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e54.10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2389\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3555\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e4117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e6126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e167\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e174\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e186\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e302640\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163545092159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_d2e88232-ebd8-4155-9574-c8cc86592df2.jpg?v=1571728253"},{"product_id":"type-p-3-0-awg-5-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 3\/0 AWG 5 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e58.93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2984\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e4989\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e7424\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e167\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e174\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e186\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163545976895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_6e98a34a-da84-416a-9f22-45adafb64efb.jpg?v=1571728254"},{"product_id":"type-p-313kcmil-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 313kcmil 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e54.61\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1878\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2794\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3951\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e5879\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e378\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e391\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e539\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163546239039,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_8c141d00-1267-45d8-92c4-c3f7e621a148.jpg?v=1571728254"},{"product_id":"type-p-313kcmil-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 313Kcmil 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e57.28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2817\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e4877\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e7257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e345\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e442\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e286680\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163546271807,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_4fa70398-c431-45de-a818-01c1c6befa2a.jpg?v=1571728254"},{"product_id":"type-p-313kcmil-4-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 313Kcmil 4 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e62.74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3756\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e5589\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e5983\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e8903\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e354\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163546533951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_dad7d65c-4af5-434e-b170-1043001b6bc6.jpg?v=1571728254"},{"product_id":"type-p-313kcmil-5-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 313Kcmil 5 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e313\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.765\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e70.23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e4695\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e6986\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e7472\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e11118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e247\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e257\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e276\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e354\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163546566719,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_360d4e89-fea3-4312-a764-208aef0a35d9.jpg?v=1571728254"},{"product_id":"type-p-373kcmil-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 373kcmil 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e373\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e57.66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2231\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e4511\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e6712\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e456\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e497\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e599\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e387840\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163546697791,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_805de43f-325a-4626-ac69-c8d15e5c5978.jpg?v=1571728254"},{"product_id":"type-p-373kcmil-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 373Kcmil 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e373\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e60.96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3346\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4979\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e5602\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e8336\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e361\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e406\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e492\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e316610\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163546861631,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_4ca1fe96-2d70-446b-b52a-f058a2da1b06.jpg?v=1571728254"},{"product_id":"type-p-373kcmil-4-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 373Kcmil 4 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e373\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.625\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e66.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e4461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e6638\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e6911\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e10284\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e289\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163547091007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_36860a19-0ce3-4da8-a08c-85c0ecde0657.jpg?v=1571728254"},{"product_id":"type-p-373kcmil-5-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 373Kcmil 5 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e373\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e74.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e5576\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e8297\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e8592\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e12785\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e289\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163547123775,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_d14d94b3-b2cc-40b4-9278-c94fa2dcee01.jpg?v=1571728254"},{"product_id":"type-p-4-awg-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 4 AWG 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"TYPE P 4 AWG 2 CORES ARMORED AND SHEATHED FLEXIBLE MULTI CONDUCTOR POWER MOR POLYRAD XT-125 600 V\/1000 V\u003cmeta name=\"Description\" content=\"Browse our Selection of TYPE P 4 AWG 2 CORES ARMORED AND SHEATHED FLEXIBLE MULTI CONDUCTOR POWER MOR POLYRAD XT-125 600 V\/1000 V - 321820. Click For a Free Quote.\"\u003e\u003cmeta name=\"Keywords\" content=\"Type P Cable, 4 AWG 2 CORES Polyrad Cable, 4 AWG 2 CORES Polyrad XT-125 Cable, Armored Cable, Sheathed Cable, 4 AWG 2 CORES Multi Conductor Power Cable, Type P Polyrad XT-125 600 V\/1000 V Cable, Type P Armored Cable Price, Type P Armored Cable Quote, Polyrad XT-125 Cable Price, Polyrad XT-125 Cable Quote\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e28.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e249\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e371\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e871\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1296\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e105\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e153\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e321820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163547189311,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_2f4d446d-4c45-443b-9685-450cda998375.jpg?v=1571728254"},{"product_id":"type-p-4-awg-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 4 AWG 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e29.46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e374\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e557\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1027\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1528\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e126\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd style=\"text-align: left;\"\u003e287700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163547287615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_d98dd34a-b02c-4bd5-a302-7a95afdaa897.jpg?v=1571728254"},{"product_id":"type-p-4-awg-4-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 4 AWG 4 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.255\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e31.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e499\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e743\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1792\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e291730\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163547353151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_5d055a2c-4173-4556-b6ad-0d43a215e147.jpg?v=1571728254"},{"product_id":"type-p-4-awg-5-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 4 AWG 5 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.360\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e34.54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e623\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e927\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1441\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163547451455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_33ad366c-c393-41b3-8f18-7f4a1be56caa.jpg?v=1571728254"},{"product_id":"type-p-4-0-awg-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 4\/0 AWG 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.860\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e47.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1994\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2911\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4332\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e295\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e307\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e432\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163547516991,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_88354828-4340-4c19-9d05-bda81ae41c05.jpg?v=1571728254"},{"product_id":"type-p-4-0-awg-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 4\/0 AWG 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e51.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2989\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3689\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e5489\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e242\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e252\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e270\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e354\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e326160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163547549759,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_d234d0be-5f72-40eb-93ec-82b429184232.jpg?v=1571728254"},{"product_id":"type-p-4-0-awg-4-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 4\/0 AWG 4 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e56.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2679\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3986\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e4521\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e6727\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e194\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e283\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e296180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163547680831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_fea69999-dce6-4dcd-ac1b-db2a5e1cfa29.jpg?v=1571728254"},{"product_id":"type-p-4-0-awg-5-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 4\/0 AWG 5 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e61.09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3349\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4983\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e5478\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e8151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e194\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e283\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163547713599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_f93d65ef-6d0a-4304-9c9c-27f71fc1dcbe.jpg?v=1571728255"},{"product_id":"type-p-444kcmil-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 444kcmil 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e444\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e60.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2691\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e5157\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e7674\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e486\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e556\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e669\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e387850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163550924863,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_30e2ff7a-c21c-437f-a4cf-3ee5b853da7c.jpg?v=1571728255"},{"product_id":"type-p-444kcmil-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 444Kcmil 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e444\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e63.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e4037\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e6007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e6466\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e9621\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e396\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e454\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e549\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357070\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163551055935,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_2fc9e867-c76d-4cc5-bf2c-d03af14a5ad5.jpg?v=1571728255"},{"product_id":"type-p-444kcmil-4-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 444Kcmil 4 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e444\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e2.800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e71.12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e5382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e8008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e8159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e12141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e317\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e363\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e439\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e14444.046400²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163551350847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_812f0b45-ab5d-4f95-84de-ad35b1c50b2d.jpg?v=1571728255"},{"product_id":"type-p-444kcmil-5-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 444Kcmil 5 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e444\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e3.145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e79.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e6728\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e10011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e10100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e15029\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e317\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e329\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e363\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e439\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e14444.056400²\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163551383615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_bf08b125-c66c-4cda-ac23-20be404e834b.jpg?v=1571728255"},{"product_id":"type-p-5-awg-2-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 5 AWG 2 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e26.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e233\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e347\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e777\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1156\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e109\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e147\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e356970\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163551449151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_6e6dd40e-35a6-4f63-a7b4-1d1469a89776.jpg?v=1571728255"},{"product_id":"type-p-5-awg-3-cores-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad-xt-125-600-v-1000-v","title":"General Cable Type P 5 AWG 3 Cores Armored and Sheathed Flexible Multi Conductor Power MOR Polyrad® XT-125 600 V\/1000 V","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor: \u003c\/strong\u003e 8 AWG thru 777 kcmil soft annealed tinned copper flexible strand \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e \u003cbr\u003e • Polyrad® XT-125 Irradiated Cross-linked Polyolefin (XLPO) \u003cbr\u003e • Color Code: Per IEEE 1580 Table 22 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Core: \u003c\/strong\u003e\u003cbr\u003e • Cabled with fillers when required \u003cbr\u003e • Core binder tape when required \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Bronze braid 88% minimum coverage \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSheath: \u003c\/strong\u003eMud Oil-Resistant, Black Irradiated Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Offshore oil and gas drilling platforms, MODUs, ships and FPSOs \u003cbr\u003e • Land-based oil and gas drilling rigs \u003cbr\u003e • Suitable for use in Class I, Division 1 and Zone 1 Hazardous Locations when installed in accordance with API-RP14F \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Meets NEK 606 mud oil resistance requirements with ester-based muds \u003cbr\u003e • Meets UL 2225 crush and impact requirements of Type MC-HL cables \u003cbr\u003e • Flexible stranding to facilitate ease of cable installation and termination \u003cbr\u003e • Temperature rated @ 125°C for long life, higher ampacities and protection from thermal overloads \u003cbr\u003e • Meets cold bend test at -55°C \u003cbr\u003e • Meets cold impact test at -40°\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry: \u003c\/strong\u003e\u003cbr\u003e • API-RP14F \u003cbr\u003e • CSA C22.2 No. 245 Type X110 \u003cbr\u003e • IEEE 1580-2010 Type P \u003cbr\u003e • IEC 60092-350 \u003cbr\u003e • Mud oil-resistant \u003cbr\u003e • UL 1309 Type X110 \u003cbr\u003e • UL Listed 110°C Marine Shipboard Cable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test:\u003c\/strong\u003e \u003cbr\u003e • IEEE 1202 \u003cbr\u003e • IEC 60332-3-22 Cat. A (supersedes IEC 60332-3A) \u003cbr\u003e • CSA C22.2 No. 0.3 FT4\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.size(awg)\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e# of cores\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e28.58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight (lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e349\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e519\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e951\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight (kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(95°c)\u003c\/td\u003e\n\u003ctd\u003e78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked (100°c)\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(110°c)\u003c\/td\u003e\n\u003ctd\u003e88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eampacities1 45°c ambient-single banked(125°c)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003ecatalog number\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e357050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7163551547455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_e7301e26-735a-4679-9576-d4264549c983.jpg?v=1571728255"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/Nassau-lg_39279bc0-518e-481a-bbe9-f768bb0dc820.jpg?v=1525246677","url":"https:\/\/www.nassauelectrical.com\/collections\/general-cable-type-p-armored-and-sheathed-flexible-multi-conductor-power-mor-polyrad%c2%ae-xt-125-600-v-1000-v.oembed?page=3","provider":"NassauElectrical","version":"1.0","type":"link"}