{"title":"General Cable SunGen® Dual-Layer EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper","description":"","products":[{"product_id":"sungen-dual-layer-1-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 1 Gauge EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 1 Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 1 Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 1 Gauge,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e19\/.0664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.323\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e8.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.561\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e14.25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e258\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e655\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.710100*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301089656895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_10effc86-1fc9-4868-a245-ce0012ddec38.jpg?v=1571729392"},{"product_id":"sungen-dual-layer-1-0-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 1\/0 Gauge EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 1\/0 Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 1\/0 Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 1\/0 Gauge,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e19\/.0740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.370\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e9.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.607\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e751\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.715100*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301089722431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_25644e35-cb96-44ec-bd6b-b133697f35e9.jpg?v=1571729392"},{"product_id":"sungen-dual-layer-10-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 10 gauge EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e19\/.0234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e2.84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.273\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e6.93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.711100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301089787967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_f22736b8-46fd-49cd-aec5-2ad01e71f46d.jpg?v=1571729392"},{"product_id":"sungen-dual-layer-1000mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 1000MCM EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 1000MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 1000MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 1000MCM,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e61\/.1280\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e28.37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.473\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e37.41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3088\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4595\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e3564\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e5303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.717000*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301089820735,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_0af75604-3639-4538-b21b-34dd661f8b97.jpg?v=1571729392"},{"product_id":"sungen-dual-layer-12-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 12 gauge EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd. size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e19\/.0185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.088\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e2.23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e6.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.711200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301089853503,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_db38cc1b-2562-48ef-8485-088b7c773a67.jpg?v=1571729392"},{"product_id":"sungen-dual-layer-14-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 14 gauge EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e19\/.0142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.070\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e1.78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e5.89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.711400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301090148415,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_ee63b694-4b55-4cc0-9f60-843adb91a68e.jpg?v=1571729392"},{"product_id":"sungen-dual-layer-2-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 2 Gauge EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 2 Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 2 Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 2 Gauge,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e19\/.0526\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.296\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e7.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.507\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e12.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e305\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e306\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e455\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.710200*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301090181183,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_ac3ba9a3-7ac1-44bb-91e4-b5511918286c.jpg?v=1571729392"},{"product_id":"sungen-dual-layer-2-0-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 2\/0 Gauge EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 2\/0 Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 2\/0  Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 2\/0 Gauge,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e19\/.0837\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e10.41\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.652\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e16.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e611\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e615\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.715200*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301090213951,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_abd5f58f-ddf6-46a8-9d22-80af5c5f0cea.jpg?v=1571729392"},{"product_id":"sungen-dual-layer-250mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 250MCM EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 250MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 250MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 250MCM,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e37\/.0822\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.558\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e14.17\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.075\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.882\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e22.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e772\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1149\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1506\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.716250*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301090672703,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_b1cc34df-d855-4b0b-b64f-b42b042c952e.jpg?v=1571729392"},{"product_id":"sungen-dual-layer-3-0-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 3\/0 Gauge EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 3\/0 Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 3\/0  Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 3\/0 Gauge,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e19\/.0940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e11.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e17.78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e518\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e771\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e747\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.715300*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301092245567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_27318090-5d1d-466b-8f3d-d714b7e02f3f.jpg?v=1571729392"},{"product_id":"sungen-dual-layer-300mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 300MCM EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 300MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 300MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 300MCM,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e37\/.0900\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.611\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e15.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.075\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.935\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e23.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e926\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1378\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1184\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1763\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.716350*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301093228607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_cd74afd1-cf41-47a9-b041-3e670984967a.jpg?v=1571729392"},{"product_id":"sungen-dual-layer-350mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 350MCM EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 350MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 350MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 350MCM,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e37\/.0972\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.611\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e16.79\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.075\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.985\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e25.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1063\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1582\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1339\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1993\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.716350*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301093621823,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_627fdf2b-fede-473d-937d-a1ca838177f5.jpg?v=1571729392"},{"product_id":"sungen-dual-layer-4-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 4 Gauge EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 4 Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 4 Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 4 Gauge,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e19\/.0469\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e5.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.442\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e11.23\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e208\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e309\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.710400*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301093654591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_6248619e-4132-4dee-b30c-0421daaac32a.jpg?v=1571729393"},{"product_id":"sungen-dual-layer-4-0-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 4\/0 Gauge EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 4\/0 Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 4\/0  Gauge EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 4\/0 Gauge,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e19\/.1055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.520\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e13.21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.065\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e19.30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e653\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e972\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e891\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.715400*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301093752895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_6f1952d6-c91c-463a-b488-287b3f868220.jpg?v=1571729393"},{"product_id":"sungen-dual-layer-400mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 400MCM EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 400MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 400MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 400MCM,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e37\/.1040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.706\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e17.93\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.075\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e26.16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1235\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1838\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1527\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2273\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.716400*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301093851199,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_6b1c23ad-cd62-4575-968f-88a02f8efd88.jpg?v=1571729393"},{"product_id":"sungen-dual-layer-500mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 500MCM EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 500MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 500MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 500MCM,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e37\/.1159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e20.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.075\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e28.27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1509\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2246\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1831\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2725\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.716500*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301093883967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_6fd7c00d-f076-41d1-a371-767bc6519f21.jpg?v=1571729393"},{"product_id":"sungen-dual-layer-6-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 6 gauge EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e19\/.0372\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.184\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e4.67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.398\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e148\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.710600*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301093916735,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_6a305607-59c6-4682-98df-edd82f7225d5.jpg?v=1571729393"},{"product_id":"sungen-dual-layer-600mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 600MCM EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 600MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 600MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 600MCM,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e61\/.0992\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.866\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e22.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.222\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e31.04\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1883\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3367\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.716600*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301093949503,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_8862975b-8634-46a4-996e-c8c528aee3a7.jpg?v=1571729393"},{"product_id":"sungen-dual-layer-750mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 750MCM EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"SunGen Dual-Layer 750MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\u003cmeta name=\"Description\" content=\"SunGen Dual-Layer 750MCM EPR\/XL-CPE Photovoltaic Wire 2000 V UL Type PV\/RHH or RHW-2 or 600 V USE-2 Single Conductor Copper\"\u003e\u003cmeta name=\"Keywords\" content=\"SunGen Dual-Layer 750MCM,SunGen, SunGen Dual-Layer, Dual-Layer EPR\/XL-CPE, Photovoltaic Wire, Photovoltaic Wire 2000 V UL,Type PV\/RHH, Type RHW-2, Type PV\/RHH or RHW-2 or 600 V USE-2, 600 V USE-2, Single Conductor Copper Wire.\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e61\/.1109\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.968\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e24.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e1.324\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e33.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2316\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3447\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e2734\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e4069\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e12221.716750*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301094113343,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_559e047e-f43c-4b32-95fe-5653f87e54c3.jpg?v=1571729393"},{"product_id":"sungen-dual-layer-8-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer 8 gauge EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8 \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Bare copper conductor \u003cbr\u003e • Other stranding options are available upon request \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Rated 90°C wet and dry \u003cbr\u003e • Rated for direct burial \u003cbr\u003e • Deformation-resistant at high temperatures \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44 \u003cbr\u003e • Stable electrical properties over a broad temperature range \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction  \u003cbr\u003e • Increased flexibility \u003cbr\u003e • Resistant to most oils and chemicals \u003cbr\u003e • UV\/sunlight-resistant \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 4703 Type PV, UL File # E323451 \u003cbr\u003e • National Electrical Code (NEC) \u003cbr\u003e • ICEA S-95-658\/NEMA WC70 \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260 \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307 \u003cbr\u003e • Limited Smoke Rating per UL \u003cbr\u003e • RoHS Compliant \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e \u003cbr\u003e • UL 1581 VW-1 \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4 \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e: \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003econd.size(awg\/kcmil)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd.strand\u003c\/td\u003e\n\u003ctd\u003e19\/.0295\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cond. o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e3.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.055\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg.jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eminimum avg.jacket thickness(mm)\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(inches)\u003c\/td\u003e\n\u003ctd\u003e0.332\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e8.43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopperweight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalognumber\u003c\/td\u003e\n\u003ctd\u003e12221.710800*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301094146111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_470x_b243cf2b-c9fd-419c-ab02-f9e73dd5d8b5.jpg?v=1571729393"},{"product_id":"sungen-dual-layer-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper","title":"General Cable SunGen® Dual-Layer EPR\/XL-CPE Photovoltaic Wire 2000V UL Type PV\/RHH or RHW-2 or 600V USE-2 Single Conductor Copper","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e  \u003cbr\u003e • 14 AWG thru 2 AWG tinned coated compressed copper. Class C stranding per ASTM B33 and B8  \u003cbr\u003e • 1 AWG thru 1000 kcmil tinned coated compressed copper. Class B stranding per ASTM B33 and B8 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e Lead-free Ethylene Propylene Rubber (EPR) colored for contrast with black jacket \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket:\u003c\/strong\u003e Black, lead-free, flame-retardant, oil-, chemicaland sunlight-resistant Cross-linked Chlorinated Polyethylene (XL-CPE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e  \u003cbr\u003e • Bare copper conductor  \u003cbr\u003e • Other stranding options are available upon request  \u003cbr\u003e • Now available in colors \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Single conductor, sunlight-resistant, direct burial photovoltaic wire rated 90°C wet or dry, 2000 V for interconnection wiring of grounded and ungrounded photovoltaic power systems as described in Section 690.31(A) and other applicable parts of the National Electrical Code (NEC), NFPA 70 \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e  \u003cbr\u003e • Rated 90°C wet and dry  \u003cbr\u003e • Rated for direct burial  \u003cbr\u003e • Deformation-resistant at high temperatures  \u003cbr\u003e • Excellent moisture resistance, exceeds UL 44  \u003cbr\u003e • Stable electrical properties over a broad temperature range  \u003cbr\u003e • Extra tough, mechanically rugged dual-layer construction   \u003cbr\u003e • Increased flexibility  \u003cbr\u003e • Resistant to most oils and chemicals  \u003cbr\u003e • UV\/sunlight-resistant  \u003cbr\u003e • Meets cold bend and cold impact tests at -40°C \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances: \u003c\/strong\u003e \u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e  \u003cbr\u003e • UL 4703 Type PV, UL File # E323451  \u003cbr\u003e • National Electrical Code (NEC)  \u003cbr\u003e • ICEA S-95-658\/NEMA WC70  \u003cbr\u003e • UL 44 Type RHH or RHW-2, UL File # E90494 or E54260  \u003cbr\u003e • UL 854 Type USE-2 for 600 V, UL File # E90499 or E86307  \u003cbr\u003e • Limited Smoke Rating per UL  \u003cbr\u003e • RoHS Compliant  \u003cbr\u003e \u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e  \u003cbr\u003e • UL 1581 VW-1  \u003cbr\u003e • For sizes 1\/0 and larger: IEEE 383, IEEE 1202\/CSA FT4  \u003cbr\u003e \u003cstrong\u003eOther Compliances\u003c\/strong\u003e:  \u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP  \u003cbr\u003e • OSHA Acceptable \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003econd.size(awg\/kcmil)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003econd.strand\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003enet weight\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003egeneral cable \u003cbr\u003e part number\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd style=\"color: #ffffff;\"\u003elbs\/1000 ft\u003c\/td\u003e\n\u003ctd style=\"color: #ffffff;\"\u003ekg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e19\/.0142\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003ctd\u003e54\u003c\/td\u003e\n\u003ctd\u003e12221.711400\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-14-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-sing\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e19\/.0185\u003c\/td\u003e\n\u003ctd\u003e46\u003c\/td\u003e\n\u003ctd\u003e68\u003c\/td\u003e\n\u003ctd\u003e12221.711200\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-12-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-sing\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e19\/.0234\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e12221.711100\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-10-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-sing\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e19\/.0295\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003ctd\u003e12221.710800*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-8-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-singl\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e19\/.0372\u003c\/td\u003e\n\u003ctd\u003e148\u003c\/td\u003e\n\u003ctd\u003e220\u003c\/td\u003e\n\u003ctd\u003e12221.710600*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-6-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-singl\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e19\/.0469\u003c\/td\u003e\n\u003ctd\u003e208\u003c\/td\u003e\n\u003ctd\u003e309\u003c\/td\u003e\n\u003ctd\u003e12221.710400*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-4-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e19\/.0526\u003c\/td\u003e\n\u003ctd\u003e306\u003c\/td\u003e\n\u003ctd\u003e455\u003c\/td\u003e\n\u003ctd\u003e12221.710200*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-2-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e19\/.0664\u003c\/td\u003e\n\u003ctd\u003e440\u003c\/td\u003e\n\u003ctd\u003e655\u003c\/td\u003e\n\u003ctd\u003e12221.710100*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-1-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\/0\u003c\/td\u003e\n\u003ctd\u003e19\/.0740\u003c\/td\u003e\n\u003ctd\u003e505\u003c\/td\u003e\n\u003ctd\u003e751\u003c\/td\u003e\n\u003ctd\u003e12221.715100*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-1-0-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\/0\u003c\/td\u003e\n\u003ctd\u003e19\/.0837\u003c\/td\u003e\n\u003ctd\u003e615\u003c\/td\u003e\n\u003ctd\u003e915\u003c\/td\u003e\n\u003ctd\u003e12221.715200*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-2-0-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\/0\u003c\/td\u003e\n\u003ctd\u003e19\/.0940\u003c\/td\u003e\n\u003ctd\u003e747\u003c\/td\u003e\n\u003ctd\u003e1111\u003c\/td\u003e\n\u003ctd\u003e12221.715300*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-3-0-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\/0\u003c\/td\u003e\n\u003ctd\u003e19\/.1055\u003c\/td\u003e\n\u003ctd\u003e891\u003c\/td\u003e\n\u003ctd\u003e1326\u003c\/td\u003e\n\u003ctd\u003e12221.715400*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-4-0-gauge-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e250\u003c\/td\u003e\n\u003ctd\u003e37\/.0822\u003c\/td\u003e\n\u003ctd\u003e1012\u003c\/td\u003e\n\u003ctd\u003e1506\u003c\/td\u003e\n\u003ctd\u003e12221.716250*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-250mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e37\/.0900\u003c\/td\u003e\n\u003ctd\u003e1184\u003c\/td\u003e\n\u003ctd\u003e1763\u003c\/td\u003e\n\u003ctd\u003e12221.716300*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-300mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e350\u003c\/td\u003e\n\u003ctd\u003e37\/.0972\u003c\/td\u003e\n\u003ctd\u003e1339\u003c\/td\u003e\n\u003ctd\u003e1993\u003c\/td\u003e\n\u003ctd\u003e12221.716350*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-350mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e37\/.1040\u003c\/td\u003e\n\u003ctd\u003e1527\u003c\/td\u003e\n\u003ctd\u003e2273\u003c\/td\u003e\n\u003ctd\u003e12221.716400*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-400mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e500\u003c\/td\u003e\n\u003ctd\u003e37\/.1159\u003c\/td\u003e\n\u003ctd\u003e1831\u003c\/td\u003e\n\u003ctd\u003e2725\u003c\/td\u003e\n\u003ctd\u003e12221.716500*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-500mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003ctd\u003e61\/.0992\u003c\/td\u003e\n\u003ctd\u003e2262\u003c\/td\u003e\n\u003ctd\u003e3367\u003c\/td\u003e\n\u003ctd\u003e12221.716600*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-600mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003ctd\u003e61\/.1109\u003c\/td\u003e\n\u003ctd\u003e2734\u003c\/td\u003e\n\u003ctd\u003e4069\u003c\/td\u003e\n\u003ctd\u003e12221.716750*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-750mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e61\/.1280\u003c\/td\u003e\n\u003ctd\u003e3564\u003c\/td\u003e\n\u003ctd\u003e5303\u003c\/td\u003e\n\u003ctd\u003e12221.717000*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/copper-photovoltaic-cable\/sungen-dual-layer-1000mcm-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7301094211647,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_beb7e0be-2428-4e7e-ab58-961d2f02e29c.jpg?v=1571729393"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/general-cable-sungen%c2%ae-dual-layer-epr-xl-cpe-photovoltaic-wire-2000-v-ul-type-pv-rhh-or-rhw-2-or-600-v-use-2-single-conductor-copper.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}