{"title":"General Cable Polyrad® LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV","description":"","products":[{"product_id":"polyrad®-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv-or-1-8-3kv","title":"General Cable Polyrad® LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003eIt Coming with a black insulation, this cable comprises of a flexible conductor, class 5 stranded tinned copper per IEC 60228. Its insulation is a halogen free 90\u003csup\u003e0\u003c\/sup\u003e c low smoke irradiated cross linked polyolefin (EI 106 to EI 109). On the cable you will find markings with the manufacturer’s name, conductor size, lot number, EN reference, insulation code designation per Annex A of EN 50264-3-1 and voltage rating. It is ideal for use in auxiliary and electric heating circuits, lighting circuits powered by accumulator and equipment control and monitoring circuits. It gone through the following tests and is thus safe for use;\u003c\/p\u003e\n\u003cp\u003e1.EN 60684-2: No Fluorine \u003cbr\u003e2.EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e3.EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e4.EN 60811-1-4: Cold Bend (-40˚C) \u003cbr\u003e5.EN 60811-2-1: Resistant to Mineral Oil\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003cbr\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\"\u003ecross-sectional area\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eweight\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003egeneral cable part number\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd style=\"color: #ffffff;\"\u003emm²\u003c\/td\u003e\n\u003ctd style=\"color: #ffffff;\"\u003ecopper kg\/km\u003c\/td\u003e\n\u003ctd style=\"color: #ffffff;\"\u003ecable kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003emedium wall, single core unsheathed – 0,6\/1 kv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-1-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimens\"\u003e412300\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-1-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimens\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-1-5-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003e412310\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-1-5-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e31\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-2-5-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003e412320\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-2-5-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e45\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-4-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimens\"\u003e412330\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-4-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimens\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-6-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimens\"\u003e412340\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-6-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimens\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-10-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003e412370\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-10-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e156\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-16-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003e412380\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-16-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003ctd\u003e238\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-25-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003e412390\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-25-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e292\u003c\/td\u003e\n\u003ctd\u003e330\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-35-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003e412400\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-35-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e418\u003c\/td\u003e\n\u003ctd\u003e462\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-50-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003e412410\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-50-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003e596\u003c\/td\u003e\n\u003ctd\u003e658\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-70-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003e412420\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-70-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e795\u003c\/td\u003e\n\u003ctd\u003e860\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-95-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003e412430\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-95-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimen\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e1003\u003c\/td\u003e\n\u003ctd\u003e1080\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-120-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003e412440\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-120-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e1245\u003c\/td\u003e\n\u003ctd\u003e1367\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-150-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003e412450\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-150-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003ctd\u003e1556\u003c\/td\u003e\n\u003ctd\u003e1690\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-185-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003e412460\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-185-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003ctd\u003e2030\u003c\/td\u003e\n\u003ctd\u003e2234\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-240-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003e412470\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-240-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e2571\u003c\/td\u003e\n\u003ctd\u003e2780\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-300-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003e412480\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-300-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e3382\u003c\/td\u003e\n\u003ctd\u003e3735\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-400-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003e412490\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-400-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\" style=\"text-align: center;\"\u003emedium wall, single core unsheathed – 1,8\/3 kv\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e51\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-1-5-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003e412500\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-1-5-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-2-5-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003e412510\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-2-5-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e83\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-4-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime-1\"\u003e412520\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-4-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003e104\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-6-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime-1\"\u003e412530\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-6-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dime-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-10-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003e412540\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-10-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e215\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-16-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003e412550\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-16-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003ctd\u003e293\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-25-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003e412570\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-25-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e292\u003c\/td\u003e\n\u003ctd\u003e390\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-35-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003e412580\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-35-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e418\u003c\/td\u003e\n\u003ctd\u003e525\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-50-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003e412590\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-50-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003ctd\u003e596\u003c\/td\u003e\n\u003ctd\u003e720\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-70-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003e412610\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-70-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e795\u003c\/td\u003e\n\u003ctd\u003e935\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-95-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003e412620\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-95-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dim-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003ctd\u003e1003\u003c\/td\u003e\n\u003ctd\u003e1155\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-120-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003e412630\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-120-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003ctd\u003e1245\u003c\/td\u003e\n\u003ctd\u003e1443\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-150-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003e412640\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-150-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003ctd\u003e1556\u003c\/td\u003e\n\u003ctd\u003e1760\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/www.nassauelectrical.com\/products\/polyrad-185-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv\"\u003e412650\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"https:\/\/www.nassauelectrical.com\/products\/polyrad-185-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003ctd\u003e2030\u003c\/td\u003e\n\u003ctd\u003e2350\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-240-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003e412670\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-240-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e2571\u003c\/td\u003e\n\u003ctd\u003e2350\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-300-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003e412680\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-300-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e3382\u003c\/td\u003e\n\u003ctd\u003e3734\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-400-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003e412690\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/low-smoke-halogen-free-cable\/polyrad-400-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-di-1\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152039624767,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_6e611e49-d497-470b-821f-91c7539a6f3f.jpg?v=1571727344"},{"product_id":"polyrad-1-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 1 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 1 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 1 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 1 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e32 x 0.20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e20.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e14\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412300\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185746100287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg.jpg?v=1571728837"},{"product_id":"polyrad-1-5-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 1.5 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 1.5 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 1.5 CSA , Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 1.5 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e28 x 0.25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.52\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e3.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e13.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e13\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412310\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185747050559,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_3b4fcbb6-5cc9-4d3c-8210-607bb3c19ab0.jpg?v=1571728837"},{"product_id":"polyrad-1-5-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 1.5 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 1.5 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy our Product Polyrad 1.5 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,8\/1kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 1.5 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e1.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e28 x 0.25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.52\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e5.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e6.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e13.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e13\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e51\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412500\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185747214399,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_f9427ce0-dc9a-4c29-82b8-e751d9bcb472.jpg?v=1571728837"},{"product_id":"polyrad-10-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 10 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 10 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 10 CSA , Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 10 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e10\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e80 x 0.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e4.09\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e5.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e5.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1.95\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e89\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e110\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412370\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185747607615,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_10914c81-ee15-4784-9716-ba96cc31ce80.jpg?v=1571728837"},{"product_id":"polyrad-10-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 10 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 10 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy our Product Polyrad 10 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 10 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e10\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e80 x 0.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e4.09\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e7.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e8.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1.95\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e89\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e150\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412540\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185747640383,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_cc3fad3c-3007-4ab3-88d6-881de4c38388.jpg?v=1571728837"},{"product_id":"polyrad-120-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 120 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 120 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV\u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 120 CSA , Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 120 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e120\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e551 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e15.18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e15.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e18.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.164\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1003\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1080\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412440\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185751474239,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_db5a5a3e-1775-4531-9264-0261ebe3394a.jpg?v=1571728837"},{"product_id":"polyrad-120-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 120 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 120 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our Product Polyrad 120 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 120 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e120\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e551 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e15.18\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e17.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e20.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.164\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1003\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1155\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412630\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185751572543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_ade8348f-b2a7-455f-86d6-94b2f3b2487b.jpg?v=1571728837"},{"product_id":"polyrad-150-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 150 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 150 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 150 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 150 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e150\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e684 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e16.92\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e17.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e20.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.132\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1245\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1367\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412450\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185751998527,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_95bcf51e-4570-4671-a65e-f8dc468c71d0.jpg?v=1571728838"},{"product_id":"polyrad-150-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 150 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 150 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our Product Polyrad 150 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 150 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e150\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e684 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e16.92\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e19.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e22.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.132\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1245\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1443\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412640\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185752031295,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_b0c1e5ab-bc28-41bc-8908-41f274328ed8.jpg?v=1571728838"},{"product_id":"polyrad-16-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 16 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 16 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 16 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 16 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e16\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e126 x 0.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e5.33\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e6.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e7.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1.24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e142\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e156\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412380\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185752162367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_d1083c7a-1bc6-4807-a8e0-8a6fbce2f077.jpg?v=1571728838"},{"product_id":"polyrad-16-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 16 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 16 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our Product Polyrad 16 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 16 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e16\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e126 x 0.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e5.33\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e8.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e10.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1.24\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e142\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e215\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412550\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185752293439,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_64c61fd4-7f50-46da-8363-294c2fb490af.jpg?v=1571728838"},{"product_id":"polyrad-185-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 185 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 185 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 185 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 185 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e185\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e851 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e18.93\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e19.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e22.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.108\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1556\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1690\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412460\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185752490047,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_6800841b-7d51-44ca-8a55-79576e6b695c.jpg?v=1571728838"},{"product_id":"polyrad-185-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 185 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 185 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our Product Polyrad 185 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 185 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e185\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e851 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e18.93\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e20.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e24.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.108\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1556\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e1760\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412650\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185752588351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_606bacac-d3e7-46c7-9e67-6964fd42df0b.jpg?v=1571728838"},{"product_id":"polyrad-2-5-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 2.5 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 2.5 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 2.5 CSA , Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 2.5 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e2.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e46 x 0.25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.93\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e3.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e3.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e8.21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e20\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e31\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412320\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185756422207,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_7e0ea9ec-0710-46cd-8fc0-6e94d3c9a227.jpg?v=1571728855"},{"product_id":"polyrad-2-5-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 2.5 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 2.5 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy our Product Polyrad 2.5 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,8\/1kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 2.5 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e2.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e46 x 0.25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.93\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e5.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e6.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e8.21\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e20\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e64\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412510\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185756454975,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_c9297d38-efd9-4e35-a7e3-a4815ef08e0e.jpg?v=1571728855"},{"product_id":"polyrad-240-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 240 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 240 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy our Product Polyrad 240 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 240 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e240\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e1110 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e21.62\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e22.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e26.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.0817\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2030\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2234\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412470\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185757077567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_364893b2-fe51-46da-be53-1e1cbace1c5f.jpg?v=1571728855"},{"product_id":"polyrad-240-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 240 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 240 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our Product Polyrad 240 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 240 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e240\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e1110 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e21.62\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e23.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e27.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.0817\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2030\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2350\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412670\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185757143103,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_4f2ea4e8-3d44-41af-8919-e36341460dc2.jpg?v=1571728855"},{"product_id":"polyrad-25-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 25 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 25 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV\u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 25 CSA . Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 25 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e25\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e182 x 0.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e6.80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e7.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e9.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.795\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e205\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e238\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412390\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185757306943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_4861ae85-7446-47a5-b68e-91bb782aedbf.jpg?v=1571728856"},{"product_id":"polyrad-25-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 25 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 25 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our Product Polyrad 25 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 25 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e25\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e182 x 0.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e6.80\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e9.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e11.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.795\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e205\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e293\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412570\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185757339711,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_90f8902e-0133-4782-a565-ae00bcff749b.jpg?v=1571728856"},{"product_id":"polyrad-300-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 300 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 300 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 300 CSA , Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Buy our Product Polyrad 240 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e300\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e1406 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e24.33\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e24.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e28.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.0654\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2571\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2780\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412480\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185764319295,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Multi-Core_20and_20Pairs_20Sheathed_20300V_20500V-lg.jpg?v=1571728857"},{"product_id":"polyrad-300-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 300 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 300 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our Product Polyrad 300 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 300 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e300\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e1406 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e24.33\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e25.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e30.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.0654\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2571\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e2823\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412680\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185764450367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_8351533d-a9a9-4a24-a02b-acb738bbcd9c.jpg?v=1571728857"},{"product_id":"polyrad-35-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 35 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 35 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 35 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 35 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e259 x 0.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e8.12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e9.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e10.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.565\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e292\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e330\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412400\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185765826623,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_6155633e-2605-44a8-be08-c5cb642a6a5c.jpg?v=1571728857"},{"product_id":"polyrad-35-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 35 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 35 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our Product Polyrad 35 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 35 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e35\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e259 x 0.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e8.12\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e11.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e13.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.565\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e292\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e390\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412580\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185765924927,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_f4535c7f-9d7b-4c32-ba6a-22e096a66da4.jpg?v=1571728857"},{"product_id":"polyrad-4-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 4 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 4 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 4 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 4 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e56 x 0.30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e3.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e4.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e5.09\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e35\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e45\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412330\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185766678591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_8c6f5b0f-314f-410c-b3ac-f2dd457fbc10.jpg?v=1571728857"},{"product_id":"polyrad-4-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 4 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 4 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy our Product Polyrad 4 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,8\/1kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 4 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e4\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e56 x 0.30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e6.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e7.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e5.09\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e35\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e83\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412520\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185766776895,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_5afc9509-caa7-4a49-8931-74ecff2e06b2.jpg?v=1571728857"},{"product_id":"polyrad-400-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 400 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 400 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy our Product Polyrad 400 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 400 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e400\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e1850 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e27.91\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e28.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e32.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.0495\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3382\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3735\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412490\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185768841279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_da0e3d0b-4882-496f-abc8-937eb5b51f3d.jpg?v=1571728858"},{"product_id":"polyrad-400-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 400 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 400 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our Product Polyrad 400 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 400 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e400\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e1850 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e27.91\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e29.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e34.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.0495\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3382\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3734\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412690\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185768939583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_1136b7e9-2b52-4941-853d-76fcf5294bb2.jpg?v=1571728858"},{"product_id":"polyrad-50-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 50 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 50 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 50 CSA , Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 50 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e371 x 0.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e9.72\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e10.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e12.4\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.393\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e418\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e462\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412410\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185769332799,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_ed3c330c-558f-4dae-a18f-294b50822601.jpg?v=1571728859"},{"product_id":"polyrad-50-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 50 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 50 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our Product Polyrad 50 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 50 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e50\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e371 x 0.40\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e9.72\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e12.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e14.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.393\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e418\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e525\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412590\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185769431103,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_7e2e5ee7-2a84-40ff-ab2e-7be968f3017c.jpg?v=1571728859"},{"product_id":"polyrad-6-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 6 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 6 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 6 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 6 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e82 x 0.30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e3.07\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e0.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e4.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e5.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3.39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e53\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e63\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412340\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185769496639,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_f8c307c3-c45e-4650-b20c-2fd55005d468.jpg?v=1571728859"},{"product_id":"polyrad-6-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 6 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 6 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our Product Polyrad 6 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 6 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e6\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e82 x 0.30\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e3.07\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e6.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e7.8\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e3.39\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e53\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e104\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412530\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185769594943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_0852a101-94a3-477d-b411-5970b41f9fb7.jpg?v=1571728859"},{"product_id":"polyrad-70-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 70 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 70 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 70 CSA , Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 70 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e70\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e329 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e11.60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e12.5\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e14.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.277\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e596\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e658\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412420\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185770512447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_16435bf1-a07f-4231-8641-b4720d9964cd.jpg?v=1571728859"},{"product_id":"polyrad-70-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 70 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 70 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy our Product Polyrad 70 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 70 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e70\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e329 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e11.60\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e14.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e16.6\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.277\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e596\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e720\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412610\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185770545215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_ebd2b1ce-f7b5-44ab-a1fe-52063d60e01f.jpg?v=1571728859"},{"product_id":"polyrad-95-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv","title":"General Cable Polyrad® 95 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV","description":"\n    \n        \u003ctitle\u003ePolyrad 95 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \u003c\/title\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 95 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n        \u003cmeta name=\"Description\" content=\"Polyrad 95 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 0,6\/1kV \"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e95\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e437 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e13.52\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e1.1\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e13.9\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e16.3\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.210\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e795\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e860\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412430\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185772347455,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_4d1ca695-1255-49c6-9a56-943c01223a66.jpg?v=1571728860"},{"product_id":"polyrad-95-csa-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-1-8-3-kv","title":"General Cable Polyrad® 95 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV","description":"\n    \n        \u003ctitle\u003ePolyrad 95 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\u003c\/title\u003e\n        \u003cmeta name=\"Description\" content=\"Buy Our Product Polyrad 95 CSA LSHF Low-Smoke Halogen-Free Medium Wall Single Core Unsheathed EN Cable Reduced Dimensions 1,8\/3 kV\"\u003e\n        \u003cmeta name=\"Keywords\" content=\"Polyrad 95 CSA, Polyrad LSHF, Low-Smoke Halogen, Medium Wall Single Core Unsheathed EN Cable, Unsheathed EN Cable Reduced Dimensions 0,6\/1kV or 1,8\/3kV, , Low-Smoke Halogen Dimensions 0,6\/1kV or 1,8\/3kV, EN Cable, Unsheathed EN Cable, Polyrad, Medium Wall Single Core Unsheathed EN Cable\"\u003e\n    \n    \n        \u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e Flexible Class 5 stranded tinned copper per IEC 60228\u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulation: \u003c\/strong\u003e\u003cbr\u003e\n        • 90°C Low-Smoke, Halogen-Free irradiated Cross-linked Polyolefin\n        (EI 106 to EI 109) \u003cbr\u003e\n        • Black – unless otherwise specified \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e \u003cbr\u003e\n        • Manufacturer’s Name \u003cbr\u003e\n        • EN Reference \u003cbr\u003e\n        • Voltage Rating (U0) \u003cbr\u003e\n        • Conductor Size \u003cbr\u003e\n        • Insulation Code Designation per Annex A of EN 50264-3-1 \u003cbr\u003e\n        • Lot Number \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e\n        • Lighting circuits powered by accumulators \u003cbr\u003e\n        • Equipment control and monitoring circuits \u003cbr\u003e\n        • Auxiliary and electric heating circuits \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e \u003cbr\u003e\n        • EN 60684-2: No Fluorine \u003cbr\u003e\n        • EN 50305\/EN 60811-2-2: Resistant to Oil and Fuel \u003cbr\u003e\n        • EN 60811-2-1: Resistant to Mineral Oil \u003cbr\u003e\n        • EN 50305: Ozone-Resistant; No Toxicity \u003cbr\u003e\n        • EN 60811-1-4: Cold Bend (-40?C) \u003c\/p\u003e\n        \u003cp\u003e\u003cstrong\u003eOther Design Adherence: \u003c\/strong\u003e\u003cbr\u003e\n        • EN 60332-1-2 and EN 60332-3-25: Flame- \u0026amp; Fire-Retardant \u003cbr\u003e\n        • EN 50267-2-1 and EN 50267-2-2: Halogen-Free; Low Acidity and Corrosivity\n        of Evolved Gases \u003cbr\u003e\n        • EN 61034-2: Low-Smoke \u003cbr\u003e\n        • No SVHC Listed Chemicals under REACH \u003cbr\u003e\n        • RoHS Compliant\u003c\/p\u003e\n        \u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003cbr\u003e\n        \u003ctable\u003e\n            \u003ctbody\u003e\n                \u003ctr\u003e\n                    \u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecross sectional area(mm²)\u003c\/td\u003e\n                    \u003ctd\u003e95\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(construction n x mm)\u003c\/td\u003e\n                    \u003ctd\u003e437 x 0.50\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor(diameter mm)\u003c\/td\u003e\n                    \u003ctd\u003e13.52\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n                    \u003ctd\u003e2.2\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(min.mm)\u003c\/td\u003e\n                    \u003ctd\u003e16.0\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003ecable diameter(max.mm)\u003c\/td\u003e\n                    \u003ctd\u003e18.7\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003econductor resistance(max.ω\/km)\u003c\/td\u003e\n                    \u003ctd\u003e0.210\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e795\u003cbr\u003e\n                    \u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n                    \u003ctd\u003e935\u003c\/td\u003e\n                \u003c\/tr\u003e\n                \u003ctr\u003e\n                    \u003ctd\u003e\n                    \u003cdiv\u003epart number\u003c\/div\u003e\n                    \u003c\/td\u003e\n                    \u003ctd\u003e412620\u003c\/td\u003e\n                \u003c\/tr\u003e\n            \u003c\/tbody\u003e\n        \u003c\/table\u003e\n        \u003c\/div\u003e\n    \n","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7185772445759,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Polyrad_20Medium_20Wall_200_6_201_20kV_20or_201_8_203_20kV-lg_f1094a0e-db60-4799-b81f-18b486830e3f.jpg?v=1571728860"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/general-cable-polyrad%c2%ae-lshf-low-smoke-halogen-free-medium-wall-single-core-unsheathed-en-cable-reduced-dimensions-0-6-1kv-or-1-8-3kv.oembed?page=3","provider":"NassauElectrical","version":"1.0","type":"link"}