{"title":"General Cable NextGen® Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"","products":[{"product_id":"nextgen-12-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 12 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 12 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 12 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"12 Fiber ,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0124H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152374153279,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_dffdf500-a04a-4f95-a061-d654ff6a13f9.jpg?v=1571727465"},{"product_id":"nextgen-120-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 120 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 120 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 120 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"120 Fiber ,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40°F) to +75°C (+167°F) \u003cbr\u003e      Installation -30°C (-22°F) to +60°C (+140°F) \u003cbr\u003e      Operating -40°C (-40°F) to +70°C (+158°F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e19.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e201\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e299\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX1204H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152374906943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_e04213e0-0d88-422c-9fe6-deeba4cb7e5a.jpg?v=1571727485"},{"product_id":"nextgen-144-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 144 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 144 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 144 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"144 Fiber ,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40°F) to +75°C (+167°F) \u003cbr\u003e      Installation -30°C (-22°F) to +60°C (+140°F) \u003cbr\u003e      Operating -40°C (-40°F) to +70°C (+158°F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.84\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e21.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e234\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e348\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX1444H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152375824447,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_c89a9c20-aee3-42f7-b973-cbcf0880a705.jpg?v=1571727485"},{"product_id":"nextgen-18-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 18 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 18 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 18 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"18 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0184H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152376250431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_eb4af0c8-9189-48f4-b708-3054e816f373.jpg?v=1571727485"},{"product_id":"nextgen-192-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 192 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 192 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 192 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"192 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40°F) to +75°C (+167°F) \u003cbr\u003e      Installation -30°C (-22°F) to +60°C (+140°F) \u003cbr\u003e      Operating -40°C (-40°F) to +70°C (+158°F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e21.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e342\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e 600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX1924H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152376807487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_ecefceda-455c-4834-8245-c8be9d261c1d.jpg?v=1571727485"},{"product_id":"nextgen-2-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 2 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 2 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 2 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"2 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber count\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003exx0023h1f-dwb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152377069631,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_3d1bdefa-49e5-4c10-90af-42e476a6c580.jpg?v=1571727486"},{"product_id":"nextgen-216-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 216 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 216 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 216 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"216 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40°F) to +75°C (+167°F) \u003cbr\u003e      Installation -30°C (-22°F) to +60°C (+140°F) \u003cbr\u003e      Operating -40°C (-40°F) to +70°C (+158°F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.85\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e21.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e342\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX2164H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152377561151,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_b79236a7-4266-414b-9824-74dfa350a79e.jpg?v=1571727486"},{"product_id":"nextgen-24-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 24 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 24 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 24 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"24 Fiber ,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0244H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152377921599,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_d2eada80-3d08-4ce8-8b5a-b31d046f33e2.jpg?v=1571727486"},{"product_id":"nextgen-240-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 240 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 240 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 240 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"240 Fiber ,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40°F) to +75°C (+167°F) \u003cbr\u003e      Installation -30°C (-22°F) to +60°C (+140°F) \u003cbr\u003e      Operating -40°C (-40°F) to +70°C (+158°F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e22.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX2404H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152378773567,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_61acdfc3-70e8-4e07-a3a1-1f9b53cecec6.jpg?v=1571727487"},{"product_id":"nextgen-264-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 264 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 264 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 264 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"264 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40°F) to +75°C (+167°F) \u003cbr\u003e      Installation -30°C (-22°F) to +60°C (+140°F) \u003cbr\u003e      Operating -40°C (-40°F) to +70°C (+158°F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e264\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e 0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e22.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e259\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e385\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX2644H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152379297855,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_8791d8fd-c549-4487-afd1-66f7b9429e39.jpg?v=1571727487"},{"product_id":"nextgen-288-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 288 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 288 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 288 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"288 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40°F) to +75°C (+167°F) \u003cbr\u003e      Installation -30°C (-22°F) to +60°C (+140°F) \u003cbr\u003e      Operating -40°C (-40°F) to +70°C (+158°F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e288\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e23.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e282\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX2884H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152379396159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_657a8dbf-7f88-4386-b56b-9d58a9a02d18.jpg?v=1571727487"},{"product_id":"nextgen-312-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 312 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 312 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 312 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"312 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40°F) to +75°C (+167°F) \u003cbr\u003e      Installation -30°C (-22°F) to +60°C (+140°F) \u003cbr\u003e      Operating -40°C (-40°F) to +70°C (+158°F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e312\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e25.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e461\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX3124H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152379592767,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_eb1f52df-f2cb-459c-b04c-6a127e9f844f.jpg?v=1571727487"},{"product_id":"nextgen-36-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 36 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 36 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 36 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"36 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e36\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0364H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152379953215,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_783ab630-24ba-46d0-9fcc-8b0912b740f1.jpg?v=1571727487"},{"product_id":"nextgen-4-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 4 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 4 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 4 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"4 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0044H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152380674111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_2c59a775-adb7-4b41-8f93-dc516893766c.jpg?v=1571727487"},{"product_id":"nextgen-48-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 48 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 48 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 48 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"48 Fiber ,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40°F) to +75°C (+167°F) \u003cbr\u003e      Installation -30°C (-22°F) to +60°C (+140°F) \u003cbr\u003e      Operating -40°C (-40°F) to +70°C (+158°F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e48\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0484H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152382443583,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_1927f52d-dae9-4d67-8054-5f0c4a5019a5.jpg?v=1571727488"},{"product_id":"nextgen-6-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 6 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 6 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 6 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"6 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0064H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152384442431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_55e5d2ac-fd83-4ae0-8de9-7c2df78c6bbc.jpg?v=1571727489"},{"product_id":"nextgen-60-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 60 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 60 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 60 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"60 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40°F) to +75°C (+167°F) \u003cbr\u003e      Installation -30°C (-22°F) to +60°C (+140°F) \u003cbr\u003e      Operating -40°C (-40°F) to +70°C (+158°F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e60\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0604H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152385425471,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_64d97159-09a0-473a-afe5-3b8385217a05.jpg?v=1571727489"},{"product_id":"nextgen-72-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 72 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 72 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 72 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\" 72 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40°F) to +75°C (+167°F) \u003cbr\u003e      Installation -30°C (-22°F) to +60°C (+140°F) \u003cbr\u003e      Operating -40°C (-40°F) to +70°C (+158°F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e143\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e213\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0724H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152386506815,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_7e419754-41db-4f34-b7ea-d927f5a48b31.jpg?v=1571727490"},{"product_id":"nextgen-8-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 8 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 8 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 8 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"8 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0084H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152388079679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_0124e77c-5687-4e3f-971d-f83667192f23.jpg?v=1571727490"},{"product_id":"nextgen-96-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® 96 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"NextGen 96 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\u003cmeta name=\"Description\" content=\"Buy our products NextGen 96 Fiber Count Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"96 Fiber,NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,  Fiber Cable.\"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40°C (-40°F) to +75°C (+167°F) \u003cbr\u003e      Installation -30°C (-22°F) to +60°C (+140°F) \u003cbr\u003e      Operating -40°C (-40°F) to +70°C (+158°F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specifications:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003efiber coun\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cdiv\u003eno. of loose tubes\u003c\/div\u003e\n\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of fillers\u003c\/td\u003e\n\u003ctd\u003e0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(in)\u003c\/td\u003e\n\u003ctd\u003e0.69\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e17.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(lbs\/1000')\u003c\/td\u003e\n\u003ctd\u003e169\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e251\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in lbs)\u003c\/td\u003e\n\u003ctd\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (installation in n)\u003c\/td\u003e\n\u003ctd\u003e2670\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in lbs )\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emaximum tensile load (in-service in n)\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003eXX0964H1F-DWB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152388898879,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_34d6a952-5ac7-4aa2-a063-295b012678c8.jpg?v=1571727490"},{"product_id":"nextgen-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable","title":"General Cable NextGen® Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable","description":"\u003cdiv class=\"clr\"\u003e\u003c\/div\u003e\n\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cmeta name=\"Description\" content=\"Buy our products NextGen Loose Tube Dual Jacket Armored Outside Plant Fiber Optic Cable\"\u003e\u003cmeta name=\"Keywords\" content=\"NextGen, Loose Tube, Dual Jacket, Dual Jacket Armored, Outside Plant Fiber, Fiber Optic Cable,\n        Fiber Cable.\n        \"\u003e\n\u003cp\u003e\u003cstrong\u003eFiber:\u003c\/strong\u003e \u003cbr\u003e • 2–312 fibers \u003cbr\u003e • Loose tube gel-filled \u003cbr\u003e • Color-coding per TIA\/EIA 598 B \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCentral Strength Member: \u003c\/strong\u003eEpoxy\/glass rod \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInner Jacket:\u003c\/strong\u003e Black UV- and moisture-resistant polyethylene (PE) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eArmor:\u003c\/strong\u003e Corrugated coated steel tape \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOuter Jacket: \u003c\/strong\u003e\u003cbr\u003e • Black UV- and moisture-resistant polyethylene (PE) \u003cbr\u003e • Sequential footage markings*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e \u003cbr\u003e • Loose tube gel-filled construction for superior fiber protection \u003cbr\u003e • UV- and moisture-resistant design \u003cbr\u003e • Rodent-resistant construction \u003cbr\u003e • Dry Water Block cable core for ease of handling \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePerformance:\u003c\/strong\u003e \u003cbr\u003e • Temperature: \u003cbr\u003e      Storage -40?C (-40?F) to +75?C (+167?F) \u003cbr\u003e      Installation -30?C (-22?F) to +60?C (+140?F) \u003cbr\u003e      Operating -40?C (-40?F) to +70?C (+158?F) \u003cbr\u003e • Minimum Bend Radius: \u003cbr\u003e      20 X OD—Installation \u003cbr\u003e      10 X OD—In-Service \u003cbr\u003e • Maximum Crush Resistance: \u003cbr\u003e      Short - 125 lbs\/in (220 N\/cm) \u003cbr\u003e      Long - 63 lbs\/in (110 N\/cm) \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e \u003cbr\u003e • Interbuilding voice or data communication backbones \u003cbr\u003e • Installed in ducts, underground conduits, aerial\/lashed or direct buried \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e \u003cbr\u003e • Tested in accordance with EIA\/TIA-455 FOTPs \u003cbr\u003e • ICEA S-87-640 \u003cbr\u003e • Rural Utilities Service (RUS) 7 CFR 1755.900 (REA PE-90) \u003cbr\u003e • GR-20 \u003cbr\u003e • RoHS Compliant Directive 2011\/65\/EU \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptions:\u003c\/strong\u003e \u003cbr\u003e • Gel-free tube versions also available, use “-DT” suffix (XX0124M1F-DT)** \u003cbr\u003e • Alternate 6-fiber per tube available upon request\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003efiber count\u003c\/td\u003e\n\u003ctd\u003eno. of loose tubes\u003c\/td\u003e\n\u003ctd\u003eMaximum Tensile Load\u003c\/td\u003e\n\u003ctd\u003eGeneral Cable And Nextgen \u003cbr\u003eBrand Part Number\u003c\/td\u003e\n\u003ctd\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-2-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e2\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0023h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-2-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-4-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0044h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-4-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-6-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0064h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-6-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-8-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e8\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0084h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-8-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-12-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e12\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0124h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-12-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-18-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e18\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0184h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-18-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-24-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e24\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0244h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-24-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-36-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e36\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0364h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-36-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-48-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e48\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0484h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-48-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-60-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e60\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0604h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-60-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-72-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e72\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0724h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-72-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-96-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e96\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx0964h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-96-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-120-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e120\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx1204h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-120-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-144-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e144\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx1444h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-144-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-192-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e192\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx1924h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-192-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-216-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e216\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e18\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx2164h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-216-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-240-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e240\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx2404h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-240-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-264-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e264\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e22\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx2644h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-264-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-288-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e288\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e24\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx2884h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-288-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-312-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003e312\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e26\u003c\/td\u003e\n\u003ctd\u003e800\u003c\/td\u003e\n\u003ctd\u003exx3124h1f-dwb\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/fiber-optic-cable\/outside-plant-cables\/nextgen-312-fiber-count-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7152396107839,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_1_4ab528c7-a4d5-4f6e-aaf3-2b128500ccd1.jpg?v=1571727493"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/general-cable-nextgen%c2%ae-loose-tube-dual-jacket-armored-outside-plant-fiber-optic-cable.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}