{"title":"General Cable GenFree® XLPE Type TC-LS-ER1 Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"","products":[{"product_id":"genfree-xlpe-type-tc-ls-er1-10-12-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 10\/12 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 10\/12 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 10\/12 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394920* Click for a free quote.10\/12 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"10\/12 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.910\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e23.11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e404\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e601\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e654\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e973\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394920*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130173997119,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_6914bb50-cf7c-4f35-8248-291f5d0d3d99.jpg?v=1571726370"},{"product_id":"genfree-xlpe-type-tc-ls-er1-10-2-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 10\/2 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 10\/2 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 10\/2 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394860* Click for a free quote.10\/2 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"10\/2 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.460\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e11.68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394860*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130174128191,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_40e939f2-afe2-4dcf-b95e-6801adca3861.jpg?v=1571726370"},{"product_id":"genfree-xlpe-type-tc-ls-er1-10-3-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 10\/3 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 10\/3 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V ULGenFree\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 10\/3 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V ULGenFree-394870* Click for a free quote.10\/3 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"10\/3 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.490\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394870*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130174980159,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_f47fb533-28e1-4809-81fc-4803e4b99981.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-10-4-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 10\/4 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 10\/4 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 10\/4 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394880* Click for a free quote.10\/4 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"10\/4 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.565\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e14.35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e136\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e202\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e237\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e353\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394880*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130175340607,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_4c036739-24b3-4c9c-a588-874f42e9bbbc.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-10-5-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 10\/5 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 10\/5 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 10\/5 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394890* Click for a free quote.10\/5 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"10\/5 Gauge  GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e15.75\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e253\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e287\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e427\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394890*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130175406143,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_7bf60ea6-3dfe-42f9-970f-6d0270147842.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-10-7-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 10\/7 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 10\/7 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 10\/7 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394900* Click for a free quote.10\/7 Gauge ,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"10\/7 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.675\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e17.15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e237\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e353\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e384\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e571\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394900*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130175471679,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_b8c0a5ca-a34a-434b-a236-caf5422c8136.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-10-9-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 10\/9 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 10\/9 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 10\/9 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394910* Click for a free quote.10\/9 Gauge ,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"10\/9 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.765\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e19.43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e298\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e443\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e467\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e695\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394910*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130176520255,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_c6021f19-c4b5-4a97-af71-c135b99f7cc4.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-12-12-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 12\/12 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 12\/12 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 12\/12 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394810* Click for a free quote.12\/12 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"12\/12 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.770\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e19.56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e249\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e371\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e431\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e641\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394810*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130176618559,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_c0bbe1ac-93c3-4906-9a87-225802cd6c26.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-12-19-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 12\/19 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 12\/19 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 12\/19 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394820* Click for a free quote.12\/19 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"12\/19 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.945\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e24.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e393\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e585\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e691\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1028\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394820*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130176684095,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_055523ab-cc9c-4167-946c-3625561122d0.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-12-2-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 12\/2 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 12\/2 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 12\/2 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394750* Click for a free quote.12\/2 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"12\/2 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.415\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e10.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394750*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130176782399,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_8735f3df-5a37-474e-a32a-08c2e112d926.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-12-25-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 12\/25 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 12\/25 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 12\/25 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394830* Click for a free quote.12\/25 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"12\/25 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e27.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e517\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e769\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e857\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1275\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394830*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130176847935,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_051ee03c-d132-4361-819a-753a079c85ea.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-12-3-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 12\/3 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 12\/3 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 12\/3 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394760* Click for a free quote.12\/3 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"12\/3 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.440\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e11.18\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e189\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394760*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130177568831,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_cf51d906-8d78-4c43-8150-90602b573c9b.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-12-30-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 12\/30 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 12\/30 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 12\/30 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394840* Click for a free quote.12\/30 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"12\/30 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.155\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e29.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e620\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e923\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1496\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394840*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130178650175,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_bd67e152-2f0d-4f6f-8433-f1381a3443c4.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-12-37-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 12\/37 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 12\/37 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 12\/37 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394850* Click for a free quote.12\/37 Gauge ,7W strand \"\u003e\u003cmeta name=\"Keywords\" content=\"12\/37 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e31.62\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e764\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1137\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e1243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394850*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130178715711,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_54803c98-37d4-417d-b0b8-89a820c253fb.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-12-4-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 12\/4 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 12\/4 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 12\/4 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394770* Click for a free quote.12\/4 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"12\/4 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.480\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e12.19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e238\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394770*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130178814015,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_ac10329a-6881-473b-9c66-7f27507e3df9.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-12-5-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 12\/5 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 12\/5 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 12\/5 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394780* Click for a free quote.12\/5 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"12\/5 AWG GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.525\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e13.34\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e162\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e194\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e289\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394780*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130178879551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_b4a71d43-5284-4d2d-93d2-54a0bf8f0685.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-12-7-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 12\/7 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 12\/7 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  GenFree XLPE Type TC-LS-ER1 12\/7 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394790* Click for a free quote.12\/7 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"12\/7 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e15.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e151\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e271\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394790*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130178945087,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_db8063a1-8989-4c03-a93d-6d96590efe19.jpg?v=1571726371"},{"product_id":"genfree-xlpe-type-tc-ls-er1-12-9-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 12\/9 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 12\/9 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 12\/9 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394800* Click for a free quote.12\/9 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"12\/9 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e17.78\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e193\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e287\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e506\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394800*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130179797055,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_74f0fd0c-9a7b-45d7-b7fc-dee7909da96f.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-14-12-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 14\/12 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 14\/12 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 14\/12 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394700* Click for a free quote.14\/12 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"14\/12 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e17.91\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e238\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e452\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394700*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130179862591,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_8bd8c708-dafe-4675-9456-7a65020c64f6.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-14-19-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 14\/19 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 14\/19 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 14\/19 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394710* Click for a free quote.14\/19 Gauge ,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"14\/19 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.820\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e20.83\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e252\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e471\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e701\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394710*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130179928127,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_27ccf102-e54b-4ba0-9433-d1d63742e61b.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-14-2-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 14\/2 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 14\/2 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  GenFree XLPE Type TC-LS-ER1 14\/2 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394640* Click for a free quote.14\/2 Gauge 7W stranding\"\u003e\u003cmeta name=\"Keywords\" content=\"Type TC-LS-ER1 14\/2 Gauge,GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.375\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e9.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e43\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e74\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394640*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130180026431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_52f8c25e-29f8-496d-991f-bba3243adedc.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-14-25-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 14\/25 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 14\/25 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 14\/25 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394720* Click for a free quote.14\/25 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"14\/25 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e25.53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e484\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e627\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e933\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394720*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130180091967,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_385fcfce-3a52-4538-84ce-c64783ab3def.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-14-3-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 14\/3 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 14\/3 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  GenFree XLPE Type TC-LS-ER1 14\/3 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394650* Click for a free quote.14\/3 Gauge 7W stranding\"\u003e\u003cmeta name=\"Keywords\" content=\"Type TC-LS-ER1 14\/3 Gauge,GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.395\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e10.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e42\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394650*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130181009471,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_c56382df-031e-436d-99ce-ee93864f3a16.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-14-30-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 14\/30 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 14\/30 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 14\/30 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394730* Click for a free quote.14\/30 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"14\/30 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e26.29\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e389\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e579\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394730*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130181075007,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_bb773f4f-821a-4ecf-906c-7eb24fc27a99.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-14-37-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 14\/37 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 14\/37 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 14\/37 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394740* Click for a free quote.14\/37 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"14\/37 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e2.03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e1.115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e28.32\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e468\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e696\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e878\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1307\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394740*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130181140543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_b26bde82-ff60-4176-a5fc-3540721c6c7b.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-14-4-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 14\/4 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 14\/4 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  GenFree XLPE Type TC-LS-ER1 14\/4 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394660* Click for a free quote.14\/4 Gauge 7W stranding\"\u003e\u003cmeta name=\"Keywords\" content=\"Type TC-LS-ER1 14\/4 Gauge, GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e10.92\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e82\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394660*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130181206079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_024c4040-8460-4379-9e4f-b1f45c49e295.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-14-5-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 14\/5 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 14\/5 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of  GenFree XLPE Type TC-LS-ER1 14\/5 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394670* Click for a free quote.14\/3 Gauge 7W stranding\"\u003e\u003cmeta name=\"Keywords\" content=\" Type TC-LS-ER1 14\/5 Gauge,GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e11.94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e68\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e211\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394670*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130181533759,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_5f4328b3-34b1-44f9-a58c-617146c9e5a3.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-14-7-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 14\/7 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 14\/7 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 14\/7 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394680* Click for a free quote.14\/7 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"14\/7 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e12.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e94\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e140\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e176\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e262\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394680*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130182516799,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_91892ba3-3265-4451-af47-2fa75cde73d3.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-14-9-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 14\/9 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 14\/9 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 14\/9 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394690* Click for a free quote.14\/9 Gauge,7W strand\"\u003e\u003cmeta name=\"Keywords\" content=\"14\/9 Gauge GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire\"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.625\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e15.88\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e362\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394690*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130182582335,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_b759f883-aa85-4a23-8167-b09baf8b4880.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-16-2-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 16\/2 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 16\/2 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 16\/2 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394960* Click for a free quote.16\/2 Gauge , 7W stranding\"\u003e\u003cmeta name=\"Keywords\" content=\"Type TC-LS-ER1 16\/2 Gauge,GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire  \"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e8.13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e28\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394960*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130182615103,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_2bfb34d4-0768-4c39-8034-76019d882adc.jpg?v=1571726372"},{"product_id":"genfree-xlpe-type-tc-ls-er1-16-3-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 16\/3 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"GenFree XLPE Type TC-LS-ER1 16\/3 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL\u003cmeta name=\"Description\" content=\"Browse our selection of GenFree XLPE Type TC-LS-ER1 16\/3 Gauge Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL-394630* Click for a free quote.16\/3 Gauge , 7W stranding\"\u003e\u003cmeta name=\"Keywords\" content=\" Type TC-LS-ER1 16\/3 Gauge,GenFree cable , GenFree wire, XLPE, XLPE type cable, XLPE cable wire, Type TC-LS-ER1 cable, Type TC-LS-ER1 wire, Type TC-LS-ER1 cable price, Type TC-LS-ER1 cable quote, tray cable, Type TC-LS-ER1, Overall Shielded cable, Overall Shielded wire, Shielded cable, Shielded cable price, Shielded cable quote, Control cable, 600V UL cable, 600V UL wire, 600V UL price, LSZH Control cable, LSZH Control cable price, LSZH Control cable quote, low smoke cable, low smoke wire  \"\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90?C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30?C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. size(awg)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eno. of cond.\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econd. strand\u003c\/td\u003e\n\u003ctd\u003e7W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.025\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. insulation thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e0.64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(inches)\u003c\/td\u003e\n\u003ctd\u003e0.045\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eminimum avg. jacket thickness(mm)\u003c\/td\u003e\n\u003ctd\u003e1.14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominal cable o.d.(inches)\u003c\/td\u003e\n\u003ctd\u003e0.335\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enominalcable o.d.(mm)\u003c\/td\u003e\n\u003ctd\u003e8.51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e27\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecopper weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(lbs\/1000 ft)\u003c\/td\u003e\n\u003ctd\u003e66\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003enet weight(kg\/km)\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecatalog number\u003c\/td\u003e\n\u003ctd\u003e394630*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7130182713407,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_8a945d43-6ddd-4dc9-b59b-d84bd4a7249c.jpg?v=1571726372"},{"product_id":"general-cable-genfree®-xlpe-type-tc-ls-er1-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul","title":"General Cable GenFree® XLPE Type TC-LS-ER1 Overall Shielded E-2 Color Code LSZH Control Shielded 600V UL","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • 16 AWG thru 10 AWG stranded tinned copper per ASTM B33\u003cbr\u003e • Class B stranding per ASTM B8\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • Lead-free, flame-retardant, low-smoke Cross-linked Polyethylene (XLPE)\u003cbr\u003e • Color-coded per ICEA Method 1, Table E-2 (does not include white or green)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eShield:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eOverall shielded multi-conductor cable:\u003c\/strong\u003e Overall shield is Flexfoil® aluminum\/polymer in contact with stranded tinned copper drain wire\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eJacket: \u003c\/strong\u003eLead-free, flame-retardant, sunlight-resistant, Low-Smoke, Zero-Halogen Polyolefin (LSZH)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e\u003cbr\u003e • In free air, raceway, aerial and direct burial\u003cbr\u003e • In wet or dry locations\u003cbr\u003e • Permitted for use in Class I, Division 2 industrial hazardous locations per NEC\u003cbr\u003e • Permitted for Exposed Run (ER) use in accordance with the NEC for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003cbr\u003e • Rated at 90˚C wet or dry\u003cbr\u003e • Ripcord applied to all cables with jacket thickness of 60 mils or less\u003cbr\u003e • Excellent physical and electrical properties\u003cbr\u003e • Excellent moisture resistance\u003cbr\u003e • Excellent resistance to compression and impact\u003cbr\u003e • Chemical-resistant\u003cbr\u003e • Low coefficient of friction for easy pulling\u003cbr\u003e • Sunlight- and weather-resistant\u003cbr\u003e • Meets cold bend test at -30˚C\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket is environmentally safe\u003cbr\u003e • Low-Smoke, Zero-Halogen jacket reduces the amount of toxic and corrosive gases emitted during combustion, providing a safer environment for personnel and equipment during the hazards of fire\u003cbr\u003e • Meets the crush and impact requirements of Type MC cable for 3 or more conductors\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliances:\u003c\/strong\u003e\u003cbr\u003e \u003cstrong\u003eIndustry Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 44 Type XHHW-2\u003cbr\u003e • UL 1277 Type TC-LS-ER, UL File # E57179\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • ICEA S-73-532\/NEMA WC57\u003cbr\u003e • ICEA T-33-655\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlame Test Compliances:\u003c\/strong\u003e\u003cbr\u003e • UL 1581\/UL 2556\u003cbr\u003e • UL 1685 Vertical Flame Test\u003cbr\u003e • IEEE 1202\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Compliances:\u003c\/strong\u003e\u003cbr\u003e • EPA 40 CFR, Part 261 for leachable lead content per TCLP\u003cbr\u003e • OSHA Acceptable\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging:\u003c\/strong\u003e Material cut to length and shipped on non-returnable wood reels\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003econd. Size (AWG\/kcmil)\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eNo. of cond.\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eNet weight\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eGeneral cable part number\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd style=\"color: #ffffff;\"\u003eLbs\/1000Ft\u003c\/td\u003e\n\u003ctd style=\"color: #ffffff;\"\u003eKg\/Km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e77\u003c\/td\u003e\n\u003ctd\u003e394960*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-16-2-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e66\u003c\/td\u003e\n\u003ctd\u003e98\u003c\/td\u003e\n\u003ctd\u003e394630*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-16-3-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e14 AWG conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e74\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003ctd\u003e394640*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-14-2-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003ctd\u003e141\u003c\/td\u003e\n\u003ctd\u003e394650*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-14-3-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e118\u003c\/td\u003e\n\u003ctd\u003e176\u003c\/td\u003e\n\u003ctd\u003e394660*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-14-4-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e211\u003c\/td\u003e\n\u003ctd\u003e394670*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-14-5-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e176\u003c\/td\u003e\n\u003ctd\u003e262\u003c\/td\u003e\n\u003ctd\u003e394680*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-14-7-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e243\u003c\/td\u003e\n\u003ctd\u003e362\u003c\/td\u003e\n\u003ctd\u003e394690*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-14-9-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e304\u003c\/td\u003e\n\u003ctd\u003e452\u003c\/td\u003e\n\u003ctd\u003e394700*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-14-12-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-u\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e471\u003c\/td\u003e\n\u003ctd\u003e701\u003c\/td\u003e\n\u003ctd\u003e394710*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-14-19-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-u\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e627\u003c\/td\u003e\n\u003ctd\u003e933\u003c\/td\u003e\n\u003ctd\u003e394720*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-14-25-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-u\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e750\u003c\/td\u003e\n\u003ctd\u003e1116\u003c\/td\u003e\n\u003ctd\u003e394730*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-14-30-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-u\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e14\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e878\u003c\/td\u003e\n\u003ctd\u003e1307\u003c\/td\u003e\n\u003ctd\u003e394740*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-14-37-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-u\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e12 AWG conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e97\u003c\/td\u003e\n\u003ctd\u003e144\u003c\/td\u003e\n\u003ctd\u003e394750*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-12-2-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e127\u003c\/td\u003e\n\u003ctd\u003e189\u003c\/td\u003e\n\u003ctd\u003e394760*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-12-3-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e160\u003c\/td\u003e\n\u003ctd\u003e238\u003c\/td\u003e\n\u003ctd\u003e394770*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-12-4-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e194\u003c\/td\u003e\n\u003ctd\u003e289\u003c\/td\u003e\n\u003ctd\u003e394780*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-12-5-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e271\u003c\/td\u003e\n\u003ctd\u003e403\u003c\/td\u003e\n\u003ctd\u003e394790*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-12-7-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e340\u003c\/td\u003e\n\u003ctd\u003e506\u003c\/td\u003e\n\u003ctd\u003e394800*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-12-9-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e431\u003c\/td\u003e\n\u003ctd\u003e641\u003c\/td\u003e\n\u003ctd\u003e394810*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-12-12-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-u\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e19\u003c\/td\u003e\n\u003ctd\u003e691\u003c\/td\u003e\n\u003ctd\u003e1028\u003c\/td\u003e\n\u003ctd\u003e394820*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-12-19-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-u\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003ctd\u003e857\u003c\/td\u003e\n\u003ctd\u003e1275\u003c\/td\u003e\n\u003ctd\u003e394830*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-12-25-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-u\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e30\u003c\/td\u003e\n\u003ctd\u003e1005\u003c\/td\u003e\n\u003ctd\u003e1496\u003c\/td\u003e\n\u003ctd\u003e394840*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-12-30-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-u\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e37\u003c\/td\u003e\n\u003ctd\u003e1243\u003c\/td\u003e\n\u003ctd\u003e1850\u003c\/td\u003e\n\u003ctd\u003e394850*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-12-37-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-u\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e10 AWG conductors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e131\u003c\/td\u003e\n\u003ctd\u003e195\u003c\/td\u003e\n\u003ctd\u003e394860*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-10-2-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e175\u003c\/td\u003e\n\u003ctd\u003e260\u003c\/td\u003e\n\u003ctd\u003e394870*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-10-3-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e237\u003c\/td\u003e\n\u003ctd\u003e353\u003c\/td\u003e\n\u003ctd\u003e394880*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-10-4-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e287\u003c\/td\u003e\n\u003ctd\u003e427\u003c\/td\u003e\n\u003ctd\u003e394890*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-10-5-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e384\u003c\/td\u003e\n\u003ctd\u003e571\u003c\/td\u003e\n\u003ctd\u003e394900*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-10-7-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e467\u003c\/td\u003e\n\u003ctd\u003e695\u003c\/td\u003e\n\u003ctd\u003e394910*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-10-9-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003ctd\u003e654\u003c\/td\u003e\n\u003ctd\u003e973\u003c\/td\u003e\n\u003ctd\u003e394920*\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/instrumentation-cable-and-pltc\/600v-multi-conductor-control-and-power-cables\/type-tc-er1\/genfree-xlpe-type-tc-ls-er1-10-12-gauge-overall-shielded-e-2-color-code-lszh-control-shielded-600v-u\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"General Cable","offers":[{"title":"Default Title","offer_id":7414236938303,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/10_8f98e995-7a02-43e4-b057-fe41c2d0c9d5.jpg?v=1571729446"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/general-cable-genfree%c2%ae-xlpe-type-tc-ls-er1-overall-shielded-e-2-color-code-lszh-control-shielded-600v-ul.oembed","provider":"NassauElectrical","version":"1.0","type":"link"}