{"title":"General Cable GenFire® Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"","products":[{"product_id":"general-cable-genfire®-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\"\u003ecross-sectional area\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eweight\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003egeneral cable part number\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd style=\"color: #ffffff;\"\u003emm²\u003c\/td\u003e\n\u003ctd style=\"color: #ffffff;\"\u003ecopper kg\/km\u003c\/td\u003e\n\u003ctd style=\"color: #ffffff;\"\u003ecable kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-2-5-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e2.5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-2-5-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e7536107\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-2-5-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-4-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-4-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-\"\u003e7536108\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-4-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-6-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-6-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-\"\u003e7536109\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-6-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-10-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-10-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e7536110\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-10-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-16-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-16-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e7536111\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-16-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-25-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e25\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-25-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e7536112\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-25-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-35-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e35\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e292\u003c\/td\u003e\n\u003ctd\u003e425\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-35-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e7536113\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-35-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-50-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e50\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e418\u003c\/td\u003e\n\u003ctd\u003e570\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-50-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e7536114\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-50-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-70-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e70\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e596\u003c\/td\u003e\n\u003ctd\u003e765\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-70-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e7536115\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-70-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-95-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e95\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e795\u003c\/td\u003e\n\u003ctd\u003e970\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-95-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003e7536116\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-95-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-120-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e120\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1003\u003c\/td\u003e\n\u003ctd\u003e1225\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-120-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e7536117\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-120-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-150-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e150\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1245\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-150-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e7536118\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-150-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-185-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e185\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1556\u003c\/td\u003e\n\u003ctd\u003e1795\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-185-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e7536119\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-185-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-240-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e240\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2030\u003c\/td\u003e\n\u003ctd\u003e2365\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-240-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e7536120\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-240-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-300-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e300\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2571\u003c\/td\u003e\n\u003ctd\u003e2930\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-300-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e7536121\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-300-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-400-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e400\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3382\u003c\/td\u003e\n\u003ctd\u003e3915\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-400-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003e7536122\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-rail-400-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249824186431,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_2131e64c-cd07-405d-ae70-759256394f65.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-2-5-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 2.5 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e2.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e7.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e8.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e8.21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250697191487,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_6e85e51a-5acb-4d15-9661-a50375cb8e26.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-4-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 4 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e2.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e8.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e9.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e5.09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e96\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250698829887,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_092e34f5-172c-4737-ad27-394fbd95d846.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-6-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 6 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e3.10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e10.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e3.39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e125\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536109\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250699812927,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_a44ed015-4336-4fab-8829-853f18f0fbbb.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-10-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 10 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e4.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e9.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e11.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e1.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e170\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250701189183,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_0506ae50-0b3c-4a77-9b71-46271e3c7e29.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-16-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 16 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e4.90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e12.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e1.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250703450175,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_3f564395-b60b-41d1-9b12-bbd048eb46f6.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-25-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 25 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e6.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e11.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e13.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.795\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250745524287,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_55aa626b-f30a-4082-b31d-910a67f73334.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-35-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 35 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e7.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e13.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.565\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e292\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250756927551,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_fabd384b-b8f8-4e90-bb44-7027d362b080.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-50-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 50 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e9.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e14.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e16.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.393\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e418\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e570\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250760040511,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_40b049b2-d1eb-4a59-a8cc-59c27ea4e6a3.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-70-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 70 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e16.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e18.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e596\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e765\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250763612223,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_e7daed2a-9a2c-40fb-807e-ee2081cc1911.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-95-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 95 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e12.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e17.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e20.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e795\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e970\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250770264127,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_873180c2-8607-4613-b165-b100fb7b4e1f.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-120-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 120 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003ezConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e14.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e19.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e22.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250774786111,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_80e5002a-9956-4a12-9bba-66f22c37965e.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-150-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 150 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e20.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e24.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250830032959,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_cdfac946-2904-45a2-ada4-92d836add2e5.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-185-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 185 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e17.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e22.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e26.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1556\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1795\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536119\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250834882623,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_a59760af-6019-494c-a770-53d9f17f839f.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-240-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 240 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e20.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e25.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e29.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.0817\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2365\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250840256575,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_a0d88b84-514a-4c2f-842c-7a3912f441d2.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-300-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 300 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e22.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e27.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e32.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.0654\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2571\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2930\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250844811327,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_263e2b67-4d81-4f94-ba17-04a8975f2281.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-rail-400-csa-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv","title":"General Cable GenFire® Rail 400 CSA Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 3,6\/6 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence:\u003c\/strong\u003e\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e27.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e3.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e30.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e36.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.0495\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3915\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7536122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7250851987519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_7c3f9d8c-4170-41bb-995e-c0dbd4580d7a.jpg?v=1571729370"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/collections\/Nassau-lg_15a4b5ed-b555-49b6-8562-13da0a54a2a2.jpg?v=1523089163","url":"https:\/\/www.nassauelectrical.com\/collections\/general-cable-genfire%c2%ae-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-3-6-6-kv.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}