{"title":"General Cable GenFire® Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"","products":[{"product_id":"general-cable-genfire®-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv-1","title":"General Cable GenFire® Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\"\u003ecross-sectional area\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eweight\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003egeneral cable part number\u003c\/td\u003e\n\u003ctd rowspan=\"2\"\u003eAction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"background-color: #495682;\"\u003e\n\u003ctd style=\"color: #ffffff;\"\u003emm²\u003c\/td\u003e\n\u003ctd style=\"color: #ffffff;\"\u003ecopper kg\/km\u003c\/td\u003e\n\u003ctd style=\"color: #ffffff;\"\u003ecable kg\/km\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-1-5-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e1.5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-1-5-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e7535106\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-1-5-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"https:\/\/nassauelectrical.com\/products\/general-cable-genfire%C2%AE-2-5-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv\"\u003e2.5\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-2-5-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e7535107\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"https:\/\/nassauelectrical.com\/products\/general-cable-genfire%C2%AE-2-5-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-4-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-\"\u003e4\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e81\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-4-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-\"\u003e7535108\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-4-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-6-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-\"\u003e6\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-6-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-\"\u003e7535109\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-6-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-10-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e10\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-10-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e7535110\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-10-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-16-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e16\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-16-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e7535111\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-16-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-25-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e25\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-25-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e7535112\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-25-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-35-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e35\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e292\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-35-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e7535113\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-35-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-50-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e50\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e418\u003c\/td\u003e\n\u003ctd\u003e540\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-50-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e7535114\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-50-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-70-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e70\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e596\u003c\/td\u003e\n\u003ctd\u003e735\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-70-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e7535115\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-70-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-95-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e95\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e795\u003c\/td\u003e\n\u003ctd\u003e950\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-95-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003e7535116\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-95-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-120-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e120\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1003\u003c\/td\u003e\n\u003ctd\u003e1195\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-120-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e7535117\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-120-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-150-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e150\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1245\u003c\/td\u003e\n\u003ctd\u003e1470\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-150-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e7535118\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-150-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-185-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e185\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e1556\u003c\/td\u003e\n\u003ctd\u003e1750\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-185-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e7535119\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-185-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-240-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e240\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2030\u003c\/td\u003e\n\u003ctd\u003e2290\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-240-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e240\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-240-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-300-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e300\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e2571\u003c\/td\u003e\n\u003ctd\u003e2855\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-300-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e7535121\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-300-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-400-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e400\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e3382\u003c\/td\u003e\n\u003ctd\u003e3850\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-400-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003e7535122\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan class=\"add-to-cart\"\u003e\u003ca href=\"http:\/\/www.nassauelectrical.com\/products\/copper-building-wire\/genfire-rail-en-cables\/genfire-400-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-\"\u003eRequest a Quote\u003c\/a\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249368350783,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_8fb2d38d-fc8e-449b-bc43-a5d7523f7386.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-1-5-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 1.5 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e1.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e6.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e7.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e13.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249569742911,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_7deed777-db56-4f69-9216-5f14b4de0d16.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-2-5-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 2.5 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e2.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e6.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e7.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e8.21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249571414079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_70b4f66a-0ba1-45cd-9a57-79b1a117d56c.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-4-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 4 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e2.40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e7.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e8.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e5.09\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e81\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249572986943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_64096daf-56f2-4bbd-aab5-c39456878047.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-6-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 6 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e3.10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e7.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e3.39\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535109\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249575936063,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_cd107a30-d2aa-49fc-8a7d-1528a2b9791d.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-10-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 10 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e4.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e8.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e10.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e1.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e89\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e155\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249577082943,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_b0171300-9bdc-44fb-a5cb-8499e1e32ac3.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-16-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 16 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e4.90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e9.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e11.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e1.24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249599168575,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_9a4b119e-d6f0-4a92-9104-69eec4c67cee.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-25-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 25 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e6.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e10.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e12.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.795\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e205\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249601364031,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_a2c1d072-a9ab-4f05-8ffb-93dd9e349790.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-35-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 35 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e7.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e12.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e14.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.565\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e292\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535113\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249604182079,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_cab9883e-905a-4a67-8902-73889f6fc773.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-50-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 50 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e9.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e13.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e15.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.393\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e418\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e540\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535114\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249605689407,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_e6a8e6be-6757-490f-a4ea-d003957a1097.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-70-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 70 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e10.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e15.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e17.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e596\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e735\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249607360575,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_898327de-8791-47ee-a00a-25dfab76b4fd.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-95-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 95 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e12.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e17.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e19.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e795\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e950\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535116\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249637474367,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_8bbb0486-7076-4779-ab52-770647156212.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-120-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 120 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e14.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e18.6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e21.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.164\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1195\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535117\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249640980543,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_89a80a41-e32f-4d4d-a3e6-c59d66654123.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-150-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 150 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e15.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e20.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e23.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.132\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1245\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1470\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535118\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249643077695,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_b1aed852-fc79-4fc0-b32e-f733d0cdeb61.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-185-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 185 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e185\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e17.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e21.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e25.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1556\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e1750\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535119\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249645174847,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_b17c4cb3-7075-4146-9702-2918a873b5cb.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-240-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 240 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e240\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e20.20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e24.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e28.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.0817\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2290\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249646092351,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_caea45d9-8adb-4300-86bb-ee83d1b97756.jpg?v=1571729369"},{"product_id":"general-cable-genfire®-300-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 300 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e22.50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e26.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e30.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.0654\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2571\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e2855\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249646747711,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_c1bcd81f-acf4-4be1-ab7a-1cd1a26d1a13.jpg?v=1571729370"},{"product_id":"general-cable-genfire®-400-csa-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv","title":"General Cable GenFire® 400 CSA Rail Single Core Unsheathed Silicone Rubber 120˚C Low-Smoke Halogen-Free EN Cable 1,8\/3 kV","description":"\u003ch4\u003eProduct Details\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConductor:\u003c\/strong\u003e\u003cbr\u003e • Flexible Class 5 stranded tinned copper per IEC 60228\u003cbr\u003e • Optional: separator tape\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation:\u003c\/strong\u003e\u003cbr\u003e • 120°C Low-Smoke, Halogen-Free Silicone Rubber according to EN 50382-1 (E111)\u003cbr\u003e • Black – unless otherwise specified\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCable Markings:\u003c\/strong\u003e\u003cbr\u003e • Manufacturer’s Name\u003cbr\u003e • EN Reference\u003cbr\u003e • Voltage Rating (U0)\u003cbr\u003e • Conductor Size\u003cbr\u003e • Insulation Code Designation per Annex A of EN 50382-2\u003cbr\u003e • Conductor Temperature\u003cbr\u003e • Lot Number\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e High temperature power\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTested in Accordance with:\u003c\/strong\u003e\u003cbr\u003e • EN 60811-2-1: Resistant to Mineral Oil\u003cbr\u003e • EN 50305: Ozone-Resistant\u003cbr\u003e • EN 50382-1-9 Part 2: No Toxicity\u003cbr\u003e • EN-60811-1-4: Cold Bend (-40ºC)\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOther Design Adherence\u003c\/strong\u003e:\u003cbr\u003e • EN 60332-1-2 and EN 60332-3-24, -25: Flame- \u0026amp; Fire-Retardant\u003cbr\u003e • EN 50382-1 Annex A \u0026amp; B: Halogen-Free; Low Acidity and Corrosivity of Evolved Gases; Fluorine Content\u003cbr\u003e • EN 61034-2: Low-Smoke\u003cbr\u003e • No SVHC Listed Chemicals under REACH\u003cbr\u003e • RoHS Compliant\u003c\/p\u003e\n\u003cdiv class=\"siraj siraj-sub\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"2\"\u003etechnical specification:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecross-sectional area(mm²)\u003c\/td\u003e\n\u003ctd\u003e400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor diameter(mm)\u003c\/td\u003e\n\u003ctd\u003e27.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emean thickness of insulation(mm)\u003c\/td\u003e\n\u003ctd\u003e2.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(min. mm)\u003c\/td\u003e\n\u003ctd\u003e29.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ecable diameter(max. mm)\u003c\/td\u003e\n\u003ctd\u003e34.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003econductor resistance(max. ω\/km)\u003c\/td\u003e\n\u003ctd\u003e0.0495\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(copper kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3382\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eweight(cable kg\/km)\u003c\/td\u003e\n\u003ctd\u003e3850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epart number\u003c\/td\u003e\n\u003ctd\u003e7535122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e","brand":"Nassau","offers":[{"title":"Default Title","offer_id":7249647763519,"sku":"","price":0.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0013\/1117\/8815\/products\/Nassau-lg_7ba96d9c-aeca-4f96-9f53-333bb48f1409.jpg?v=1571729370"}],"url":"https:\/\/www.nassauelectrical.com\/collections\/general-cable-genfire%c2%ae-rail-single-core-unsheathed-silicone-rubber-120-c-low-smoke-halogen-free-en-cable-1-8-3-kv.oembed?page=2","provider":"NassauElectrical","version":"1.0","type":"link"}